1000 kW Containerized
Diesel Generator Set
Model
Emissions
Standby Rating
Prime Rating
60 Hertz
EGC1000C
EPA Certified
1000kW (1250kVA)
900kW (1125kVA)
1000 KW
(Shown with 40 ft. container and optional ISO trailer chassis)
Standard Features
Cummins Heavy Duty Diesel Engine
Full Load Acceptance
4-cycle design, turbocharged, aftercooled, direct injection
Polymide blade cooling fan
Accepts 100% of standby nameplate rating in one step, in compliance
with NFPA110 Standards
Engine coolant heater
Generator Control Panel
Meets Tier 2 EPA emissions standards
BASLER vibration-isolated controller
Manual or remote engine start/stop
Fuel System
RS485/Modbus communication support
Safety shutdowns
1000 gallon, single wall fuel tank
Fuel priming system
Fuel/water separators and drip pan
Electric fuel pump
Externally mounted emergency stop switch
Generator mainline circuit breaker, electronically operated, UL listed
External fuel fill
Specially Designed Container
®
30 micron RACOR fuel/water separator with drip pan assembly
■
40 ft. ISO container, sound-attenuated, foam-lined for extremely
quiet operation
Alternator
■
Isolated operator control room
Brushless, 4-pole, synchronous, WYE connection
Solidly mounted battery rack and cooling system
Intregral vibration isolators
Class H insulation system conforms to NEMA MG1-22, BS5000,
CSA-C22-2, IEC-34-1 standards for temperature rise
Exterior polyurethane coating system provides long life in extreme
operating conditions
Separate excitation for fast recovery from block loads and motor
starting
Interior DC lights and timer switch
Crankcase filtration system
Drip-proof, self-venting, amortisseur windings
Epoxy impregnated windings with tropical insulation for increased
environmental protection and long life
Critical grade silencer with heat blankets
Automatic Voltage Regulator
Warranty
Engine-generator sets are covered by an express written, one-year
limited warranty
■
Circuitry senses true RMS voltage, rather than average, for superior
load regulation
EGC1000C Rev 3
1000 kW Containerized
Diesel Generator Set
Cooling System
Exhaust Manifold Type
Radiator Design
Dry
Standard Horizontal
37 gal. (140 L)
Coolant Capacity - Engine Only
Water Pump Design/Type
Coolant Flow
Belt Driven, Centrifugal
100 gal/min (378 L/min)
40600 Btu/min (715 kW)
180-200°F (82-93°C)
Heat Rejection to Coolant (Standby)
Thermostat Range
DGC2020 Digital Genset Controller
Fuel System
Recommended Fuel
Filter Micron Size
Total Fuel Flow
Digital Controller Features
ASTM-D975/No.1 & No.2-D
■
■
■
■
■
■
■
■
■
■
■
Local and Remote Generator Control
Automatic and manual starting and stopping
Engine and Generator Protection
Programmable Analog Engine Senders
ECU Communications via SAE J1939
16 Programmable Contact Inputs
Programmable Logic
2
150 gal./hr. (568 L/Hr.)
Fuel Consumption
gal/hr
Diesel at % of Load
L/hr
7.3
25%
50%
75%
100%
19.3
36.0
52.6
69.3
136
199
262
Automatic Transfer Switch Control (Mains Failure)
Integrated RS485 Modbus Connection
Auto Synchronizing
Lubrication System
Type
Full Pressure
Event recording
Oil Filters
4 Spin-on Full Flow
45-56 psi (310-386 kPa)
35 gal (132 L)
Monitoring
Oil Pressure at Rated Speed
Oil Capacity with Filters
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
Engine RPM
Engine run time
Generator voltage
Generator current
Generator frequency
Derating (60Hz)
Ambient
Temperature
Oil pressure
Altitude
The engine power available up to 4958 ft.
at temperatures up to 104oF and up to
4433 ft. at 122°F at standby rating, without
derating. For operation at higher altitudes
and ambient temperatures, the power
should be derated according to the
following factors:
Battery voltage
Above 4958 ft.
derate at 3.4%
per 1000 ft. up to
9843 ft. Derate
an additional 9%
per 1000 ft.
Fuel level measurements
Running Hour Meter
Above 122°F,
derate an
additional
15% per 18°F
Coolant temperature
above 9843 ft.
Generator under/over voltage alarm/shutdown
Generator under/over frequency alarm/shutdown
Over Current alarm/shutdown
Warm up and cooling functions
Maintenance timer
EGC1000C Rev 3
1000 kW Containerized
Diesel Generator Set
Optional Features and Accessories
Container
Generator Set
ISO Trailer Chassis (40 ft.)
Genset-to-Genset Paralleling Control System
Double-wall Fuel Tank (900-gallon capacity)
Fluid Containment
Base Load-to-Utility Paralleling Control System
Custom Outlet Panels
Manual Fuel Valves (For Internal or External Fuel
Supply)
Rotary Voltage Selector Switch (High Wye/Low Wye
Voltages)
Entrance Ladder (6-Step, Aluminum Construction)
Auxiliary Oil Reservoir with Level Control (15-gallon)
Centrifugal Oil Filter System
Fueling Ladder (Aluminum Step Construction with
Hand Rail)
Oil Pan Heater with Thermostat
Interior Lights (AC Work lights)
Alternator Strip Heater
Custom Paint Colors (Artic White is Standard)
AC Battery Charger with Shore Power Receptacle
120VAC Convenience Receptacle
Utility Grade Protective Relay
SPECIAL OPTIONS AVAILABLE UPON REQUEST
40 ft. Container
Weight and Dimensions
A
B
C
D
96 in.
(2,438 mm) (12,192 mm) (4,137 mm)
480 in.
163 in.
199 in
(5,054 mm)
Weight (Dry)*
38,460 lbs (17,445 kg)
45,200 lbs (20,500 kg)
Weight (Wet with trailer)*
* Weight is approximate. Wet weight does not include fuel.
Backfeed to a utility system can cause electrocution and/or property
damage. Do not connect to any building’s electrical system except
through an approved device. Features and specifications are subject to
change without notice.
Your MQ Power dealer is:
MQ POWER
POST OFFICE BOX 6254
CARSON, CA 90749
310-537-3700
•
800-421-1244
FAX: 310-632-2656
E-MAIL: [email protected]
© COPYRIGHT 2011, MQ POWER
Rev 3 (11/29/11) EGC1000C
|