DSD31 / DSD33
Features
* DSD31 / DSD33
* True galvanic isolation design ensures that such serious AC mains problems as noise, lightning
effects, leakage current do not reach your systems.
* Protection from the accidental disconnection of the neutral wire ensures the safety of the UPS
and the stability of the power supply.
* Protection from incorrect operation ensures that violating the operation procedures will not
lead to UPS or connected equipment damage.
* The use of up-to-date DSP, IGBT and switching components ensures the high reliability and
efficiency of the UPS.
* Multi-CPU design increases the system reliability.
* Plug-and-play design and easy access to boards ensures the fastest and easiest UPS
maintenance.
* Individual inverter for each phase ensures stable work under completely unbalanced load.
* Intelligent charger with temperature compensation feature ensures the longest possible battery
life. The adjustable level of charging current allows the UPS to work with large battery banks for
long backup time.
* Intelligent battery test logics eliminate the possibility of power supply interruption during battery
test in case of batteries being bad. Provides the detection of battery electrolyte leakage and
improper battery grounding.
* Intelligent fan speed control increases the fan life expectancy and reduces the audible noise.
* Advanced heat abstraction design by physical separation of the power and control circuitry
ensures the smooth operation of the UPS under most harsh conditions.
* Cold start function makes it possible to start the UPS even when AC mains are not providing the
power.
* 12-pulse rectifier ensures reduced harmonics for UPS with capacities of 80KVA and higher.
* Input harmonic filter reduces the Total Harmonic Distortion (T.H.D.) of the UPS.
* Parallel operation makes it possible to upgrade the UPS to a larger capacity.
38.
Specifications
PHASE
Capacity(KVA)
3-Phase Input/1-Phase Output
30 40 50 60
10
15
20
80
100
120
INPUT(RECITIFIER)
Input Voltage
380/400/415VAC
Input Range
+/- 20% (> +/- 20% is available upon request)
Input Frequency
Power Walk In
Efficiency
50 / 60Hz +/- 5Hz
0%~100% : 20sec
98%
INVERTER
Output Voltage
220/230/240VAC SINGLE PHASE
Wave Form
Sinewave
0.8
+/- 1%
Output Power Factor
Voltage Regulation
Frequency Lock Range
Output Frequency (Free Running)
Phase Shift Under 100% Unbalance Load
T.H.D.(Linear Load)
50 / 60Hz +/- 3Hz
50 / 60Hz +/- 0.1Hz
< 0.5
< 2%
Overload
< 110%
Continuous
15 minutes
10 minutes
1 minute
110~125%
125~150%
> 150%
Efficiency(100% Load)
STATIC SWITCH
92%
92%
93%
93%
93.5%
93.5%
94%
94.5%
94.5%
95%
Voltage Range
173~277VAC (LINE TO NEUTRAL)
Frequency Range
Efficiency
Mains to Inverter
45~55 Hz / 55~65 Hz
99.5%
0 ms
Overload 100%
Overload 300%
Isolation Transformer
OVERALL CHARACTERISTICS
Maximum Heat Dissipation (kW)
30 sec
1 sec
YES
1.3
1.3
1.3
1.9
550
2.6
3
3.5
4.6
5.4
6.5
1600
Dimantion
Heigh(mm)
Width(mm)
Depth(mm)
1100
800
0~40 (32~96
0%~90%(Non-Condensing)
< 1500M Above Sea Level
Environment Temperature
Humidity
)
Altitude
Weight(kg)
200
250
300
400
480
550
750
900
1000
1250
Auduble Noise
< 60 dBA (At 1 m)
Certificate
CE
YES
YES
YES
EN50091-1,2
FCC CLASSA
Short Circuit Protection
Lightning Protection
EMC Filter
YES
MOV
Input & Output
Galvanic Isolation
LED,LCD,Buzzer
Start On Battery
Input & Output True Galvanic Isolation
YES
YES
*Specifications are subject to change without notice
Sine Wave
40.
Battery Cabinet Specifications
Battery Cabinet Design
The battery cabinet is designed with the same size and outlook as the UPS for
convenience of installation when several cabinets of UPS and battery
are aligned together. It can accommodate Lead Acid maintenance free battery
26Ah/12V * 29 pcs (1 set) or 58 pcs (2 sets).
Dimension (H xW x Dmm)
1600 x 550 x 800
Weight
26Ah/12V x 29 pcs x 1 set is about 360kgs
26Ah/12V x 29 pcs x 2 sets is about 620kgs
DSD 80K - 160K
DSD 10K - 60K
m
m
0
0
1
1
0
0
8
m
m
DSD 200K - 400K
m
m
0
0
8
mm
550
2
2
0
0
m
m
m
m
0
0
8
41.
|