Calculite® HID Lensed Downlight C7E17FL-PL
Prismatic Lens
Fresnel Lens
Page 1 of 2
7" Aperture, ED17 (Enclosed), Ceramic Metal Halide, Fresnel or Prismatic Lens
11
9
2
5
3
1
4
7
8
6
11
12
10
20" (508 mm) to 30" (762 mm)
8-1/4"
(210 mm)
9-3/4"
(248 mm)
8-3/4"
(222 mm)
Top View
(Magnetic Ballast)
Vertical Adjustment:
5/8" (16 mm) to
2 7/8" (73 mm)
20" (508 mm) to
30" (762 mm)
9-3/4"
(248 mm)
11" (280 mm)
(100W)
7-5/16" (187 mm) Dia.
8-5/8" (200 mm) Dia.
2" (50 mm) max.
Ceiling Thickness
Top View
(Electronic Ballast)
Ceiling Cutout: 8" (203mm) dia.
Reflector Trim
C7E17FLWHW
Frame-In Kit
Lamp (Coated, Ceramic MH)
C770MHE1 Electronic, 120V
C770MHE2 Electronic, 277V
C710MHE1 Electronic, 120V
C710MHE2 Electronic, 277V
70W ED17,BD17 (Enclosed)
70W ED17, BD17 (Enclosed)
100W ED17, BD17 (Enclosed)
100W ED17 BD17 (Enclosed)
Fresnel Lens, White Step Baffle, White Flange
Prismatic Lens, White Step Baffle, White Flange
C7E17PLWHW
C770MHU Magnetic, 120V/277V 70W ED17, BD1 (Enclosed)
C710MHU Magnetic, 120V/277V 100W ED17, BD17 (Enclosed)
Features
Electrical
1. Reflector: Semi-Specular anodized aluminum, 16 ga. Removable from inside
fixture for access to splices and ballast.
Electronic Ballast: 120V or 277V, 50/60 Hz., encased, high-power factor, T.H.D.
<15%, thermally and transient protected, RMI / RFI complies with FCC Part 18
non-consumer equipment, shut-down circuit at end of lamp life, sound rating
"A", -5° F minimum starting temperature, Type 1 outdoor rating.
2. Lens: Prismatic (C7E17PLWHW) or Fresnel (C7E17FLWHW) lens. Regressed
1 3/4" from ceiling line.
3. Die-Cast Baffle: Painted white, self flange, deep conical step baffle for
low brightness, supports lens. Small Allen-head set screw provides secure
attachment for use where vandal resistant luminaires are required.
4. Torsiontite Springs: Permit removal of lens assembly without tools.
5. Socket Cup: Galvanized steel, pre-wired with medium base pulse rated
socket. Snaps onto upper reflector for secure attachment without tools;
unitized construction assures proper lamp alignment to optics for consistent
performance.
Ballast
70W MH M98/M143
100W MH M90/M140
Magnetic Ballast: 120V/277V dual voltage, 60 Hz., encased and potted,
HX-HPF circuit type, high power factor, sound rating “B”, -20° F minimum
starting temperature, Type 1 Outdoor rating.
Ballast
70W MH M98/M143
100W MH M90/M140
ANSI Code Voltage Max. Amps Input Watts
120/277
120/277
0.67/0.28
0.90/0.43
78
110
ANSI Code Voltage Max. Amps Input Watts
120/277
120/277
1.90/0.80
2.40/1.10
94
125
6. Mounting Frame: 0.048"(18-ga.) galvanized steel includes pre-installed
mounting bars.
Options and Accessories
7. Mounting Ring: 0.048"(18-ga.) galvanized steel. Designed for vertical
adjustment from above or below for ceilings from 0" to 2" thick. Center-line
notches allow consistent alignment of multiple fixtures.
8. Retaining Springs: Rust resistant simplify reflector housing removal for
inspection and maintenance.
9. Vertical Adjustment Mechanism: Accommodates mounting to virtually
any ceiling system using mounting bars (provided, or 1/2" EMT tubing (by
others). Single locking feature secures all adjustments. Alignment holes and
markings allow fixture to be preset prior to installation.
Auxiliary: Add suffix A to Frame-In Kit and Reflector Trim. See Spec.Sheet “A/E”
Emergency Lamp: Add suffix E to FIK and Reflector Trim. See Spec.Sheet “A/E”
Slope Ceiling Adapters: See Specification Sheet SCA.
Fuse (magnetic ballast): Add suffix F1 or F2 to FIK (F1=120V F2=277V)
Chicago Plenum: Consult Factory.
Labels
UL (Suitable for Wet Locations), CSA, I.B.E.W.
10. Mounting Bars: 0.048" (18-ga.) pre-installed, telescoping bars extend to 30"
long and lock securely into position. Built-in locking tabs provide positive
attachment to common T-bar systems. Self-centering feature simplifies instal-
lation in 24" O.C. grid systems. Attaches to steel or wood joists without
accessories.
Job Information
Type:
Job Name:
Cat. No.:
11.Ballast: Electronic 120V or 277V or dual voltage (120V/277V) magnetic.
Assembly is accessible from below without tools for inspection and
replacement.
12. Junction Box: 0.048" (18-ga.) galvanized steel. UL listed for 8 No. 12 AWG,
90°C through branch circuit conductors; allows inspection from below.
13. Thermal Protector: (not shown) Meets NEC and UL requirements. Do not
install insulation above nor within 3" (76mm) of any part of the luminaire.
Lamp(s):
Notes:
Lightolier a Genlyte company
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte LLC • B0809
|