Lytecaster Recessed Downlighting 1002P1
Page 1 of 1
5" Aperture Incandescent Standard Frame-In Kit
6
1
2
3
5
4
Ceiling Opening
Complete Fixture consists of Reflector Trim & Frame-In Kit. Select each separately.
Frame-In Kit Reflector Trims — See Individual Reflector Trim Specification Sheets
Open Downlight
Recessed
Satin
Cone
Baffles
Basic
White
Pinhole Adjustable Eyeball
Enclosed
Diffusers
Wall
Washer
Open
Wet Location
Reflector
Cone
1002P1
1045
1046
1046CD
1012
1012NM
1013
1013NM
1013BK
1013BKNM
1013CD
1013CDNM
1008
1005
1071
1011
1027
1023
1023WH
1082
1022
1022WH
1024
1078
1090
1021
1035
1084CD
1008NM 1005WH
1010 1005NM
1010NM 1005BNM
1076
1027BK
1027WH
1027CD
1027NM
1027BNM
1027BKNM
1027CDNM
1038
1035WH 1084WH
1085
1095
1096
1076WH
1096CD
1038NM
1048
1048NM
Features
Options & Accessories (continued)
1. Mounting Frame: .036" (#20 ga.) galvanized steel. Accommodates all ceilings
up to 1" thick. Four slots are positioned 90° apart to simplify alignment. Push-in/
twist-out rotoclips hold reflector flush to ceiling.
Remodeler Anchor Clip:
Conversion Kit
1985N
1910CKU - Reference conversion kit
specification sheet for trim and lamp options.
2. Junction Box: 4" x 3 1/2” x 2”; .063" (#14 ga.) galvanized steel. U.L. listed for
maximum of 8 No. 12 ga. 75° C through branch circuit conductors (60° C end
of run). Integral cable clamps permit attachment of nonmetallic Romex® or
armored cable without need of additional connectors.
Labels
UL (Suitable for Damp Locations), I.B.E.W.;
3. Mounting Bars: .059" (#16 ga.) galvanized steel. 13" long bars extend to 27"
with integral nailing tabs. Attaches to wood joist without need of accessories.
4. Socket Housing: Impact extruded aluminum or galvanized steel.
5. Socket: Porcelain medium base; nickel plated screw shell. Pre-wired with #18
ga. SF1 leads to junction box.
Romex® is a registered trademark of General Cable Industries Inc.
US Patent No's.: 5,045,985
Job Information
Type:
6. Thermal Protector: Meets NEC and UL requirements. Insulation must be kept
3“ away from fixture sides and wiring compartments and must not be placed
above fixture in a manner which will entrap heat.
Job Name:
Cat. No.:
Options & Accessories
Lamp(s):
Notes:
Mounting Bars:
1964 - 20" set of (2)
1956 - set of (4)
1960 - 7/8" depth for wet plaster ceilings.
T-Bar Anchor Clips:
Plaster Ceiling Ring:
Extra-Thick Ceiling
Mounting Ring:
1967B - up to 2" thick ceilings.
277V Remote Step-Down
Transformer:
7997 - 277V down to 120V
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
300W max. load.
Lightolier is a Philips group brand
|