Regency Indoor Fireplace U32 LP5 User Guide

Gas Inserts  
U32 Regency Gas Insert  
U32 Regency Gas Insert  
Model  
U32-NG5  
U32-LP5  
Fuel Type  
Natural Gas  
5” W.C. (1.25 kPa)  
3.8” W.C. (0.95 kPa)  
1.1” W.C. (0.27 kPa)  
#37 DMS  
Propane  
Minimum Supply Pressure  
Manifold Pressure - High  
Manifold Pressure - Low  
Orice Size -Altitude 0-4500 ft.  
12” W.C. (2.99 kPa)  
11” W.C. (2.74 kPa)  
2.9” W.C. (0.72 kPa)  
#52 DMS  
Minimum Input  
Altitude 0-4500 ft. (0-1372m)  
15,300 BTU/h  
(4.48 kW)  
15,000 BTU/h  
(4.40 kW)  
Maximum Input  
Altitude 0-4500 ft. (0-1372m)  
30,000 BTU/h  
(8.79 kW)  
30,000 BTU/h  
(8.79 kW)  
Vent Sizing  
3” Co-linear  
3” Co-linear  
Approved Venting Systems  
Flex Vent Systems:  
FPI AstroCap™ Flex Vent  
A
Minimum Fireplace Dimensions  
The minimum replace dimensions for the FPI gas replace insert are  
shown in the following diagrams:  
B
C
G
I
F
M
L
J
H D  
E
K
N
Dimension Description  
U32  
A
B
C
D
E
F
G
H
I
Faceplate Width  
Faceplate Height  
Unit Width  
40-1/4” (1022mm)  
26-1/4” (667mm)  
28” (711mm)  
Contour  
Molded  
Dimension Description  
Unit Height  
20” (508mm)  
Faceplate  
Faceplate  
Unit Depth  
13-3/4” (349mm)  
10-3/4” (273mm)  
1-3/8” (35mm)  
21-1/16” (535mm)  
3-3/4” (95mm)  
J
Height  
22” (559mm)  
26-1/2” (673mm)  
14” (356mm)  
22” (559mm)  
29” (737mm)  
15” (381mm)  
10” (254mm)  
22-1/2” (572mm)  
Faceplate to Vent Centerline  
Faceplate Depth  
K
L
Width  
Depth  
M
N
Max. Lintel Bar Depth  
Rear Width  
9” (229mm)  
Height to Vent Collar  
22-1/2” (572mm)  
Optional or Standard Front Depth  
August 2008 Product Specications Book  
 
125  

Radio Shack Network Card 273 353 User Guide
Radio Shack Scanner PRO 27 User Guide
RCA Camcorder CC6254 User Guide
RCA DVD Player DRC620N User Guide
RCA Microwave Oven RMW1163 User Guide
Rowenta Hair Dryer CV8010 User Guide
Runco Computer Monitor High Definition User Guide
Runco Headphones CW 95DHD User Guide
Sanyo Car Stereo System DC DAB03 User Guide
Sanyo Vacuum Cleaner SC X2017 User Guide