RJ31X ADAPTER
FOR USE WITH
THE PERS CONSOLES
(760) 438-7000
USA & Canada (800) 421-1587 & (800) 392-0123
Toll Free FAX (800) 468-1340
installation instructions
To provide proper telephone line seizure this cable must be connected to an 8-position telephone
jack installed per FCC Universal Service Order Code RJ-31X or RJ-38X. See Figure 1 for details
of the telephone jack wiring.
A single ended 8-conductor modular line cord is used to connect the PERS console to the
telephone jack.Plug the LINE and PHONE plugs into the appropriate jacks on the PERS console.
See Figure 2. Route the cable away from the jacks via the internal raceway. Then install the
8-position plug into the telephone company jack.
Testing
Test the PERS console by first calling the central station and informing them that a test is going
to be performed.
Trigger an alarm via the remote control or from the large EMERGENCY/HELP button on the
console.Thehousephoneswillbedisconnectedandthecentralstationwillrecievetheemergency
message. If the console is equipped with two-way voice capability the central station may talk via
the console to verify proper operation of the two-way voice system.
After the PERS console goes offline, the house phones will be restored to normal operation.
TELEPHONE
JACK (RJ31X
OR RJ38X)
Example with
PERS-2400A
6
5
1
2
3
4
5
6
4
3
2
1
TO "LINE"
JACK ON
PERS CONSOLE
TO "PHONE"
JACK ON
PERS CONSOLE
CONSOLE WITH
REAR COVER
INSTALLED
8-PIN
MODULAR
PHONE CORD
OTHER WIRES
NOT USED
8-POSITION
USOC RJ31-X
(OR RJ38-X)
JACK
R1
R
T
T1
SHORTING BAR
SHORT REMOVED
ON PLUG
ROUTE CABLES UNDER
STRAIN-RELIEF TABS
1
2
3
4
5
6
7
8
INSERTION
T1
R
T
(PHONE)
CONNECT LOCAL
TELEPHONE TO
THIS JACK
R1
(LINE)
CONNECT TELEPHONE
LINE TO THIS JACK
TO TELEPHONE
NETWORK
TO LOCAL
TELEPHONE
SETS
Figure 2
Figure 1
Copyright © 2005 Linear Corporation
221329 B
|