John Lewis Ventilation Hood JLBIHD105 User Manual

JLBIHD105  
built-in cooker hood  
Instruction manual  
 
Contents  
For the User  
For the Installer  
Important Safety Information  
Description of the Appliance  
2
4
Electrical Connections  
Electrical Requirements  
Electrical Connection  
9
9
9
Using the cooker hood  
Cooker Hood Controls  
To Operate  
Recirculation  
Extraction  
10  
10  
10  
10  
10  
Installing the Cooker Hood  
Installation Requirements  
Unpacking  
Fitting theWall Brackets  
Fitting the Canopy Hood  
Extraction  
5
5
5
6
6
7
7
8
Maintenance and Cleaning  
External Cleaning  
Grease Filters  
Charcoal Filters  
To Remove/Replace Charcoal Filter  
Changing the Light Bulb  
11  
11  
11  
12  
12  
12  
Recirculation  
Fitting the Chimney Stack  
Something NotWorking  
Repairs and After Sales Service  
Spare Parts  
13  
13  
14  
Guide to use the Instruction Manual  
The following symbols will be found in the text to guide  
you through the instruction book  
Safety instructions  
Step by step instructions  
Environmental Information  
This appliance complies with the fol-  
lowings E.E.C. Directives:  
- 89/336 (Electromagnetic Compat-  
ibility Directive)  
- 73/23 (LowVoltage Directive)  
- 93/68 (General Directives)  
and subsequent modifications  
3
 
Description of the Appliance  
132  
100  
300  
150  
4
 
Installation  
Please ensure that when the appliance is installed  
it is easily accessible to an engineer in the event  
of a breakdown.  
All installations must comply with the local  
authorities requirements for the discharge of  
exhaust air.  
Incorrect installation may affect the safety of  
this cooker hood.  
Installation Requirements  
Before installation check the wall to which  
the cooker hood is to be fitted for electric  
cables, water pipes or gas.  
This cooker hood is designed to be fixed to any vertical  
surface over a cooking area,and can be used in the extrac-  
tion (ducted to the outside) or recirculation mode.  
The installation work must be undertaken by a qualified  
and competent person.  
The manufacturer disclaims any responsibility for dam-  
age due to incorrect installation of the cooker hood or  
if the hood is not installed in compliance with relevant  
regulations controlling this type of installation.  
15  
Unpacking  
Before unpacking the cooker hood position the carton  
with the arrows pointing upwards as illustrated on the  
carton.  
14.1  
The cooker hood is made up of the following compo-  
nents:  
7.2.1  
14  
10  
Ref Qty Product Components  
1
1
Canopy complete with: Controls, Light-  
ing, Fan Assembly, Grease Filter, Charcoal  
Filter.  
9
2
1
1
1
1
1
1
1
1
2
1
Telescopic Chimney comprising:  
Upper Chimney Stack  
Lower Chimney Stack  
Right-Hand Recirculation grille  
Left-Hand Recirculation grille  
ø150-120 Ducting Spigot  
ø120-125 Ducting flange  
Ducting Extension Pipe  
Recirculation Outlet Extentions  
Recirculation Outlet Adapter  
2.1  
2.2  
8a  
8b  
9
10  
14  
14.1  
15  
2.1  
12c  
8a  
2
8b  
2.2  
Ref Qty Installation Components  
7.2.1  
12c  
2
6
Upper chimney wall fixing brackets  
Chimney fixing screws  
Ref Qty Documentation  
Instruction booklet  
1
1
5
 
Installing the Cooker Hood  
Fitting theWall Brackets  
Draw a vertical line on the supporting wall up to the  
ceiling, or as high as practical, at the centre of the area  
in which the hood will be installed.  
Draw a horizontal line at 650 mm above the hob.  
Place bracket item 7.2.1 on the wall as shown about 1-2  
mm from the ceiling or upper limit aligning the centre  
(notch) with the vertical reference line.  
7.2.1  
Mark the wall at the centres of the holes in the brack-  
et.  
Place bracket item 7.2.1 on the wall as shown at X mm  
below the first bracket (X = height of the upper chim-  
ney section supplied), aligning the centre (notch) with the  
vertical line.  
116 116  
Mark the wall at the centres of the holes in the brack-  
et.  
Draw a horizontal line through the vertical at 340 mm  
above the hob and mark two hole centres at 116 mm  
either side of the vetical line.  
Drill ø 8 mm holes at all the centre points marked.  
Insert the wall plugs (not supplied) in the holes.  
Fix the brackets using the screws (not supplied).  
Insert two screws into the two holes 116 mm either side  
of the vertical line and tighten leaving a space between  
the underside of the screwhead and the wall of 5-6mm.  
Note: If the hood is to be installed onto a hollow  
construction or plaster or partition board wall  
then special fixing screws will be required (not  
supplied).  
Vr  
Fitting the Canopy Hood  
Before starting to fix the hood body, tighten the two  
screws item Vr located on the top of the hood body.  
Hook the hood body onto the two screws item 12a.  
Fully tighten the screws item 12a.  
Using a screw driver and spirit level, adjust the screws  
item Vr until the hood body is level.  
12a  
6
 
Extraction (Ducted)  
The cooker hood is more effective when installed in the  
extraction mode (ducted to the outside).  
Venting kits may be purchased through your retailer or  
DIY store, and must be evacuated through an outside  
vent of ø125 (5ins) or ø150mm (6ins).  
The ducting used must be manufactured from fire  
retardent material conforming to the relevant British  
Standard or DIN 4102-B1.  
When the cooker hood is ducted to the outside  
the charcoal filter must be removed.  
Fitting the Ducting  
Fit the ø150mm (6ins) ducting to the spigot on top of  
the hood body as illustrated.  
When using ø125mm (5ins) ducting fit item 9 and 10  
on to the spigot on the top of the hood body as illus-  
trated.  
ø 125  
ø 150  
For the best performance use the shortest possible run  
of ducting and we recommend the use of rigid pipe in  
preference to flexible hose as this will improve the flow  
of air while reducing turbulence, which causes noise and  
a loss of performance.  
If the room where the cooker hood is to be used contains  
a fuel burning appliance such as a central heating boiler,  
then its flue must be be of the room sealed or balanced  
flue type.  
10  
9
If other types of flue or appliances are fitted ensure that  
there is an adequate supply of air to the room.  
The cooker ducting when fitted in the extraction mode  
must never be connected to central heating flues, radiators  
or water heaters.  
Recirculation Mode  
The cooker hood is supplied specified for use in the recircula-  
tion mode, with the charcoal filter fitted.  
15  
14.1  
In the recirculation mode contaminated air is passed through  
the charcoal filter to be purified and recirculated into the kitch-  
en through the grille outlets on either side of the chimney.  
8b  
8a  
Assemble the two halves of the ducting extension pipe  
item 14.  
Push-fit the extension pipe on to the ducting spigot on  
top of the canopy.  
Push-fit the recirculation adapter item 15 on to extension  
pipe item 14.  
Insert the recirculation outlet extensions item 14.4 into  
the recirculation adapter item 15.  
14  
The recircualtion grilles item 8a and 8b must be fitted  
after the lower chimney item 2.2 has been fitted.  
Ensure the activated charcoal filter has been fitted.  
7
 
Fitting the Upper Chimney  
Expand the sides of the upper chimney stack item 2.1 and  
place the chimney over the two brackets 7.2.1 ensuring  
they are well seated.  
Secure the chimney stack to the brackets 7.2.1 using  
the four self tapping screws item 12c (2.9 x 9.5mm)  
supplied.  
7.2.1  
12c  
2.1  
2
Fitting the Lower Chimney  
8b  
2.2  
8a  
Expand the of the lower chimney stack item 2.2 and place  
the chimney over the upper chimney stack item 2.1 and  
the canopy.  
Secure the chimney stack to the canopy using the two  
screws item 12c (2.9 x 9.5mm) supplied..  
After the chimney has been secured into position, insert  
the two plastic recirculation grilles item 8a (right-hand)  
and 8b (left-hand) in the apertures on each side of the  
chimney. The grilles are marked with two arrows and  
should be fitted with one arrow pointing upwards and  
the other toward the front.  
12c  
When the hood is used in the recirculation mode ensure  
that the grilles are properly secured to the recirculation  
extension spigot item 14.1.  
8
 
Electrical Connections  
THIS APPLIANCE MUST BE EARTHED  
Electrical Requirements  
Any permanent electrical installation must comply with  
the latest I.E.E. Regulations and local Electricity Board  
regulations. For your own safety this should be under-  
taken by a qualified electrician e.g. your local Electricity  
Board,or a contractor who is on the roll of the National  
Inspection Council for Electrical Installation Contracting  
(NICEIC).  
Electrical Connection  
Before connecting to the mains supply ensure that the  
mains voltage corresponds to the voltage on the rating  
plate inside the cooker hood.  
Remove the grease filters (see paragraph Maintenance)  
being sure that the connector of the feeding cable is  
correctly inserted in the socket placed on the side of  
the fan.  
This appliance is fitted with a 3 core mains cable and  
must be permanently connected to the electricity supply  
via a double-pole switch having 3mm minimum contact  
gap on each pole.A Switched Fuse Connection Unit to  
BS1363 Part 4, fitted with a 3 Amp fuse, is a recom-  
mended mains supply connection accessory to ensure  
compliance with the Safety Requirements applicable to  
fixed wiring instructions.  
This appliance conforms to BS 800: 1988 and EEC Di-  
rective No. 78 308 regarding suppression of radio and  
television interference.  
9
 
Using the cooker hood  
The cooker hood is designed to extract unpleasant  
odours from the kitchen, it will not extract steam.  
The appliance can be installed to recirculate or extract  
contaminated air.  
Cooker Hood Controls  
The cooker hood functions are controlled by four push  
button switches located centrally in the control fascia.  
L
Turns the worktop lighting On and Off  
L
V1 Motor ON/OFF switch. Depress to turn the  
extractor motor on at a LOW speed, to ensure  
that light cooking vapours are silently extracted.  
V2 Medium speed,suitable for general use. This speed  
provides an optimum treated air flow to noise level  
ratio.  
V3 Maximum speed, used to extract intensive levels  
V1  
V2  
V3  
of cooking vapour emissions.  
To Operate  
Select the required fan speed and light if required.  
Recirculation  
In the recirculation mode the contaminated air enters  
the cooker hood through the grease filters. The air is  
cleaned by passing through the charcoal filters before  
being passed back into the kitchen through the grilles in  
either side of the chimney stack.  
Extraction  
In the extraction mode the contaminated air enters the  
cooker hood passing through the grease filters and is  
passed out through the ducting into the atmosphere.  
To obtain the best performance when cooking it is advis-  
able to switch the cooker hood on for a few minutes  
before you start cooking and leave it running for about  
15 minutes after finishing.  
When used in the ducting mode the charcoal  
filters are not required.  
Never do flambé cooking under this cooker  
hood.  
Never leave frying pans unattended during  
use, as over-heated fats and oils can catch fire.  
Do not leave naked flames under the cooker  
hood.  
Ensure heating areas on your hob are covered  
with pots and pans when using the hob and  
cooker hood simultaneously.  
10  
 
Maintenance and Cleaning  
Before carrying out any maintenance or lean-  
ing isolate the cooker hood from the mains  
supply.  
The cooker hood must be kept clean, as a  
build up of grease or fat can be a fire hazard.  
External cleaning  
Wipe the cooker hood frequently with warm soapy water  
using a mild detergent.  
Never use scouring pads or abrasive cleaners.  
Never use excessive amounts of water when  
cleaning particularly around the control panel.  
Grease Filters  
The Grease Filters absorb grease and dust during cooking  
to help keep the cooker hood clean inside,and should be  
cleaned approximately once every two month or more  
often if the hood is used for more than 3 hours a day.  
Remove the Grease Filters one  
at a time by:  
Supporting them with one hand and turning the safety knobs  
(pull and turn)  
.
The Grease Filters should be washed, by hand, in mild  
soapy water or in a dishwasher. Allow to dry completely  
before replacing.  
Replace them and fix them using the safety knobs pro-  
vided (pull and turn).  
11  
 
Before carrying out any maintenance or  
cleaning isolate the cooker hood from the  
mains supply.  
Charcoal Filters  
In the recirculation mode the charcoal filters absorb  
smells and unwanted odours.  
The charcoal filters cannot be cleaned, we recommend  
they should be replaced approximately every three  
months or more often if the hood is used for more  
than three hours per day.  
To Remove/Replace the Char-  
coal Filters  
First remove the Grease Filters.  
Remove the saturated activated charcoal filter by releasing  
the fixing hooks as illustrated.  
Position the new charcoal filter in the position marked  
and while holding the filter replace the fixing hooks as  
illustrated  
This appliance can be a possible fire hazard if  
the grease and charcoal filters are not cleaned  
and replaced as recommended.  
Changing the Halogen Lamp  
Unscrew the two screws to release the metal sur-  
round.  
Remove the lamp from the holder by pulling the lamp  
downwards.  
Replace the lamp with a new one of the same type, mak-  
ing sure that you insert the two pins properly into the  
housings on the lamp holder.  
Replace the Support, fixing it in place with the two screws  
removed as above.  
Replacement filters and light bulbs can be ob-  
tained from your local Service Force Centre.  
12  
 
Something notWorking  
If the appliance is not working correctly, please carry out the following checks, before contacting your local Service  
Force agent.  
IMPORTANT:If you call out an engineer to a fault listed below, or to repair a fault caused by incorrect use or instal-  
lation, a charge will be made even if the appliance is under guarantee.  
Symptom  
Solution  
The cooker hood will not start  
Check the hood is connected to the electricity supply.  
Make sure the switch is in the ‘ON’ position.  
The cooker hood is not working effectively  
Check that the fan speed is set high enough for the task  
Ensure the grease filter is clean.  
Ensure the kitchen is adequately vented to allow the entry  
of fresh air.  
If set up for recirculation, check that the charcoal filter is  
still effective.  
If set up for extraction,check that the ducting and outlets  
are not blocked.  
The cooker hood has switched off during  
operation  
The safety cut-out device has been tripped.  
Tum off the hob and then wait for the device to reset.  
Repairs and After Sales Service  
In the event of your appliance requiring service, or if you  
wish to purchase spare parts, please contact our extended  
warranty administrators by telephoning:  
0870 01 07887  
They will give you details for your local Service Force  
Centre.  
Before calling out an engineer,please ensure you have read the  
details under the heading “Something NotWorking”.  
Your appliance is covered by a 3 year parts and labour  
guarantee (see separate details given at point of sale). Please  
retain your purchase receipt safely for the service engineer to  
verify the purchase details.  
When you contact the Service Force Centre you will need to  
give the following details:  
1. Your name, address and post code  
2. Your telephone number  
3. Clear and concise details of fault  
4. The model and serial number of the appliance (found on  
the rating plate located near the motor inside the hood  
- see picture)  
5. The purchase date.  
Please note that a valid purchase receipt is required for in-  
guarantee service calls.  
13  
 
Spare parts  
This product should be serviced by any authorised service  
engineer; and only genuine spare parts should be used.  
Under no circumstances should you attempt to repair the  
hob yourself.  
Repairs carried out by inexperienced persons may cause  
injury or serious malfunctioning. Contact our extended  
warranty administrators on  
0870 01 07887  
who will give you details for your Service Force repair agent.  
Always insist on genuine spare parts.  
Rating Plate  
14  
 
 
John Lewis Partnership  
171 Victoria Street  
London SW1E 5NN  
436003485_02 - 060822  
0806  
 

Invacare Nebulizer IRC 1710 User Manual
Jasco Home Security System 57885 User Manual
JBL Speaker GT4 User Manual
JVC Speaker SX WD10 User Manual
Jwin Bluetooth Headset JB TH220 User Manual
Kathrein Air Compressor HDS 150 User Manual
Kathrein Satellite TV System UFS 922 si User Manual
Kenmore Washer Dryer 1102706 User Manual
Kenwood Satellite Radio H2EV User Manual
Kodak Camera Accessories AS 75 User Manual