Intel® Carrier Grade Server TIGH2U
Configuration Guide System / Spares / Accessories List
March 2008
Rev 1.2
Reference guide to assist customers and the field in ordering the servers,
accessories and spares
~Subject to Change Without Notice~
Document Table of Contents
I. INTRODUCTION........................................................................................................ 4
II. PRODUCTION SKUS.................................................................................................. 5
RACK MOUNT SERVERS................................................................................................. 13
3/28/2008
v 1.2
3 of 20
I. Introduction
Product Description:
The Intel® Carrier Grade Server TIGH2U is the 4th generation of the 2U x 20”D Intel®
Telecom and Industrial Grade Rack Server. The TIGH2U supports the 45nm Quad-Core
Intel® Xeon® processor 5400 Series with 12M L2 cache, coupling high performance with
power efficiency to provide improved performance-per-watt over previous-generation
rack-mount servers.
The TIGH2U is a NEBS-3 and ETSI certified product which is suited for a host of
applications in the telecom Central Office and industrial environment. The server is
targeted to OSS (Operations System and Support), Billing, Provisioning, Softswitch,
Media Server, Wireless and Unified Messaging, Call Center and many other
applications. It can also support manufacturing, industrial, utility and even military
applications where a rugged, highly reliable server is required for harsh environments
such as dust, high altitude, fire hazard, earthquake propensity, and high ambient
temperatures.
More product information is available at the following websites:
TIGH2U Product Overview
TIGH2U Product Support
Purpose of this Document:
This document provides details on what parts are available for ordering of the Intel®
Carrier Grade Server TIGH2U production systems. This includes PID and MM#
information for System SKUs, Accessories & Spares, as well as other Intel parts that
are supported by the TIGH2U product.
Supported third-party components are not covered by this document, and may be
found in the Tested Hardware and Operating System List (THOL) for this product.
3/28/2008
v 1.2
4 of 20
II. Production SKUs
The TIGH2U Production SKUs that can be ordered are listed below:
Min. Order
Qty.
PID Order Code Description
MM#
Intel® Carrier Grade Server TIGH2U
Base Model 0 with AC Power Supply.
TLHA0201W
TLHD0201W
890868
890910
1
1
Intel® Carrier Grade Server TIGH2U
Base Model 0 with DC Power Supply.
See the TIGH2U Base Model 0 Configuration table further down in this section for a
list of components included in each base model 0 SKU.
Production SKUs are offered as either an AC or a DC version. The Product
Identification code or PID of all SKUs contains the letter “A” for AC or “D” for DC as
the 4th digit of the PID.
Both Production SKUs are base model 0 SKUs, (no processor, heatsink, memory, hard
drive, power cord, operating system, or plug-in adapters are provided). Those
components must be ordered separately as Accessories from Intel or from third party
vendors listed in the Tested Hardware and Operating System List (THOL).
Power Cords are not included with the Mod 0 system. For AC Power cords, order the
NA – North American power cord below. This power cable is RoHS-compliant.
PID
MM#
Comments
This AC power cable can be ordered by North
America (NA) customers. International customers
should procure their specific power cords directly.
PWRCABLEUS 816324
Note: Ensure that customers have the appropriate technical support and contact
before placing the first order.
3/28/2008
v 1.2
5 of 20
TIGH2U Base Model 0 Configuration
All Production SKUs are base model 0 SKUs (no CPU, heatsink, memory, hard drive or
plug-in adapters are provided). Those components must be ordered separately as
Accessories from Intel or from third party vendors listed in the Tested Hardware and
Operating System List (THOL). The below table lists how many of each component is
included in the Production model 0 SKU.
The table below lists which components are included in the base model 0 SKUs and
which ones must be ordered separately or as optional accessories.
AC Mod 0
Configuration Configuration
DC Mod 0
Component Description
AC power supply (600 W)
DC power supply (600 W)
1 included
-
-
1 included
Filler Panel in 2nd power supply bay
Chassis (bezel, sheet metal, top cover, PCI carrier)
Server Board T5000PAL
1 included
1 included
1 included
Bezel (unpainted)
1 included
PCI Riser FH-FL (two PCI-Express and one PCI-X slots)
PCI Riser LP (two PCI-Express slots)
FB-DIMM slots (memory not included)
Trays for hot-swap 2.5” SAS Hard Disk Drives
Filler Panel in optical device bay
Rear Panel GbE NIC (Cu) ports (via Server Board)
Server Deployment Toolkit (CD)
Quick Start Guide
1 included
1 included
8 included
6 included
1 included
2 included
1 included
1 included
Power Cable
SW RAID 0/1/10
Purchase separately1
Included
HW RAID 5
Optional Accessories2
Optional Accessory2
Optional Accessory2
Optional Accessory2
Optional Accessories2
Optional Accessory2
Optional Accessory2
Optional Accessory3
Purchase separately4
Accessory or purchase separately
Purchase separately4
Purchase separately4
Purchase separately4
Intel® Z-U130 Value Solid State Drive
Mounting kit for Intel® Z-U130 Value Solid State Drive
Remote Management Module 2
PCI-X FH-FL Riser (3 PCI-X slots)
Ethernet I/O Module (dual Gigabit rear ports)
SAS I/O Expansion Module (x4 external rear port)
Rack Mount Kits
Processor (refer to “Details on Ordering Processors”)
Heatsink
Memory
Hard Disk Drive
Optical Drive
1Refer to AC power cord accessory in this section
2Refer to “Production Spares/Accessory List” in section III
3Refer to “Rack Mounting Options” in the Appendix
4Should be purchased separately (parts not listed in this document)
3/28/2008
v 1.2
6 of 20
Notes on the TIGH2U Model 0 Configuration and Options:
ꢀ PCI Risers
o The base configuration comes standard with two PCI Risers supporting up to
five PCI slots. These include:
ꢁ One low-profile riser supporting two PCI-Express (PCIe) slots
ꢁ One full-height, full-length riser supporting three slots: two PCIe x4
and one PCI-X.
o Additional full-height, full-length risers (below) are supported and available
as accessories (refer to “Production Spares/Accessories List” in section III).
ꢁ PCI-X (active): three independent PCI-X, each with maximum 133
MHz
ꢁ PCI-X (passive): two PCI-X with maximum 100 MHz and one PCI-X (66
MHz) all on a shared PCI bus
ꢀ HW RAID
o While SW RAID 0/1/10 is supported on the base configuration, HW RAID 5
support can be enabled via a set of optional accessories (refer to
“Production Spares/Accessories List” in section III).
o Components required are NSCRAID01W (NSC2U RAID5 Kit – includes the I-
Button (license), battery cable) and the AXXMINIDIMM (128 MB Mini DIMM
registered DDR-2 for RAID cache.)
o An additional option is the AXXRSBBU3 (Intel® RAID Smart Battery Backup
module provides up to 72 hours of cache memory retention when used with
AXXMINIDIMM). The cable to connect the battery is included in the
NSCRAID01W kit.
ꢀ Intel® Z-U130 Value Solid State Drive
o Support for the Intel® Z-U130 Value Solid State Drive is available via a
selection of optional accessories (refer to “Production Spares/Accessories
List” in section III).
o Components required are an Intel® Z-U130 Value Solid State (select desired
capacity) as well as a mounting kit (TMWVSSDRIVE01W) to mount it inside
the chassis.
o Solid state drives are available in several sizes, enabling an array of product
customization options. These drives securely mount inside the chassis
offering
ꢁ Storage: independent of traditional disk drives
ꢁ Boot OS from solid state drive; store data on hard drive
ꢁ Store backup image of boot drive
ꢁ Add a server partition to the server
ꢁ Any other customer design options
3/28/2008
v 1.2
7 of 20
ꢀ IO Option Modules
o These modules, available as optional accessories, attach to the system
board via a proprietary connector, and provide additional IO through the
rear bulkhead.
ꢁ The AXXGBIOMO option module provides two Gigabit Ethernet NICs.
ꢁ The AXXSASIOMOD option module provides one x4 external SAS port.
o Note: Using the AXXGBIOMOD on the TIGH2U may result in non-compliance
of NEBS GR-63 short term operating conditions.
o For ordering details, refer to “Production Spares/Accessories List” in
section III.
ꢀ Air Filters are not provided with the TIGH2U base system. If air filters are
required by customer, then customer must purchase them separately.
For more detailed information on the TIGH2U, refer to the web links below.
Additional Product Details
Check the following web site for more information on the TIGH2U:
Support.Intel.Com Users
Product information including specifications, compatibility, user’s guides, drivers,
firmware, and software associated with the Intel® Carrier Grade Server TIGH2U is
available from Intel Customer Support.
Intel® Carrier Grade Server TIGH2U Support Web Site
If you can not access the documents using the links provided, please contact your
FAE/FSE for assistance.
3/28/2008
v 1.2
8 of 20
Details on Ordering of Processors:
The TIGH2U supports the Quad-Core Intel® Xeon® processor 5400 Series. Ordering
details for the CPUs for use in TIGH2U are listed below, and includes both Tray (for
OEMs) and Boxed (Retail channel) processors.
Quad-Core Intel® Xeon® Processors Supported by TIGH2U:
Processor
Number
E5440
Long
Life
Yes
Boxed Processor
Tray Processor
Product Code
Cores
Quad
Speed
2.83 GHz
TDP
80W
FSB
1333 MHz
Product Code
MM#
MM#
BX80574E5440P 894824
EU80574KJ073N
893484
L5410
Yes
Quad
2.33 GHz
50W
1333 MHz
BX80574L5410P 894835
EU80574JJ053N
893491
Notes:
ꢀ The above processors are tested and supported by Intel and are recommended for
long availability and support.
ꢀ
Heatsinks
o This product requires Passive heatsinks. The boxed processors listed above include
a Passive Heatsink Kit, made of aluminum. Do not use Active Fan Heatsinks, which
are provided in some Retail Boxed Processors.
o For Tray processors, you will need to procure a Heatsink for each processor (see
NSCSNKCLP01 in the Spares/Accessories list below). This is a copper heatsink.
There are no clips needed for this heatsink, since the heatsink includes captive
screws.
o If ordering other Boxed Processors (not listed here), do not use the fansink, which
might be included.
Note that CPU product codes can change, and that the above is a snapshot current as
of 3/28/2008. Please consult with your Intel representative for SSpec or MM# which
may be needed for ordering the CPU. Any differences in functionality is reported in
3/28/2008
v 1.2
9 of 20
III. Production Spares/Accessories List
Below are the Spares parts and Accessories that may be ordered with the TIGH2U
system. Any of these parts may be ordered as spares for part replacement purposes
or as additional customer inventory. Some of the parts below are not included in the
TIGH2U system base model and may be ordered as accessories for purposes of
upgrading the base model to include additional features.
Note, for a listing of additional compatible accessories, such as Optical Devices for
use with the CD-ROM carrier, please refer to the Tested Hardware and Operating
System List (THOL).
Included in
Base Model
(Y/N)
Min.
Order
Qty
PID Order Code
Description
Contents
MM#
Y
AC power supply
TIGI2U AC Power Supply
TIGI2U DC Power Supply
NSC2U CPU Heatsink
1
1
1
TLIACPSU003
TLIDCPSU003
880110
880116
891200
(one in AC SKU)
DC power supply,
input power connector
Y
(one in DC SKU)
Heatsink (copper)
N
NSCSNKCLP01
HW RAID
I-Button (license),
battery cable (battery
or mini-DIMM not
included)
NSC2U RAID5 Kit
N
1
5
NSCRAID01W
AXXRSBBU3
890202
883471
Intel® RAID Smart Battery Backup
module: for use with Intel® Integrated
Server RAID (requires NSCRAID01W
plus mini DIMM), provides up to 72
hours of cache memory retention
when used with AXXMINIDIMM.
128 MB Mini DIMM registered DDR-2
for RAID cache.
Note: enabling RAID capability also
requires Intel RAID Activation Key–
NSCRAID01W
(order in
multiples
of 5)
Battery backup kit
Mini-DIMM
N
N
5
(order in
multiples
of 5)
AXXMINIDIMM
881258
Remote Management
Intel® Remote Management Module
2 (RMM2) - Single Pack
RMM2 with GCM
(single-pack)
N
N
1
AXXRMM2
894383
894385
10
(specify
‘1’ for
each 10-
pack)
Intel® Remote Management Module
2 (RMM2) – 10-Pack
RMM2 with GCM (10-
pack)
AXXRMM2BULK
3/28/2008
v 1.2
10 of 20
Production Spares/Accessories List (continued)
Included in
Base Model
(Y/N)
Min.
Order
Qty
Contents
PID Order Code
Description
MM#
PCI Risers and I/O Options
SR2500 (2U) Full Height PCI-Express
riser (two PCI-Express slots, one
PCI-X slot)
Riser
Y
1
ASR2500FHR
880515
SR2500 (2U) Full Height PCI-X
"active" high performance riser card
(three PCI-X slots)
Riser
N
N
1
1
ADRACTRIS
ADRPCIXRIS
856546
863135
SR2500 (2U) Full Height PCI-X
“passive” riser card (three PCI-X
slots)
Riser
Riser
Two-slot Low Profile PCI-Express
riser
Y
N
N
1
1
1
FSR2500LPR
880516
880518
880517
Dual Gigabit rear
ports
Dual Gigabit Ethernet I/O Module
AXXGBIOMOD
Four-port external SAS I/O Expansion
Module
x4 external rear port
AXXSASIOMOD
Solid State Drives
Mounting kit for Intel® Z-U130
Value Solid State Drive
Interposer board,
cable, mounting
screws (flash drive
not included)
N
1
TMWVSSDRIVE01W
893165
Requires Intel® Z-U130 Value Solid State
Drive (purchased separately).
Intel® Z-U130 Value Solid State
Drive - 1 GB, Low Profile Connector
1 GB Module – Low
Profile Connector
N
N
N
10
10
10
SSDUSMS0001GL10
SSDUSMS0002GL10
SSDUSMS0004GL10
890945
890943
890941
Requires TMWVSSDRIVE01W
Intel® Z-U130 Value Solid State
Drive – 2 GB, Low Profile Connector
2 GB Module – Low
Profile Connector
Requires TMWVSSDRIVE01W
Intel® Z-U130 Value Solid State
Drive - 4 GB, Low Profile Connector
4 GB Module – Low
Profile Connector
Requires TMWVSSDRIVE01W
Spares
12
(order in
multiples
of 12)
Bezel (painted)
TIGH2U Bezel
Y
TLHBEZEL004W
890813
TIGH2U Telco Alarms Module with
LED pipe
Module, LED pipe
Board
Y
Y
1
1
TLHTAM004W
890809
890773
TIGH2U Front Panel I/O Board
TLHFPIOBD04W
3/28/2008
v 1.2
11 of 20
Production Spares/Accessories List (continued)
Included in
Base Model
(Y/N)
Min.
Order
Qty
PID Order Code
Spares
Description
Contents
MM#
Flex cable (SAS
interface, front panel
signals), front panel
power cable, serial
port cable, CD-ROM
cable, alarm cable,
TAM module cable
TIGH2U System Interconnect
Cable Kit
Y
1
TLHSICBL004W
891494
80mm CPU fans (2),
40mm PCI fans (2),
plastic fasteners (8)
TIGH2U Fan Assembly (set of 4)
NSC2U Power Distribution Board
Y
Y
1
1
TLHFANSETW
893601
889805
Power distribution
board, with integrated
wire harness
NSCPWRDISBDW
Board
NSC2U T5000PAL Server board
NSC2U SAS Backplane
NSC2U Bridge board
Y
Y
Y
1
1
1
NSCSASBSBDW
NSCSASBKPLNW
NSCBRIDGEBDW
889828
889829
889852
Backplane
Board, insulator
Blue plastic
engagement bracket
& black plastic locking
clip, screws
NSC2U DVD Drive Engagement Tab
TIGW1U SAS HDD carrier
Y
Y
1
NSCDVDENGTABW
FXX25HDDCAR
889845
881681
10
Carrier, black plastic
filler, screws (4)
(order in
multiples
of 10)
3/28/2008
v 1.2
12 of 20
Appendix A. Rack Mounting Options for 1U and 2U
Intel® Communications Rack Mount Servers
Rack mounting kits for 2-post or 4-post, 19-inch or 23-inch racks are offered for this
product. Please refer to the tables below for the correct options to suit your needs.
All rack mount kits listed are suitable for 1U and 2U Intel® Communications Rack
Mount Servers. Installation instructions are included in each kit.
2-post Rack Mounting Kit Options
Rack width
Post depth
Rack fastener hole spacing
Applicable kits:
19 inch 23 inch 3 inch 5 inch EIA-Wide
EIA-Universal ETSI
TMLCMOUNT21 ꢂ
TMLPMOUNT41 ꢂ
TMLPMOUNT51 ꢂ
TMLPMOUNT52
ꢂ
ꢂ
ꢂ
ꢂ
ꢂ
ꢂ
ꢂ
ꢂ
ꢂ
ꢂ
ꢂ
ꢂ
ꢂ
ꢂ
ꢂ
ꢂ
ꢂ
4-post Rack Mounting Kit Options
Front-post to
rear-post distance
Rack fastener
hole spacing
Rack width
Applicable kits:
Min
(inches)
Max
(inches)
EIA-
EIA-
19 inch 23 inch
ETSI
Wide Universal
TMLPMOUNT41 ꢂ
TMLPMOUNT51 ꢂ
TMLPMOUNT52
20
20
24
24
ꢂ
ꢂ
ꢂ
ꢂ
ꢂ
ꢂ
ꢂ
20
24
ꢂ
TMLPSLIDE01†
ꢂ
22.5
28 or 34††
†The TMLPSLIDE01 kit contains server securing brackets. The rails and other options
for mounting the server are available through other venders such as Accuride
††34-inch span requires the optional Accuride "Long Bracket" kit.
3/28/2008
v 1.2
13 of 20
TMLCMOUNT21
The TMLCMOUNT21 kit mounts Intel® Communication Rack Mount Servers to a 2-post,
central office type, 19” wide rack. This kit consists of simple L-shaped brackets;
which fasten to the sides of the server and to the rack.
TMLCMOUNT21
3/28/2008
v 1.2
14 of 20
TMLPMOUNT41, TMLPMOUNT51 and TMLPMOUNT52
TMLPMOUNT41/51/52 series mounts Intel® Communication Rack Mount Servers to 2-
post or 4-post racks.
TMLPMOUNT41 and TMLPMOUNT51 are used for mounting servers on 19” wide racks.
These racks are considered standard EIA (universal hole spacing) racks.
TMLPMOUNT52 is used for mounting servers on 23” wide racks. These racks could be
standard EIA (universal or wide hole spacing) or ETSI (European) racks.
TMLPMOUNT41/51/52 series are designed with a slide-in rail-type system. Although
the mounts are designed as rails, they are not sliding rails. This means the servers can
be slid into the racks for installation purpose, but the rails are not designed to
support a mounted server during service.
TMLPMOUNT4x/5x feature comparison
Plastic
strips2
Not
included
Side
TMLPMOUNT41
TMLPMOUNT51
TMLPMOUNT52
No1
Yes
Yes
EIA-Universal
Interference
access6
Xylan
EIA-Wide or EIA-
Universal4
Front
access
No
Included5
coating3
Interferance
Xylan
EIA-Wide, EIA-
Universal or ETSI
Front
access
Included5
N/A
coating3
Notes:
1. Extra care must be exercised with TMLPMOUNT41 to securely hold the server
with one's hands when sliding it out of the rack, else the server may fall to the
ground as its being removed.
2. Plastic strips on TMLPMOUNT41 have peeled off in some customer installations.
Consequence: The parts are usable, but the server may have somewhat of a
"scrape-in feel" rather than "slide in". Also, the rails will fit sloppier, so the
side-located chassis securing screws may be difficult to align in 2-post
installations. Replacement material is available from the plastic strip
manufacturer.
3. Xylan is a tough, low-friction coating similar to Teflon.
3/28/2008
v 1.2
15 of 20
4. EIA-Wide spacing doesn't have the interstitial hole that is present in EIA-
Universal. TMLPMOUNT51 contains an adapter bracket to overcome this EIA-
Wide issue.
5. This component (2U Nut Bar) enables installation of a rail kit into a 1U rack slot
when there is already equipment installed both above and below that open
slot.
6. The sides of the server must be accessible when using TMLPMOUNT41 in 2-post
racks.
3/28/2008
v 1.2
16 of 20
The diagrams above summarize the components and “slide-in rail-type” system of the
TMLPMOUNT41. It can be adapted for a 2-post or 4-post installation.
3/28/2008
v 1.2
17 of 20
The main difference between the TMLPMOUNT41 and TMLPMOUNT51/52 series is that
the TMLPMOUNT41 series uses a screw to lock the server in place via the Universal
Mounting Bracket, whilst the TMLPMOUNT51/52 series has an additional Slide Pull-Out
Locking feature.
The Universal Front Mounting Bracket on the TMLPMOUNT41
The Slide Pull-Out Locking feature on the TMLPMOUNT51/52
3/28/2008
v 1.2
18 of 20
TMLPSLIDE01
The TMLPSLIDE01 is an accessory kit designed for use in conjunction with slide rails to
produce a rack mounted serviceable server. The TMLPSLIDE01 kit contains two
Universal Front Mounting Brackets that secure the server to the front of the rack. The
sliding rails and optional mounting brackets required to mount the server must be
purchased through the channel. For example, the Accuride 22-inch Model 305A-LR
slide rails are designed to mount a server for “in-rack service.” This example would
also use an Accuride mounting bracket kit and the TMLPSLIDE01.
Universal Front Mounting Bracket with securing tab
Note: Using slide rails may result in non-compliance with Seismic Zone 4
requirements of NEBS-3 certification.
Ordering Information
Minimum Order
PID
Non-RoHS MM#
RoHS MM#
Quantity
TMLCMOUNT21
TMLPMOUNT41
TMLPMOUNT51
TMLPMOUNT52
TMLPSLIDE01
862501
838890
851760
851745
845583
881904
881907
881934
881935
881915
10
10
1
1
10
Customers should order RoHS items for shipments going to the European Union (EU).
3/28/2008
v 1.2
19 of 20
Although these mounts have been designed for industry standard racks, please consult
with your Intel Field Application or Sales Engineer before selecting racks for these
servers.
Compatible rack mounting kits may also be obtained from 3rd party suppliers.
3/28/2008
v 1.2
20 of 20
|