Nortel Networks Network Router 911x Series User Manual

Standard 1.1  
Part No. N0027496  
January 2005  
Remote Gateway 911x Series  
Quick Start Guide  
 
Standard 1.1  
3
Preface  
Congratulations on your purchase of the Remote Gateway 911x series unit. With  
the Remote Gateway 911x product you have the advantage of a full featured host  
PBX at your home office.  
This Quick Start Guide gets you up and running with your Remote Gateway unit.  
It contains:  
installation instructions for the Remote Gateway 9110 circuit card  
installation instructions for the Remote Gateway 9115 unit  
telephone configuration procedure for the Remote Gateway 9110 and 9115  
units  
For more detailed instructions and troubleshooting solutions, refer to the Remote  
Gateway 911x Series Installation and Administration Guide (555-8421-220). To  
locate this documents, click on the Technical Documentation link at the  
following website:  
Remote Gateway 911x Series Quick Start Guide  
 
Standard 1.1  
4 Preface  
P0918963  
 
Standard 1.1  
5
You need a 10BaseT Ethernet cable to provide the Remote Gateway 911x series  
unit with voice over IP capability. For instructions on how to install a Remote  
Gateway 911x unit turn to Installing the Remote Gateway 911x unit” on page  
7.  
Installing the Remote Gateway 9110 circuit card  
You need the following tools to install the Remote Gateway 9110 circuit card in  
your Meridian (M2000 series) digital telephone:  
antistatic ESD wrist strap (recommended)  
Phillips screwdriver  
To insert the Remote Gateway 9110 circuit card:  
1
2
Disconnect the telephone-side connection of the RJ11 TCM telephone cable,  
(the other end connects to the wall jack).  
Place the telephone on a flat surface with the keypad facing down and remove  
Note: Ensure that you are properly grounded with an approved ESD strap.  
3
4
Pop out the front panel inserts in the footstand of the telephone to make the  
connections accessible when you install the circuit card. Refer to  
Connecting the Remote Gateway 911x series unit to the network” on  
page 7.  
Remove the circuit card from its antistatic bag and insert the leading edge of  
the circuit card under the two brackets in the footstand. Use both hands to  
push forward until the card snaps into place under the brackets.  
Note: Two holes on either side of the circuit card align with  
corresponding holes in the footstand.  
Remote Gateway 911x Series Quick Start Guide  
 
Standard 1.1  
6
Installation  
5
6
Secure the circuit card to the footstand with the two screws provided.  
Plug the 18 cm (7 inch), TCM cable into the RJ11 jack on the telephone (the  
other end is attached to the Remote Gateway 9110 circuit card).  
7
8
Re-attach the footstand to the bottom of the telephone (2 screws).  
Apply the label overlay identifying the power connection, analog line and  
RJ-45 Ethernet jack.  
Installing ferrite beads  
The Remote Gateway 9110 circuit card installation kit contains two ferrite beads.  
Ferrite beads protect the Ethernet and power supply cable from electro-magnetic  
interference (EMI). The two heavy pieces of ferrite come in a plastic-hinged cover  
that forms a block and has a hole in the middle for the cable to pass through. You  
must install the ferrite bead close to the plug that connects to the Remote Gateway  
9110 circuit card.  
To install the ferrite beads for both the Ethernet cable and the power supply cable:  
1
2
Open the plastic latch at the side of the ferrite bead.  
Lay a cable across the middle of the ferrite bead.  
The ferrite bead must be close to the cable connector.  
3
Loop the cable tightly around the ferrite bead.  
There must 2 loops of Ethernet cable around the ferrite bead (the Ethernet  
cable lays across the ferrite bead 3 times).  
There must be 3 loops of power supply cable around the ferrite bead (the  
power supply cable lays across the ferrite bead 4 times).  
P0918963  
 
Standard 1.1  
Installation 7  
4
Close and latch the ferrite bead.  
Note: You may need to adjust the cable loops to make them as tight as  
possible.  
Installing the Remote Gateway 911x unit  
To install the Remote Gateway 911x unit on a desk, attach the rubber feet to the  
bottom and continue with Connecting the Remote Gateway 911x series unit  
to the network” on page 7. To install the Remote Gateway 911x unit on the wall,  
refer to the Remote Gateway 911x Series Installation and Administration Guide  
(555-8421-220).  
Connecting the Remote Gateway 911x series unit to the  
network  
To route calls over the IP network, or administer the Remote Gateway 911x series  
unit from another location on the IP network, connect the unit to the Ethernet  
network by doing the following:  
1
2
Plug one end of a 10BaseT Ethernet cable (with an RJ-45 connector) to the  
ETHERNET jack on the Remote Gateway 911x series unit.  
Note: You must supply your own 10BaseT Ethernet cable with RJ-45  
connectors. Contact your system administrator for the correct cable.  
Plug the other end of the 10BaseT Ethernet cable to either an Ethernet hub or  
network router.  
To connect the Remote Gateway 911x series unit to the analog line:  
1
2
Plug the RJ-11 cable into the 911x unit LINE connector.  
Plug the other end of the cable into the analog line jack.  
Remote Gateway 911x Series Quick Start Guide  
 
   
Standard 1.1  
Installation  
8
To connect the Remote Gateway 911x series unit to the power source as follows:  
1
Connect the plug on the power transformer to the POWER connector on the  
Remote Gateway 911x series unit.  
2
3
Attach the power cord to the power transformer.  
Plug the power supply into an uninterruptible power source (UPS) or wall  
outlet.  
As soon as you connect the Remote Gateway 911x unit to the power source, the  
unit begins to power up and the power LED comes on. The power-up cycle takes  
about 30 seconds to complete. When the Remote Gateway 911x unit completes a  
successful self-test, the power LED flashes three times and the telephone display  
shows one of the following two messages:  
a time and date, if connected to a PBX  
HOSTLESS MODE, if the 911x unit is not configured  
The ETHERNET TX and RX LEDs flash only during transmit and receive  
activity.  
P0918963  
 
Standard 1.1  
9
Configuration  
You can configure the Remote Gateway 911x series unit through the telephone  
set. The procedure is the same for either the Remote Gateway 9110 circuit card or  
9115 unit. Before you begin, your System Administrator must supply you with a  
completed Remote Gateway 911x series telephone menu — Configuration Values  
form. Use the information provided on this form to configure the Remote  
Gateway 911x series unit.  
Note: The procedure to configure the Remote Gateway 911x series unit  
establishes a connection between the unit and the RLC. The System Administrator  
can then configure the other parameters through the network connection.  
If your System Administrator has already configured your unit, you do not need to  
complete the configuration procedure.  
Telephone menu keys  
When working with the Remote Gateway 9100 Series telephone menu, use the  
following table as a guide for the proper keys to use:  
Key name  
Key label  
911x telephone menu key function  
DIGIT  
ALPHA  
YES  
1, 2, 3, 4, 5, 6, 7, 8, 9, 0 user name/password entry, numeric entry  
2, 3, 4, 5, 6, 7, 8, 9  
user name/password entry  
request menu, enable feature  
skip menu, disable feature  
1
2
NO  
RELEASE  
Rls, R, Goodbye  
(depending on your  
telephone set)  
enter configuration mode, return to  
previous menu, exit system  
ENTER  
Hold  
accept selection, move to next menu  
prompt  
Remote Gateway 911x Series Quick Start Guide  
 
 
Standard 1.1  
10 Configuration  
Key name  
Key label  
911x telephone menu key function  
ASTERISK  
POUND  
*
period (.), delimiter for IP addresses  
backspace with delete  
#
Note: If, at any time while working with the telephone set menu, you make a  
mistake, you can return to the previous level in the menu system by pressing the  
Release (Rls, R, or Goodbye depending on your telephone set) key once.  
Configuring the Remote Gateway 911x series unit  
After installing the Remote Gateway 911x series unit and powering up:  
1
Press the Release key four times within three seconds to access the telephone  
menu.  
Result: The telephone display prompts you for a user name:  
Enter User Name  
Press the Rls key to exit.  
2
3
Enter 48378 (GUEST) on the telephone keypad and then press Hold.  
Result: The telephone display prompts you for a password:  
Enter Password  
Press the Rls key to exit.  
Enter 48378123 (GUEST123), the default password, or the current password  
if you have customized the password and then press Hold.  
Result: The telephone display prompts you to display the Remote Gateway  
911x series unit’s IP parameters:  
[1-Yes 2-No]  
4
Use the information provided on the Remote Gateway 911x series telephone  
menu — Configuration Values form to respond to each telephone display  
prompt and make the appropriate menu selection. Refer to Telephone menu  
keys” on page 9 for further assistance.  
Contact your System Administrator if you experience any problems configuring  
the Remote Gateway 911x series unit.  
P0918963  
 

Miele Washer G 7823 User Manual
Milwaukee Handheld TV SM806 User Manual
Navman Marine GPS System MULTI 3100 User Manual
Newcon Optik Binoculars BDN 14X50 User Manual
Nikon Digital Camera 13303 User Manual
NuTone Blower 2730 User Manual
Omnimount TV Mount 2N1 M User Manual
Onkyo Speaker System HTP 750 User Manual
Onkyo Stereo System DR C500 User Manual
Panasonic IP Phone KX NT265 User Manual