H8/3257 Series, H8/325 Series FP-64A
User System Interface Cable
(HS3257ECH61H)
for E6000 Emulator
User’s Manual
ADE-xxx-xxx
Rev. 3.0
4/1/03
Renesas Technology Corp.
HS3257ECH61HE
Preface
Thank you for purchasing the E6000 emulator for the Renesas’s original microprocessor H8/300
series.
The HS3257ECH61H is a user system interface cable that connects an H8/300 series E6000
emulator (HS3008EPI60H; hereinafter referred to as the emulator) to the IC socket for a FP-64A
package for the H8/3257 series, H8/325 series MCU on the user system.
i
Contents
Section 1 Configuration.....................................................................................1
Section 2 Connection Procedures......................................................................3
2.1 Connecting User System Interface Cable to Emulator Station .........................................3
2.2 Connecting User System Interface Cable to User System ................................................4
2.2.1 Installing IC Socket .............................................................................................4
2.2.2 Soldering IC Socket.............................................................................................5
2.2.3 Inserting Cable Head ...........................................................................................5
2.2.4 Fastening Cable Head ..........................................................................................5
2.2.5 Fastening Cable Body..........................................................................................7
2.3 Recommended Dimensions for User System Mount Pad .................................................8
2.4 Dimensions for User System Interface Cable Head..........................................................9
2.5 Resulting Dimensions after Connecting User System Interface Cable.............................10
Section 4 Verifying Operation...........................................................................13
Section 5 Notice ................................................................................................14
ii
Section 1 Configuration
CAUTION
Use an IC149-064-008-B5 socket (manufactured by
YAMAICHI ELECTRONICS Co., Ltd.) for the FP-64A package
IC socket on the user system.
Figure 1 shows the configuration of the HS3257ECH61H user system interface cable for the
FP-64A package
Screws (M2.0 x 12 mm)
and flat washers
(For fastening cable
head)
Screws (M2.0 x 8 mm)
and flat washers
Socket cover
Cable head
IC socket
User system
Figure 1 HS3257ECH61H User System Interface Cable
1
Table 1 lists the HS3257ECH61H components. Please make sure you have all of these
components when unpacking.
Table 1
HS3257ECH61H Components
No. Component
Quantity
Remarks
1
2
3
4
5
6
Cable body
1
1
1
1
4
4
Includes cables
Cable head
IC socket
For the FP-64A package
Socket cover
For installing an FP-64A-packaged MCU
For fastening cable head (with four flat washers)
Screws (M2.0 x 12 mm)
Screws (M2.0 x 8 mm)
For installing an FP-64A-packaged MCU (with
four flat washers)
7
Documentation
1
User’s manual for HS3257ECH61H (this manual)
2
Section 2 Connection Procedures
2.1
Connecting User System Interface Cable to Emulator Station
WARNING
Observe the precautions listed below. Failure to do so
will result in a FIRE HAZARD and will damage the user
system and the emulator product or will result in
PERSONAL INJURY. The USER PROGRAM will be
LOST.
1. Always switch OFF the user system and the emulator
product before the USER SYSTEM INTERFACE CABLE
is connected to or removed from any part. Before
connecting, make sure that pin 1 on both sides are
correctly aligned.
2. The user system interface cable dedicated to the
emulator must be used.
To connect the cable body to the emulator station, follow the instructions below.
1. Make sure the user system and emulator station are turned off.
2. After making sure the direction of the cable body connector is correct, firmly insert the cable
body connector into the emulator station socket (figure 2).
3
Figure 2 Connecting User System Interface Cable to Emulator Station
2.2
Connecting User System Interface Cable to User System
WARNING
Always switch OFF the user system and the emulator
product before the USER SYSTEM INTERFACE CABLE
is connected to or removed from any part. Before
connecting, make sure that pin 1 on both sides are correctly
aligned. Failure to do so will result in a FIRE HAZARD and
will damage the user system and the emulator product or
will result in PERSONAL INJURY. The USER PROGRAM will
be LOST.
To connect the cable head to the user system, follow the instructions below.
2.2.1 Installing IC Socket
After checking the location of pin 1 on the IC socket, apply epoxy resin adhesive to the bottom of
the IC socket for an FP-64A package, and fasten it to the user system before soldering.
4
2.2.2
Soldering IC Socket
After fastening, solder the IC socket for an FP-64A package to the user system. Be sure to
completely solder the leads so that the solder slops gently over the leads and forms solder fillets.
(Use slightly more solder than the MCU.)
2.2.3
Inserting Cable Head
CAUTION
Check the location of pin 1 before inserting.
Align pin 1 on the IC socket for an FP-64A package on the user system with pin 1 on the user
system interface cable head, and insert the user system interface cable head into the IC socket on
the user system, as shown in figure 3.
2.2.4
Fastening Cable Head
CAUTION
1. Use a Phillips-type screwdriver whose head matches
the screw head.
2. The tightening torque must be 0.0784 N•m or less.
If the applied torque cannot be accurately measured,
stop tightening when the force required to turn the screw
becomes significantly greater than that needed when first
tightening. If a screw is tightened too much, the screw
head may break or an IC socket contact error may be
caused by a crack in the IC socket solder.
3. If the emulator does not operate correctly, cracks might
have occurred in the solder. Check conduction with
a tester and re-solder the IC socket if necessary.
Fasten the user system interface cable head to the IC socket for an FP-64A package on the user
system with the four screws (M2.0 x 12 mm) provided. Each screw should be tightened a little at
a time, alternating between screws on opposing corners. Take special care, such as manually
securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by
overtightening the screws or twisting the components.
5
Screws (M2.0 x 12 mm)
and flat washers
Cable head
Pin 1
IC socket
(IC149-064-008-B5
manufactured by
YAMAICHI ELECTRONICS
Co., Ltd.)
User system
Figure 3 Connecting User System Interface Cable to User System
6
2.3
Recommended Dimensions for User System Mount Pad
Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system
with an IC socket for an FP-64A package (IC149-064-008-B5: manufactured by YAMAICHI
ELECTRONICS Co., Ltd.). Note that the dimensions in figure 5 are somewhat different from
those of the actual chip's mount pad.
20.80 min
14.80 max
0.80 x 15 = 12.00 ± 0.10
+ 0.10
0.45
-
0.05
0.80 ± 0.05
Unit: mm
Figure 5 Recommended Dimensions for Mount Pad
8
2.5
Resulting Dimensions after Connecting User System Interface Cable
The resulting dimensions, after connecting the user system interface cable head to the user system,
are shown in figure 7.
Unit: mm
Tolerance: ± 0.5 mm
IC socket
(IC149-064-008-B5
User system
manufactured by
YAMAICHI ELECTRONICS Co., Ltd.)
Figure 7 Resulting Dimensions after Connecting User System Interface Cable
10
Section 3 Installing the MCU to the User System
CAUTION
1. Check the location of pin 1 before inserting.
2. Use a Phillips-type screwdriver whose head matches
the screw head.
3. The tightening torque must be 0.0784 N•m or less.
If the applied torque cannot be accurately measured,
stop tightening when the force required to turn the screw
becomes significantly greater than that needed when first
tightening. If a screw is tightened too much, the screw
head may break or an IC socket contact error may be
caused by a crack in the IC socket solder.
4. If the MCU does not operate correctly, cracks might have
occurred in the solder. Check conduction with a tester
and re-solder the IC socket if necessary.
Check the location of pin 1 before inserting the MCU into the IC socket on the user system, as
shown in figure 8. After inserting the MCU, fasten the socket cover with the provided four
screws (M2.0 x 8 mm). Take special care, such as manually securing the IC socket soldered area,
to prevent the IC socket from being damaged by overtightening the screws or twisting the
components.
11
Socket cover
MCU
Pin 1 mark
IC socket
(IC149-064-008-B5
manufactured by
YAMAICHI ELECTRONICS Co., Ltd.)
User system
Figure 8 Installing MCU to User System
12
Section 4 Verifying Operation
1. When using the H8/300 series E6000 emulator (HS3008EPI60H), turn on the emulator
according to the procedures described in the H8/300 Series E6000 Emulator User's Manual
(HS3008EPI60HE).
2. Verify the user system interface cable connections by accessing the external memory and ports
to check the bus states of the pins. If an error is detected, recheck the soldered IC socket and
the location of pin 1.
3. The emulator connected to this user system interface cable supports two kinds of clock
sources: an emulator internal clock and an external clock on the user system. For details, refer
to the H8/300 Series E6000 Emulator User's Manual (HS3008EPI60HE).
To use the emulator internal clock
Select the clock in the emulator station as the system clock (φ), by using the CLOCK
command (emulator command).
To use the external clock on the user system as the system clock
Select target clock t or t with the CLOCK command (emulator command). Supply the
external clock from the user system to the emulator. Connect a crystal oscillator to the
EXTAL and XTAL terminals for the system clock. The system clock (φ) has the same
frequency as the external clock.
Figure 9 shows the oscillator circuit on the user system interface cable.
R1 1 MΩ
HCU04
HCU04
R2 270
To E6000
emulator
Ω
EXTAL
XTAL
System clock
Figure 9 Oscillator Circuit
13
Section 5 Notice
1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable
head before inserting the cable head into the user system IC socket.
2. The dimensions of the recommended mount pad for the user system IC socket are different
from those of the MCU.
3. This user system interface cable is specifically designed for the HS3008EPI60H emulator. Do
not use this cable with any other emulator station.
4. To prevent breaking of wires in the cable body, do not place heavy or sharp metal objects on
the user system interface cable.
5. While the emulator station is connected to the user system with the user system interface
cable, force must not be applied to the cable head. Place the emulator station, user system
interface cable, and user system as shown in the example in figure 10.
Figure 10 User Cable Location Example
6. The P1 short connector is used for testing. Do not remove the inserted jumper pin.
P1
Figure 11 P1 Short Connector
14
|