T200 HDSL4 Transceiver Unit, Remote-Local Powered
61223424L2-22B
0505
FRONT PANEL LED STATUS
CARD EDGE PINOUTS
HDSL4
DSL1/DSL2
!
Green
Loop 1/Loop 2 synchronization achieved and signal is present
No errors currently detected, and SNR margin ≥ 3 dB
Loop 1/Loop 2 synchronization not achieved, in sync with
errors, or SNR margin < 3 dB
Pin
1
Designation
CH GND
DS1-T1
H1-T
Description
T200 H4TU-R
Chassis ground
!
Red
P/N 1223424L2
5
DS1 receive out tip (to customer interface)
HDSL4 Loop tip (facility)
CLEI: T1L83Z3C_ _
7
DS1
!
!
Green
Red
DS1 signal present and no errors currently detected
No DS1 signal, or signal present with errors
11
13
15
17
20
27
35
41
47
49
55
CH GND
H1-R
Chassis ground
HDSL4 Loop ring (facility)
DS1-R1
48 VR
DS1 receive out ring (to customer interface)
48 VDC Return
ALM
"
!
!
Off
Yellow
Red
No active alarm present
Loss of DSX-1 signal from the network
Loss of DS1 signal from the customer (CPE)
1223424L2
LOCAL
VCC
+5 VDC for protection switching
Chassis ground
DSL 1
DSL 2
ESF/SF
CH GND
48 V
"
!
!
Off
Green
Yellow
Unit is provisioned for UNFRAMED data
Unit is provisioned for SF data
Unit is provisioned for ESF data
48 VDC; range ±24 to ± 56 VDC (48 VDC nominal)
HDSL4 Tip (Loop 2)
DS1
ALM
H2-T
H2-R
HDSL4 Ring (Loop 2)
B8ZS/AMI
LLB/RLB
!
!
Green
Yellow
Unit is provisioned for AMI line code
Unit is provisioned for B8ZS line code
DS1-R
DS1-T
DS1 transmit in ring (from customer interface)
DS1 transmit in tip (from customer interface
ESF/SF
(YEL) (GRN)
"
!
!
Off
Yellow
Green
No local loopbacks active
Local loopback active
Active loopback at the H4TU-C toward the customer
B8ZS/AMI
(YEL) (GRN)
PROVISIONING OPTIONS
Provisioning options are assumed from settings made at the H4TU-C.
LLB/RLB
(YEL) (GRN)
OPTIONS
Front Panel Pushbuttons
LOC Initiates a bidirectional loopback of the T200 H4TU-R toward the network and customer
REM Initiates a loopback at the H4TU-C toward the customer
FEATURES
TScan
LOC
The ADTRAN® T200 H4TU-R incorporates the TScan™ feature. TScan allows for remote
retrieval of circuit diagnostics and performs advanced fault location. For more information about
TScan refer to the Installation and Maintenance practice.
LBK
REM
Bad Splice Detection
DS1 MONITOR JACKS
TX DS1 signal from the DCP toward network (nonintrusive)
RX DS1 receive from the local loop (nonintrusive)
The Runtime TScan bad splice detection feature is an ADTRAN proprietary non-intrusive method
for detection of anomalies (bad splices) in the copper plant. This feature non-intrusively monitors
the cable pair during runtime for the presence of bad splices, which may potentially impact service.
Poor splices in the cable are often undetected by normal testing methods. Often, these splices
present no problem for the data transmission equipment until the point at which oxidation with the
splice itself causes a rapid impedance change. Such a change in impedance may cause errors,
signal margin fluctuation, and/or a retrain of the DSL transceivers. The splice detection feature is
accessed from the Troubleshooting Screen via the craft access port.
TX
M
O
N
POWER
RX
This specific unit is intended for Local Power Only. If a Span Powered unit is required, refer to
P/N 1223426L2.
A local power supply is available from ADTRAN by ordering P/N 1353.DSK48V04.
Fast Retrain
R
S
2
3
2
COMPLIANCE
Fast Retrain is an ADTRAN proprietary feature that minimizes downtime due to an intermittent
impairment which due to its duration cannot be bridged. When such impairments occur, the fast
retrain feature will be invoked to restore service within 5 to 7 seconds, instead of the traditional 25
to 30 second retrain duration.
This product is intended to be installed in Restricted Access Areas only and in equipment with
a Type “B” or “E” enclosure.
Code
Input
Output
NOTE: Fast-Retrain capable units must be installed on both ends of the circuit for this feature
to function properly. Also, if there is a failure, for any reason, of a fast retrain attempt
then the traditional (25-30 second) retrain will be initiated.
Power Code
C
X
A
C
X
–
Telecommunication Code (TC)
Installation Code (IC)
This product meets all requirements of Bellcore GR-1089-CORE (Class A2), ANSI T1.418-
2002. This product is NRTL listed to the applicable UL standards.
WARNING: Up to –200 VDC may be present on telecommunications wiring. Ensure
Chassis ground is properly connected.
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
For more information, refer to the Installation and Maintenance Practice (P/N 61223HDSL4L2-5) available online at www.adtran.com.
|