Lightolier Work Light C4T4W User Manual

Calculite® HID Wall Wash C4T4W  
Page 1 of 2  
4 1/2" Aperture, T4.5 Ceramic Metal Halide  
5
1
2
4
3
6
8
9
10  
7
20" (508 mm) to  
30" (762 mm)  
8-7/8" (226 mm)  
Vertical Adjustment:  
5/8" (16 mm) to  
2 7/8" (73 mm)  
7-1/2"  
(190 mm)  
Top View  
4-1/4" (108 mm) Dia.  
2" (50 mm) max.  
Ceiling Thickness  
5-1/2" (140 mm) Dia.  
Ceiling Cutout: 5 1/8” (130 mm) Dia.  
Reflector Trim  
Frame-In Kit  
Lamp  
C420T4E1  
C420T4E2  
C439T4E1  
C439T4E2  
C470T4E1  
C470T4E2  
Electronic 120V  
Electronic 277V  
Electronic 120V  
Electronic 277V  
Electronic 120V  
Electronic 277V  
20W T4.5 Ceramic MH  
20W T4.5 Ceramic MH  
39W T4.5 Ceramic MH  
39W T4.5 Ceramic MH  
70W T4.5 Ceramic MH  
70W T4.5 Ceramic MH  
C4T4W  
CLW  
Specular Clear, White Painted Flange.  
Specular Clear, Matching Flange.  
Comfort Clear Diffuse, White Painted Flange.  
Comfort Clear Diffuse, Matching Flange.  
Champagne Bronze, White Painted Flange.  
Champagne Bronze, Matching Flange.  
CLP  
CCDW  
CCDP  
CCZW  
CCZP  
Features  
Electrical  
1. Upper Reflector: Clear anodized aluminum, 0.040” (16 ga.). Provides wide  
beam optics ideal for general lighting and wall washing.  
Electronic Ballast: 120V or 277V, 50/60 Hz., encased, high power  
factor, T.H.D. <15%, thermally and transient protected, RMI/RFI complies with  
FCC Part 18 non-consumer limits, shut-down circuit at end of lamp life, sound  
rating “A”, -5°F minimum starting temperature, Type 1 Outdoor rating.  
2. Downlight/Wall Washer Reflector: Provides vertical surface wall wash-  
ing and downlighting. Low brightness with 50° visual cut-off to lamp and  
lamp image. Self-flanged reflector with white or matching (polished) flange.  
Consult factory for other finishes.  
Ballast  
ANSI Code Voltage Max. Amps Input Watts  
20W MH M156  
39W MH M130  
70W MH M139  
120/277  
120/277  
120/277  
0.21/0.10  
0.39/0.17  
0.67/0.29  
23  
44  
78  
3. Lamp Shield: High temperature glass as required by code, captive during  
re-lamping. Light diffusion provides extremely smooth beam.  
4. Socket Housing: Galvanized steel, pre-wired with G8.5 pulse rated socket.  
Snaps onto reflector/housing for secure attachment without tools. Unitized  
construction assures proper optical alignment of lamp to reflector.  
5. Mounting Frame: 0.048” (18 ga.) galvanized steel. Vertical adjustment  
mechanism accommodates mounting to virtually any ceiling system using  
mounting bars (provided), or 1/2" EMT tubing (by others). Single locking  
feature secures all adjustments. Alignment holes and markings allow  
fixture to be preset prior to installation.  
Options and Accessories  
Chicago Plenum: Consult Factory.  
Labels  
UL (Suitable for Damp Locations), CSA, I.B.E.W.  
For 70W, install fixtures with minimum spacing between:  
1. Center-to center of adjacent luminaries: 2 feet.  
2. Top of luminaire to overhead building member: 1/2 inch.  
3. Luminaire center to side building member: 1 foot.  
6. Mounting Ring: 0.048” (18 ga.) galvanized steel. Designed for vertical  
adjustment from above or below for ceilings from 0” to 2” thick. Center-line  
notches allow consistent alignment of multiple fixtures.  
7. Mounting Bars: 0.048” (18 ga.) galvanized steel. Pre-installed, telescoping  
bars extend to 30” long and lock securely into position. Built-in locking tabs  
provide positive attachment to common T-bar systems. Self-centering feature  
simplifies installation in 24” O.C. grid systems. Attaches to steel or wood  
joists without accessories.  
Job Information  
Type:  
Job Name:  
Cat. No.:  
8. Trim Retention Springs: Rust resistant springs secure reflector/housing  
for quick, tool-less installation.  
9. Ballast / Socket Housing / Cover Assembly: Electronic, snaps onto  
junction box without tools for inspection and ballast replacement, accessible  
from below.  
Lamp(s):  
Notes:  
10. Junction Box: 0.048” (18 ga.) galvanized steel. UL listed for 8 No. 12 AWG,  
90°C through branch circuit conductors. Allows inspection from below.  
11. Thermal Protector: (Not Shown) Meets NEC and UL requirements. Do not  
install insulation above nor within 3" (76mm) of any part of the luminaire.  
Lightolier a Genlyte Thomas Company  
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710  
We reserve the right to change details of design, materials and finish.  
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504  
 

Krell Industries Stereo Amplifier MDA 300 500 User Manual
Lennox Hearth Indoor Fireplace ADK22CMBS User Manual
Lenoxx Electronics Telephone PH 329 User Manual
LG Electronics Dishwasher LDF9810ST User Manual
LG Electronics Log Splitter LSVFSD LP User Manual
Lincoln Convection Oven 1600 000 A User Manual
Logitech Webcam 960000971 User Manual
Makita Power Hammer HM1500 User Manual
Maytag Refrigerator MFI2067AEW User Manual
Middleby Marshall Oven PS740E User Manual