Omron Blood Pressure Monitor BP762 User Manual

INSTRUCTION MANUAL  
7 series Plus  
Blood Pressure Monitor  
with ComFitTM Cuff  
Model BP762  
 
Before Using the Monitor  
INTRODUCTION  
®
Thank you for purchasing the Omron 7 series Plus BP762 Automatic  
TM  
Blood Pressure Monitor with ComFit Cuff.  
Fill in for future reference.  
DATE PURCHASED: __________________  
SERIAL NUMBER: ____________________  
• Staple your purchase receipt here  
• Register your product on-line at  
Your new blood pressure monitor uses the oscillometric method of  
blood pressure measurement. This means the monitor detects your  
blood’s movement through your brachial artery and converts the  
movements into a digital reading. An oscillometric monitor does not  
need a stethoscope so the monitor is simple to use.  
The BP762 comes with the following components:  
TM  
• Monitor  
• Storage Case  
• ComFit Cuff • AC Adapter  
• Instruction Manual printed in English and Spanish  
• Quick Start Guide  
The 7 series Plus BP762 Automatic Blood Pressure Monitor is intended  
for home use.  
Please read this instruction manual thoroughly before using the unit.  
Please keep for future reference.  
For specific information about your own blood pressure,  
CONSULT YOUR DOCTOR.  
SAVE THESE INSTRUCTIONS  
3
 
SAFETY INFORMATION  
To assure the correct use of the product basic safety measures should  
always be followed including the warnings and cautions listed in this  
instruction manual.  
SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL  
Indicates a potentially hazardous situation  
which, if not avoided, could result in death or  
serious injury.  
WARNING  
CAUTION  
Indicates a potentially hazardous situation  
which, if not avoided, may result in minor or  
moderate injury to the user or patient or  
damage to the equipment or other property.  
OPERATING THE DEVICE  
Contact your physician for specific information about your blood  
pressure. Self-diagnosis and treatment using measured results may  
be dangerous. Follow the instructions of your physician or licensed  
healthcare provider.  
DO NOT adjust medication based on measurement results from this  
blood pressure monitor. Take medication as prescribed by your  
physician. Only a physician is qualified to diagnose and treat High  
Blood Pressure.  
The monitor is not intended to be a diagnostic device.  
If battery fluid should get in your eyes, immediately rinse with  
plenty of clean water. Contact a physician immediately.  
Read all of the information in the instruction manual and any other  
literature in the box before operating the unit.  
4
 
SAFETY INFORMATION  
OPERATING THE DEVICE (continued)  
This device is intended for use in measuring blood pressure and  
pulse rate in the adult population. Do not use this device on infants  
or persons who cannot express their intentions.  
Read the Special Conditions section (page 29) of the instruction  
manual if your systolic pressure is known to be more than 220  
mmHg. Inflating to a higher pressure than necessary may result in  
bruising where the cuff is applied.  
Operate the device only as intended. Do not use the device for any  
other purpose.  
Dispose of the device, components and optional accessories  
according to applicable local regulations. Unlawful disposal may  
cause environmental pollution.  
Do not use a cellular phone near the device. It may result in an  
operational failure.  
Use only Omron authorized parts and accessories. Parts and  
accessories not approved for use with the device may damage the  
unit.  
Use only 1.5V alkaline batteries with this device.  
Do not use other types of batteries. This may damage the unit.  
5
 
SAFETY INFORMATION  
RISK OF ELECTRICAL SHOCK  
Do not plug or unplug the power cord into the electrical outlet with  
wet hands.  
Do not overload power outlets. Plug the device into the appropriate  
voltage outlet.  
CARE AND MAINTENANCE  
Do not subject the monitor to strong shocks, such as dropping the  
unit on the floor.  
Do not submerge the device or any of the components in water.  
Store the device and the components in a clean, safe location.  
Changes or modification not approved by Omron Healthcare will  
void the user warranty. Do not disassemble or attempt to repair the  
unit or components.  
6
 
BEFORE TAKING A MEASUREMENT  
To ensure a reliable reading follow these recommendations:  
1. Avoid eating, drinking alcohol, smoking, exercising, and bathing for  
30 minutes prior to taking a measurement. Rest for at least 15  
minutes prior to taking the measurement.  
2. Stress raises blood pressure. Avoid taking measurements during  
stressful times.  
3. Measurements should be taken in a quiet place.  
4. Remove tight-fitting clothing from your arm.  
5. Sit on a chair with your feet flat on the floor. Rest your arm on  
a table so that the cuff is at the same level as your heart.  
6. Remain still and do not talk during the measurement.  
7. Wait 2-3 minutes between measurements. The wait time allows the  
arteries to return to the condition prior to taking the blood pressure  
measurement. You may need to increase the wait time depending on  
your individual physiological characteristics.  
8. Keep a record of your blood pressure and pulse readings for your  
physician. A single measurement may not provide an accurate  
indication of your true blood pressure. You need to take and record  
several readings over a period of time. Try to measure your blood  
pressure at about the same time each day for consistency.  
7
 
Operating Instructions  
KNOW YOUR UNIT  
Main Unit:  
Display  
SET Button  
USER ID Selection Switch  
Memory ( ) Button  
Start/Stop Button  
Up/Down  
(
) Buttons  
/
Battery Compartment  
Air Jack  
AC Adapter Jack  
8
 
KNOW YOUR UNIT  
Components:  
Housing  
Air Tube  
Cord  
AC Adapter  
Air Plug  
(Connects to Air Jack)  
Arm Cuff  
INSTRUCTION MANUAL  
7
series Plus  
Blood Pressure Monitor  
with ComFitTM Cuff  
Model BP762  
Instruction Manual  
Storage Case  
Quick Start Guide  
9
 
UNIT DISPLAY  
Irregular Heartbeat Symbol  
Date/Time Display  
Average Value Symbol  
Memory Symbol  
USER ID Symbol (A/B)  
Systolic Blood Pressure  
Diastolic Blood Pressure  
Movement Symbol  
Blood Pressure Level Indicator  
Deflation Symbol  
Cuff Wrap Guide  
Heartbeat Symbol  
Low Battery Indicator  
Pulse Display / Memory Number  
10  
 
DISPLAY SYMBOLS  
IRREGULAR HEARTBEAT SYMBOL (  
)
When the monitor detects an irregular rhythm two or more times during  
the measurement, the Irregular Heartbeat Symbol ( ) will appear on the  
display with the measurement values.  
An irregular heartbeat rhythm is defined as  
Normal Heartbeat  
a rhythm that varies by less than 25% from  
Pulse  
the average rhythm or 25% more than the  
Blood  
pressure  
average rhythm detected while the monitor  
is measuring the systolic and diastolic  
Irregular Heartbeat  
blood pressure.  
Short Long  
If the irregular heartbeat symbol (  
)
Pulse  
displays with your measurement results, we  
recommend you consult your physician.  
Follow the directions of your doctor.  
Blood  
pressure  
MOVEMENT SYMBOL (  
)
The Movement Symbol is displayed if you move your body during the  
measurement. Please remove the arm cuff, and wait 2-3 minutes. Take  
another measurement, remain still during inflation.  
11  
 
DISPLAY SYMBOLS  
Internationally recognized guidelines for upper limit of normal home  
blood pressure readings are as follows:  
Home Guideline for Upper Limit of Normal BP  
Systolic Blood Pressure  
135 mmHg  
Diastolic Blood Pressure  
85 mmHg  
This is a general guideline because blood pressure depends on  
age and morbidity. A lower home blood pressure goal may be  
recommended for certain patients, including diabetic patients,  
pregnant women, and patients with renal failure.  
CAUTION  
The monitor is not intended to be a diagnostic device.  
HEARTBEAT SYMBOL (  
)
The Heartbeat Symbol flashes on the display at every heartbeat during  
the measurement.  
AVERAGE VALUE SYMBOL (  
)
The Average Value Symbol is displayed when you press the memory  
button. The most recent average reading appears on the display screen.  
CUFF WRAP GUIDE SYMBOL (  
/
)
When the cuff is applied correctly, ( ) is displayed while taking a  
measurement or using the memory function. If the cuff is not applied  
correctly, (  
) is displayed.  
12  
 
USING THE AC ADAPTER  
IMPORTANT SAFETY INSTRUCTIONS  
SAVE THESE INSTRUCTIONS  
- DANGER -  
TO REDUCE THE RISK OF  
FIRE OR ELECTRIC SHOCK,  
CAREFULLY FOLLOW THESE INSTRUCTIONS.  
For connection to a power supply not in the U.S.A., use an  
attachment plug adapter of the proper configuration for the power  
outlet.  
The power unit (AC Adapter) is intended to be correctly oriented  
in a vertical or floor mount position.  
NOTES: • Use only the authorized Omron AC Adapter that came with  
this monitor.  
• We recommend you install the batteries even if the AC  
Adapter is used. If no batteries are installed, you may need to  
reset the date and time if the AC Adapter is disconnected.  
The measurement results will not be deleted.  
CAUTION  
Use only Omron authorized parts and accessories. Parts and  
accessories not approved for use with the device may damage the  
unit.  
13  
 
USING THE AC ADAPTER  
TO CONNECT THE AC ADAPTER  
Insert the AC Adapter Plug into  
the AC Adapter Jack on the back  
side of the monitor as illustrated.  
Housing  
Plug the AC Adapter into a 120V  
AC outlet (60 cycles).  
Cord  
TO DISCONNECT THE AC ADAPTER  
Hold the Housing to remove the AC Adapter from the electrical  
outlet.  
Remove the AC Adapter plug from the monitor.  
WARNING  
Do not plug or unplug the power cord into the electrical outlet with  
wet hands.  
CAUTION  
Do not overload power outlets. Plug the device into the appropriate  
voltage outlet.  
14  
 
BATTERY INSTALLATION  
Battery Cover  
1. Remove the battery cover by pulling the  
hook up while pushing it in the direction  
of the arrow.  
2. Install 4 “AA” size batteries so the +  
(positive) and - (negative) polarities match  
the polarities of the battery compartment  
as indicated.  
3. Replace the battery cover.  
15  
 
BATTERY INSTALLATION  
BATTERY REPLACEMENT  
Low Battery Indicator  
When the Low Battery Indicator appears on the display screen turn the  
monitor off and remove all the batteries. Replace with four new batteries  
at the same time. Longlife alkaline batteries are recommended.  
CAUTION  
If battery fluid should get in your eyes, immediately rinse with  
plenty of clean water. Contact a physician immediately.  
NOTES: • Turn the unit off before replacing the batteries. If the  
batteries are removed while the unit is still on, the date and  
time will be reset to that of the previous use. However, the  
measurement results are not deleted.  
• When the batteries are replaced, you may need to reset the  
date and time. If “-:--” appears on the display, refer to  
“Setting the Date and Time”.  
CAUTION  
Dispose of the device, components and optional accessories  
according to applicable local regulations. Unlawful disposal may  
cause environmental pollution.  
16  
 
SETTING THE DATE AND TIME  
Set the monitor to the current date and time before taking a  
measurement for the first time. If the date and time are not set correctly,  
the measurement values stored in the memory and the average values  
may not be correct.  
If the date and time are not set, “-:--” appears during or after  
measurement.  
The Blood Pressure Monitor automatically stores up to 60 measurement  
values per user with the dates and times.  
The monitor can also calculate an average reading based on the three  
most recent measurements taken within 10 minutes of the last reading.  
NOTE: • If only two readings are stored in the memory for the 10-  
minute period, the average is based on the two readings.  
• If one reading is stored in the memory for the 10-minute  
period, this reading is displayed as the average.  
17  
 
SETTING THE DATE AND TIME  
1. TO START THE SETTING  
Press the SET button to adjust the date and time.  
The year flashes on the display.  
2. SETTING THE YEAR  
The year can be set between 2010 and  
2040. When the display reaches 2040,  
it will return to 2010.  
Press the Up button (  
by one year.  
) to advance  
Press the SET button to set the current  
year.  
The month flashes on the display.  
NOTES: • Press the Down button (  
) to decrease the date and time  
values.  
• Press and hold the Up or Down button to increase or  
decrease the date and time values faster.  
18  
 
SETTING THE DATE AND TIME  
3. SETTING THE MONTH  
Press the Up button (  
by one month.  
) to advance  
Press the SET button to set the current  
month.  
The day flashes on the display.  
4. SETTING THE DAY  
Press the Up button (  
by one day.  
) to advance  
Press the SET button to set the current  
day.  
The hour flashes on the display.  
19  
 
SETTING THE DATE AND TIME  
5. SETTING THE HOUR  
The time is set using AM or PM.  
Press the Up button (  
by one hour.  
) to advance  
Press the SET button to set the current  
hour.  
The minute flashes on the display.  
6. SETTING THE MINUTE  
Press the Up button (  
) to advance by one minute.  
Press the SET button to set the minute setting.  
7. TO TURN THE MONITOR OFF  
Press the START/STOP button.  
20  
 
APPLYING THE ARM CUFF  
CAUTION  
Read all of the information in the instruction manual and any other  
literature in the box before operating the unit.  
CAUTION  
This device is intended for use in measuring blood pressure and  
pulse rate in the adult population. Do not use this device on infants  
or persons who cannot express their intentions.  
APPLYING THE CUFF ON THE LEFT ARM  
1. Make sure the air plug is securely inserted in the main unit.  
2. Remove tight-fitting clothing from your upper left arm.  
21  
 
APPLYING THE ARM CUFF  
3. Hold the thumb grip on the cuff  
securely with your right hand.  
Thumb Grip  
Cloth Fastener  
4. Turn the palm of your left hand  
upward.  
5. Apply the cuff to your left upper arm so the blue stripe is on the  
inside of your arm and aligned with your middle finger. The air tube  
runs down the inside of your arm. The bottom of the cuff should be  
approximately 1/2" above your elbow.  
Blue Stripe  
1/2 inch (1 - 2 cm)  
Air Tube  
22  
 
APPLYING THE ARM CUFF  
6. Wrap the cuff firmly in place around your arm using the cloth  
fastener.  
23  
 
APPLYING THE ARM CUFF  
APPLYING THE CUFF ON THE RIGHT ARM  
When taking a measurement using the right arm use this instruction  
for Step 5 on page 22.  
Apply the cuff to your right upper arm so the thumb grip is centered  
on the inside of your inner arm. The bottom of the cuff should be  
approximately 1/2'' above your elbow.  
Thumb Grip  
NOTE: Be careful not to rest your arm on the air tube. This will restrict  
the flow of air to the cuff.  
24  
 
TAKING A MEASUREMENT  
The monitor automatically determines your ideal inflation level. In rare  
circumstances when a higher inflation may be necessary, the monitor  
automatically re-inflates the cuff up to 30 mmHg higher than the initial  
inflation and restarts the measurement.  
WARNING  
Contact your physician for specific information about your blood  
pressure. Self-diagnosis and treatment using measured results may  
be dangerous. Follow the instructions of your physician or licensed  
healthcare provider.  
CAUTION  
Operate the device only as intended. Do not use the device for any  
other purpose.  
CUFF WRAP GUIDE  
This monitor checks whether the arm cuff is applied correctly during the  
inflation. When the cuff is applied correctly,  
is displayed while  
taking a measurement or using the memory function. If the cuff is not  
applied correctly, is displayed. If is displayed, refer to the  
section “Applying the Arm Cuff”, reapply the cuff and take another  
measurement.  
25  
 
TAKING A MEASUREMENT  
1. Press the START/STOP button to turn the monitor on.  
All symbols appear on the display.  
2. Select your USER ID (A or B).  
3. Sit on a chair with your feet flat on the floor. Place your left arm  
on a table so the cuff is level with your heart.  
26  
 
TAKING A MEASUREMENT  
4. Press the START/STOP button.  
The cuff starts to inflate automatically. As the cuff inflates, the monitor  
automatically determines your ideal inflation level.  
This monitor detects the pulse during inflation. Do not move your arm  
and remain still until the entire measurement process is completed.  
NOTE: To stop the inflation or measurement, press the START/STOP  
button. The monitor will stop inflating, start deflating and will  
turn off.  
5. Inflation stops automatically and the measurement is started.  
As the cuff deflates, decreasing numbers appear on the display.  
The Heartbeat Symbol ( ) flashes at every heartbeat.  
27  
 
TAKING A MEASUREMENT  
6. When the measurement is complete, the arm cuff  
completely deflates. Your blood pressure and pulse  
rate are displayed.  
7. Press the START/STOP button to turn the  
monitor off.  
NOTE: The monitor will automatically turn  
off after two minutes.  
WARNING  
Contact your physician for specific information about your blood  
pressure. Self-diagnosis and treatment using measured results may be  
dangerous. Follow the instructions of your physician or licensed  
healthcare provider.  
WARNING  
DO NOT adjust medication based on measurement results from this  
blood pressure monitor. Take medication as prescribed by your physician.  
Only a physician is qualified to diagnose and treat High Blood Pressure.  
WARNING  
The monitor is not intended to be a diagnostic device.  
28  
 
TAKING A MEASUREMENT  
SPECIAL CONDITIONS  
CAUTION  
Inflating to a higher pressure than necessary may result in bruising  
where the cuff is applied.  
If your systolic pressure is known to be more than 220 mmHg, press  
and hold the START/STOP button until the monitor inflates 30 to 40  
mmHg higher than your expected systolic pressure.  
NOTES: • Do not apply more pressure than necessary.  
• The monitor will not inflate above 299 mmHg.  
When the measurement is complete, the arm cuff completely deflates.  
Your blood pressure and pulse rate are displayed.  
29  
 
USING THE MEMORY FUNCTION  
The monitor is designed to store the blood pressure and the pulse  
rate in the memory for two people (USER A and USER B) every time a  
measurement is completed.  
The monitor automatically stores up to 60 sets of measurement values  
(blood pressure and pulse rate) for each user (A and B). When 60 sets of  
measurement values are stored, the oldest record is deleted to save the  
most recent values.  
AVERAGING FUNCTION  
The monitor calculates the average reading based on the three most  
recent sets of measurement values taken within 10 minutes of the most  
recent reading.  
NOTES: • If two sets of measurement values are stored in the memory  
for the 10 minutes period, the average is based on the two  
sets of measurement values. If one set of measurement  
values is stored, this is displayed as the average.  
• When viewing the reading taken without setting the date and  
time, “-:--” is displayed instead of the date and time.  
30  
 
USING THE MEMORY FUNCTION  
TO DISPLAY THE MEASUREMENT VALUES  
1. Press the START/STOP button to turn the monitor on.  
2. Select your USER ID (A or B).  
3. Press the Memory button ( ).  
The Average Symbol ( ) appears on the display when the average  
reading is shown.  
4. Press the Down button (  
) to display the  
most recent set of measurement values on  
the screen. The values are displayed from  
the most recent to the oldest.  
Alternating display  
NOTES: • The date and time are alternately  
displayed with the measurement  
values.  
• The Memory number appears for a  
second before the pulse rate is  
displayed. The newest set is  
numbered “1”.  
Press the Up or Down button to display the next set of values.  
: To the older readings  
: To the more recent readings  
NOTE: Press and hold the Up or Down button to display the values faster.  
31  
 
USING THE MEMORY FUNCTION  
TO DELETE ALL VALUES STORED IN THE MEMORY  
The values stored in the memory are deleted by USER ID.  
You cannot partially delete values stored in the memory. All values will  
be deleted.  
1. Press the START/STOP button to turn the monitor on.  
2. Select your USER ID (A or B).  
3. While holding the Memory button ( ), press the START/STOP  
button down for more than 2 seconds until the display appears as it  
does in the following illustration.  
32  
 
Care and Maintenance  
CARE AND MAINTENANCE  
To keep your blood pressure monitor in the best condition and protect  
the unit from damage, follow the directions listed below:  
Keep the monitor in the storage case  
when not in use. Make sure the AC  
adapter is placed under the main unit so  
that it does not damage the display.  
Avoid kinking or sharply bending the AC  
Adapter cord.  
Do not forcefully bend the arm cuff or  
air tube. Do not fold tightly.  
Clean the monitor with a soft dry cloth. Do not use any abrasive  
or volatile cleaners. Do not attempt to clean the cuff.  
CAUTION  
Do not submerge the device or any of the components in water.  
Do not subject the monitor to extreme hot or cold temperatures,  
humidity or direct sunlight.  
CAUTION  
Store the device and the components in a clean, safe location.  
CAUTION  
Do not subject the monitor to strong shocks, such as dropping the  
unit on the floor.  
Remove the batteries if the unit will not be used for three months or  
longer. Always replace all the batteries with new ones at the same time.  
33  
 
CARE AND MAINTENANCE  
Use the unit consistent with the instruction provided in this manual.  
CAUTION  
Changes or modification not approved by Omron Healthcare will  
void the user warranty. Do not disassemble or attempt to repair the  
unit or components.  
CAUTION  
Use only Omron authorized parts and accessories. Parts and  
accessories not approved for use with the device may damage  
the unit.  
34  
 
ERROR INDICATORS AND TROUBLESHOOTING TIPS  
ERROR INDICATORS  
SYMBOL  
CAUSE  
CORRECTION  
Insert the plug securely. Refer to “Applying the  
Arm Cuff”.  
Air plug disconnected.  
Apply the arm cuff correctly. Refer to “Applying  
the Arm Cuff”.  
Arm cuff not applied correctly.  
Air is leaking from the arm cuff.  
Replace the cuff with the new one.  
Repeat measurement. Remain still and do not talk  
during measurement. Refer to “Taking a  
Measurement”.  
Cuff over or under inflated.  
If “E2” appears repeatedly, inflate the cuff manually  
until it is 30 to 40 mmHg above your previous  
measurement result. Refer to “Taking a Measurement”.  
The arm cuff was inflated above 299  
Do not inflate the cuff above 299 mmHg. Refer to  
mmHg when inflating the cuff manually. “Taking a Measurement”.  
Repeat measurement. Remain still and do not talk  
during measurement. Refer to “Taking a  
Measurement”.  
Movement during measurement.  
Clothing is interfering with the  
arm cuff.  
Remove any clothing interfering with the arm cuff.  
Refer to “Applying the Arm Cuff”.  
Device error.  
Contact Customer Service.  
Cuff is not applied correctly.  
Refer to “Applying the Arm Cuff”.  
Replace the four batteries.  
Refer to “Battery Installation”.  
Batteries are worn  
35  
 
ERROR INDICATORS AND TROUBLESHOOTING TIPS  
TROUBLESHOOTING TIPS  
PROBLEM  
CAUSES AND SOLUTIONS  
No power.  
Replace all four batteries with new  
ones.  
No display appears on the unit. Check the battery installation  
for proper placement of the  
battery polarities.  
Blood pressure varies constantly.  
Many factors including stress, time  
of day, and how you wrap the cuff,  
Measurement values appear  
too high or too low.  
may affect your blood pressure.  
Review the sections “Before Taking  
a Measurement” and “Taking a  
Measurement.”  
36  
 
FCC STATEMENT  
NOTE:  
POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only)  
This product has been tested and found to comply with the limits for a Class B  
digital device, pursuant to part 15 of the FCC rules.  
These limits are designed to provide reasonable protection against harmful  
interference in a residential installation. The product generates, uses, and can  
radiate radio frequency energy and, if not installed and used in accordance  
with the instructions, may cause harmful interference to radio communications.  
However, there is no guarantee that interference will not occur in a particular  
installation. If the product does cause harmful interference to radio or television  
reception, which can be determined by turning the product on and off, the  
user is encouraged to try to correct the interference by one or more of the  
following measures:  
• Reorient or relocate the receiving antenna.  
• Increase the separation between the product and the receiver.  
• Connect the product into an outlet on a circuit different from that to which  
the receiver is connected.  
• Consult the dealer or an experienced radio/TV technician for help.  
POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for Canada only)  
This digital apparatus does not exceed the Class B limits for radio noise  
emissions from digital apparatus as set out in the interference-causing equipment  
standard entitled “Digital Apparatus”, ICES-003 of the Canadian Department of  
Communications.  
Cet appareil numérique respecte les limites de bruits radioeléctriques applicables  
aux appareils numériques de Clase B prescrites dans la norme sur le materiel  
brouilleur: “Appareils Numériques”, ICES-003 édictée par le minister des  
communications.  
Changes or modifications not expressly approved by the party responsible for  
compliance could void the user’s authority to operate the equipment.  
37  
 
LIMITED WARRANTY  
Your Omron® BP762 Automatic Blood Pressure Monitor, excluding the arm cuff,  
is warranted to be free from defects in materials and workmanship appearing  
within 5 years from the date of purchase, when used in accordance with the  
instructions provided with the monitor. The arm cuff is warranted to be free from  
defects in materials and workmanship appearing within one year from the date of  
purchase when the monitor is used in accordance with the instructions provided  
with the monitor. The above warranties extend only to the original retail purchaser.  
We will, at our option, repair or replace without charge any monitor or arm cuff  
covered by the above warranties. Repair or replacement is our only responsibility  
and your only remedy under the above warranties.  
To obtain warranty service contact Customer Service by calling 1-800-634-4350  
for the address of the repair location and the return shipping and handling fee.  
Enclose the Proof of Purchase. Include a letter, with your name, address, phone  
number, and description of the specific problem. Pack the product carefully to  
prevent damage in transit. Because of possible loss in transit, we recommend  
insuring the product with return receipt requested.  
THE FOREGOING IS THE SOLE WARRANTY PROVIDED BY OMRON IN  
CONNECTION WITH THIS PRODUCT, AND OMRON HEREBY  
DISCLAIMS ANY OTHER WARRANTIES, EXPRESS OR IMPLIED,  
INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND  
FITNESS FOR A PARTICULAR PURPOSE. IMPLIED WARRANTIES AND  
OTHER TERMS THAT MAY BE IMPOSED BY LAW, IF ANY, ARE LIMITED  
IN DURATION TO THE PERIOD OF THE ABOVE EXPRESS WARRANTY.  
OMRON SHALL NOT BE LIABLE FOR LOSS OF USE OR ANY OTHER  
SPECIAL, INCIDENTAL, CONSEQUENTAIL OR INDIRECT COSTS,  
EXPENSES OR DAMAGES.  
This warranty provides you with specific legal rights, and you may have other  
rights that vary by jurisdiction. Because of special local requirements, some of  
the above limitations and exclusions may not apply to you.  
FOR CUSTOMER SERVICE  
Call toll free:  
1-800-634-4350  
38  
 
SPECIFICATIONS  
Model:  
Display:  
BP762 (HEM-7220-ZCS)  
LCD Digital Display  
Measurement Range: Pressure: 0 to 299 mmHg, Pulse: 40 to 180/min.  
Accuracy/Calibration: Pressure: 3mmHg or 2% of reading  
Pulse:  
5% of reading  
Inflation:  
Deflation:  
Rapid Air Release:  
Automatic by electric pump  
Automatic pressure release valve  
Automatic exhaust valve  
Measurement Method: Oscillometric method  
Power Source:  
Battery Life:  
120V 60Hz AC adapter or 4 “AA” batteries  
Approx. 500 uses when used 6 times a day  
with 4 new alkaline batteries  
Operating Temperature 50ºF to 104ºF (10ºC to 40ºC) /15 to 90% RH  
/Humidity:  
Storage Temperature  
/Humidity/Air Pressure: /700 - 1060 hPa  
Main Unit Weight: Approximately 15 1/8 oz. (430 g)  
not including batteries  
-4ºF to 140ºF (-20ºC to 60ºC) /10 to 95% RH  
Main Unit Dimensions: Approx. 6 1/4" (l) × 4 7/8" (w) × 3 5/16" (h)  
(158 mm × 124 mm × 86 mm)  
Cuff Size:  
Approximately 6" (w) (152 mm)  
Cuff tube 23 5/8" (l) (600 mm)  
Fits arm circumferences 9" to 17"  
(220 mm to 420 mm)  
Cuff Circumference:  
Memory:  
Contents:  
Up to 60 per user  
Main Unit, ComFit Cuff, AC Adapter,  
Instruction Manual, Quick Start Guide, Storage Case  
= Type B  
TM  
NOTE: These specifications are subject to change without notice.  
39  
 
Manufactured by OMRON HEALTHCARE Co., Ltd.  
Made in China  
Distributed by:  
Omron Healthcare, Inc.  
1200 Lakeside Drive  
Bannockburn, IL 60015  
Copyright © 2010 Omron Healthcare, Inc.  
 

Miller Electric Welder RHC 3 User Manual
Mountfield Lawn Mower EL 390R User Manual
NETGEAR Cordless Telephone SPH200D User Manual
NordicTrack Treadmill NCTL11990 User Manual
Onkyo Car Satellite TV System TX NR1007 User Manual
Palsonic CRT Television 8040PFST User Manual
Panasonic Cordless Telephone B02 User Manual
Panasonic Drill EY7460 User Manual
Panasonic Fax Machine KX FLB751AL User Manual
Panasonic Printer KX FLB881 User Manual