Videx Door VX800N 2 User Manual

GENERALDIRECTIONS FOR INSTALLATION  
Art.VX800N  
Installation Instructions  
In order to achieve the best results from the schematics described it is necessary to  
install only original VIDEX equipment, strictly keeping to the items indicated on each  
schematic and follow these General Directions for Installation:  
MODELS:  
!
The system must be installed according to national rules in force, in any case the  
running of cables of any intercom unit must be carried out separately from the  
mains;  
VX800N-2  
VX800N-2L  
VX800N/F  
VX800N/S  
VX800N-3  
VX800N-3L  
Module 2 Relay  
Module 2 Relay plus panel illumination  
Stand alone unit 2 Relay. Flush mounting  
Stand alone unit 2 Relay. Surface mounting  
3 Relay  
!
All multipair cables should be compliant to CW1308 specification (0.5mm twisted  
pair telephone cable.  
!
!
Cables for speech line and service should have a max resistance of 10W  
Lock release wires should be doubled up (Lock release wires and power supply  
wires should have a max resistance of 3W);  
3 Relay plus panel illumination  
!
The cable sizes above can be used for distances up to 50m. On distances above  
50m the cable sizes should be increased to keep the overall resistance of the  
cable below the RESISTANCES indicated above;  
FEATURES  
- Access control system with 2 codes and 2 Relay outputs (3 codes, 3  
relays on VX800N-3.. version).  
- Engineer’s code to enter into the “Programming Menu” ( from 4 to 8  
digits).  
!
!
Double check the connections before power up;  
Power up the system then check all functions.  
LOCK RELEASE BACK EMF PROTECTION  
- Programming of the activation time of each relay from 1 up to 99 seconds  
or latching.  
- Possibility to activate relay 1 by shorting terminal ”SW1” to GND and  
relay 2 by shorting terminal “SW2” to GND. Both relays will operate for  
the programmed time ( this feature is not available on VX800N-3  
version).  
A capacitor must be fitted across the terminals on AC lock release (Fig.1A) and a  
diode must be fitted across the terminals on a DC lock release (Fig.1B) to suppress  
back EMF voltages.  
Connect the components to the lock releases as shown in figures.  
- Keypad gives an acoustic (buzzer) signal during the entering of codes  
and a continuous melody for 4 or more seconds, according to the  
number of mistakes (self protection).  
- Keypad includes panel illumination (VX800N-..L only) and 2 LED’s to  
show the following:  
· Correct relay code (green LED on for 2 seconds).  
· Red LED to indicate when in the “programming menu”.  
- Contacts of the relays are available ( N.O and N.C) with 5A max  
24Vac/dc.  
Fig.1A  
Fig.1B  
BUZZER BACK EMF  
When using intercoms with buzzer call (Art.924/926, SMART1/2, 3101/2, 3001/2 and  
3021/2) add one 0,1uF capacitor between terminals 6 and 3.  
- Power requirements: 12/24VAC/DC, 2VA.  
- Working temperature: -10 +50°C  
If help is required for installing or operating this unit please contact our  
technical department on +39 0734 631669 (all countries) or +44 0191 224 3174  
(UK).  
OPERATION  
Factory - Office  
To use the system, type in the programmed code and press “ENTER” , the  
green LED will illuminate and the relay will operate for the programmed  
time.To cancel remain open time, type in the same code and press  
“CLEAR”. If a wrong code is entered, a continuous melody will sound for 4  
or more seconds, according to the number of mistakes.  
VIDEX ELECTRONICS S.p.A. Via del lavoro,1 63020 MONTEGIBERTO (AP) - ITALY  
Phone: (+39) 0734 - 631669 Fax: (+39) 0734 - 632475 www.videx.it e-mail: [email protected]  
Northern UK Office  
VIDEX LTD Unit 4-7 Chillingam Industrial Estate Chapman Street NEWCASTLE UPON TYNE  
Ne6 2XX  
Phone: (+44) 0870 3001240 Fax: (+44) 0191 - 2241559 www.videx-security.com  
INITIALIZATION  
PROGRAMMING(refer also to flow chart)  
When the installation is concluded and carried out according to the wiring  
diagram, power up the system and program it by following the “VX800  
PROGRAMMING” Flow Chart.  
> Enter “ENGINEER’S CODE”: first time type six times “1” (111111 factory  
preset) and press ENTER (The red LED will illuminate).  
> Confirm “ENGINEER’S CODE” (typing again the same) or type the new  
code (4 to 8 digits) then press ENTER (Melody). Pressing twice the  
ENTER button without changing the “ENGINEER’S CODE”, will exit  
from the programming.  
> Enter the code (4 to 8 digits) to enable “RELAY 1” (ACCESS 1) or re-  
enter the existing code then press ENTER (Melody).  
> Enter the “RELAY 1” operation time (2 digits 01 to 99 I.E. 05=5 seconds,  
00= remain open time) or re-enter the existing time then press ENTER  
(Melody).  
> Enter the code (4 to 8 digits) to enable “RELAY 2” (ACCESS 2) or re-  
enter the existing code then press ENTER (Melody).  
> Enter the “RELAY 2” operation time (2 digits 01 to 99 I.E. 05=5 seconds,  
00= remain open time) or re-enter the existing time then press ENTER  
(Melody).  
> Enter the code (4 to 8 digits) to enable “RELAY 3” (ACCESS 3 only for 3  
relay models) or re-enter the existing code then press ENTER (Melody).  
> Enter the “RELAY 3” (only for 3 relay models) operation time (2 digits 01  
to 99 I.E. 05=5 seconds, 00= remain open time) or re-enter the existing  
time then press ENTER (Melody).  
FIRST TIME SIX TIMES  
“111111” FACTORY  
ENTER  
“ENGINEER’S CODE”  
1
PRESET  
Press Enter  
(Red LED will be  
ON)  
TYPE AGAIN SIX TIMES “1” OR  
THE NEW ENGINEER’S CODE  
4TO 8 DIGITS  
CONFIRM OR CHANGE  
“ENGINEER’S CODE”  
Press Enter  
(Melody)  
CODE TO ENABLE  
RELAY1  
4TO 8 DIGITS  
ENTER  
“ACCESS 1 CODE”  
Press Enter  
(Melody)  
TWO DIGITS (01TO 99)  
I.E. 05=5 SECONDS  
00= REMAIN OPEN  
ENTER  
“ACCESS 1 TIME”  
Press Enter  
(Melody)  
CODE TO ENABLE  
RELAY2  
4TO 8 DIGITS  
ENTER  
“ACCESS 2 CODE”  
> The system is ready to use (the red LED will be off).  
INSTRUCTION TO RETURN SYSTEM TO PRESET ENGINEER’S  
FACTORYCODE  
Press Enter  
(Melody)  
> Turn off power to code lock.  
> Keep “ENTER” button pressed while turning back on the power to the  
code lock.  
> Release “ENTER” button.  
> The master code is now set at factory engineer’s code “111111” (six times  
“1”).  
> Proceed with programming for a new system.  
ENTER  
“ACCESS 2 TIME”  
TWO DIGITS (01TO 99)  
ONLY800-3 VERSION  
ONLY800-3 VERSION  
RED LED WILLBE OFF  
Press Enter  
(Melody)  
ENTER  
“ACCESS 3 CODE”  
Press Enter  
(Melody)  
NOTES  
> To switch off any relay while operating, type in the relevant code then  
press the “CLEAR” button.  
> To operate relays together, set the same code for each relay.  
> If a wrong code is entered, the system will lock out for 5 seconds which  
will increase each time a wrong code is entered. The system will operate  
only when the correct code is entered.  
ENTER  
“ACCESS 3 TIME”  
Press Enter  
(Melody)  
SYSTEM READY TO  
USE  
 

Teac CD Player Compact Disc Player User Manual
Toshiba Cash Register FDS 50 User Manual
Toshiba TV DVD Combo MD20P1 User Manual
Transition Networks Network Card CPSMC0800 100 User Manual
Triarch Indoor Furnishings 25312 User Manual
Tripp Lite Network Cables F005 006 User Manual
Tyco Electronics Car Video System 1937L User Manual
ViewSonic Mouse MC204 User Manual
VTech Telephone VT DS6121 User Manual
Weed Eater Lawn Mower 168303 User Manual