Parasound HCA-1200 High Current Power Amplifier  
Congratulations on your purchase of this precision audio component and thank you for your selection of  
Parasound. Your HCA- 1200 has been designed with the latest technology to become the heart of the finest  
music systems. Its high power output is matched by enormous current capacity to drive virtually any speak-  
ers known. A lkVA toroid transformer and 60,000µfd power supply assure power in reserve. A Class A  
cascode input stage, mosfet driver stage and ultra-fast discrete AB output stage assure flawless reproduc-  
tion. You have made an excellent choice.  
Please take a few moments now to read these instructions thoroughly so you may fully understand the  
sophisticated capabilities of your new power amplifier.  
Unpacking  
Save your carton and the styrafoam inserts for future safe transportation in case you move or the unit ever  
requires shipping for repair. Note, the actual printed carton is not itself strong enough for safe shipping, so  
you must place it into an additional outer 'overcarton' before shipment.  
Before you proceed, find the serial number which is located on the rear panel of the unit and note it here for  
future reference or in case the unit is ever stolen ____________________.  
 
Placement of your HCA-1200  
Keep your Parasound HCA- 1200 out of direct sunlight and away from windows which could ever be left  
open to let in rain. It should be placed away from heat sources such as hot air ducts or radiators; do not place  
the unit directly on a pile carpet that could interfere with air flow into its bottom vent openings. If you place  
the HCA-1200 on the floor near your speakers, elevate it up from the pile of the carpet. If you stack your  
components, it is better to place the HCA-1200 above or alongside your other components; when driven  
hard, the unit itself may create a little heat and disturb components stacked on top of it. If it is inside a  
cabinet, allow ample ventilation. Very sensitive low level sources might pick up some hum radiated from its  
enormous power supply.  
Rack mounting the HCA-1200  
The HCA-1200 can be mounted to a 19" rack by attaching the optional RMK-1000 Rack Mount Kit as  
shown below. Please note, the panel size of the HCA-1200 is 5 1/2" high, which is 1/4" taller than a standard  
EIA 3-space rack. You may find you need to drill new mounting holes in your rack to accommodate it  
properly.  
To attach the RMK-1000, first remove the  
three bolts at each side of the cover - closest  
to the front panel. Use the 6 longer bolts  
supplied in the rack mount kit to attach both  
panel extension/chassis supports.  
Tighten these firmly, as they bear the full  
weight of the amplifier.  
(Sorry RMK-1000s are no longer available)  
Making Connections  
Before making any connections, make sure your power amplifier is turned off. When making connections,  
make sure there is no strain or tension on input leads or speaker wires that could cause them to pull loose  
later on.  
Input connections  
In most stereo systems, you will use the gold-plated RCA jacks for the R and L channels. Make sure these  
are consistent with the R and L outputs from your preamplifier.  
For professional applications you can use the alternate 1/4"(6.3mm) phone jack inputs. These are also "un-  
balanced" inputs, the same as the RCA jacks.  
Speaker connections  
You may use either bare wire or banana plugs with the HCA-1200 "5-way" terminals. If you use bare wire  
without spade lugs or plugs, make sure you strip only enough wire to fit into the hole that runs across the  
metal shaft of the terminal. Before inserting the wire, twist all its strands tightly to prevent strays that could  
cause a short circuit between + and - terminals!  
- 3 -  
 
Polarity  
It is important to observe correct polarity when using in stereo mode. One side of the speaker lead will have  
some sort of mark, either printing, a raised ridge on the insulation or different color of conductor. This  
permits you to know which wire you had connected to the + and which to the speaker terminals so you can  
do exactly the same at the power amplifier terminals.  
Mono Mode  
Hookup  
For mono, you will use only the red + speaker terminals for your speaker. In this case, you must also move  
the recessed mono/stereo slide switch to mono before turning on to avoid damage to your amplifier. You will  
only need to connect the mono input lead to the amplifier's R channel.  
Mono/Stereo Switch  
This switch is recessed so it cannot accidentally be moved. Never move this switch while the amplifier is  
turned on!  
Minimum Impedance  
The minimum recommended load for mono is 8 . If you know that your speakers have a uniform imped-  
ance curve and do not attempt to drive the unit to high sustained levels, you may use a 4 load. To be safe,  
it is better to use a minimum 8 load.  
These restrictions result from the mathematics of the bridging circuitry: in bridge mode each channel of the  
amplifier functions for either the + or - half of the musical waveform. Thus, each channel "sees" one half the  
speaker's impedance. Use of an 8 speaker means that the load for each channel is 4 . And for a 4 Ω  
speaker, it results in only 2 .  
Use good wire  
For best results you should never use speaker wire thinner than 16 gauge. You may also wish to experiment  
with audiophile-grade speaker wire and interconnects. Each will have a different characteristic sound and  
some may be more compatible with the sonic signature of your various components. The HCA-1200 is  
stable with any reputable brand of wire.  
AC Line cord  
You can plug this into a wall socket or an AC outlet on your preamplifier. If you plan to leave the HCA-1200  
power switch on and turn it on and off with the preamp, make sure its power switch is rated for the full  
current draw of the HCA-1200. The HCA-1200 has a surge resistor in its power supply so it is less likely to  
damage a preamp's on/off switch. The bigger risk is during turn off while music is playing at high levels.  
This situation could send a damaging surge back down the amp's AC cord as the power supply "collapses"  
and burn out the preamp's on/off power switch.  
Connecting the HCA-1200 to a preamp which has a relatively light duty power cord or extending its power  
cord with a flimsy extension cord will impair the sound reproduction of the HCA-1200.  
- 4 -  
 
Operating the HCA-1200  
Power Switch  
Press once to tum the unit on. Press again to tum it off.  
Level Controls  
Adjust the gain of each channel independently. Many preamps have volume controls which do not track  
correclly to preserve channel balance at the lowest end of their rotation. By reducing the settings of the  
HCA-1200 level controls you can use the preamp volume control in its optimum range.  
Standby LED  
This red LED will come on whenever you first tum the unit on. It will light for about four to five seconds  
while the circuit is stabilizing before the protection relays click on. It will also light up whenever there is a  
short circuit or fault which triggers the protection relays.  
Operation LED  
This green LED comes on after the protection relay click on. If the amp gets into trouble, the green operation  
light will extinguish, advising you no sound can be heard.  
Overload LEDs  
These LEDs will light up whenever the amplifier is pushed toward its clipping point. They are an indication  
that the amplifier is being overdriven and alert you to pending distortion. If you are driving speakers at a  
very high level, it is normal for these to flash occasionally on peaks in the program material.  
High Temp LEDs  
These will alert you to a pending thermal overload of the unit. If the amplifier is overdriven, as it builds up  
heat, thermal-tracking sensors will activate protection circuits to keep the unit from frying its power trans-  
former or solid state devices. If you find the High Temp LEDs coming on, it is a likely sign that you are  
trying to get too much out of the unit for the speakers you are using. It is also a sign that the load impedance  
is too low for safe operation.  
Protection Circuits  
The HCA-1200 has numerous protection circuits. If any are triggered, the red Standby LED will come on.  
Afler the fault has been corrected, the unit will automatically reset itself for normal operation. But it is  
always a good idea to tum off the power switch while you are trouble-shooting for shorted connections or  
faults with source components.  
Fuses  
The HCA-1200 has several intemal fuses which may blow as a result of an intemal fault condition. This  
protects the unit from possible damage to intemal parts. You should not attempt to replace intemal fuses  
yourself - there are dangerous high voltages stored in the power supply even after power has been tumed off  
or the unit has been unplugged. In any case, never replace any fuse with a larger value. Substitution of a  
larger fuse may create serious stress or damage to intemal parts and will void your warranty.  
- 5 -  
 
Breaking in the HCA-1200  
Like other great power amplifiers, the HCA-1200 requires about 24 hours of operation after it is first turned  
on to sound its best. This gives delicate capacitors a chance to "form" and pass audio signals with greater  
definition, smoothness and transparency.  
Although the HCA-1200 will sound spectacular when you first operate it, you will find it worthwhile to  
listen again after a few days and you'll discover details in your music you may not have guessed were there.  
Maintaining your HCA-1200  
The HCA-1200 requires no periodic maintenance and has no user serviceable parts inside. Do not remove  
the top cover to avoid risk of electric shock. To keep it clean use only a soft cloth and never use any solvents  
or abrasives. Fingerprints may be removed with a soft cloth moistened only with a few drops of water.  
The HCA-1200 has corrosion-free gold input jacks, but each year it is a good idea to twist the input plugs to  
preserve perfect signal transfer by removing corrosion which might have accumulated on the connecting  
plugs themselves. Make sure the unit is turned off while you do this.  
In Case of Trouble  
If you suspect a problem with this unit, first recheck all your connections. If one channel is inoperative, the  
trouble maybe caused by another component or even a defective hookup cable. If only one channel is out for  
all sources, try reversing the L and R cables to the power amplifier (turn it off before moving wires). If the  
same channel stays out, it indicates trouble with the power amplifier itself. We suggest you contact your  
authorized Parasound dealer or call Parasound Technical Service if you suspect a problem. We will suggest  
other diagnostic tests you can easily perform yourself and which will save you a lot of trouble.  
If it is determined that the HCA-1200 should be returned for inspection and possible servicing, you must  
first obtain a Return Authorization number. You will be asked to repack the unit in its original carton and  
styrofoam packing plus an additional outer box over its own box for proper protection in transit. You should  
send the unit by UPS with adequate insurance specified.  
Units that arrive without the connect Return Authorization number, without a suitable shipping carton or  
evidence of improper internal packing or collect will be refused. We cannot accept collect shipments. After  
repair under warranty, the unit will be returned to you via prepaid UPS. If we found no problem with the  
unit, we will ship the unit by UPS collect for its return shipping charges.  
- 6 -  
 
HCA-1200 Specifications  
Specifications subject to change without notice.  
Continuous Power output - stereo  
200 watts RMS x 2, 20Hz-20kHz, 8 Ω  
300 watts RMS x 2, 20Hz-20kHz, 4 Ω  
Continuous Power output - mono  
600 watts RMS, 20Hz-20kHz, 8 Ω  
600 watts RMS, 20Hz-20kHz, 4 Ω  
Current Capacity  
40 amperes continuous  
57 amperes peak, up to 200msec.  
Slew Rate  
100V/µsecond  
Frequency response  
8Hz-90kHz, +0/-3dB  
Total Harmonic Distortion  
< 0.08% at full power  
< 0.03% typical levels  
TIM  
Unmeasurable  
IM distortion  
< 0.1%  
Dynamic Headroom  
> 1.5dB  
Input impedance  
30 kΩ  
S/N ratio  
>110dB, input shorted, IHF A weighted  
Damping factor  
Over 120 at 20Hz  
Dimensions  
17 1/4" wide x 5 1/2" high x 12" deep; 19" wide using RMK-1000 rack mount  
Weight  
38 lbs.  
Special Features  
1kVA toroid power transformer  
60,000µfd gold capacitors in power supply  
60MHz output transistors, in AB mode  
Cascode Class A J-FET input stage  
Linear Hi-Z FET driver stage  
Gold-plated input jacks  
Multiple relay protection  
Mono bridgeable  
- 7 -  
 
Parasound Limited Warranty (USA only)  
Your Parasound HCA-1200 is covered by a limited warranty against defects in materials and workmanship  
for a period of two years from date of purchase. This warranty is provided by the Parasound dealer where the  
unit was purchased. Warranty repair will be performed only when your purchase receipt is presented as  
proof of ownership, date of purchase and authorized status of the dealer. Defective parts will be repaired or  
replaced without charge by your authorized dealer's store or the location designated by your dealer that is  
authorized to service Parasound equipment. Additional information is available by calling or writing to the  
Service Manager, Parasound Products,Inc. at the address below. Charges for unauthorized service and trans-  
portation costs are not reimbursable under this warranty.  
This warranty becomes void if the product has been damaged by alteration, misuse, accident or neglect. This  
warranty becomes void if unit has been burned out by extended testing or listening with load impedances  
contrary to printed instructions. This warranty applies only to units used in residential, non-commercial  
situations. The warrantor assumes no liability for property damage or any other incidental or consequential  
damage whatsoever which may result from the failure of this product. Any and all warranties of merchant-  
ability and fitness implied by law are limited to the duration of this expressed warranty.  
Some states do not allow limitations on how long an implied warranty lasts, so the above  
limitations may not apply to you. Some states do not allow the exclusion or limitation of incidental or  
consequential damages, so the above limitation or exclusion may not apply to you.  
This warranty gives you specific legal rights and you may also have other rights which vary state by state.  
Please Stay in Touch  
We'd like to hear from you about your experience with your Parasound HCA-1200. Of course we want to  
assist you with any questions you may have, but we'd also be thrilled to know how much you are enjoying  
the unit. You don't need to have a problem as an excuse to call.  
Reviews are coming in from all over the world and we continually have exciting new products in develop-  
ment. If you'd like us to keep you advised, just drop a line and ask to receive updates. We welcome your  
suggestions and look forward to hearing from you.  
Parasound Products, Inc. 950 Battery Street San Francisco, CA 94111  
Tel 415 397-7100 Fax 415 397-0144  
© 1990, Parasound Products, Inc.  
- 8 -  
 

Miele Refrigerator 09 476 230 User Manual
Miller Electric Portable Generator CBI 801D User Manual
NHT Speaker VT 3 User Manual
Niles Audio Door 6P User Manual
Nilfisk Advance America Boiler GR 8000 User Manual
NuTone Ventilation Hood QTREN User Manual
Omron Scale BF400 User Manual
Orion Car Audio Stereo Amplifier CO2100 User Manual
Panasonic Blu ray Player DMP BD45 User Manual
Panasonic Ventilation Hood FV 08VSL3 User Manual