NETGEAR Network Hardware XAVB1601 100NAS User Manual

Powerline 200 Nano PassThru (2-pack)  
XAVB1601 Installation Guide  
 
Package Contents  
Powerline  
XAV1601  
adapters  
Ethernet  
cables (2)  
Resource  
CD  
Your adapters might look like one of these:  
2
 
 
Hardware Features  
Power LED  
Ethernet LED  
Powerline LED  
Security  
button  
Ethernet port  
Factory Reset  
button  
NETGEAR recommends  
that you do not plug a  
Powerline adapter  
directly into a power strip.  
3
 
 
LED Descriptions  
Item  
Description  
Power  
LED  
Solid green. The electrical power is on.  
Blinking green. The adapter is in the process of restarting  
or setting up security.  
Solid Amber. The adapter is in power saving mode.  
Off. There is no electrical power.  
Powerline Solid green. The adapter is connected to a Powerline  
LED  
network.  
Off. The adapter has not found any other compatible  
Powerline devices using the same encryption key.  
The Pick A Plug feature lets you choose the electrical outlet  
with the strongest link rate, which is indicated by the LED color:  
Green:  
Link rate > 80 Mbps Link rate > 50 and < Link rate < 50 Mbps  
(Best) 80 Mbps (Better) (Good)  
Amber:  
Red:  
Ethernet  
LED  
Solid green. The Ethernet port is linked or data is being  
transmitted.  
Off. There is no Ethernet connection  
4
 
 
Button Descriptions  
Item  
Description  
Factory  
Reset  
Press the Factory Reset button for 1 second, and release it to  
return the Powerline adapter to its factory default settings.  
button  
Security  
button  
• After you plug in your new AV adapter, press the Security  
button for 2 seconds, and then press the Security button on  
one of the other AV adapters in your existing network for 2  
seconds. Both buttons must be pressed within 2 minutes.  
• Press the Security button for 10 seconds to put the adapter  
into power saving mode. Press the Security button again  
for 0.5 seconds to wake it.  
Filtered  
The filtered AC socket can remove some electrical noise that  
AC Socket might affect Powerline performance. Plugging the power plugs  
of nearby devices into the filtered AC socket might improve  
performance.  
Warning: Do not press the Security/Power button on the Powerline adapter  
until installation is complete, and the adapters are communicating with each  
other (indicated by the blinking Powerline LED). Pressing this button too soon  
can temporarily disable Powerline communication. If Powerline  
communication becomes disabled, press the Factory Reset button to return  
the Powerline adapter to its factory default settings.  
5
 
 
Room 1  
Room 2  
6
 
Compatible NETGEAR Powerline Devices  
Compatible Powerline and HomePlug AV certified devices  
include the NETGEAR XAV101, XAV1004, XAV2001, XAV2501,  
XAVN2001, XAV2101, XAV5001, XAV5501, and XAV5004.  
For a complete list of HomePlug AV certified devices, go to  
7
 
 
Safety Information:  
AC input:100–125V, 0.1A (Max: NA) and 200–250V, 0.1A (Max;  
others), for product only.  
Operating temperature: 0–40°C  
The socket-outlet shall be installed near the equipment and shall be  
easily accessible.  
XAV1601 ratings (maximum load):  
EU: 16A 250V  
UK: 13A 250V  
NA: 12A 125V  
Only power cords are allowed to be inserted into the filtered AC  
outlet; no other equipment with a direct plug-in is allowed. The  
power cord needs to be a maximum of 1m long and a minimum of  
0.75 mm square of cross-sectional area.  
Do not plug devices into the XAV1601 filtered AC outlet that exceed  
the product ratings.The output voltage of the filtered AC outlet is the  
same as the power outlet into which the XAV1601 is plugged. To  
help avoid damaging your system, be sure that the attached devices  
are electrically rated to operate with the power available in your  
location.  
If the input AC voltage is less than 125 Vac, the device plugged into  
the filtered AC socket of the XAV1601 might not perform as well as  
expected.  
DO NOT PLUG MAJOR HOME APPLIANCES into the filtered AC  
socket or into an attached powerstrip. The device is not intended to  
be used with home appliances such as air conditioners, power tools,  
space heaters, fans, hair dryers, ovens, or refrigerators.  
Check the electrical current for any appliance used with the device,  
and do not exceed home and product outlet ratings and electrical  
requirements.  
 
User Manual  
You can get the user manual online at  
Compliance  
For the complete EU Declaration of Conformity, visit:  
This symbol appears in accordance with the European Union  
Directive 2002/96 on the Waste Electrical and Electronic  
Equipment (the WEEE directive). If you dispose of this  
product in the European Union, treat and recycle it in  
accordance with your jurisdiction’s laws that implement the  
WEEE directive.  
For indoor use only in all EU countries and in Switzerland.  
 
NETGEAR, Inc.  
350 East Plumeria Drive  
San Jose, CA 95134, USA  
August 2012  
 

Miele Clothes Dryer T442C User Manual
Miele Freezer F 12020 S User Manual
Multiquip Portable Generator MQP20IZ User Manual
NetComm Network Router NP290W User Manual
North Star Portable Generator 165959 User Manual
Oki Computer Hardware 70049601 User Manual
Omron Blood Pressure Monitor i Q142 User Manual
OPPO Digital Blu ray Player BDP 103 User Manual
Orbit Manufacturing Outdoor Timer 57912 User Manual
Orion Car Audio Car Speaker HCCA52 User Manual