JOBAID
PRICING AND AVAILABILITY 800.827.0807
TECHNICAL SUPPORT 800.726.8663
RETURN FOR REPAIR 256.963.8722
TRI-C DP / D4
61102182L1-22A
0105
LOGIC BANTAM JACKS
STATUS LEDs
TRI-C DP / D4
I
Used to perform upstream and downstream testing with a DS0 level tester such
as a TPI 108/109 or Fireberd 4000/6000.
LP
G
OFF
TRI loop sync has been established and no Near End Block Errors
(NEBE) are being received from the loop interface
CLEI: D4D3MU0D_ _
Rx (OUT) – transmits signal out to unit being tested
Tx (IN) – receives signal in from unit being tested
G
G
✷
RED
TRI-interface is out of sync or there is loss of signal
-5
YELLOW
Indicates a BER of 10 has been detected
TRI-C DP
FLASHING Flashes upon receipt of a Near End Block Error (NEBE) or when a
1102182L1
HARDWARE SWITCHES SW1 & SW2
-6
BER > 10 is detected during Local Performance Monitoring
LPBK
CRTX
LPTX
NT1
SW1-1: TRM – along with SW1-2, selects the bank type for the U-BR1TE IV
SW1-2: TRM
CR
G
OFF
Carrier sync (framing per TR-TSY-000397) has been established
and no Near End Block Errors are being received frrom the carrier
interface
AD6
AD5
AD4
AD1
Bank
Count/Slot
SW1-1
On
On
On
Off
SW1-2
Off
On
On
Off
AD3
B1
AD2
TEST
B2
G
G
✷
RED
No framing pattern is being received
LP
D4
D4 Counting
YELLOW
A BER > 10-5 has been detected
D1D Counting
CU in slots 1,4,7,10
CU in slots 2,5,8,11
D4 Counting
CR
ACT
FLASHING Flashes upon receipt of a Near End Block Error (NEBE) or when a
BER > 10-6 is detected during Local Performance Monitoring
SLC I
TEST
ERR
ACT
G
G
GREEN
GREEN
YELLOW
Layer 1 from the ISDN switch to the customer ISDN terminal
equipment has been established
SLC III
On
Off
On
On
NORM
PTRN
D1D Counting
TEST
Unit is in Local Performance Monitoring mode or the local test
pattern gen/det in invoked
SW1-3: B1 –along with SW4 and SW5, selects the service level
SW1-4: B2
SW1-5: D
OUT
(Rx)
L
O
G
I
G
✷
Front panel test has been successssfully initiated or unit is
responding to a 2B+D loopback request
FLASHING Flashes once every two seconds when responding to a B1 loopback
request or when forced into a B1 loopback from the front panel.
Flashes twice every two seconds when responding to a B2 loopback
request or when forced into a B2 loopback from the front panel.
IN
(Tx)
C
Service Option
SW1-3
SW1-4
SW1-5
(B1)
On
On
On
Off
On
Off
Off
(B2)
On
On
Off
On
Off
On
Off
(D)
On
Off
On
On
Off
Off
On
2B+D
2B
B1+D
B2+D
B1
ERR
✷
FLASHING Errors detected by local test pattern detector
FACEPLATE SWITCHES
Rotary Switch - used to select circuit elements for loopback testing
B2
D
I
I
I
I
I
I
I
I
I
I
AD1 – selects address of local unit for loopback
AD2 – selects address of next unit downstream for loopback
AD3 – selects address of second unit downstream for loopback
AD4 – selects address of third unit downstream for loopback
AD5 – selects address of fourth unit downstream for loopback
AD6 – selects address of fifth unit downstream for loopback
LPBK – forces this unit to set up bidirectional loopback for selected B1 or B2 channel
CRTX – sets up loopback toward carrier
SW1-6: Zero Byte Substitution (ZBS)
Enables or disables ZBS
I
Note: ZBS must be set the same for the COT and RT. For AMI-provisioned carriers,
ZBS should be enabled. Setting is optional for B8ZS-provisioned carriers.
LPTX – sets up loopback toward the loop
NT1 – selects address of the NT1 for loopback
COMPLIANCE
Code
Power Code (PC)
Telecommunication Code (TC)
Installation Code (IC)
Input Output
This product is intended to be installed
in products providing a Type “B” or “E”
enclosure and in restricted access location
only.
F
–
A
C
X
–
I
TEST – initiates selected loopback test from rotary switch
DIP SWITCHES
WARRANTY
I
B1/B2 – selects which B channel, B1 or B2, to be tested during local tests
NORM/PTRN – used to select whether test pattern is sent from a test set or the unit itself
NORM – test pattern is sent from test set plugged into faceplate bantam jacks
PTRN – test pattern, 2047, is internally generated and transmitted
Warranty for Carrier Networks products manufactured by ADTRAN and supplied
under Buyer’s order for use in the U.S. is ten (10) years. For a complete copy of
ADTRAN’s U.S. and Canada Carrier Networks Equipment Warranty, call
(877) 457-5007, Document #414.
I
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
I For a complete Installation and Maintenance Practice: (877) 457-5007, Document # 427. Please have your fax number available. I
|