Oceanic Thermostat Regulator Equipment User Manual

 
Owner's Guide  
CONTENTS  
WARNINGS ................................................................................................... 2  
NOTICES AND WARRANTY......................................................................... 2  
INTRODUCTION ........................................................................................... 4  
STATEMENT FOR COMPATIBILITY AND USE WITH NITROX .................. 4  
STATEMENT FOR COLD WATER DIVING.................................................. 5  
REGULATOR FIRST STAGES...................................................................... 6  
ATTACHMENT OF HOSES ......................................................................... 6  
REMOVAL OF HOSES ................................................................................ 7  
DATALINK™ ................................................................................................ 8  
REGULATOR ATTACHMENT TO A TANK................................................... 8  
ENVIRONMENTAL PROTECTION KIT ..................................................... 11  
REGULATOR SECOND STAGES .............................................................. 11  
FEATURES AND OPERATION ................................................................. 11  
®
ALPHA 7 , GAMMA™, PONY BOTTLE, AND EXPLORERS ................. 12  
®
DELTA 3 AND GAMMA 2..................................................................... 12  
OMEGA™ II AND OMEGA™ II WITH SWIVEL ........................................ 14  
SECOND STAGE SWIVEL ........................................................................ 15  
ZETA™ ...................................................................................................... 15  
SLIMLINE™ OCTOPUS ............................................................................ 15  
SWIVEL 180™ OCTOPUS ........................................................................ 15  
CARE AND MAINTENANCE ....................................................................... 16  
ADDITIONAL SPECIFICATIONS ................................................................ 17  
GUIDELINES FOR MINIMUM SERVICE INTERVALS ............................... 18  
RECORDS ................................................................................................... 19  
INSPECTIONS AND SERVICE ................................................................... 19  
 
3
Oceanic Regulator  
INTRODUCTION  
STATEMENT FOR  
OCEANIC REGULATOR EQUIPMENT  
COMPATIBILITY AND USE WITH NITROX  
WARNINGS:  
Oceanic Regulators are not intended to be used by untrained per-  
sons who may not know the inherent risks and hazards of SCUBA  
diving.  
Prior to use of Oceanic Regulator equipment with nitrogen-oxygen  
(Nitrox) breathing gas mixtures that contain a higher fraction of  
oxygen than 21%, the user must have received, or must first ob-  
tain, certification in diving with Nitrox from a recognized training  
agency.  
An Oceanic Regulator is not a medical device. It is not intended  
and must not be used to supply treatment oxygen in a medical  
emergency.  
 
4
Owner's Guide  
NOTE: The term breathing gas used throughout this owner's  
guide applies to enriched nitrogen-oxygen (Nitrox) mixtures as  
well as compressed Air.  
When using Air with this regulator equipment, the Air used must  
meet EN132 Annex A standards.  
STATEMENT FOR  
OCEANIC REGULATOR EQUIPMENT  
COLD WATER DIVING  
WARNING: Installation of an Environmental Protection Kit must  
be performed by the Oceanic factory or an Authorized Oceanic  
Dealer. Improper installation may cause First Stage failure while  
underwater resulting in serious injury or death.  
WARNING: Failure to obtain proper training in the specialized  
techniques required for diving in cold water environments and  
failure to apply such techniques to handle situations that could re-  
sult in Regulator freezing will place you in risk of serious injury or  
death.  
 
5
Oceanic Regulator  
REGULATOR FIRST STAGES  
WARNING: Failure to prepare your First Stage properly for use in  
harsh environmental conditions, such as being subjected to sedi-  
ment or the possible buildup of ice, or salt crystals, may result  
in serious injury or death.  
WARNING: Under no circumstances should adjustment of an  
Oceanic first stage regulator be performed by anyone other than  
an Authorized Oceanic Dealer. Doing so may cause failure under-  
water, resulting in serious injury or death.  
ATTACHMENT OF HOSES  
 
6
Owner's Guide  
REMOVAL OF HOSES  
WARNING: At least one second stage must be connected to the  
first stage to facilitate purging of breathing gas from the first  
stage.  
DATALINK™  
WARNING: Proper installation of the DataLink is essential for it to  
function properly. It must be installed only by an Authorized Oce-  
anic Dealer.  
 
7
Oceanic Regulator  
NOTE: Once the DataLink has been disconnected, the regulator  
system can again be pressurized.  
REGULATOR ATTACHMENT TO A TANK  
WARNING: Maximum working pressure for an Oceanic Yoke style  
connector is 3500 PSI / 232 BAR and for a DIN style connector is  
4500 PSI / 300 BAR  
 
8
Owner's Guide  
DIN WHEEL STYLE CONNECTOR  
 
9
Oceanic Regulator  
DIN TO USA CONVERTER YOKE  
WARNING: The DIN to USA Converter is specifically designed for  
use with Oceanic brand first stages. Although it may fit other  
brand first stages, it was not designed to do so or tested for use  
with other brands. Under no circumstances should the Oceanic  
DIN to USA Converter be used with any other first stage than an  
Oceanic model.  
 
10  
Owner's Guide  
ENVIRONMENTAL PROTECTION KIT  
WARNING: Installation of an Environmental Kit must be per-  
formed by an Authorized Oceanic Dealer. Improper installation  
may cause first stage failure while underwater resulting in serious  
injury or death.  
REGULATOR SECOND STAGES  
WARNING: Even if your First Stage is properly prepared for use  
in harsh environmental conditions, only proper training will pro-  
tect your Second Stage from the effects of the environment.  
FEATURES AND OPERATION  
 
11  
Oceanic Regulator  
Alpha 7, Gamma, Pony Bottle, and Explorers (Primary and Octopus)  
NOTE: If these second stages are shipped from the factory spe-  
cifically as an Octopus, the inhalation effort is set slightly higher  
to reduce sensitivity.  
Delta 3 and Gamma 2 (Primary and Octopus)  
Pre-Dive/Dive Switch (on top):  
 
12  
Owner's Guide  
Delta 3 Adjustment Knob (on side):  
Guidelines for Delta 3adjustments (knob on side):  
NOTE: Rotation of the Delta 3 adjustment knob does not rotate  
the poppet seat against the sealing orifice.  
 
13  
Oceanic Regulator  
 
14  
Owner's Guide  
NOTE: Due to the Zeta's servo design, a hiss may be heard upon  
being pressurized. This is normal for the Zeta.  
 
15  
Oceanic Regulator  
CARE AND MAINTENANCE  
TRANSPORT and STORAGE  
POST DIVE CARE  
REPAIRS and SERVICE  
WARNING: DO NOT attempt to disassemble or repair the first or  
second stages, or to adjust the first stage. Doing so could cause  
malfunction while underwater resulting in serious injury or death.  
It will also void the regulator's limited warranty.  
 
16  
Owner's Guide  
ADDITIONALSPECIFICATIONS  
FOR CONNECTING COMPONENTS TO  
OCEANIC REGULATOR FIRST STAGES  
Second Stage (Primary or Octopus):  
Pressure Gauge or Pressure Transmitter:  
 
17  
Oceanic Regulator  
GUIDELINE FOR  
OCEANIC REGULATOR EQUIPMENT  
MINIMUM SERVICE INTERVALS  
 
18  
Owner's Guide  
RECORDS  
First Stage Model  
First Stage Serial#  
Second Stage Model  
Second Stage Serial#  
Octopus Model  
________________________________  
________________________________  
________________________________  
________________________________  
________________________________  
________________________________  
________________________________  
________________________________  
________________________________  
Octopus Serial#  
Date of Purchase  
Oceanic Dealer  
Dealer Phone No.  
INSPECTIONS / SERVICE  
Date  
Service  
Authorized Dealer / Technician  
 
19  
OCEANIC WORLD WIDE  
OCEANIC USA  
2002 Davis Street  
San Leandro, CA 94577  
Tel: 510/562-0500  
Fax: 510/569-5404  
Oceanic Central/North Europe  
Wendelstein, Germany  
Tel: 09129-9099780 Fax: 09129-9099789  
Oceanic South Europe  
Genova, Italy  
Tel: 0039-010-8382006 Fax: 0039-010-8365360  
Oceanic SW, Ltd  
Devon, United Kingdom  
Tel: 44-1-404-89-1819 Fax: 44-1-404-89-1909  
Oceanic France  
Marseille, France  
Tel: 0033.491.25.37.78 Fax: 0033.491.72.34.48  
Oceanic Diving Australia Pty. Ltd  
Sorrento, Victoria, Australia  
Tel: 61-3-5984-4770 Fax: 61-3-5984-4307  
Oceanic Asia-Pacific Pte. Ltd  
Singapore  
Tel: 65-6391-1420 Fax: 65-6297-5424  
Oceanic Japan  
Yokohama, Japan  
Tel: 045-575-6671 Fax: 045-575-6673  
Oceanic International (Pacific)  
Kapolei, Hawaii  
Tel: 808-682-5488 Fax: 808-682-1068  
© 2002 Design, 1996  
Doc. No. 12-2018-r08 (6/22/06)  
 

Milan Technology Switch MIL SM801XX User Manual
Milwaukee Drill 490 16200 User Manual
NordicTrack Treadmill NTL118060 User Manual
Nortel Networks Switch CVX 600 User Manual
NuTone Door LA107WH User Manual
Olympus Carrying Case PT 016 User Manual
Omron Sewing Machine DDAA1000 SRM User Manual
Onkyo Turntable CP 1050 User Manual
P3 International Indoor Furnishings P7650 User Manual
Palsonic Air Conditioner A12RINVT User Manual