ADTRAN Network Card T200 HDSL4 User Manual

T200 HDSL4 Transceiver Unit, Remote-Local Powered  
61223424L2-22B  
0505  
FRONT PANEL LED STATUS  
CARD EDGE PINOUTS  
HDSL4  
DSL1/DSL2  
!
Green  
Loop 1/Loop 2 synchronization achieved and signal is present  
No errors currently detected, and SNR margin 3 dB  
Loop 1/Loop 2 synchronization not achieved, in sync with  
errors, or SNR margin < 3 dB  
Pin  
1
Designation  
CH GND  
DS1-T1  
H1-T  
Description  
T200 H4TU-R  
Chassis ground  
!
Red  
P/N 1223424L2  
5
DS1 receive out tip (to customer interface)  
HDSL4 Loop tip (facility)  
CLEI: T1L83Z3C_ _  
7
DS1  
!
!
Green  
Red  
DS1 signal present and no errors currently detected  
No DS1 signal, or signal present with errors  
11  
13  
15  
17  
20  
27  
35  
41  
47  
49  
55  
CH GND  
H1-R  
Chassis ground  
HDSL4 Loop ring (facility)  
DS1-R1  
48 VR  
DS1 receive out ring (to customer interface)  
48 VDC Return  
ALM  
"
!
!
Off  
Yellow  
Red  
No active alarm present  
Loss of DSX-1 signal from the network  
Loss of DS1 signal from the customer (CPE)  
1223424L2  
LOCAL  
VCC  
+5 VDC for protection switching  
Chassis ground  
DSL 1  
DSL 2  
ESF/SF  
CH GND  
48 V  
"
!
!
Off  
Green  
Yellow  
Unit is provisioned for UNFRAMED data  
Unit is provisioned for SF data  
Unit is provisioned for ESF data  
48 VDC; range ±24 to ± 56 VDC (48 VDC nominal)  
HDSL4 Tip (Loop 2)  
DS1  
ALM  
H2-T  
H2-R  
HDSL4 Ring (Loop 2)  
B8ZS/AMI  
LLB/RLB  
!
!
Green  
Yellow  
Unit is provisioned for AMI line code  
Unit is provisioned for B8ZS line code  
DS1-R  
DS1-T  
DS1 transmit in ring (from customer interface)  
DS1 transmit in tip (from customer interface  
ESF/SF  
(YEL) (GRN)  
"
!
!
Off  
Yellow  
Green  
No local loopbacks active  
Local loopback active  
Active loopback at the H4TU-C toward the customer  
B8ZS/AMI  
(YEL) (GRN)  
PROVISIONING OPTIONS  
Provisioning options are assumed from settings made at the H4TU-C.  
LLB/RLB  
(YEL) (GRN)  
OPTIONS  
Front Panel Pushbuttons  
LOC Initiates a bidirectional loopback of the T200 H4TU-R toward the network and customer  
REM Initiates a loopback at the H4TU-C toward the customer  
FEATURES  
TScan  
LOC  
The ADTRAN® T200 H4TU-R incorporates the TScanfeature. TScan allows for remote  
retrieval of circuit diagnostics and performs advanced fault location. For more information about  
TScan refer to the Installation and Maintenance practice.  
LBK  
REM  
Bad Splice Detection  
DS1 MONITOR JACKS  
TX DS1 signal from the DCP toward network (nonintrusive)  
RX DS1 receive from the local loop (nonintrusive)  
The Runtime TScan bad splice detection feature is an ADTRAN proprietary non-intrusive method  
for detection of anomalies (bad splices) in the copper plant. This feature non-intrusively monitors  
the cable pair during runtime for the presence of bad splices, which may potentially impact service.  
Poor splices in the cable are often undetected by normal testing methods. Often, these splices  
present no problem for the data transmission equipment until the point at which oxidation with the  
splice itself causes a rapid impedance change. Such a change in impedance may cause errors,  
signal margin fluctuation, and/or a retrain of the DSL transceivers. The splice detection feature is  
accessed from the Troubleshooting Screen via the craft access port.  
TX  
M
O
N
POWER  
RX  
This specific unit is intended for Local Power Only. If a Span Powered unit is required, refer to  
P/N 1223426L2.  
A local power supply is available from ADTRAN by ordering P/N 1353.DSK48V04.  
Fast Retrain  
R
S
2
3
2
COMPLIANCE  
Fast Retrain is an ADTRAN proprietary feature that minimizes downtime due to an intermittent  
impairment which due to its duration cannot be bridged. When such impairments occur, the fast  
retrain feature will be invoked to restore service within 5 to 7 seconds, instead of the traditional 25  
to 30 second retrain duration.  
This product is intended to be installed in Restricted Access Areas only and in equipment with  
a Type “B” or “E” enclosure.  
Code  
Input  
Output  
NOTE: Fast-Retrain capable units must be installed on both ends of the circuit for this feature  
to function properly. Also, if there is a failure, for any reason, of a fast retrain attempt  
then the traditional (25-30 second) retrain will be initiated.  
Power Code  
C
X
A
C
X
Telecommunication Code (TC)  
Installation Code (IC)  
This product meets all requirements of Bellcore GR-1089-CORE (Class A2), ANSI T1.418-  
2002. This product is NRTL listed to the applicable UL standards.  
WARNING: Up to –200 VDC may be present on telecommunications wiring. Ensure  
Chassis ground is properly connected.  
C A U T I O N !  
SUBJECT TO ELECTROSTATIC DAMAGE  
OR DECREASE IN RELIABILITY.  
HANDLING PRECAUTIONS REQUIRED.  
For more information, refer to the Installation and Maintenance Practice (P/N 61223HDSL4L2-5) available online at www.adtran.com.  
 

3Com Switch 3C16980 User Manual
AEG Freezer S83600CSM1 User Manual
Agilent Technologies Computer Accessories G3180B User Manual
Agilent Technologies Network Router J3919A User Manual
Alvarez Car Speaker SA1232z User Manual
American DJ DJ Equipment Uni Pack User Manual
Avet Reels Fishing Equipment LX 46 User Manual
Axis Communications Security Camera 31922 User Manual
Barco Graphics Tablet R9851560 User Manual
Beckett Welding System 7514 User Manual