Sanyo Heat Pump 24THS32 User Guide

SUBMITTAL SHEET  
SYSTEM  
INDOOR/OUTDOOR  
AIRCONDITIONING PRODUCTS  
SS24THS32-1  
24THS32  
THS2432/CH2432  
CEILING SUSPENDED HEAT PUMP  
GENERAL DATA  
(AT 230V)  
PERFORMANCE DATA @ ARI STANDARD CONDITIONS (230/208V)  
COOLING  
POWER V/PH/HZ  
Circuit Ampacity, Min. (A)  
230/208/1/60  
30  
30  
Total Capacity  
(BTU/H)  
22,400/21,600  
13,640/12,970  
8,760/8,630  
10.0/10.0  
Fuse size, Max  
(A)  
Sensible Capacity (BTU/H)  
Latent Capacity (BTU/H)  
SEER  
COMPRESSOR  
No. used  
R.L. Amps - L.R. Amps (A)  
Crankcase Heater  
Rotary-Hermetic  
1
9.4 - 66.0  
30W  
Dehumidification (Pints/H)  
Amps (A)  
6.3/6.2  
10.7/11.3  
Power Inputs (W)  
2,290/2,250  
OUTDOOR FAN - TYPE  
Dia. (in.) - No. used  
Type Drive - No. speeds  
No. Poles - RPM (High)  
No. Motors ñ HP  
Propeller  
18-3/32- 1  
Direct ñ 2 (AUTO)  
6 - 879  
1 - 1/7  
1,840  
HEATING  
Total Capacity  
HSPF  
Amps (A)  
Power Inputs (W)  
(BTU/H)  
25,400/25,000  
7.0/7.0  
11.7/12.9  
2,350/2,280  
1.80/1.47  
7.6  
CFM (High)  
F.L. Amps. (A)  
Back-up Strip Heater (KW)  
Outdoor Sound Rating(bels)  
0.9  
OUTDOOR COIL ñ TYPE  
Fin Type - Pipe Type  
Rows - F.P.I.  
Face Area (sq.ft.)  
Tube Size (in.)  
Aluminum Fin & Copper Pipe  
Slit Plate - Inner Riffled  
2- 14.1  
6.78  
3/8  
FEATURE  
Controls  
Microprocessor  
LCD Wireless type  
IC Thermostat  
ON/OFF, 24 hours  
Built-In  
Remote Controller  
Temperature Control  
Timer  
INDOOR FAN ñ TYPE  
Centrifugal  
Night Setback  
Dia. & Length (in.) - No. used 5-1/8 & 4  
Air Louver (Horizontal)  
(Vertical)  
Power Failure Automatic Restart  
Self Diagnosis  
Manual  
Automatic  
Built-In  
N/A  
No. speeds  
3 & Auto  
4-1,187  
1 - 1/24  
540/490/425  
0.4  
No. Poles -RPM (High)  
No. Motors - HP  
CFM (HI/MED/LOW)  
F.L. Amps (A)  
OPTION  
INDOOR COIL - TYPE  
Fin Type - Pipe type  
Rows - F.P.I.  
Face Area (sq. ft.)  
Tube Size (in.)  
Aluminum Fin & Copper Pipe  
Slit Plate - Inner Riffled  
3 - 14.9  
1.81  
3/8  
Refrigerant Line Set  
AP2710BH (30 ft)  
AP2715BH (50 ft)  
Low Ambient Control  
Fresh Air Intake  
Central Remote ON-OFF Control  
Airduct Extension  
Built-In  
N/A  
Available  
N/A  
Drain Connection Size (in.)  
1-1/4  
REFRIGERANT  
Lbs. - R22 (O.D. Unit)  
Control  
R22  
6.17  
Capillary Tube  
Indoor Frame Extension  
Condensate Drain Pump  
Non-Removable Remo-con Bracket  
N/A  
Available  
RCS5PS4B  
Connection  
Electronic Refrigerant Control Valve  
Line Length, Max (ft.)  
Lift difference, Max (ft.)  
165  
100  
OPERATING RANGE  
Line Size - in. O.D. Discharge 1/4  
Line Size - in. O.D. Suction 3/4  
Cooling  
Indoor Air  
Outdoor Air  
Intake Temp.  
115F DB  
23F DB  
75F DB/67F WB  
17F DB/15F WB  
Intake Temp.  
95F DB/71F WB  
67F DB/57F WB  
Maximum  
Minimum  
DIMENSIONS (in.)  
Indoor Unit -Uncrated 7- 15/32 x 51- 6/32 x 26-3/8  
-Crated 9- 14/32 x 54- 19/32 x 29-31/32  
Outdoor Unit-Uncrated 28-15/16 x 37  
H
x
W
x
D
Heating Maximum 80F DB/67F WB  
Minimum  
-F DB/ - F WB  
x 13-3/8  
-Crated  
32-17/32 x 40  
x 16-12/32  
CERTIFICATION  
WEIGHT  
Net  
INDOOR  
60.0  
OUTDOOR  
157.0  
(lbs.)  
Shipping(lbs.)  
77.0  
170.0  
Shipping Volume (cu.ft.) 8.9  
12.3  
24THS32  
 
Dimensional Data  
Indoor Unit: THS2432  
6-3/32  
3-3/8  
3-15/16  
12-7/32  
11-1/32  
5-3/4  
3-9/32  
5-9/16  
11-1/32  
4-9/16  
Dimension : inch  
Holes in the rear side (View from front)  
Hole for wall-through piping (View from front)  
Drain connection  
Drain connection for left side  
Refrigerant liquid line (1/4") Flare connection  
Refrigerant gas line (3/4") Flare connection  
Hole for rear side refrigerant tubing  
Hole for through-the-wall refrigerant tubing (ø3-15/16" hole)  
Hole for fresh air intake (Knockout hole)  
Hole for right side refrigerant tubing (Knockout hole)  
Hole for left side drain connection (Knockout hole)  
Hole for power supply (Conduit size 1/2")  
Infrared rays receiver for wireless remote controller  
Cutting position for fresh air intake  
5-3/16  
2-25/32  
1-3/8  
48-7/16 (Suspension bolt hole pitch)  
1919_THS_I  
50-13/32  
26-3/8  
10  
10  
Air outlet  
9-7/8  
or more  
or more  
51-3/16  
Front  
8-7/16  
9-7/8  
(Service space)  
(Service space)  
Air intake  
3-1/2  
4-1/16  
5-25/32  
7-7/32  
Outdoor Unit: CH2432  
6-11/16  
26  
4-21/64  
1-31/32  
1-31/32  
37  
Dimension : inch  
Hole for anchor bolt (4-ø1/2)  
Refrigerant tube joint (narrow tube)  
Flare connection 1/4 in (6.35 mm)  
Refrigerant tube joint (wide tube)  
Flare connection 3/4 in (19.05 mm)  
Refrigerant tubing inlet  
Power supply inlet  
1131_THS_I  
WARRANTY  
Full specific warranty rights, conditions, exclusions and obligations are specified in the  
warranty packed with each products.  
SANYO products are warranted against defects in materials and workmanship for the  
period below;  
LABOR  
30 Days  
N/A  
PARTS  
5 Years  
1 Year  
Compressor  
Other Components  
Because of a policy of continuous product improvements, SANYO reserves the right  
to change specifications and design without notice.  
SANYO FISHER COMPANY  
A Division of SANYO North America Corporation  
21605 Plummer St. Chatsworth, CA 91311  
Phone : (818) 998- 7322  
Fax  
: (818) 701- 4160  
 

Radio Shack Motorized Toy Car 60 8506 User Guide
RCA Convection Oven RMW1170 User Guide
Ricoh All in One Printer MP C2030 User Guide
Ricoh Digital Camera K 3 User Guide
Ricoh Printer CL3000 User Guide
Roadmaster Speaker RBB650T User Guide
Samsung Car Stereo System 400UX 2 User Guide
Sanus Systems Indoor Furnishings HTB4 User Guide
SATO Printer CLe RFID User Guide
Sears Saw 113242502 User Guide