Panasonic Smoke Alarm 3339 User Manual

Fire alarm systems  
Enclosed  
addressable manual  
call point  
3339  
Attractive design compliant with EN54-11. IP rating IP67  
Test key for routine testing without breaking the glass element  
Protection against accidental operation  
General  
LED indicator  
An LED on the front cover indicates fire  
alarm generated by the call point.  
Flashing LED: The LED will flash each  
time the c.i.e. communicates with the call  
point, until the call point is operated and the  
LED is switched on.  
Non-flashing LED: The LED is switched  
off until the call point is operated and the  
LED is switched on.  
The call point has an attractive design  
compliant with EN54-11, and is surface  
mounted in the supplied red backbox. It has  
a clip retained front cover that makes it easy  
to replace the glass element and adds  
security since the clips are concealed. The  
frangible element is a glass element with a  
protective plastic film. To operate the call  
point, the glass element is pressed until it is  
broken. This will activate the built-in  
microswitch, which will generate a fire  
alarm in the c.i.e.  
Connections / Settings  
The COM loop is connected directly to the  
call point via a 4-way terminal block. For  
COM loop address setting is the address  
setting tool 3314 used. 3314 is also used to  
set the call point type and the LED mode:  
Test key  
Routine testing is made with a supplied test  
key, without breaking the glass element.  
Inserting the test key simulates the breaking  
of the glass element. The call point is  
automatically reset when the test key is  
removed. The test key is also used to  
release the security clips for the front cover.  
NORMAL mode:  
(EBL512 SW  
version >2.0 / EBL128). M.c.p. type  
3339. (Flashing or non-flashing LED is  
set via Win512 / Win128.)  
2330 mode: M.c.p. type 2339, flashing  
LED.  
2312 mode: M.c.p. type 2339, non-  
flashing LED.  
Protective cover  
To protect the call point against accidental  
operation, a transparent polycarbonate cover  
has to be lifted to get access to the glass  
element.  
Two flying leads (wires) are connected to  
the terminal block, for connection of the  
3314 address setting tool's connection cable.  
The wires are to be disconnected before the  
COM loop wires are connected.  
Encapsulated circuit  
All electronics are encapsulated. Only the  
terminal block is accessible from the rear.  
Mounted in the supplied red backbox and  
the tightening gasket on place (see the  
opposite page), the IP rating is IP67.  
Product applications  
Used in the systems EBL512 / 128 / 1000 /  
2000 and is intended for indoor use in  
premises where IP67 rating is required.  
Panasonic Electric Works Fire & Security Technology Europe AB  
Jungmansgatan 12, SE-211 19 Malmö, Sweden  
Tel: +46 (0)40 697 70 00 • Fax: +46 (0)40 697 70 99  
 

MTD Chainsaw 1425NAV User Manual
MTX Audio Car Stereo System TA3401 User Manual
NEC Projection Television GT1150 User Manual
New Holland Lawn Mower T7OOO User Manual
Niles Audio Speaker 15SW User Manual
Nortech Systems Portable DVD Player E DVKIT003 User Manual
NuTone Intercom System IA 28 User Manual
Olympus Camera Accessories SHV 1 User Manual
Palsonic TV Converter Box 5169M User Manual
Panasonic Washer CF Y2 User Manual