Maximum Load Capacity: 25 lb (11 kg)  
R
Read instruction sheet before you start installation and assembly.  
WARNING  
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard-  
ware and components.  
IMPORTANT! Turn to the appropriate page for your ceiling installation.  
Applications:  
FlushMount ................................................................................................................................................. page 5  
ExtensionColumn........................................................................................................................................ page 6  
Lightweight Suspended Ceiling Plate ....................................................................................................... page 7  
Installations:  
To Wood Joist Finished Ceilings,  
Exposed Wood Joists, or Wood Beam Ceilings........................................................................................ page 3  
To Concrete Ceilings.................................................................................................................................... page 4  
ISSUED: 10-22-04 SHEET #: 055-9236-5 01-10-06  
1 of 11  
 
Disengage connection block from projector mount assembly (A) by unscrewing captive screw and sliding out  
connection block as shown.  
A
CONNECTIONBLOCK  
CAPTIVESCREW  
Installation To Wood Joist Finished Ceilings, Exposed  
Wood Joists, or Wood Beam Ceilings  
Drill two 5/32" (4 mm) dia. holes to a minimum depth  
of 2.5" (64 mm). Attach ceiling plate (Q) with two  
#14 x 2.5" (6 mm x 65 mm) wood screws (F) as  
shown using 3/8" (10 mm) socket wrench. Tighten  
wood screws (F) so ceiling plate (Q) is firmly  
attached.  
WOOD  
JOIST  
CEILING  
WARNING  
• Tighten wood screws so that ceiling plate is firmly  
attached, but do not overtighten. Overtightening can  
damage the screws, greatly reducing their holding  
power.  
Q
• Never tighten in excess of 80 in • lb (9 N.M.).  
• Make sure that mounting screws are anchored into the  
center of the joist. The use of an "edge to edge" stud  
finder is highly recommended.  
F
F
Skip to step 7.  
WOOD  
JOIST  
For optional Cord Management,  
install two spacers (L) between ceiling  
plate (Q) and ceiling.  
CEILING  
L
L
Q
F
F
ISSUED: 10-22-04 SHEET #: 055-9236-5 01-10-06  
3 of 11  
 
Installation to Concrete Ceilings  
Alligator® concrete anchors are recommended.  
Drill two 1/4" (6 mm) dia. holes to a minimum depth of  
2.5" (64 mm). Attach ceiling plate (Q) using two  
concrete anchors (G) and #14 x 2.5" wood screws (F)  
as shown in Illustration A and 1, 2, and 3. Tighten all  
fasteners.  
G
Skip to step 7.  
CONCRETECEILING  
Q
WARNING  
F
• Make sure that the supporting surface will safely  
support the combined load of the equipment and all  
attached hardware and components.  
• Tighten concrete anchor bolt firmly, but do not over-  
tighten. Overtightening can damage the bolt, greatly  
reducing its holding power.  
Illustration A  
• Never tighten in excess of 80 in • lb (9 N.M.).  
concrete  
ceiling  
1
WARNING  
• Concrete anchors are not intended for attachment to  
G
concrete wall covered with a layer of plaster, drywall,  
or other finishing material. If mounting to concrete wall  
covered with plaster/drywall is unavoidable, plaster/  
drywall (up to 5/8" thick) must be counterbored as  
shown below. If plaster/drywall is thicker than 5/8",  
custom fasteners must be supplied by installer.  
Drill hole and insert anchor.  
2
Q
F
G
INCORRECT  
Place ceiling plate over anchor and secure with screw.  
metal  
concrete  
bracket  
3
plaster/  
dry wall  
G
F
After repeating step one tighten all fasteners.  
CORRECT  
metal  
bracket  
concrete  
plaster/  
dry wall  
ISSUED: 10-22-04 SHEET #: 055-9236-5 01-10-06  
4 of 11  
 
Flush Mount Installation  
Drill two 5/32" (4 mm) dia. holes to a minimum depth of 2.5" (64 mm). Attach projector mount assembly (A) with two  
#14 x 2.5" (6 mm x 65 mm) wood screws (F) and two flat washers (E) as shown in figure 1 or figure 2 depending  
on joist orientation. Tighten wood screws (F) using 3/8" (10 mm) socket wrench until projector mount assembly (A)  
is firmly attached.  
WARNING  
• Tighten wood screws so that projector mount assem-  
bly is firmly attached, but do not overtighten. Overtight-  
ening can damage the screws, greatly reducing their  
holding power.  
• Never tighten in excess of 80 in • lb (9 N.M.).  
• Make sure that mounting screws are anchored into the  
center of the joist. The use of an "edge to edge" stud  
finder is highly recommended.  
Skip to step 7.  
WOOD JOIST  
WOOD JOIST  
A
FRONT OF  
MOUNT  
FRONT OF  
MOUNT  
A
E
F
E
F
figure 1  
figure 2  
ISSUED: 10-22-04 SHEET #: 055-9236-5 01-10-06  
5 of 11  
 
Installation to Extension Column (SP-EXTARM-01, SP-  
EXTARM-02, SP-EXTARM-03, SP-EXTARM-04)  
Q
Screw extension column (sold separately) to  
ceiling plate (Q). Align the notch with one of the  
four holes in the ceiling plate (Q) and secure  
extension column with a M5 x 10 mm socket pin  
screw (M) using security allen wrench (B). See  
detail 3.  
Screw projector mount assembly (A) onto the  
extension column as shown in detail 4.  
EXTENSIONCOLUMN  
(SOLD SEPARATELY)  
(UL LISTED)  
N
Q
M
Note: For 3/4" extension columns, reducer  
ACC 913 will be required as shown in detail 5.  
Tighten swivel stop screw against extension  
column or reducer using security allen wrench (B).  
EXTENSION  
COLUMN  
Note: Swivel stop screw is used to jam against  
threads of extension column or reducer to prevent  
any excess movement of projector mount  
assembly (A). Do not overtighten screw;  
overtighteningscrewwilldamagethreadsmaking  
it difficult to separate products.  
DETAIL 3  
Note: Slotted set screws (N) are used to jam  
against the threads of each connecting joint to  
preventanyexcessmovement.Donotovertighten  
screws;overtighteningscrewswilldamage  
threads making it difficult to separate the  
products.  
A
BACK OF  
MOUNT  
SWIVELSTOPSCREW  
Skip to step 7.  
DETAIL 4  
3/4" EXTENSION COLUMN  
ACC 913  
(NOT UL LISTED)  
BACK OF  
MOUNT  
A
SWIVELSTOPSCREW  
DETAIL 5  
ISSUED: 10-22-04 SHEET #: 055-9236-5 01-10-06  
6 of 11  
 
Installation to  
LIGHTWEIGHT  
SUSPENDEDCEILING  
PLATE (SOLD  
Lightweight Suspended  
Ceiling Plate  
SEPARATELY)  
(EXT-LTMT-PLTB)  
Refer to instruction sheet for lightweight  
suspended ceiling plate (sold  
separately) for attachment of ceiling  
plate to ceiling.  
RETAINING COLLAR  
M
Screw extension column (sold  
separately) to retaining collar in ceiling  
tray. Align the notch with one of the  
four holes in retaining collar and secure  
extension column with a M5 x 10 mm  
socket pin screw (M) using security  
allen wrench (B). See detail 6.  
N
DETAIL 6  
EXTENSION  
COLUMN  
(UL LISTED)  
Screw projector mount assembly (A)  
onto the extension column as shown in  
detail 7.  
Note: For 3/4" extension columns,  
reducer ACC 913 will be required as  
shown in detail 8.  
Tighten swivel stop screw against  
extension column or reducer using  
security allen wrench (B).  
A
Note: Swivel stop screw is used to jam  
against threads of extension column or  
reducer to prevent any excess  
movementofprojectormountassembly  
(A). Donotovertightenscrew;  
overtighteningscrewwilldamage  
threads making it difficult to separate  
products.  
SWIVEL STOP SCREW  
DETAIL 7  
Note: Slotted set screws (N) are used  
to jam against the threads of each  
connecting joint to prevent any excess  
movement.Donotovertightenscrews;  
overtighteningscrewswilldamage  
threads making it difficult to separate  
the products.  
DETAIL 8  
3/4" EXTENSION  
COLUMN  
Skip to step 7.  
P
L
T
B
ACC 913  
(NOT UL  
LISTED)  
BACK OF  
MOUNT  
A
SWIVELSTOPSCREW  
ISSUED: 10-22-04 SHEET #: 055-9236-5 01-10-06  
7 of 11  
 
Note: The projector adapter plate and projector you are installing may differ in appearance from the sample illustrated  
below.  
Align shoulder on connection block opposite of front of projector. Attach adapter plate (R) to connection block from  
projector mount assembly (A) using two #10-32 x 3/8" serrated socket pin screws (C) as shown.  
CONNECTION BLOCK  
SHOULDER  
ADAPTER PLATE  
R
FRONTOF  
PROJECTOR  
C
P
R
Attach extension brackets (S) to adapter plate (R)  
using two M4 x 6 mm serrated socket pin screws (P).  
For specific models, see step 8H.  
S
ISSUED: 10-22-04 SHEET #: 055-9236-5 01-10-06  
8 of 11  
 
Flip projector upside down. Find your projector from the models listed below. Using the holes indicated on the corre-  
sponding hole pattern diagram, attach adapter plate (R) to projector using three M4 x 16 mm serrated socket pin  
screws (H) and three .198 x .313 x .375 retaining spacers (J).  
Notes:  
Retaining spacers go between adapter plate and projector.  
* Front of projector.  
** Projectors using hole pattern G use one M4 x 12 mm screw (I) and one .198 x .313 x .187 retaining spacer (K)  
where indicated.  
*** Using holes indicated in hole pattern H, attach adapter plate (R) to projector using four M6 x 12 mm serrated  
socket pin screws (O) and four spacers (L)  
A. C200, DP6500X, LP650, SP5700,  
B. C40, C50, DP2000S, DP2000X,  
C. LP340, LP350, LP500, LP530,  
SP7200, SP7205, SP7210  
LP240, LP250  
SP110  
*
*
*
R
R
R
D. C100, C105, DP6150, DP6155,  
E. C109, C110, DP8000, LP790,  
F. C170, LP600  
LP690  
SP4800, SP4805, X1, X1a, X2, X3  
*
*
*
R
R
R
I. C410, C420, LP815, LP820,  
H. C440, C450, C460, DP8400X,  
G. C160, C180, LP540, LP640,  
DP8500X, LP840, LP850, LP860  
SP5000  
DP8200X  
S
***  
*
***  
*
*
S
**  
R
R
***  
R
***  
ISSUED: 10-22-04 SHEET #: 055-9236-5 01-10-06  
9 of 11  
 
K. IN24, IN26  
J. IN72, IN74, IN76  
*
*
R
R
WARNING  
• Always use an assistant or mechanical lifting equipment to safely lift and position the projector.  
Slide connection block with projector into projector mount  
assembly (A) as shown. Tighten captive screw to secure  
projector to projector mount assembly (A).  
IMPORTANT: For security installations, insert  
one #10-32 x 1/4" socket pin screw (D) through  
projector mount assembly (A) and into connection  
block as shown.  
CONNECTIONBLOCK  
A
CONNECTIONBLOCK  
A
FRONTOFMOUNT  
D
CAPTIVESCREW  
ISSUED: 10-22-04 SHEET #: 055-9236-5 01-10-06  
10 of 11  
 
Projector Alignment  
To adjust yaw (swivel) for wood stud, concrete ceiling, and threaded rod mounting applications: Loosen  
wood screws (F), or locknuts for threaded rods, until projector mount can be rotated. Rotate mount to desired  
position and retighten screws or locknuts.  
To adjust yaw (swivel) for extension column applications: Loosen screw on projector mount assembly (A)  
indicated below until projector mount can be rotated. Rotate mount to desired position and retighten screw.  
To adjust pitch (forward and backward tilt): Loosen two screws on projector mount assembly (A) indicated  
below. Tilt mount to desired position and retighten screws.  
To adjust roll (side to side tilt): Loosen two screws on projector mount assembly (A) indicated below. Tilt mount  
to desired position and retighten screws.  
SCREW FOR SWIVEL STOP  
A
SCREWS FOR ROLL  
SCREWS FOR PITCH  
ADJUSTMENT  
ADJUSTMENT  
BACKOFMOUNT  
ISSUED: 10-22-04 SHEET #: 055-9236-5 01-10-06  
11 of 11  
 

Ingersoll Rand Swimming Pool Pump 670049 X User Manual
Intel Computer Hardware 6700PXH User Manual
Intellinet Network Solutions Welding Consumables 521796 User Manual
JVC Camcorder DY 70U User Manual
JVC Car Video System TM H1950CG User Manual
JVC DVD Player XV SA70BK User Manual
JVC Stereo Receiver RX 5001VGD User Manual
Kenwood Network Hardware TS 990S User Manual
King Canada Lathe CH 900C User Manual
Konica Minolta Printer IP 011 User Manual