Ionic Pro Air Cleaner CA500 User Manual

IP_CA500_Mnl_Rev_092707.qxp:Layout 1 6/3/08 2:56 PM Page 1  
Owners Guide  
CA500  
 
IP_CA500_Mnl_Rev_092707.qxp:Layout 1 6/3/08 2:56 PM Page 4  
SAFETY INSTRUCTIONS  
®
H
Do not open the outer casing of the Ionic Pro ionic air purifier. Attempting  
EXTREMELY IMPORTANT INFORMATION: Safety precautions should always be  
used when operating this or any electrical appliance. Decrease the risk of electrocution,  
electric shock, injury or fire by reading and following all the warnings below:  
to open the unit will cause the warranty to be voided and could cause  
serious personal injury to the user and/or result in considerable damage  
to the unit.  
®
H
Use only as described in this Ionic Pro ionic air purifier manual. To reduce the  
®
H
H
risk of electric shock, do not attempt to service the product in any way  
other than in the manner described in the Cleaning and Maintenance section  
of this manual.  
Do not place the Ionic Pro ionic air purifier’s cord near a heated surface.  
®
Never operate the Ionic Pro ionic air purifier if the plug or cord is damaged or  
appears damaged. Only qualified service personnel should ever replace or attempt  
to replace a damaged power cord.  
®
H
Do not use the Ionic Pro ionic air purifier outdoors.  
®
®
H
H
H
Do not use the Ionic Pro ionic air purifier in bathrooms or other humid  
Never use the power cord to pick up, carry, drag, pull, or lift the Ionic Pro ionic  
environments, near fireplaces or in areas where flammable or combustible  
vapors or products may exist.  
air purifier. Do not pull the cord against or around sharp corners and edges. This  
could result in injury to the user or damage to the cord.  
®
H
Ionic Pro ionic air purifier operates at 120v AC and 60Hz only.  
Always remove the plug from its power outlet by holding onto the plug itself  
and pulling gently.  
H
To reduce the risk of electric shock, this product has a grounding-type plug that  
H
H
has a third grounding pin. This plug will fit only into a grounding-type power  
outlet. If the plug does not fit into the outlet, contact qualified service personnel  
to install the proper outlet. Do not alter the plug in any way.  
Never pull on the cord itself to unplug it from its power outlet.  
®
Use care when operating the Ionic Pro ionic air purifier by keeping all fingers,  
body parts, hair, loose clothing and jewelry away from openings.  
®
H
Always turn off all controls before unplugging the Ionic Pro ionic air purifier  
®
H
H
Never touch the Ionic Pro ionic air purifier or its plug when your hands are wet.  
from outlet.  
®
The Ionic Pro ionic air purifier is an electrical appliance. Adult supervision  
H
Always turn off and unplug this product from outlet before cleaning the  
collection blades.  
®
is required when operating the Ionic Pro ionic air purifier in the presence  
of children.  
H
Always turn off this product when not in use.  
H
H
Do not touch the metal blades until after discharging residual electricity by  
touching blades to an electrical ground such as a water pipe or metal faucet.  
H
Never touch the internal parts, such as electrodes, ionizing wires, or any internal  
part within the Ionic Pro ionic air purifier with any object.  
®
The collection blades should be inspected frequently and cleaned regularly  
to prevent excessive accumulation that may result in an electrical flashover or  
risk of fire.  
2
3
SAFETY INSTRUCTIONS  
SAFETY INSTRUCTIONS  
 
IP_CA500_Mnl_Rev_092707.qxp:Layout 1 6/3/08 2:56 PM Page 6  
IMPORTANT WARNINGS  
G.  
F.  
Main Parts  
Before using your Ionic Pro® ionic air  
purifier, please read the following  
important information.  
the unit, see Diagram B or F for the loca-  
tion of the Wire Cleaning Mechanism. Lift  
and lower the Wire Cleaning Mechanism  
three to four times to thoroughly clean the  
internal ionizing wires (see Diagram H in  
the “CLEANING & MAINTENANCE” section).  
This movement helps to scrape free particles  
from the internal ionizing wires. To keep  
COLLECTION  
BLADES’ HANDLE  
C.  
First, please look at the “Main Parts”  
diagram and locate the part labeled A.  
These are the collection blades and  
are a vital part of this amazing ionic air  
purifying system.  
®
your Ionic Pro ionic air purifier working  
properly, it will be necessary to clean the  
collection blades after every month of use  
and the internal ionizing wires after every  
two weeks of use (see “CLEANING & MAINTE-  
NANCE” and “DEEP CLEANING” section of this  
manual for the proper techniques).  
The collection blades are where  
unhealthy pollutants, allergens, irritants  
and odors are trapped when the Ionic  
®
Pro ionic air purifier is in proper  
working condition and in use.  
®
The Ionic Pro ionic air purifier is  
designed to run quietly and requires very  
little time and effort to maintain in  
WARNING: After cleaning the collection blades  
(see “CLEANING AND MAINTENANCE” section) with  
soap and water, allow at least 24 hours for the  
A. COLLECTION BLADES  
proper working condition. If you hear  
excessive noise or static coming from your  
collection blades to dry thoroughly before inserting them  
back into the unit. Water can easily get trapped along the  
collection blades’ many surfaces and edges and damage  
could result if there is any moisture on the collection  
blades. To allow for virtually uninterrupted air purification,  
a second set of collection blades may be purchased (kept  
clean and in its box when not in use) and inserted into the  
Ionic Pro® ionic air purifier while the original collection  
blades are drying.  
®
Ionic Pro ionic air purifier, it generally  
TOP OF COLLECTION BLADES.  
See A for view of  
indicates that the product needs to be  
®
collection blades alone.  
cleaned. Turn off your Ionic Pro ionic air  
D.  
purifier, unplug the cord and carefully  
follow the cleaning instructions in the  
“CLEANING & MAINTENANCE” section of  
this manual.  
REMOVABLE CAP  
C. OUTER CASE HOUSING  
D. AC CORD  
E.  
You will need to clean your Ionic Pro® air purifier more  
often if it has been exposed to heavy pollution.  
E. BASE  
If the product is still making excessive  
noise after cleaning and thoroughly drying  
the collection blades and re-inserting  
them as described in the “CLEANING &  
MAINTENANCE” section of this manual,  
turn off and unplug the unit. After you  
have turned off and unplugged  
F. WIRE CLEANING MECHANISM  
G. REMOVABLE CAP  
Do not place Ionic Pro® ionic air purifier near a fireplace. Even if a fireplace is not in use, chimney dust and soot may  
circulate through the Ionic Pro® ionic air purifier and then re-circulate and leave a residue on the unit and surrounding  
areas. We recommend not placing the Ionic Pro® ionic air purifier anywhere near candles or oil lamps. If you intend to  
use candles or oil lamps near the Ionic Pro® ionic air purifier despite this warning, make sure that the wicks are cut to  
no more than a quarter inch to cut down on smoke production.  
WIRE CLEANING  
MECHANISM  
B. OPERATING PANEL  
4
5
IMPORTANT WARNINGS  
IMPORTANT WARNINGS  
 
IP_CA500_Mnl_Rev_092707.qxp:Layout 1 6/3/08 2:56 PM Page 8  
OPERATING THE IONIC PRO®  
Getting Ready  
Controls/Settings  
®
Locate a level surface on which to place your Ionic Pro ionic air purifier and a  
grounded 120v outlet (follow warnings described in the “SAFETY INSTRUCTIONS”  
section of this manual). Position your Ionic Pro ionic air purifier at least one foot  
1. ON/OFF BUTTON  
Turns unit on and off.  
®
(12 inches) from the wall.  
2. LO  
Recommended for smaller rooms, this is the  
most cost-effective setting. At this setting,  
the unit will experience longer rest intervals  
than on the other two settings (MED or HI).  
(low output indication light)  
®
Plug in the unit. You are now ready to turn on your Ionic Pro ionic air purifier!  
7. REMOVABLE CAP  
6. WIRE CLEANING  
3. MED  
Recommended for average-sized rooms where  
windows and doors are rarely opened. At  
this setting, the unit will experience shorter  
rest intervals than when on the LO setting  
but higher rest intervals than when on the  
HI setting.  
(medium output indication light)  
MECHANISM  
3. MEDIUM OUTPUT  
INDICATION LIGHT  
4. HIGH OUTPUT  
INDICATION LIGHT  
4. HI  
This maximum output setting is recommended  
for large rooms and/or area exposed to heavy  
dust.  
(high output indication light)  
5. CLEAN  
This red light goes on when your  
Ionic Pro ionic air purifier needs to be cleaned,  
or the unit is experiencing some other  
problem. See the “CLEANING & MAINTENANCE”  
and “TROUBLE-SHOOTING” sections.  
2. LOW OUTPUT  
INDICATION LIGHT  
5. CLEAN INDICATION  
LIGHT  
®
(indication light)  
6. WIRE CLEANING MECHANISM This is used to clean the internal ionizing wires.  
See “CLEANING & MAINTENANCE” for full details.  
7. REMOVABLE CAP  
Lift off the Removable Cap to locate collection  
blades for cleaning. See the “CLEANING &  
MAINTENANCE” section.  
1. ON/OFF BUTTON  
HELPFUL TIPS: In general, LO is the most cost-effective setting and is recommended for smaller rooms. MED is  
recommended for rarely opened average-sized rooms. HI delivers maximum output and is recommended for  
larger rooms (the scent of ozone at this setting may be too strong for smaller rooms).  
6
7
OPERATING THE IONIC PRO® IONIC AIR PURIFIER  
OPERATING THE IONIC PRO® IONIC AIR PURIFIER  
 
IP_CA500_Mnl_Rev_092707.qxp:Layout 1 6/3/08 2:56 PM Page 10  
CLEANING & MAINTENANCE:  
®
Operation  
With very little effort, the Ionic Pro ionic air purifier delivers cleaner, fresher,  
®
healthier air to your indoor environments.  
Set up the Ionic Pro ionic air purifier as described in “Getting Ready”. Press the  
ON/OFF button to activate your ionic air purifier and get ready to enjoy clean,  
ionized air that cycles through pre-programmed run/rest intervals according to the  
setting you select.  
®
Keep your Ionic Pro ionic air purifier functioning properly by cleaning the  
collection blades after every month of use as recommended. The internal ionizing  
wires are an important part of the Ionic Pro air purifying system and need  
to be cleaned after every two weeks of use or if your unit starts to make a buzzing  
®
®
The Ionic Pro ionic air purifier automatically defaults to the HI (high/maximum  
noise (see “TO CLEAN IONIZING WIRES” and “DEEP CLEANING” sections).  
output) setting whenever the unit is turned on.  
®
More frequent cleaning is often required if your Ionic Pro ionic air purifier is new  
Just press the ON/OFF button one more time to select the MED (medium)  
output setting to enjoy intermittent run/rest periods and press the ON/OFF  
button once again if you wish to select the LO (low) output setting for the most  
cost-effective run/rest cycle.  
®
or if you place it in a different location. Exposing your Ionic Pro ionic air purifier  
to candle/oil lamp/fireplace soot and smoke is not recommended and will require  
the collection blades to be cleaned after every exposure (see “IMPORTANT WARNINGS”).  
Press the ON/OFF button a fourth time to turn  
the unit off.  
The indicator LEDs light up to  
indicate your current setting (LO, MED, HI).  
Clean Light:  
The red CLEAN light will turn on and the unit  
will shut down if cleaning is overdue.  
®
The Ionic Pro ionic air purifier’s collection blades  
must be cleaned after every month of use and the  
internal ionizing wires must be cleaned after  
every two weeks of use (see “CLEANING & MAINTE-  
NANCE” for full directions). Once the collection  
blades are properly cleaned, thoroughly dried and  
®
re-inserted into your Ionic Pro ionic air purifier  
and the internal ionizing wires are properly  
cleaned, normal operations should continue. If  
not, see “DEEP CLEANING” and “TROUBLE-SHOOTING.”  
UNIT  
8
9
OPERATING THE IONIC PRO® IONIC AIR PURIFIER  
CLEANING & MAINTENANCE  
 
IP_CA500_Mnl_Rev_092707.qxp:Layout 1 6/3/08 2:56 PM Page 12  
HELPFUL TIPS: Remember to clean your Ionic Pro® ionic air  
purifier every month and any time the red CLEAN/FAULT light  
comes on or whenever you hear your unit begin to make  
excessive noise.  
To Clean the Ionizing Wires  
The internal ionizing wires need to  
be cleaned after every two weeks  
of use. There is a Wire Cleaning  
Mechanism used to clean the internal  
ionizing wires which you slide up and  
down to scrape off particle residue.  
(see Diagram B of the Operating  
Panel to locate the Wire Cleaning  
Mechanism). Lift and lower the Wire  
Cleaning Mechanism three or four  
times to thoroughly clean the ionizing  
wires (see Diagram H).  
To Clean the Collection Blades  
®
Turn off and unplug your Ionic Pro air  
purifier. Let the unit rest a minute. Next, lift  
off the removable cap and slide the collection  
®
blades out of the top of your Ionic Pro ionic  
air purifier.  
Do not touch the metal blades until after  
discharging residual electricity by touching  
blades to an electrical ground such as water  
pipe or metal faucet. Wipe away the trapped  
particles collected on the three blades with a  
slightly damp sponge or cloth. If you use a  
slightly damp cloth to clean the blades, it is  
possible the collection blades will be  
REMEMBER TO ALWAYS RETURN THE WIRE  
CLEANING MECHANISM TO ITS ORIGINAL POSITION  
BEFORE ATTEMPTING TO RESUME USE OR THE  
UNIT WILL NOT FUNCTION.  
completely dry within two to three hours.  
Always allow the collection blades to dry  
thoroughly before resuming use.  
COLLECTION BLADES  
®
IMPORTANT: To avoid damaging your Ionic Pro ionic air purifier, make sure the  
collection blades are completely dry and free of all moisture and that your Ionic  
®
Pro ionic air purifier is turned off and unplugged before attempting to re-insert the  
collection blades.  
If you have used soap and water to clean the collection blades, wait at least 24  
hours to ensure that they are thoroughly dry before re-inserting them into your  
®
Ionic Pro ionic air purifier.  
H. CLEANING WIRES  
10  
11  
CLEANING & MAINTENANCE  
CLEANING & MAINTENANCE  
 
IP_CA500_Mnl_Rev_092707.qxp:Layout 1 6/3/08 2:56 PM Page 14  
TROUBLE-SHOOTING  
TROUBLE  
REASON  
TROUBLE-SHOOTING  
Deep Cleaning  
®
Noisy functioning (audible loud buzzing sound) is a sign that your Ionic Pro  
Indication/Setting light  
not on  
Machine is unplugged.  
ON/OFF button has not  
been pressed.  
Check if plug is loose.  
Press the ON/OFF  
button.  
ionic air purifier is overdue for a complete clean-up of the collection blades and  
the internal ionizing wires. The internal ionizing wires must be kept clean to  
ensure silent and normal operation.  
Red CLEAN light is on  
Too much dust has  
accumulated.  
Turn off, unplug and clean  
using instructions from the  
“Deep Cleaning” section.  
For deep cleaning, follow both the “TO CLEAN THE COLLECTION BLADES”  
& “TO CLEAN IONIZING WIRES” sections.  
IMPORTANT: MAKE SURE THE THOROUGHLY CLEANED AND DRIED COLLECTION BLADES ARE PROPERLY  
INSERTED, THE REMOVABLE CAP IS BACK IN ITS ORIGINAL POSITION, AND THE WIRE CLEANING MECHANISM  
IS BACK IN ITS ORIGINAL POSITION BEFORE RESUMING USE—OR THE UNIT WILL NOT FUNCTION.  
Collection blades  
are jarred or removed  
suddenly.  
Remove and re-insert  
collection blades  
and press "on"  
Cleaning External Surfaces  
button to reset.  
Over time, some particles and dust may accumulate on the external surfaces of  
Press “on” button to reset.  
Red light may go on  
if the unit just needs  
to be “reset.”  
®
your Ionic Pro ionic air purifier. If this happens, turn off and unplug the unit. Mix  
one ounce of laundry bleach with five ounces of water and apply sparingly with a  
sponge to wipe the outer case surfaces. Do not allow water to slip into the internal  
®
parts of the Ionic Pro ionic air purifier as this could damage its functioning and  
Excessive noise  
generated*  
Too much dust has  
accumulated or internal  
parts are wet.  
Clean and dry blades  
and ionizing wires  
thoroughly*. Keep the  
machine dry.  
may result in injury to you. Allow the unit to dry for at least 24 hours before  
resuming use.  
Collection blades do not  
go back in  
Improper blade orientation  
Reverse blade orientation  
Check to see that the  
blades are completely  
seated in housing.  
Indication light does not  
go on  
Collection blades are not  
completely inserted.  
Check to see that Wire  
Cleaning Mechanism  
is completely seated in  
housing.  
Wire Cleaning Mechanism is  
not completely inserted  
*See “Cleaning & Maintenance” section  
12  
13  
CLEANING & MAINTENANCE  
TROUBLE-SHOOTING  
 
IP_CA500_Mnl_Rev_092707.qxp:Layout 1 6/3/08 2:56 PM Page 16  
MORE THINGS YOU SHOULD KNOW  
LIMITED ONE YEAR WARRANTY  
Ozone and Your Health  
®
®
After you activate your Ionic Pro ionic air purifier, you may notice a new  
Your Ionic Pro ionic air purifier is warranted to be free from defects in materials  
clean scent.  
and workmanship for one year from the original purchase date. Should the product  
have a defect in materials or workmanship, we will repair or replace it without  
charge to you (a shipping and processing fee may apply). To obtain service under  
warranty, simply call our Customer Service Center toll-free at 1.800.875.8577.  
Ozone is the scent you are smelling. Ozone is a combination of three oxygen  
atoms. The Ionic Pro air purifying system utilizes an ionizing process which  
results in very low ozone emission.  
®
This warranty does not cover damage caused by accident, misuse or any use other  
than as intended and described in this product manual, or damage resulting from  
failure to maintain and clean this product as specified in this product manual. This  
®
The Ionic Pro ionic air purifier complies with U.S. safety requirements for low  
ozone emission (less than 50 parts per billion) and meets the UL867 standard  
for consumer products. UL867 is the U.L. standard for safety for electro-static  
air cleaners.  
®
warranty applies only to the original purchaser of the Ionic Pro ionic air purifier.  
Individuals with a history of respiratory disease, asthma, heart disease, lung disease,  
breathing problems or concerns about ozone should ask their doctor whether the  
concentrations of ozone generated by this or other commercial ionic air purifiers are  
appropriate for their specific health needs.  
Contact Info for Warranty Service:  
Ordering Extra Collection Blades  
Enjoy virtually uninterrupted air purification by ordering an extra set of collection  
blades today.  
Ionic Pro  
P.O. Box 36544  
Los Angeles, CA 90036  
1.800.875.8577  
This way you can always have a clean and thoroughly dry set of collection blades  
available to insert into your Ionic Pro ionic air purifier whenever the other blades  
®
are being cleaned and dried for 24 hours.  
Visit our website at www.ionicpro.com or call 1.800.875.8577 to order your new  
collection blades today.  
©2005-2007 Ionic Pro, LLC. All Rights Reserved.  
U.S. PATENT NOS. D495,042; D505,488; D522,116;  
6,855,190; 6,946,103; AND 6,977,008.  
CHINESE PATENT NO. ZL03353322.9; ZL200420006826.0;  
ZL200420077199.X AND ZL200620004930.5.  
HONG KONG PATENT NOS. HK1063973; HK1066437;  
AND HK1082896. ADDITIONAL PATENTS PENDING.  
14  
15  
MORE THINGS YOU SHOULD KNOW  
LIMITED ONE YEAR WARRANTY  
 
IP_CA500_Mnl_Rev_092707.qxp:Layout 1 6/3/08 2:56 PM Page 18  
ARBITRATION AGREEMENT  
NOTES  
THIS ARBITRATION AGREEMENT (THE “AGREEMENT”) AFFECTS YOUR LEGAL RIGHTS AND REMEDIES BY PRO-  
VIDING THAT DISPUTES BETWEEN YOU AND THE SELLER OF THIS PRODUCT (“COMPANY”), MUST BE  
RESOLVED THROUGH BINDING ARBITRATION, RATHER THAN IN A COURT. PLEASE READ THIS AGREEMENT  
CAREFULLY. YOU ACCEPT THE TERMS OF THIS AGREEMENT BY RETAINING THE PRODUCT(S) SHIPPED IN CON-  
NECTION WITH THIS AGREEMENT (THE “PRODUCT”) FOR MORE THAN FOURTEEN (14) DAYS AFTER RECEIPT. IF  
YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT, YOU MAY RETURN THE PRODUCT TO COMPANY  
WITHIN FOURTEEN (14) DAYS OF RECEIPT AT NO COST TO YOU.  
1. RESOLUTION OF CLAIMS OR DISPUTES. Any claim or dispute between you and Company (or any of Company’s  
subsidiaries or affiliates) arising out of or relating in any way to the Product or this Agreement shall be resolved  
through final, binding arbitration. This arbitration obligation applies regardless of whether the claim or dispute involves  
a tort, fraud, misrepresentation, product liability, negligence, violation of a statute, or any other legal theory. Both you  
and Company specifically acknowledge and agree that you waive your right to bring a lawsuit based on such claims  
or disputes and to have such lawsuit resolved by a judge or jury.  
2. LIMITATION OF LEGAL REMEDIES. All arbitrations under this Agreement shall be conducted on an individual (and  
not a class-wide) basis, and an arbitrator shall have no authority to award class-wide relief. You acknowledge and  
agree that this Agreement specifically prohibits you from commencing arbitration proceedings as a representative of  
others or joining in any arbitration proceedings brought by any other person.  
3. ARBITRATION PROCEDURES.  
a. Before commencing any arbitration proceedings under this Agreement, you must first present the claim or dispute  
to Company by calling 818-217-2500 and asking for the Legal Department and allowing Company the opportunity to  
resolve the claim or dispute. If your claim or dispute is not resolved within sixty (60) days, you may commence arbi-  
tration proceedings in accordance with the terms of this Agreement.  
b. The arbitration of any claim or dispute under this Agreement shall be conducted pursuant to the American  
Arbitration Association’s (AAA) United States Commercial Dispute Resolution Procedures and Supplementary  
Procedures for Consumer-Related Disputes. These rules and procedures are available by calling the AAA or by visit-  
c. The arbitration of any claim or dispute under this Agreement shall be conducted in the State of California or the  
location in which you received this Agreement.  
d. All administrative expenses of arbitration proceedings commenced under this Agreement shall be divided equally  
between you and Company, except that: (a) if the claim or dispute that is the subject of the arbitration proceedings is  
less than ten thousand dollars (US$10,000), you will be responsible for no more than one hundred twenty-five dollars  
(US$125) in administrative expenses; (b) if the claim or dispute that is the subject of the arbitration proceedings is  
more than ten thousand dollars (US$10,000) but less than seventy-five thousand dollars (US$75,000), you will be  
responsible for no more than three hundred seventy-five dollars (US$375) in administrative expenses; and (c) if the  
claim or dispute that is the subject of the arbitration proceedings is more than seventy-five thousand dollars  
(US$75,000), then you will be responsible for administrative expenses in accordance with the Commercial Fee  
Schedule provided by the AAA. You acknowledge and agree that each party shall pay the fees and costs of its own  
counsel, experts and witnesses.  
4. CHOICE OF LAW. This Agreement shall be governed by the United States Federal Arbitration Act and the laws of  
the state of California.  
5. SEVERABILITY. If any provision of this Agreement is declared or found to be unlawful, unenforceable or void, such  
provision will be ineffective only to the extent that it is found unlawful, unenforceable or void, and the remainder of the  
provision and all other provisions shall remain fully enforceable.  
16  
17  
NOTES  
ARBITRATION AGREEMENT  
 
IP_CA500_Mnl_Rev_092707.qxp:Layout 1 6/3/08 2:56 PM Page 20  
IPMN09707  
 

Indesit Refrigerator BIAA 10 XX UK User Manual
Jensen Speaker XS1010 User Manual
Jura Capresso Coffeemaker Impressa F9 User Manual
JVC Stereo System UX QX3A User Manual
Kawasaki Grinder 840109 User Manual
Kenmore Gas Grill 12216641900 User Manual
Kenmore Vacuum Cleaner 11627614 User Manual
Kenwood Car Amplifier KA 892 User Manual
Kenwood Turntable P T400 User Manual
Kettler Elliptical Trainer 07652 000 User Manual