IF-CB/DM
CobraNet Interface Card
Introduction
Names and functions of parts
Thank you very much for purchasing the TASCAM IF-CB/
DM CobraNet™ Interface Card for TASCAM DM-3200
and DM-4800 mixers.
This Interface Card allows a TASCAM DM-3200/DM-4800
to be connected to a CobraNet digital audio network and to
send and receive up to 32 channels (16 inputs/16 outputs)
of uncompressed digital audio signals with a sampling
frequency of 48 kHz.
Before using the unit, please take time to read this manual
thoroughly to ensure you understand how to properly set up
and connect the unit, as well as the operation of its many
useful and convenient functions. After you have finished
reading this manual, please keep it in a safe place for future
reference.
1 SECONDARY (RJ-45 connector): connector for the
secondary cable
2 PRIMARY (RJ-45 connector): connector for the primary
cable
3 Green indicator
Light or blink slowly when a network cable is
connected correctly.
•
You can also download the Owner’s Manual from the
TASCAM web site (http://www.tascam.com).
Blink rapidly when data is being transmitted properly
over the network.
•
After reading this manual, we recommend that you visit
the CobraNet website below before using this card. This
site provides valuable information, including an overview
of CobraNet, explanations of technologies, application
methods, examples of use, and tool downloads.
4 Orange indicator
Blink when functioning as the conductor (clock
master).
•
Light when power is properly supplied.
•
•
Primary and Secondary both blink when an
irregularity occurs on the network.
Features
Transmission of up to 32 channels (16 inputs/16 outputs)
of audio
•
DM-3200/DM-4800 software
version
In order to use the IF-CB/DM card, the DM-4800/DM-3200
must use software version 1.70 or later. The mixer cannot
recognize the IF-CB/DM card when using earlier versions.
the latest DM-4800/DM-3200 software and download the
TFI update file.
Compatible with 24 bit quantization and 48 kHz
sampling frequency
•
Trademarks
TASCAM is a trademark of TEAC Corporation,
registered in the U.S. and other countries.
•
Microsoft and Windows are either registered trademarks
or trademarks of Microsoft Corporation in the United
States and/or other countries.
•
Install TMCompanion, which is included on the CD-ROM
included with the DM-4800/DM-3200, on the computer
that you are using. Launch TMCompanion and use the TFI
update file to upgrade the software version used by the
DM-4800/DM-3200.
CobraNet is a trademark of Cirrus Logic, Inc.
•
•
Other company names, product names and logos in this
document are the trademarks or registered trademarks of
their respective owners.
Installing the IF-CB/DM
Product components
NOTE
The included items are listed below.
DM-3200: Install the IF-CB/DM in mixer slot 1. It will
not function in slot 2.
•
•
•
Take care when opening the package not to damage the
items. Keep the package materials for transportation in the
future.
DM-4800: Install the IF-CB/DM in mixer slot 1 or 3. It
will not function in slot 2 or 4.
Turn the mixer power OFF before beginning
installation.
Please contact the store where you purchased this unit if any
of these items are missing or have been damaged during
transportation.
1
Remove the five screws from the cover panel of the
slot where you want to install the IF-CB/DM card
(slot 1 on a DM-3200, slot 1 or 3 on a DM-4800), and
then remove the panel. (If that slot already contains
a card, remove the card.)
Main unit .........................................................................1
Attachment screws ..........................................................5
Owner’s Manual (this document)....................................1
•
•
•
D01106320A
IF-CB/DM
CobraNet Interface Card
DUAL LINK:
This shows the network connection method.
Prefer Primary (default setting):
•
The Primary network has priority. If the Primary network
connection is lost, the mixer automatically switches to
the Secondary network, and reconnects to the Primary
network when it recovers.
Always Primary
:
•
•
•
Only uses the Primary network.
Always Secondary
:
Only uses the Secondary network.
Auto Switch
:
Input settings (input routing)
Make input settings on the INPUT page of the DM-3200/
DM-4800 ROUTING screen.
Uses the Primary network at start-up. If the Primary
network connection is lost, it switches to the Secondary
network, and continues using the Secondary network
even if the Primary network recovers. If the Secondary
network connection is lost, it switches back to the
Primary network.
NAME:
This shows the name of the installed IF-CB/DM card.
LATENCY:
This shows the current latency setting.
BITS:
This shows the current bit-rate setting.
SYSTEM
ª
DM-3200 INPUT page
This section shows information about the system.
1
2
Use the POD 4 knob to select the input source group.
Input source groups are shown in the SOURCE SE-
LECT list at the lower right of the screen.
F/W VER:
This shows the IF-CB/DM firmware version.
Use the POD 3 knob to select the input source rout-
ing destination layer. Routing destination groups are
shown in the LAYER SELECT list at the upper right
of the screen.
ERRORS:
This shows the number of errors that have occurred.
LOAD:
This shows the network load.
3
4
Use the cursor keys to select the source field, and use
the JOG/DATA dial to select the input source.
After making the selection, press the ENTER key to
confirm it.
DM-3200/4800 settings
Setting the clock
Output settings (output routing)
Make output settings using the OUTPUT SLOT page of the
DM-3200/DM-4800 ROUTING screen.
1
Press the PROJECT key to open the CLOCK
screen where you can set the clock source. (See the
“Clock setting” section of chapter 3 of the DM-3200/
DM-4800 User’s Manual.)
2
Set the Fs MODE to 48k, and in the CLOCK SE-
LECT area, select the SLOT where the IF-CB/DM
card is installed. This enables stable operation even
when switching between conductor and performer.
DM-3200 OUTPUT SLOT page
TASCAM IF-CB/DM
3
IF-CB/DM
CobraNet Interface Card
Installing CobraNet Discovery
1
The latest version of CobraNet Discovery Utility can
be downloaded at the following site.
DM-4800 OUTPUT SLOT page
2
3
Double-click the downloaded file and follow the
instructions shown onscreen to install the software.
1
Use the POD 4 knob to select the output source
group from the SOURCE SELECT at the right of
the screen. Options for each of the outputs in the
output source group selected here are shown the
OUTPUT SELECT section on the left of the screen.
If the .NET Framework has not been installed on
the computer that you are using, during the instal-
lation of the CobraNet Discovery Utility, a screen
recommending the installation of the .NET Frame-
work should appear. Click “Yes” to install the .NET
Framework. After installing the .NET Framework,
restart the computer and run the installer for the
CobraNet Discovery Utility again.
2
3
Use the POD 3 knob to select an IF-CB/DM output
channel group (8 channels) to set in the TERMINAL
SELECT section in the center of the screen.
Use the cursor keys to select an output channel in the
OUTPUT SELECT section, and turn the JOG/DATA
dial to select its output source. Press the ENTER key
to confirm the selection.
Using CobraNet Discovery
To access the CobraNet Discovery User Guide, which
explains how to operate the software, follow these
instructions.
CobraCAD and CobraNet Discovery
CobraCAD is a tool used to design and diagnose network
systems. Using a graphic user interface, you can select
CobraNet-compatible devices and network devices (such as
switching hubs), make connections between devices, set the
sampling frequency, latency, bit-rate and other settings, as
well as simulate network setups in advance.
From the Start menu, choose “All Programs” and follow the
“CobraNet Discovery” arrow to the following menu. Select
“User Guide” to open the CobraNet Discovery User Guide
PDF file.
CobraNet Discovery can be used to list the equipment
on the network, view sampling frequency, latency and
bit-rate settings, as well as routing information, including
transmitter and receiver designations and bundle number
settings.
Specifications
A computer running a Windows OS with the CobraNet
Discovery software installed on it must be a part of a
network in order to create a CobraNet on that network.
DM-4800/DM-3200 requirements
Firmware
ª
DM-3200: Version 1.70 or later
DM-4800: Version 1.70 or later
Note: Use the TMCompanion software to update the firmware of the
DM-3200/DM-4800.
Installing CobraCAD
1
The latest version of CobraCAD can be downloaded
at the following site.
Mixer slot
DM-3200: Use slot 1
DM-4800: Use slot 1 or 3
General
ª
2
Double-click the downloaded file and follow the
instructions shown onscreen to install the software.
Audio inputs: 16
Audio outputs: 16
Quantization bit rate: 16-bit, 20-bit, 24-bit
Sampling frequency: 48 kHz
Using CobraCAD
Select Help from the CobraCAD Help menu to open the
Help screen. Refer to this for information about how to
operate the software.
PRIMARY and SECONDARY connectors: RJ-45
Compatible cables: Category 5 or higher (straight, shielded, twisted pair)
Maximum cable length: 100 m (when using a Category 5 cable)
External dimensions: 164 (w) x 40 (h) x 221 (d) mm
Weight: 0.3 kg
TEAC CORPORATION
Phone: +81-42-356-9143
1-47 Ochiai, Tama-shi, Tokyo 206-8530, Japan
Printed in China
|