DCN Flush Mount Control Panels
DCN Microphone Control Panel
Specify Part
Number
The LBB 3537 is a uni-directional, condenser
microphone, mounted on a flush-mounted control
panel by means of a flexible stem. The
LBB 3537/00
LBB 3537/50
microphone has a built-in plop- and windscreen,
as well as a light ring indicator which illuminates
when the microphone is on. The control panel
can be connected to Multi-Purpose Connection
Unit LBB 3540/15, or to one input of the Dual Audio
Interface Unit LBB 3535/00. Available in extended
stem microphone version (LBB 3537/50).
LBB 3537/00 shown
Features
•
•
•
•
Uni-directional microphone on adjustable stem
Built-in plop- and windscreen
On/off switch and LED status indicators
Extended microphone stem length (LBB 3537/50 model)
Specifications
Microphone with light-ring, built-in plop and windscreen, mounted on a
flexible stem, microphone on/off button, microphone on/request-to-speak
bi-color LED indicator (red-microphone on, green-request to speak).
Microphone controls &
indicators
Interconnection
Mounting type
6 ft. (2 m) cable terminated with 8-pole, 262° DIN-type plug.
Click-to-fit in a 0.08 . (2 mm), thick metal panel (secured using 2 screws).
Front panel 1.57 x 4.72 in. (40 x 120 mm), built-in depth 1.18 in. (30 mm).
3537/00 Microphone stem length 12.20 in. (310 mm).
3537/50 Microphone stem length 18.9 in. (480 mm).
Dimensions (H x W)
Weight
Color
.44 lbs. (200 g)
charcoal
page 1
Listen Technologies Corporation
8535 South 700 West, Suite A
Sandy, UT 84070-2515 U.S.A.
Phone: 1.801.233.8992 or 1.800.330.0891
Fax: 1.801.233.8995
Don't miss a single sound.
Email: [email protected]
updated 01.10.05
Listen® and the Listen logo are registered trademarks of Listen Technologies Corporation
DCN Flush Mount Control Panels
Chairman Priority Control Panel
Specify Part
Number
The chairman priority panel incorporates a priority but-
ton and an LED indicator. This unit is used in combina-
tion with the LBB 3537/00 Microphone with Control
Panel to create a chairman position. When the priority
button is pressed, all currently active delegate micro-
phones are temporarily switched off, (dependent on
CCU setting) thus giving the chairman priority micro-
phone status over other delegates. The chairman prior-
ity panel can be connected to Multi-Purpose
LBB 3537/10
Connection Unit LBB 3540/15, or to one input of the
Dual Audio Interface Unit LBB 3535/00.
Specifications
Microphone controls & indicators
‘Microphone on’ indicator (red LED), priority key.
Interconnection
6 ft. (2 m) cable terminated with 8-pole, 262° DIN-type plug.
Click-to-fit in a 0.08 in. (2 mm), thick metal panel (secured using 2
screws).
Mounting type
front panel 1.57 x 4.72 in. (40 x 120 mm), built-in depth 1.18 in.
(30 mm).
Dimensions (H x W)
Weight
Color
0.28 lbs (125 g)
charcoal
Table-Top Housing for Loudspeaker LBB 3538/00 and Two
Flush Mounted Units
Specify Part
Number
This housing enables the loudspeaker LBB 3538/00 to be used in table-
top applications. The loudspeaker simply clicks into place in the
housing, which is designed so the loudspeaker is facing the
delegate, thus increasing intelligibility. It can also be used to
mount two flush-mounted units e.g. the LBB 3537/00 microphone
and LBB 3524/00 channel selector. For permanent applications,
the housing can be fixed to the table-top by means of two
screws.
LBB 3527/00
Specifications
Dimensions (H x W x D) 4.72 x 2.87 x 3.14 in. (120 x 73 x 80 mm).
Weight
Color
0.37 lb. (170 g).
charcoal
page 3
Listen Technologies Corporation
8535 South 700 West, Suite A
Sandy, UT 84070-2515 U.S.A.
Phone: 1.801.233.8992 or 1.800.330.0891
Fax: 1.801.233.8995
Email: [email protected]
Don't miss a single sound.
updated 01.10.05
DCN Flush Mount Control Panels
Loudspeaker Panel
Ideal for flush mounting on table-tops or the rear of seats, this
Specify Part
Number
loudspeaker panel is intended for use in combination with the
Dual Audio Interface Unit (LBB 3535/00), or the Multi-Purpose
Connection Unit (LBB 3540/15). It consists of a
loudspeaker behind a rectangular grille. Also included
is a 6 ft. (2 m) cable, terminated with a 3.5 mm (0.14
in) stereo jack plug.
LBB 3538/00
Specifications
Click-to-fit in a 0.08 in. (2 mm), thick
metal panel (secured using 2 screws).
Mounting type
Dimensions
(H x W)
Front panel 3.15 x 4.72 in. (80 x 120
mm), built-in depth 1.18 in. (30 mm).
Weight
Color
0.44 lbs (200 g)
charcoal
Note: The LBB 3538/00 can be mounted in Table-Top Housing LBB 3527/00.
Delegate Voting Control Panel
Specify Part
Number
A flush mounting panel with voting facilities, the panel is intended for
flush mounting into table-tops or the arm rests of chairs etc. The panel
can be connected to the Multi-Purpose Connection Unit LBB 3540/15.
LBB 3541/00
Features
•
•
•
Allows three types of voting
LED vote confirmation indicators
Easily mountable
Specifications
Mounting
Click-to-fit in a metal panel with a thickness of 0.08 in. (2 mm) (4 screws optional).
Dimensions (H x W) Front panel 1.57 x 4.72 in. (40 x 120 mm), built-in depth 1.18 in (30 mm).
Weight
Color
0.25 lb (115 g)
charcoal
page 4
Don't miss a single sound.
updated 01.10.05
DCN Flush Mount Control Panels
Delegate/Chairman Voting Control Panel
Specify Part
Number
This flush-mounting panel with voting and other control facilities includes a 2-
line, 40-character LCD screen, and has mounting facilities for a Chip Card
Reader LBB 3543/15. The panel is intended for flush mounting into table-tops
and can be connected to Multi-Purpose
LBB 3542/00
Connection Unit LBB 3540/15.
The LCD screen enables delegates to view
valuable conference-related information, general
user instructions and text messages.
Features
•
•
•
•
2-line, 40-character LCD screen
Displays extra information including messages
Full range of voting control options
LED vote confirmation indicators
Specifications
Mounting
Click-to-fit in a metal panel with a thickness of 0.08 in. (2 mm) (4 screws optional).
Dimensions (H x W) Front panel 3.41 x 9.44 in. (80 x 240 mm), built-in depth 1.18 in. (30 mm).
Weight
Color
0.57 lb (260 g)
charcoal
Chip Card Reader Panel
Specify Part
The flush-mounted chip card reader enables electronic identification of
delegates to the DCN system as well as providing a convenient facility
that ensures only authorized delegates can participate in voting
sessions or general conference proceedings such as microphone use.
The Chip Card Reader can be connected to
the Multi-Purpose Connection Unit LBB
Number
LBB 3543/15
3540/15.
Features
•
•
Card reader slot for delegate identification
“Card accepted” LED indicator
Specifications
Mounting
Click-to-fit in a metal panel with a thickness of 0.08 in. (2 mm) (4 screws optional).
Dimensions (H x W) Front panel 1.57 x 4.72 in (40 x 120 mm), built-in depth 1.18 in. (30 mm).
Weight
Color
0.36 lb. (165 g)
charcoal
page 5
Listen Technologies Corporation
8535 South 700 West, Suite A
Sandy, UT 84070-2515 U.S.A.
Phone: 1.801.233.8992 or 1.800.330.0891
Fax: 1.801.233.8995
Email: [email protected]
Don't miss a single sound.
updated 01.10.05
DCN Flush Mount Control Panels
Blanking Panel
Specify Part
The LBB 3539/00 Blanking Panel can be used to neatly close off a slot in
Number
a flush-mounted unit that is not in use. The panel can be removed if
future expansion of the system requires that the slot be used.
LBB 3539/00
Specifications
Click-to-fit in a metal panel with a thickness of
0.08 in. (2 mm) (4 screws optional).
Mounting
Front panel 1.57 x 4.72 in. (40 x 120 mm), built-
in depth 1.18 in. (30 mm).
Dimensions (H x W)
Weight
Color
0.06 lb (30 g)
charcoal
Multi-Purpose Connection Unit
The Multi-Purpose Connection Unit is intended for use in flush-
mounted tailored solutions. Its versatility
enables a number of functions to be
added, making it ideal for both chair-
men and delegates alike.
Specify Part
Number
LBB 3540/15
Specifications
Mounting type
Dimensions (H x W)
Weight
Table-top (free standing), on wall or flush mounting.
1.37 x 3.93 x 6.69 in. (35 x 100 x 170 mm), (excl. cables).
1.1 lbs. (500 g)
Color
charcoal
Dual Audio Interface Unit
Specify Part
Number
The LBB 3535/00 Dual Audio Interface Unit enables various types of
microphones, as well as line sources, to be connected to the DCN
system. It can also be used to create a chairman position or for an
ambient microphone input.
LBB 3535/00
Features
•
•
•
•
Two separate inputs serving two delegate positions
Accepts both microphone and line inputs
Outputs to headphones or loudspeakers
Range of mounting options
Specifications
Mounting type
on wall, under table-top or seat, in arm rest or in cable duct
1.37 x 3.93 x 6.69 in (35 x 100 x 170 mm), (excl. cables)
Dimensions (H x W x D)
Weight
Color
1.1 lbs (500 g)
charcoal
page 6
Don't miss a single sound.
updated 01.10.05
|