INSTRUCTION MANUAL
MPR-411F
MPR-411FR
Pharmaceutical Refrigerator with Freezer
PRECAUTIONS FOR SAFE OPERATION
It is imperative that the user complies with this manual as it contains
important safety advice.
Items and procedures are described so that you can use this unit correctly and safely.
If the precautions advised are followed, this will prevent possible injury to the user and
any other person.
Precautions are illustrated in the following way:
WARNING
Failure to observe WARNING signs could result in a hazard to personnel
possibly resulting in serious injury or death.
CAUTION
Failure to observe CAUTION signs could result in injury to personnel and
damage to the unit and associated property.
Symbol shows;
△
this symbol means caution.
this symbol means an action is prohibited.
this symbol means an instruction must be followed.
●
Be sure to keep this manual in a place accessible to users of this unit.
< Label on the unit >
This mark is labeled on the cover in which the electrical components of high voltage are
enclosed to prevent the electric shock.
The cover should be removed by a qualified engineer or a service personnel only.
2
PRECAUTIONS FOR SAFE OPERATION
WARNING
Do not use the unit outdoors. Current leakage or electric shock may result if the unit is exposed to
rain water.
Only qualified engineers or service personnel should install the unit. The installation by
unqualified personnel may cause electric shock or fire.
Be sure to install the unit on a sturdy floor. If the floor is not strong enough or the installation site
is not adequate, this may result in injury from the unit falling or tipping over.
Never install the unit in a humid place or a place where it is likely to be splashed by water.
Deterioration of the insulation may result which could cause current leakage or electric shock.
Install a leak breaker on the power supply side when you use the unit in humid or wet situations,
as well as installing an earth plate. Consult our shops or an electrician for these installations.
Never install the unit in a flammable or volatile location. This may cause explosion or fire.
Never install the unit where acid or corrosive gases are present as current leakage or electric
shock may result due to corrosion.
Make sure a dedicated power source is used as indicated on the rating label attached to the unit.
Make sure to remove dust from the power supply plug before inserting in a power source.
A
dusty plug or improper insertion may pose a hazard.
Use a power supply outlet with ground (earth) to prevent electric shock. If the power supply
outlet is not grounded, it will be necessary to install a ground by qualified engineers.
Never ground the unit through a gas pipe, water main, telephone line or lightning rod. Such
grounding may cause electric shock in the case of an incomplete circuit.
Do not insert metal objects such as a pin or a wire into any vent, gap or any outlet for inner air
circulation. This may cause electric shock or injury by accidental contact with moving parts.
Never store volatile or flammable substances in this unit. This may cause explosion or fire.
Never store corrosive substances in this unit. This may lead to damage to the inner components
or electric parts.
If this unit is to be used for storing poisons, radioactive material or other harmful products,
ensure that it is in a safe area. Failure to do so may lead to an adverse effect on the health of
personnel in the area and the local environment. In this case, a request for repair or maintenance
will necessitate a safety check sheet for maintenance personnel.
3
PRECAUTIONS FOR SAFE OPERATION
WARNING
Always disconnect the power supply to the unit prior to any repair or maintenance of the unit in
order to prevent electric shock or injury.
Ensure you do not inhale or consume medication or aerosols from around the unit at the time of
maintenance. These may be harmful to your health.
Never splash water directly onto the unit as this may cause electric shock or short circuit.
Never disassemble, repair, or modify the unit yourself. Any such work carried out by an
unauthorized person may result in fire or injury due to a malfunction.
Make the power supply to the unit is disconnected when the lamp is replaced as this will prevent
electric shock.
Disconnect the power supply plug if there is something wrong with the unit. Continued
abnormal operation may cause electric shock or fire.
If the unit is to be stored unused in an unsupervised area for an extended period, ensure that
children do not have access and that doors cannot be closed completely.
The disposal of the unit should be accomplished by appropriate personnel. Always remove
doors to prevent accidents such as suffocation.
Make sure to prepare a safety check sheet when you request any repair or maintenance for the
safety of service personnel.
CAUTION
Select a level and sturdy floor for installation. This precaution will prevent the unit from tipping.
Improper installation may result in water spillage or injury from the unit tipping over.
Connect the unit to a power source as indicated on the rating label attached to the unit. Use
of any other voltage or frequency other than that on the rating label may cause fire or electric shock.
Fix the shelves securely. Incomplete installation may cause injury or damage.
When removing the plug from the power supply outlet, grip the power supply plug, not the cord.
Pulling the cord may result in electric shock or fire by short circuit.
4
PRECAUTIONS FOR SAFE OPERATION
CAUTION
Never damage or break the power supply plug or cord. Do not use the supply plug if its cord
is loose. This may cause fire or electric shock.
Do not touch any electrical parts such as the power supply plug or any switches with a wet hand.
This may cause electric shock.
Do not climb onto the unit or do not put articles on the unit. This may cause injury by tipping or
damage to the unit.
Do not store bottle or cans in the freezer. This may cause injury by broken of containers due to
the frozen.
Do not touch any stock (especially metal objects) in the freezer with a wet hand. This may
cause frostbite.
Always hold the handle when closing the door. This will reduce the likelihood of a trapped finger.
Never lean or press on the glass. Intentional force may cause injury if the glass breaks.
Do not lean on the door. This may cause injury if the unit tips over.
Always disconnect the power supply plug before moving the unit. Take care not to damage the
power cord. A damaged cord may cause electric shock or fire.
Dispose of water in the evaporation tray completely prior to the movement. Spilled water or
splashed water may cause current leakage or electric shock.
Be careful not to tip over the unit during movement to prevent damage or injury.
Always disconnect the power plug when the unit is not used for long periods.
Do not put the packing plastic bag within reach of children as suffocation may result
5
CAUTIONS FOR USAGE
1. If the unit is unplugged or the power to the unit is interrupted, do not restart the unit for at least 5
minutes. This protects the compressor.
2. This inner cabinet is refrigerated by the forced circulation of cooled air inside the chamber. Ensure
that the intake and exhaust vents are not blocked. Adequate space should be provided between the
items inside the unit to allow air circulation.
3. Never store corrosive materials such as acid or alkali unless the container is completely sealed up.
Corrosion may lead to failure of the unit in time.
4. If the ambient temperature is fairly high, the alarm lamp is flashed, the buzzer sounds, and the
temperature display is flashed at the time of initial start up. The alarm is canceled automatically when
the chamber temperature is decreased.
5. Once the chamber temperature has stabilized, put the items into the chamber in small batches to
minimize the temperature increase.
6. Fix the shelves securely. Place items on the shelves and leave a space between the walls of the
cabinet and the contents to allow air circulation. Do not place items on the floor of the chamber.
7. Always close the door firmly. The door check lamp is lit when the door is open. The alarm buzzer
sounds two minutes after door opening. The buzzer can be canceled automatically when the door is
closed.
8. Always open and close the door gently. Rough operation may lead fall down of stocked items,
incomplete closing, or damage of door gasket.
9. The cooling pipe is routed in the rear of the freezer. Never use a knife or a screw driver, etc. to
remove the frost. They may cause damage of chamber wall or improper operation of the unit.
10. Do not drop any heavy items or sharp edge materials onto the freezer floor.
11. Move the freezer switch to OFF position when the freezer is not used or at the time of defrosting of
freezer. In the OFF condition, the freezer is not cooled down at all.
12. If an instrument requiring a power source is to be placed inside the cabinet, the cable can be lead
through the access port on the left hand side of the cabinet. After installation, a rubber cap should be
used to seal the access port. Failure to do this can affect the temperature uniformity inside the cabinet
and lead to condensation on the outside of the access port.
13. Do not clean the unit with scrubbing brushes, acid, thinner, solvents powdered soap, cleanser or hot
water. These agents can scratch the paint or cause it to peel. Plastic and rubber parts can be easily
damaged by these materials, especially solvents. When a neutral detergent is used to clean the unit,
wipe it up thoroughly with a cloth soaked in clean water.
14. If condensation forms on the front glass or frame surface, wipe it off with a dry soft cloth.
6
CAUTIONS FOR USAGE
Model with CE mark
This unit is equipped with a circuit breaker on the back. Make sure this breaker is switched ON before
the unit starts to run.
When the operation of the unit is stopped by this breaker, contact with dealer or service station after
disconnected the power supply plug.
Circuit breaker
ENVIRONMENTAL CONDITIONS
This equipment is designed to be safe at least under the following conditions (based on the IEC 1010-1):
1. Indoor use;
2. Altitude up to 2000 m;
3. Ambient temperature 5oC to 40oC
4. Maximum relative humidity 80% for temperature up to 31oC decreasing linearly to 50% relative
humidity at 40oC;
5. Mains supply voltage fluctuations not to exceed ±10% of the nominal voltage;
6. Other supply voltage fluctuations as stated by the manufacturer;
7. Transient overvoltages according to Installation Categories (Overvoltage Categories) II; For mains
supply the minimum and normal category is II;
8. Pollution degree 2 in accordance with IEC 664.
7
NAME AND FUNCTION OF PARTS
3
11
4
6
7
5
1
2
8
8
9
Refrigerator
Freezer
9
4
10
1. Glass window: Water can sometimes condense on the glass in areas of high humidity. Wipe off
the condensation with a dry soft cloth.
2. Magnetic door gasket: Always keep clean.
3. Control panel: The panel is divided into two portion; Upper portion is an indicator and lower is a
controller. Press upper right corner to open the lower cover. Temperature setting is available through
this panel. Refer to page 9 for the details.
4. Mounting space for temperature recorder: Space for an automatic temperature recorder available
separately. See page 17.
5. Lamp: This lamp lights up when the refrigerator door is open.
6. Air intake vent: Ensure this vent is never blocked. Failure to do so will result in unstable
temperature distribution.
7. Circulating fan: Fan is installed inside the enclosure. Do not insert anything into the enclosure.
The air exhaust vent is located at the upper of the fan.
8. Lock: Turn key clockwise through 180o to lock the door.
9. Access port (rear): This hole allows cables to be passed into the cabinet.
10. Leveling feet: Use this screw/bolt to adjust the height and level the unit.
11. Remote alarm terminal (rear): This terminal is used to alarm an abnormal status at a remote
location. See page 18 for the details.
8
NAME AND FUNCTION OF PARTS
Control panel
11
10
9
7
6
12
1
2
8
3
4
5
1. Alarm buzzer stop key (BZ): Press this key to silence the buzzer in the event that the alarm
operates and buzzer sounds.
2. Display select key (REF./FREEZ.): By pressing this key, internal temperature display of refrigerator
or freezer and each setting is selected.
3. Set key (SET): Pressing this key activates temperature set mode. The digit which can be set is
flashed. By pressing the key again after setting, the set value is accepted.
4. Digit shift key (
): Pressing this key in set mode causes the changeable digits to move. Key lock
is activated by pressing this key for more than 5 seconds in the temperature display mode. See “Key
lock operation” on page 13.
5. Numerical value shift key (
): Pressing this key in the setting mode causes the numerical value to
change. “ON-OFF” of key lock can be selected by pressing this key in the key lock mode.
6. Temperature display: This indicator shows the chamber temperature or set temperature.
7. Refrigerator indicator (REFRIGERATOR): This indicator is lit when the refrigerator is selected.
8. Freezer indicator (FREEZER): This indicator is lit when the freezer is selected.
9. Alarm lamp (ALARM): This lamp is flashed during alarm condition.
10. Door check lamp (DOOR): This lamp is lit when the door is open.
11. Freezer lamp (FREEZER): This lamp is lit during freezer operation.
12. Freezer switch: Turn this switch “OFF” when the freezer is to be defrosted or is not to be used.
Note: When the freezer switch is OFF, the freezer chamber is not refrigerated at all.
9
BEFORE COMMENCING OPERATION
Installation site
To operate this unit properly and to obtain maximum performance, install the unit in a location with the
following conditions:
1. A location not subjected to direct sunlight
Installation in a location subjected to direct sunlight may lead to inadequate cooling.
2. A location with adequate ventilation
Leave at least 10cm around the unit for ventilation. Poor ventilation will result in a reduction of the
refrigeration capacity.
3. A location away from heat generating sources
Avoid installing the unit near heat-emitting appliances such as gas ranges or stoves. Heat can cause
inefficient refrigeration.
4. A location with a sturdy and level floor
Install the unit on a sturdy floor to avoid vibration and noise. Placing the unit on an unsteady floor may
cause vibration and noise.
WARNING
Be sure to install the unit on a sturdy floor. If the floor is not strong enough or the installation site is
not adequate, this may result in injury from the unit falling or tipping over.
CAUTION
Select a level and sturdy floor for installation. This precaution will prevent the unit from tipping.
Improper installation may result in water spillage or injury from the unit tipping over.
5. A location not prone to high humidity
WARNING
Do not use the unit outdoors. Current leakage or electric shock may result if the unit is exposed to
rain water.
Never install the unit in a humid place or a place where it is likely to be splashed by water.
Deterioration of the insulation may result which could cause current leakage or electric shock.
Do not install the unit under water pipes or steam pipes. Deterioration of the insulation may result
which could cause current leakage or electric shock.
6. A location without a flammable or corrosive gas
Avoid placing the unit where chemicals are stored or gases are produced. Also avoid areas where there
is a great deal of dust.
WARNING
Never install the unit in a flammable or volatile location. This may cause explosion or fire.
Never install the unit where acid or corrosive gases are present as current leakage or electric shock
may result due to corrosion.
7. A location not subjected to strong electromagnet interference
10
BEFORE COMMENCING OPERATION
Installation
1. Remove the packaging materials and tapes
Remove all transportation packaging materials and
tapes. Open the doors and ventilate the unit. If the
outside panels are dirty, clean them with a neutral
detergent and wipe it up with a wet cloth.
2. Adjust the leveling foot
Leveling feet
Extend the leveling feet by rotating them
counterclockwise to contact them to the floor.
Ensure the unit is level.
3. Fix the unit
Two fixtures are attached to the rear of the frame. Fix
the frame to the wall with these fixtures and rope or
chain.
Hook
4. Ground (earth)
WARNING
Use a power supply outlet with ground (earth) to prevent electric shock. If the power supply outlet is
not grounded, it is necessary to install a ground by qualified engineers.
Never ground the unit through a gas pipe, water main, telephone line or lightning rod. Such
grounding may cause electric shock in the case of an incomplete circuit.
START-UP OF UNIT
The following procedures should be adhered to for initial start-up and continuous operation.
1. Connect unit to dedicated power supply. Do not put any product in the unit at this time.
2. On start-up, the alarm buzzer sometimes operates. In this case, stop the buzzer by pressing the
alarm buzzer stop key (BZ).
3. Set the desired temperature.
4. Confirm that the chamber temperature is at the desired temperature.
5. When you are satisfied that the unit is working correctly, begin slowly placing product into the chamber
to minimize the temperature rise.
11
OPERATING INSTRUCTIONS
Control panel
1. Setup of chamber temperature
Table 1 shows the basic operation method. Perform key operation in the sequence indicated in the table.
The example in the table is based on the assumption that the refrigerator temperature is 4oC and the
freezer temperature is -25oC.
Note: The unit is set at the factory so that the refrigerator temperature is 5oC and the freezer
temperature is -20oC.
Table 1 Basic operation procedure (Example of setting: refrigerator; 4oC, freezer; -25oC)
Operation
Key operated
-----
Indication after operation
The current refrigerator or
freezer temperature is displayed.
The refrigerator indicator lights and the
current refrigerator
Display mode
Refrigerator
temperature
1
2
Connect the power supply plug
to the power outlet
By pressing the display select
key, select the refrigerator
REF.
FREEZ.
temperature is displayed.
3
4
Press the set key
The second digit of the temperature
display flashes.
Refrigerator
temperature
setup mode
SET
SET
Set the temperature to 04 with
the digit shift key and the
numerical value shift key
Pressing the key shifts the digit
Which can be set.
Pressing the key shifts up the figure of
the current digit.
5
6
7
8
Press the set key
The value is stored in memory and the
current refrigerator temperature is
displayed.
By pressing the display select
key, select the freezer
The freezer indicator lights
and the current freezer
REF.
FREEZ.
temperature is displayed.
The second digit of the temperature
display flashes.
Press the set key
Freezer
temperature
setup mode
SET
Set the temperature to -25 with
the digit shift key and the
numerical value shift key
Pressing the key shifts the digit which
can be set.
Pressing the key shifts up the
figure of the current digit.
The value is stored in memory and the
current freezer temperature is
displayed.
9
Press the set key
SET
Note:
If no key has been pressed for about 90 seconds in the temperature setup mode, the display mode returns
automatically to the current chamber display mode. In this case, the chamber temperature setting is not
changed.
The freezer temperature can be set in the range between -10 and -35℃. Remember that the guaranteed
temperature with no load at an ambient temperature of 30℃ is -30℃.
12
OPERATING INSTRUCTIONS
2. Key lock operation
This unit incorporates a key lock feature which can inhibit the tampering using the keys on the control
panel.
The key lock is set to OFF at the factory.
Display
Mode
Key lock OFF
Key lock ON
Function
Temperature change enabled
Temperature change disabled
Table 2 Key lock setup procedure (Example: Key lock OFF ⇒ Key lock ON)
Operation
Key operated
-----
Indication after operation
The current refrigerator or freezer
temperature is displayed.
The lower digit of the temperature
display blinks.
Display mode
Temperature
display mode
Key lock
1
2
3
Press and hold the digit shift
key for about 5 seconds
Set the lower digit to “1” with
the numeric value shift key
Press the set key
mode
Pressing the key shifts up the
figure of the digit.
Key lock is set to ON and the current
refrigerator or freezer temperature is
displayed.
Temperature
display mode
SET
Note:
Key lock can be set any time when the current refrigerator or freezer temperature is displayed.
If the numerical value shift key is held depressed for more than about 5 seconds, F0 is displayed. This
is one of the functions used by the service personnel and the figure should not be changed. To return to
the refrigerator or freezer temperature display mode, press the set key or leave the unit for about 90
seconds without pressing any key.
13
OPERATING INSTRUCTIONS
Alarm and safety functions
This unit has the alarm and safety functions shown in Table 3, and also a self diagnostic function.
Kind of alarm
or safety
High
temperature
alarm
Situation
Indication
Buzzer
Safety operation
Refrigerator
Alarm lamp flashes.
All digits on the temperature
display flash.
Intermittent tone
after a delay of 15 activated after a
minutes.
Remote alarm is
・
If the chamber temperature
deviates from the set
delay of 15
minutes.
temperature +5oC or more.
Freezer
・
If the chamber temperature
deviates from the set
temperature +10oC or more.
Low
temperature
alarm
Refrigerator
Intermittent tone
Intermittent tone
Remote alarm is
activated.
・
If the chamber temperature
drops to 0oC or lower.
Freezer
Remote alarm is
・
If the chamber temperature
deviates from the set
temperature -10oC or lower.
In the event of a power
failure or disconnection of
power supply plug from the
outlet
after a delay of 15 activated after a
minutes.
-----
delay of 15
minutes.
Power failure
alarm
-----
Remote alarm is
activated.
Door alarm
Auto return
When the door is opened
Door check lamp is lit.
Intermittent tone
after a delay of 2
minutes.
-----
If a key operation is not
performed for about 90
seconds in each setting
mode.
Chamber temperature is
displayed.
-----
Setting mode is
canceled.
Key lock
When the key lock is ON
(L1).
-----
-----
Key input is
disabled.
Thermal
sensor
abnormality
If the thermal sensor of
refrigerator goes open or
short circuit.
Alarm lamp flashes.
Intermittent tone
Remote alarm is
activated.
Operation by the
defrost sensor.
Remote alarm is
activated.
Freezer will run
continuously .
Remote alarm is
activated.
E1 and chamber temperature
are displayed alternately on the
temperature display.
If the freezer sensor of
refrigerator goes open or
short circuit.
Alarm lamp flashes.
E2 and chamber temperature
are displayed alternately on the
temperature display.
If the defrost sensor goes
open or short circuit.
Alarm lamp flashes.
E3 and chamber temperature
are displayed alternately on the
temperature display.
Continuous
running.
Over-heat
protector
Refrigerator
-----
-----
Heater and fan
motor OFF.
・
If the chamber temperature
Is higher than 28oC.
Note: The remote alarm can be canceled by pressing the alarm buzzer stop key (BZ) as it is activated in
conjunction with the buzzer (except power failure alarm).
When more than two alarm condition occur simultaneously, the lowest number error code has priority on the
error display.
After a power failure, the unit will resume operation with the set value that was in place before power failure
occurred.
14
OPERATING INSTRUCTIONS
Defrost cycles
Refrigerator
There is no need for routine defrosting of the unit as this occurs automatically as follows:
1. Cycle defrost
To keep the temperature stable inside the chamber, the refrigeration compressor is cycled on and off.
During “off” periods any frost which has accumulated on the refrigeration coils is melted by energizing a
small heater. This will not have any discernible effect on the chamber temperature.
2. Forced defrost
When the set temperature is low, ambient humidity is high, or a large amount of damp product is being
stored inside the refrigerator, there is a possibility that cycle defrost may not be enough to remove all of
the frost on the refrigeration coils. In this case, a forced defrost cycle can be initiated.
When the unit is operating under a forced defrost cycle, the current chamber temperature and “dF” is
displayed alternately on the digital temperature display.
Once the forced defrost cycle is complete, normal operation resumes. The chamber temperature rises
to about 10oC during the forced defrost cycle.
Freezer
When the frost is built-up on the freezer wall, defrost the freezer by the following procedure as the freezer
has no automatic defrosting function.
1. Temporarily move all the contents of the freezer to another freezer.
2. Turn the freezer switch to “OFF”.
3. When the frost on the wall has been eliminated, remove the water and wipe the inside of the freezer
completely.
4. Turn the freezer switch to “ON”.
5. Once the chamber temperature has resumed normal set-point temperature, place the original contents
back in the freezer.
Note: The freezer does not automatically reset to normal operation.
15
TEMPERATURE RECORDER
Automatic temperature recorder
To record the chamber temperature, an optional automatic temperature recorder is available. Please
consult with our sales department or agency for recorder installation.
For the proper usage of temperature recorder, refer to an instruction manual included with the recorder.
The available recorder and a dedicated fixture is as follows:
Temperature recorder:
Model MTR-0620LH (for refrigerator)
Model MTR-4014LH (for freezer)
Fixture: MDF-53RO (H)
Temperature recorder for refrigerator
Capillary tube
(MTR-0620LH)
Rear
Front
Sensor
Access port (black cap)
Right side of refrigerator
Front
Rear
Sensor
Left side of freezer
Fixture of recorder (Option)
(MDF-53RO (H))
Temperature recorder for freezer
(MTR-4014LH)
16
TEMPERATURE RECORDER
Attachment of temperature recorder
For refrigerator
Fig. 1
1. Attach the fixture to the temperature recorder with
two screws. (Fig. 1)
Fig. 2
2. Remove the screws at the right corner on the top of
the unit and fix the recorder to the position. (Fig. 2)
3. Remove a rubber cap and insulation covering the
access hole on the back of the unit.
4. Take the recorder sensor into the refrigerator
Fig. 3
chamber through the access hole.
5. Fix the recorder sensor on the right wall of the
chamber with the enclosed clips (large). (Fig. 3)
6. Make a cut on the rubber cap and route the lead wire
Fig. 4
through it. (Fig. 4)
7. Cover the access port with the insulation and rubber
cap.
For freezer
1. Remove a cap for the fixing screw on the cover for
Fig. 5
mounting space of temperature recorder.
Fig. 6
2. Remove the fixing screw and open the panel. (Fig.
5)
3. Remove the panel by pushing the shaft on both side
outward and remove the panel fixture.
4. Attach the temperature recorder (MTR-4014LH) to
the recorder fixture [MDF-53RO (H)] by using the
enclosed screws. (Fig. 6)
5. Remove a rubber cap and insulation covering the
Fig. 7
access port on the back of the unit.
6. Take out the recorder sensor from the back of the
unit through the mounting space.
Fig. 8
7. Pass the sensor through the access port of the
freezer. The length of the capillary inside the freezer
should be about 40 cm.
8. Fix the recorder sensor on the left wall of the
chamber with the enclosed clips (small). (Fig. 7)
9. Make a cut on the rubber cap and route the lead wire
Fig. 9
through it. (Fig. 4 above)
10. Cover the access port with the insulation and rubber
cap.
11. Fix the extra capillary tube to the back of the
recorder with the enclosed clip and screw. (Fig. 8)
12. Mount the recorder fixture to the mounting space in
the unit. (Fig. 9)
17
REMOTE ALARM TERMINAL
WARING
Always disconnect the power supply to the unit before connection of alarm equipment to remote
alarm terminals to prevent electric shock or injury.
The terminal of the remote alarm is installed in the terminal cover at rear of the cabinet. The maximum
contact rating is DC 30 V, 2 A.
Output: normal “open”
abnormal “close”
Note:
The alarm is silenced by the alarm buzzer stop key (BZ)
since the remote alarm is operated in conjunction with
alarm buzzer. The alarm is activated when the power
supply plug is disconnected. In this case, the alarm
Terminal cover
buzzer cannot be canceled with the alarm buzzer stop
key (BZ).
Connection of remote alarm terminal
1. Remove the terminal cover at rear of the cabinet.
2. Connect the lead wire of alarm equipment to the terminal.
3. Replace the terminal cover.
MAINTENANCE
WARNING
Always disconnect the power supply to the unit prior to any repair or maintenance of the unit in
order to prevent electric shock or injury.
Ensure you do not inhale or consume medication or aerosols from around the unit at the time of
maintenance. These may be harmful to your health.
Cleaning
1. Clean the unit once a month. Regular cleaning keeps the unit looking new.
2. Use a dry cloth to wipe off small amounts of dirt on the outside and inside of the unit and all
accessories. If the unit is very dirty, use a neutral detergent.
3. After cleaning, wipe away the cleaner completely with a cloth washed in clean water.
4. Never pour water onto or into the unit. Doing so can damage the electrical insulation and may cause
electric shock or short circuit.
5. The compressor and other mechanical part are completely sealed. This unit requires absolutely no
lubrication.
18
TROUBLE SHOOTING
If the unit malfunctions, check out the following before calling for service.
If nothing operates even when plug in
1. The unit is not connected to the power supply or capacity of power source enough.
2. There is a power failure.
3. The fuse is blown or the circuit breaker is activated.
When the unit does not accept changes of set-point temperature
1. The key lock is “OFF”?
When alarm is activated
On start-up
1. The temperature in the unit does not match set value.
In use
1. The door was kept opened for long time.
2. The set value was changed.
3. The containers of high temperature (load) were put in the unit.
In these cases, alarm is removed automatically by running the unit for several hours.
When the unit does not get cold enough
1. The air exhaust vent is blocked by refrigerator contents.
2. A large amount of warm product was put in the unit.
3. There is any heat sources in the unit.
4. The door is opened frequently.
5. The ambient temperature is too high.
6. The unit is in direct sunlight.
7. The door is not securely closed.
8. The door seal is damaged or foreign substance inserted between the door gaskets.
DISPOSAL OF UNIT
WARNING
If the unit is to be stored unused in an unsupervised area for an extended period ensure that children
do not have access and doors cannot be closed completely.
The disposal of the unit should be accomplished by appropriate personnel. Always remove
doors to prevent accidents such as suffocation.
19
SPECIFICATIONS
Name
Model
Pharmaceutical Refrigerator with Freezer
MPR-411F/MPR-411FR
Refrigerator
Freezer
External dimensions
Internal dimensions
Effective capacity
Exterior
W800 x D600 x H1805 (mm)
W720 x D495x H1425 (mm)
W317 x D440x H576 (mm)
82 L
340 L
Acrylic finish baked on zinc galvanized steel
Interior
Acrylic finish baked on zinc galvanized steel
Painted aluminum plate
Door
Acrylic finish baked on zinc galvanized steel
Shelf
Polyethylene coated wire
Maximum load; 25 kg/shelf (large size)
Maximum load; 15 kg/shelf (small size)
Stainless rack (MPR-411FR only)
Maximum load; 15 kg/rack
Polyethylene coated wire
Maximum load; 15 kg/shelf
Rack
-----
Access hole
Insulation
Inner diameter 30 mm, Back side
Inner diameter 30 mm, Back side
Rigid polyurethane foamed-in place (CFC-FREE)
Cooling method
Compressor
Condenser
Evaporator
Refrigerant
Defrosting
Forced air circulation
Direct cooling
Hermetic reciprocating type, Output; 160 W Hermetic reciprocating type, Output; 160 W
Wire tube
Rear side condenser
Tube on sheet type
Fin tube type
R-412A (TP5R)
Cycle defrost and forced defrost
Fully automatic
Natural defrost by switch OFF
Temperature controller
Temperature display
Sensor
Microprocessor control system
Digital display
Thermister sensor
Heater
99 W
-----
Alarm & Safety
High temp. alarm, Over-heat protector, Low temp. alarm, Power failure alarm,
Door alarm, Auto-return, Key lock, Thermal sensor abnormality
Contact capacity: DC 30 V, 2 A
Remote alarm contact
Lighting
Incandescent lamp (T22E17)
125V, 10W (AC 110 to 115V)
250V, 15W (AC 220 to 240V)
-----
Accessories
Weight
Key 1set, Nylon clip; large 2 pcs., small 2 pcs.
MPR-411F; 124 Kg, MPR-411FR; 135 Kg
Option
Automatic temperature recorder (for refrigerator MTR-0620LH, for freezer MTR-4014LH)
Mounting kit for temperature recorder [MDF-53RO(H)]
Rack [MPR-41R] (for MPR-411F only)
Note : Design or specifications will be subject to change without notice.
20
PERFORMANCE
Refrigerator
2oC to 14oC
Freezer
Control range
-10oC to -30oC
(Ambient temp.; -5oC to +35oC, No load) (Ambient temp.; -5oC to +35oC, No load)
39 dB (A scale)
Noise level
Maximum pressure
Rated voltage
1705 kPa
AC 115 V
60 Hz
1901 kPa
AC 230 V
50 Hz
AC 110 V
60 Hz
AC 220 V
50 Hz
AC 220 V
60 Hz
AC 240 V
50 Hz
Rated frequency
Power consumption
370 W
370 W
350 W
370 W
350 W
350 W
Note :The unit with CE mark complies with EC directives 89/336/EEC, 93/68/EEC and 73/23/EEC.
21
CAUTION
Please fill in this form before servicing.
Hand over this form to the service engineer to keep for his and your safety.
Safety check sheet
□Yes
□No
1. Refrigerator contents :
Risk of infection:
□Yes
□Yes
□Yes
□No
□No
□No
Risk of toxicity:
Risk from radioactive sources:
(List all potentially hazardous materials that have been stored in this unit.)
Notes :
2. Contamination of the unit
Unit interior
□Yes
□No
No contamination
Decontaminated
Contaminated
Others:
□Yes
□Yes
□Yes
□No
□No
□No
3. Instructions for safe repair/maintenance of the unit
a) The unit is safe to work on
□Yes
□Yes
□No
□No
b) There is some danger (see below)
Procedure to be adhered to in order to reduce safety risk indicated in b) below.
Date :
Signature :
Address, Division :
Telephone :
Product name :
Model :
MPR-411F
MPR-411FR
Serial number :
Date of Installation :
Pharmaceutical
Refrigerator with Freezer
Please decontaminate the unit yourself before calling the service engineer.
22
7FB6P101242002
Recycled paper
SANYO Electric Biomedical Co., Ltd.
5-5, Keihan-Hondori 2-Chome
Moriguchi City, Osaka 570-8677 Japan
Printed in Japan
|