Outdoor Stand-Alone
Weatherproof Keypads
Quick User Programming Guide
(SK-2323-SDQ shown)
(SK-1323-SPQ shown)
Model
Number
2 Relay
Outputs
Backlit
Keys
Proximity
Reader
Mullion-Style Keypads
SK-2323-SDQ
SK-2323-SPQ
Sealed-Environment Keypads
SK-1323-SDQ
SK-1323-SPQ
For complete programming instructions, please see page 10 of the User Manual.
NOTE: Products with a model number that ends with “Q” or have a round green “Q” sticker represent RoHs compliant products.
ENFORCER Outdoor Stand-Alone Keypad Quick Programming Guide
Programming Output #1
Each Output #1 user can be programmed to have a user code and a user card.*
1.1 User Code Only
1. Enter Programming Mode by entering the Master Code twice.
0
0
0
9
9
9
(
to
)
2. Enter a user ID number.
3. If the left LED is red, previous user data exists. Clear it by entering
The keypad will beep in confirmation and the left LED will turn green.
4. Enter a new 5-digit user code.
.
5. To program the next user, repeat from step 2 in section 1.1, 1.2, or 1.3.
6. Exit Programming Mode by pressing
.
1.2 User Card Only*
1. Enter Programming Mode by entering the Master Code twice.
0
0
0
9
9
9
(
to
)
2. Enter a user ID number.
3. If the left LED is red, previous user data exists. Clear it by entering
The keypad will beep in confirmation and the left LED will turn green.
4. Swipe a new user card.
.
5. Return to Programming Mode by pressing
.
6. To program the next user, repeat from step 2 in section 1.1, 1.2, or 1.3.
7. Exit Programming Mode by pressing
again.
1.3 User Card and Code*
1. Enter Programming Mode by entering the Master Code twice.
0
0
0
9
9
9
(
to
)
2. Enter a user ID number.
3. If the left LED is red, previous user data exists. Clear it by entering
The keypad will beep in confirmation and the left LED will turn green.
4. Swipe a new user card.
.
5. Enter a new 5-digit user code.
6. To program the next user, repeat from step 2 in section 1.1, 1.2, or 1.3.
7. Exit Programming Mode by pressing
.
*SK-2323-SPQ and SK-1323-SPQ only.
SECO-LARM U.S.A., Inc
3
ENFORCER Outdoor Stand-Alone Keypads Quick Programming Guide
Programming Output #2
Each Output #2 user may only have a user code OR a user card programmed.
2.1 Programming an Output #2 User Code
1. Enter Programming Mode by entering the Master Code twice.
4
2. Enter
.
( 0 0 to
)
0
9
3. Enter a user ID number.
4. If the left LED is red, previous user data exists. Clear it by entering
The keypad will beep in confirmation and the left LED will turn green.
5. Enter a new 5-digit user code.
.
6. To program the next user, repeat from step 3 in section 2.1 or 2.2.
7. Return to Programming Mode by pressing
.
8. Exit Programming Mode by pressing again .
2.2 Programming an Output #2 User Card*
1. Enter Programming Mode by entering the Master Code twice.
4
2. Enter
.
0
0
(
to
0
9 )
3. Enter a user ID number.
4. If the left LED is red, previous user data exists. Clear it by entering
The keypad will beep in confirmation and the left LED will turn green.
5. Swipe a new user card.
.
6. To program the next user, repeat from step 3 in section 2.1 or 2.2.
7. Return to Programming Mode by pressing
.
8. Exit Programming Mode by pressing
again.
*SK-2323-SPQ and SK-1323-SPQ only.
NOTICE: The information and specifications printed in this manual are current at the time of publication. However, the SECO-LARM policy
is one of continual development and improvement. For this reason, SECO-LARM reserves the right to change specifications without notice.
SECO-LARM is also not responsible for misprints or typographical errors.
Copyright © 2010 SECO-LARM U.S A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in part, without
the written permission of SECO-LARM.
SECO-LARM® U.S.A., Inc.
PICCN2
16842 Millikan Avenue, Irvine, CA 92606
E-mail: [email protected]
SK-x323-SxQ Addendum_1008.docx
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326
4
SECO-LARM U.S.A., Inc.
|