DX 845 W
DX 865
DX 985
Titan Energy
Titan Energy X
Betriebsanleitung ...................... 2
Operating Instructions .............. 8
Notice d'utilisation .................. 14
Gebruiksaanwijzing ................ 20
Istruzioni sull'uso..................... 26
Käyttöohje ............................... 32
Navodilo za uporabo................... 38
Uputstvo za rad............................ 44
Prevádzkový návod ..................... 50
Provozní návod ............................ 56
Instrukcja obsługi........................ 62
Kezelési utasítás.......................... 68
Instrucciones de manejo ......... 74
Instruções de operação ........... 80
Οδηγίες λειτουργίας ................. 86
Ýþletme kýlavuzu....................... 92
DX 845 W / DX 865 / DX 985 / Titan Energy / Titan Energy X
2
5
3
6
9
4
7
4
1
3
8
10
13
1
2
0
11
12
140
60
212
10
0
70 20
F
C
1
A
C
max
min
B
EG - Konformitätserklärung
Déclaration de conformité CE
Wap Reinigungssysteme GmbH
Guido-Oberdorfer-Straße 2-8
D-89287 Bellenberg
&
Co.
Wap Reinigungssysteme GmbH
Guido-Oberdorfer-Straße 2-8
D-89287 Bellenberg
&
Co.
Hochdruckreiniger
Produit:
Type:
Nettoyeur haute pression
Erzeugnis:
Typ:
DX 845 W, DX 865,
DX 845 W, DX 865,
DX 985, Titan Energy, Titan Energy X
DX 985, Titan Energy, Titan Energy X
IP X5, Schutzklasse I, 50 Hz.
Description:
IP X5, Classe de protection I, 50 Hz.
Directive CE relative aux machines 89/392/EWG
Beschreibung:
EG-Maschinenrichtlinie
EG-Niederspannungsrichtlinie73/23/EWG
EG-Richtlinie EMV
89/392/EWG
La construction de l’appareil est
conforme aux réglementations
afférentes suivantes:
Die Bauart des Gerätes entspricht
folgenden einschlägigen
Bestimmungen:
Directive CE relative à basse tension 73/23/EWG
89/336/EWG
Directive CE EMV
89/336/EWG
EN 292
EN 60335-1, EN 60555-3
EN 50081
Normes harmonisées appliquées:
EN 292
EN 60335-1, EN 60555-3
EN 50081
Angewendete harmonisierte
Normen:
DIN EN 60335-1
E-DIN VDE 0700 T 265
IEC 335-2-79
Normes nationales et
spécifications techniques
appliquées:
DIN EN 60335-1
E-DIN VDE 0700 T 265
IEC 335-2-79
Angwendete nationale Normen
und technische Spezifikationen:
Johan Ley
VP Tech-OP
Dipl.Ing. W. Nieuwkamp
Controles et homologations
Johan Ley
VP Tech-OP
Dipl.Ing. W. Nieuwkamp
Prüfungen und Zulassungen
Bellenberg, 21.08.2000
Bellenberg, 21.08.2000
EU Declaration of Conformity
Dichiarazione di conformità CE
Wap Reinigungssysteme GmbH
Guido-Oberdorfer-Straße 2-8
D-89287 Bellenberg
&
Co.
Wap Reinigungssysteme GmbH
Guido-Oberdorfer-Straße 2-8
D-89287 Bellenberg
&
Co.
Product:
Type:
High Pressure Cleaner
Prodotto:
Tipo:
Pulitrice ad alta pressione
DX 845 W, DX 865,
DX 985, Titan Energy, Titan Energy X
DX 845 W, DX 865,
DX 985, Titan Energy, Titan Energy X
Description:
IP X5, Protection class I, 50 Hz.
Descrizione:
IP X5, Classe di protezione I, 50 Hz.
The design of the unit corresponds EC Machine Directive
89/392/EWG
73/23/EWG
89/336/EWG
La costruzione dell' apparecchio è Direttiva CE sulle macchine
conforme alle seguenti direttive Direttiva CE sulla bassa tensione
89/392/EWG
73/23/EWG
89/336/EWG
to the following pertinent
regulations:
EC Low-voltage Directive
EC EMV Directive
specifiche:
Direttiva CE sulla compatibilità
elektromagnetica
Applied harmonised standards:
EN 292
EN 60335-1, EN 60555-3
EN 50081
Norme armonizzate applicate:
EN 292
EN 60335-1, EN 60555-3
EN 50081
Applied national standards and
technical specifications:
DIN EN 60335-1
E-DIN VDE 0700 T 265
IEC 335-2-79
Norme nazionali applicate e
specifiche tecniche:
DIN EN 60335-1
E-DIN VDE 0700 T 265
IEC 335-2-79
Johan Ley
VP Tech-OP
Dipl.Ing. W. Nieuwkamp
Controlli omologazioni
Johan Ley
VP Tech-OP
Dipl.Ing. W. Nieuwkamp
Tests And Approvals
e
Bellenberg, 21.08.2000
Bellenberg, 21.08.2000
Atestado de conformidad de la UE
EG-Verklaring van overeenstemming
Wap Reinigungssysteme GmbH
Guido-Oberdorfer-Straße 2-8
D-89287 Bellenberg
&
Co.
Wap Reinigungssysteme GmbH
Guido-Oberdorfer-Straße 2-8
D-89287 Bellenberg
&
Co.
Producto:
Modelo:
Máquina de limpieza a alta presión
Produkt:
Type:
Hogedrukreiniger
DX 845 W, DX 865,
DX 845 W, DX 865,
DX 985, Titan Energy, Titan Energy X
DX 985, Titan Energy, Titan Energy X
Descripción:
IP X5, Clase de protección I, 50 Hz.
Beschrijving:
IP X5, Beschermklasse I, 50 Hz.
La construcción de la máquina
corresponde a las siguientes
normas específicas:
R. de la UE para máquinas 89/392/EWG
De constructie van het apparaat EG-machinerichtlijn
voldoet aan de volgende van EG-laagspanningsrichtlijn 73/23/EWG
toepassing zijnde voorschriften: EG-richtlijn EMV
89/392/EWG
R. de la UE para baja tensión
EWG
73/23/
89/336/EWG
R. de la UE para la compati-
bilidad electromagnética
89/336/EWG
Toegepaste geharmoniseerde
normen:
EN 292
EN 60335-1, EN 60555-3
EN 50081
Normas armonizadas aplicadas:
EN 292
EN 60335-1, EN 60555-3
EN 50081
Toegepaste nationale normen en DIN EN 60335-1
Normas nacionales aplicadas y
especificaciones técnicas:
DIN EN 60335-1
E-DIN VDE 0700 T 265
IEC 335-2-79
technische specificaties:
E-DIN VDE 0700 T 265
IEC 335-2-79
Johan Ley
VP Tech-OP
Dipl.Ing. W. Nieuwkamp
Keuringen en vergunningen
Johan Ley
VP Tech-OP
Dipl.Ing. W. Nieuwkamp
Bellenberg, 21.08.2000
Bellenberg, 21.08.2000
Pruebas
y
homologaciones
DX 845 W / DX 865 / DX 985 / TitanEnergy / TitanEnergy X
READ THE OPERATING
INSTRUCTIONS AND
OBSERVE THE
ENCLOSED SAFETY
NOTES!
Use only Alto products developed
for your high-pressure cleaner as
cleaning agents.
GB
GENERAL
Your Alto high-pressure cleaner
has been developed specially for
professional use.
We observe time and again that
faults are due to the use of
unsuitable products.
If you observe these operating
instructions and comply with the
notes given, your high-pressure
cleaner will help you in your
cleaning work for many years to
come.
The following table gives an
overview of the potential applica-
tions and of the corresponding
Alto cleaning agents.
pH
value in
1%
solution
approx.
No. Pure or
Unsuitable cleaning
agents lead to poor
cleaning results and
cause damage to the
machine. Predilute the
concentrate as
%
5,0
pre-
diluted
Undiluted
4,0
3,0
2,0
1,0
0
instructed.
1:1
Alto AutoActive
1:2
Intensive acting concentrate
against dust, soot, greases,
oils and insect residues. For
delicate surfaces.
Mixing ratio
1:5
9,5
9,1
81218 1:10
1:10
1:20
0
6
19
32
45 Additivethrough-
put approx. l/h
Alto Intensive
Setting on the
metering valve
Multi-purpose concentrate
for heavy soiling on
engines, machine parts, in
workshops, on trucks and
on tarpaulins.
81227 1:10
Further highly effective cleaning and care
agents can be found in the catalogue "Alto
Cleaning and Care Agents".
building regulations must be
DESCRIPTION (FIG. 1)
BEFORE STARTING WORK
observed. We will be glad to
provide tips for connection
systems, on request.
1
RotoFix high-pressure spray
lance with VarioPress trigger
gun1)
Water connection
Steering roller with parking
brake
High-pressure connection
Cleaning agent tank
Mains cable storage point
Hose storage point
Spray lance storage clip
Exhaust pipe
If the machine is to be operated
at fuel stations or in other
The machine must be supervised
at all times so that the operator
can notice when the flame goes
out.
2
3
potentially hazardous areas, the
machine may only be employed
outside the hazard areas defined
in the "Technical Guidelines for
Inflammable Fluids" applicable at
the point of use due to the
potential explosion hazard posed
by the burner.
4
5
6
7
8
9
ð Secure the machine with
the parking brake (Fig. 2).
ð Check the oil level in the
high-pressure pump (Fig. 3).
ð Fill the cleaning agent tank
with prediluted Alto cleaning
agent.
ð With the machine cold:
Pour fuel (fuel oil EL, biodiesel
E to DIN 51 606 or diesel fuel
to DIN 51 603) into the fuel
tank.
10 Operating panel
11 Fuel tank
12 Pressure gauge
13 Temperature controller
14 Operation indicator light
15 Fuel shortage indicator
16 Scale alarm1)
If the machine is to be operated
indoors, the local building
regulations must be observed for
the discharge of the exhaust
fumes into the atmosphere.
Ensure an adequate supply of
fresh air.
17 Operating mode switch
18 Cleaning agent metering
knob
The fuel must be free from
contamination.
If the machine is to be connected
to a flue gas stack, the state
–
Tank capacity: 30 litres
1) Option / model variants
8
DX 845 W / DX 865 / DX 985 / TitanEnergy / TitanEnergy X
COLD WATER OPERATION
OPERATION OF THE ROTOFIX
HIGH-PRESSURE SPRAY LANCE
GB
ð Release the lock of the trigger
gun and press the trigger (Fig.8).
ð Turn the operating mode
The RotoFix high-pressure spray
lance allows the spray lance to
be turned for pressure-free
operation:
ð Push back the slide of the
locking pin (Fig. 5).
Unsuitable fuels must not be
used as they can represent a
source of danger.
switch to position
.
-> The function test of the
displays on the operating
panel starts.
At temperatures below 8° C,
the fuel oil begins to solidify
(paraffin precipitation). This
can lead to difficulties in
starting the burner. Before the
winter period either add a
solidification point / flow
improver (available from the
fuel oil trade) to the fuel or
use winter diesel fuel.
–
All the indicator lights
come on briefly, then the
ð Turn the screw fitting of the
RotoFix high-pressure spray
lance until the pin engages in
the next bore.
indicator light
comes on
continuously to indicate
that the machine is ready
for operation.
OPERATION OF THE COAXIAL
SPRAY LANCE1)
ð Operate the trigger of the
trigger gun several times at
short intervals to bleed the
system.
ð Fill the tank for the Alto
automatic scale alarm system.
"Alto Anti-Stone" prevents any
deposits of scale and acts at
the same time as a corrosion
inhibitor. Use the bottle
ð The working pressure can be
steplessly varied by turning the
handle of the spray lance, but
with a constant volume of
water (Fig. 10).
HOT WATER OPERATION
supplied with the pack for
filling (Fig. 4). For compatibili-
ty reasons, use only the tested
"Alto Anti-Stone". Order the
refill pack 6 x 1000 ml, No.
8466, in good time.
ð Select the temperature (20-
100° C).
ð Release the lock of the trigger
gun and press the trigger (Fig.8).
ð Turn the operating mode
OPERATION OF THE PRESSURE
AND WATER VOLUME
CONTROLLER
switch to position
.
ð Screw the high-pressure hose
firmly onto the VarioPress
trigger gun1), pushing back the
slide of the locking pin (Fig. 5/
1 + 5/2).
ð Securely tighten the screw of
the Roto-Fix high-pressure
spray lance, at the same time
pushing back the slide of the
locking pin (Fig. 5/3 + 5/4).
ð Connect the water hose (Fig. 6).
The use of a fabric-reinforced
water hose with a nominal
diameter of at least 1/2" (13
mm) is recommended.
DX 845 W:
ð When a steady jet emerges
from the high-pressure nozzle,
turn the operating mode
ð The rotary knob on the safety
control block allows the
pressure and water volume to
be steplessly varied (Fig. 9).
switch to position
.
Using a special device1), the
condensate coming out of the
heat exchanger can be collected
and disposed of in accordance
with the local sewage regulati-
ons; water poured in and emer-
ging at the nozzle then has the
same composition.
DX 865, DX 985, TitanEnergy,
TitanEnergy X:
Stepless variation of pressure and
water volume
ð Continuous operation =
Rotary knob on the safety
control block (Fig. 9).
ð Brief operation = Rotary knob
on the VarioPress trigger gun1)
(Fig. 11).
ð Connect the high-pressure
hose to the high-pressure
connection. Ensure that the
union nut is securely tightened
(Fig. 7)!
STEAM OPERATION
(OVER 100° C)1)
The set pressure can be read off
from the pressure gauge.
Replace the standard high-
pressure nozzle with the steam
spray nozzle (No. 6692)1). Set the
thermostat to a temperature of
above 100° C. Turn the rotary
knob on the safety control block
completely to the left (anticlock-
wise direction) (Fig. 9). Release
the lock of the trigger gun and
press the trigger. Turn the opera-
ting mode switch to position
ð Turn on the water tap.
ð Insert the plug of the cleaner
into the plug socket.
USE OF CLEANING AGENTS
ð Predilute cleaning agents as
described under "General"
and pour into the cleaning
agent tank.
ð Set the desired concentration
of the cleaning agent (table,
see section "General") at the
metering valve (Fig. 12).
ð Spray the object to be clea-
ned.
STARTING OPERATION
RTING OPERATION
The pipework of the machine
is filled with antifreeze.
Collect the first liquid (approx.
5 litres) which comes out of
the spray gun in a suitable
vessel for further use.
When a steady jet emerges from
the steam spray nozzle, turn the
operating mode switch to positi-
on
.
ð Allow the cleaning agent to
1) Option / model variants
9
DX 845 W / DX 865 / DX 985 / TitanEnergy / TitanEnergy X
work, depending on the
degree of soiling, then rinse
off with the high-pressure
spray jet.
PUMP SYSTEM
GB
SERVICE AND MAINTENANCE
ð Clean the screens and filter in
the water inlet line (float
valve, high-pressure pump
inlet).
ð Grease the manual screw
fittings on the spray lance and
high-pressure hose.
The maintenance operations
The cleaning agent must
not be allowed to dry on
the surface!
marked with
should only be
carried out by the Alto service
technician.
MAINTENANCE SCHEDULE
FINISHING OPERATION AND
STORAGE
Weekly or every 40 opera-
ting hours
FLAME SENSOR
ð Turn the metering valve to
ð Check the oil level
ð Remove the sensor and clean
with a soft cloth.
position
ð Turn the operating mode switch
to position
.
Every 3 months or every
200 operating hours
ð Change the pump oil
ð Pump system
Ensure that the sensor is
correctly seated when instal-
ling again.
.
ð Allow the machine to run for
approx. 1 minute, then turn the
operating mode switch to
position OFF.
ð Actuate the trigger gun until the
machine is completely depressu-
rised.
ð Insert the safety lock (Fig. 8/1).
ð Turn off the water tap.
ð Pull the machine plug out of the
plug socket and coil up the
mains cable.
ð Disconnect the water hose from
the machine.
ð Store the machine in a frost-
proof room where it is safe from
unauthorised use.
ð Flame sensor
HEAT EXCHANGER AND
IGNITION SYSTEM
Annually or every 500
operating hours
ð Heat exchanger and
ignition system
ð Have cleaning carried out by
the Alto service technician,
see "Maintenance schedule".
ð Fuel system
As required
FUEL SYSTEM
ð Grease the manual
screw fittings on the
spray lance and high-
pressure hose
ð Empty the fuel tank. Clean
the tank and fuel lines.
ð Dispose of the cleaning fluid
in accordance with the
ð Descale the system
disposal regulations.
OIL LEVEL CHECK / OIL
CHANGE
If the machine cannot be stored in a
frost-proof room, proceed as follows:
ð Turn off the water tap.
SETTING OF THE ALTO
AUTOMATIC SCALE ALARM
SYSTEM
Check the oil level in the high-
pressure pump regularly at the
oilglass (Fig. 3).
ð Turn the operating mode switch
to position
and actuate
the trigger gun
The automatic scale alarm
system is set at the factory to
water hardness class 2. Should
an adjustment be necessary,
proceed as follows:
ð Measure the water hardness
or ask your water supply
company.
ð Gradually pour antifreeze
(approx. 5 litres) into the water
tank.
ð The machine is protected against
frost when antifreeze solution
emerges from the nozzle of the
spray lance.
ð When the machine is put into
service again, the antifreeze
solution can be collected and
stored for future use.
ð Top up with oil when required.
ð If the oil has a grey or white
shade, change the oil.
Unscrew the oil drain plug on
the pump housing and
dispose of the old oil in
accordance with the disposal
regulations.
ð Set the number of drops per
minute (see table) at the
metering device (Fig. 13).
ð Renew the drain plug gasket
and screw in the plug again.
ð Fill with oil and close the oil
filler plug.
Hardness
class
°dH Drops/min.
Oil grade:
AlphaSynt 150
1 soft
0-7
10
(Order-no. 5218433)
2 medium-
hard
3 hard
Oil capacity: DX 0.35 l
7-14
14-21
20
30
40
4 very hard >21
1°dH = 1,25°e = 1,79°f
1) Option / model variants
10
DX 845 W / DX 865 / DX 985 / TitanEnergy / TitanEnergy X
DESCALING
steady jet of water must
emerge at the water outlet
tube. If this is not the case,
repeat the descaling procedu-
re.
GB
ð Screw the high-pressure
nozzle onto the spray lance.
Descaling agents cause burns.
Avoid contact with the skin,
eyes and clothes. Wear appro-
priate protective clothing (e.g.
gloves, face mask, apron).
FROST PROTECTION
Only approved scale removers
may be used for descaling.
Use Alto Stone-EX, No. 81236
If the high-pressure cleaner is
stored in a room in which tempe-
ratures of below 0° C can occur,
antifreeze must first be flushed
through the pump.
With regular use of Alto
Anti-Stone, descaling will
normally not be necessary.
During the flushing process,
actuate the trigger gun 2 or 3
times.
Incorrect operation of the machi-
ne or the use of non-approved
cleaning agents can cause
deposits in the pipework system.
Scaling is caused by the water
hardness and is indicated by a
gradual increase in the water
pressure displayed on the pressu-
re gauge.
In order to avoid any risk, the
machine should preferably be
stored for a short period in a
heated room before it is put into
service again.
If the working pressure is excee-
ded by 10 bar (with the Vario-
Press trigger gun open), the
system must be descaled.
Procedure:
ð Unscrew the high-pressure
nozzle from the spray lance
and place separately in the
Alto scale remover.
ð Draw in Alto scale remover
via the metering valve by
hanging a cleaning agent
hose into the scale remover
bottle and setting the mete-
ring valve to maximum
concentration.
ð Hold the spray lance in a
separate container to collect
the discharged liquid.
ð Switch on the high-pressure
pump.
ð Actuate the trigger gun. Alto
scale remover is drawn in and
emerges from the spray lance
foaming vigorously after
approx. 1 minute.
ð Switch off the high-pressure
pump and allow the scale
remover to work for approx.
15 minutes.
ð Flush out the pump system
well with clean water.
ð After approx. 2 minutes, a
1) Option / model variants
11
DX 845 W / DX 865 / DX 985 / TitanEnergy / TitanEnergy X
GB
TROUBLESHOOTING
Before working on the machi-
ne, remove the mains lead
plug and depressurise the
machine.
FAULT
CAUSE
REMEDY
‡
‡
Display
machine does not start
does not light up,
>
>
Fault in the mains cable
Motor overheated
ð
Have electrical connection checked
Display
flashes rapidly (5x per
ð
ð
Clean or replace clogged high-
pressure nozzle
Set the VarioPress control knob
on the trigger gun to a higher
pressure
second), motor has cut out and will
not start again
ð
ð
Possible phase failure; have
electrical connection checked
‡
‡
Display
Display
is lit continuously
is lit continuously
>
Anti-Stone concentrate container
empty
Top up anti-scale concentrate
container
>
>
>
Fuel tank empty
Contamination or water in fuel
Burner sooted
ð
ð
ð
Top up fuel tank
Clean fuel tank and pipework
Have burner setting checked
‡
Display
second)
flashes slowly (1x per
>
Inadequate water inlet
ð
Use water hose with at least 1/2"
diameter, clean filter in water inlet
Top up cleaning agent tank
Set pressure and volume controller
or VarioPress control knob on the
trigger gun to a higher pressure
>
>
Cleaning agent tank empty
Pressure and volume controller or
VarioPress trigger gun set too low
ð
ð
‡
‡
Display
flashes rapidly (5x per
>
>
Flame sensor sooted
Fault in ignition or fuel system
ð
ð
Remove and clean
Call service technician
second), burner will not start again
Machine stops and starts intermit-
tently with the trigger gun open
>
>
High-pressure nozzle soiled
Machine scaled
ð
ð
Clean or replace high-pressure
nozzle
Descale according to the instruc-
tions
‡
‡
Machine stops and starts intermit-
tently with the trigger gun closed
>
>
Trigger gun leaking
High-pressure hose, high-pressure
screw fitting or pipework leaking
ð
ð
Inspect the trigger gun
Retighten screw fittings, replace
high-pressure hose or pipework
Pressure too low
>
>
>
Cleaning agent tank empty
High-pressure nozzle worn
Pressure and volume controller or
VarioPress trigger gun set too low
ð
ð
ð
Top up cleaning agent tank
Replace high-pressure nozzle
Set pressure and volume controller
or VarioPress control knob on the
trigger gun to a higher pressure
Clean filter
>
>
>
Filter in water inlet clogged
ð
ð
ð
High-pressure pump drawing in air
Suction or pressure valve of high-
pressure pump soiled or defective
Repair leaks
Clean or replace valves
‡
Cleaning agent is not drawn in
>
>
>
Cleaning agent tank empty
Sludge in cleaning agent tank
Suction valve at cleaning agent
inlet soiled
ð
ð
ð
Top up cleaning agent tank
Clean cleaning agent tank
Remove suction valve and clean or
replace
1) Option / model variants
12
DX 845 W / DX 865 / DX 985 / TitanEnergy / TitanEnergy X
GB
TECHNICAL DATA
DX 845 DX 865
TitanEnergy
DX 985
TitanEnergyX
Working pressure
bar
bar
l/h
170-30
190-30
200-30
180-30
100-30 (UK)
100-30
180-30
250/32
Permissible overpressure
Volumetric flow
250/32
200/32
250/32 250/32
250/32
200/32 (UK)
900-400
900-400 980-400
700-400 800-400 900-400
700-400 (UK)
Permissible temperature
Voltage 230 V AC
°C
UK
80...140 80...140 80...140 80...140 75...140
EU
80...140
Voltage 200 V 3-phase AC
Voltage 220 V 3-phase AC
Voltage 230 V 3-phase AC
Voltage 380 V 3-phase AC
Voltage 380-415 V 3-phase AC
Voltage 400-415 V 3-phase AC
Frequency
JP
KR
E,B,N
JP
KR
E,B,N
E,B,N
E,B,N
E,B,N
50
EU
EU
EU
EU
50
UK
50
Hz
50
50
50
60 (JP,KR) 60 (JP,KR)
Rated power
Fuse
kW
A
16
5,6
16
7,9
16
6,6
16
3,0
6,9
16
6,6
16
13 (UK)
I
20 (JP,KR) 25 (JP,KR)
I
13 (UK)
I
Protection class
I
I
I
Type of protection
Water volume of the heater coil
Heating capacity
Fuel tank capacity
Cleaning agent tank capacity
3,5
3,5
X5
X5
3,5
62
30
2x15
X5
X5
3,5
62
30
X5
3,5
62
30
2x15
10
X5
l
3,5
kW
62
62
62
l
l
30
30
30
2x15
2x15
10
2x15
2x15
Permissible water inlet pressure bar
10
10
10
10
Dimensions L x W x H
Machine weight
mm
1060 x 705 x 758
1560x705x758
154
161
173
5
173
5
175 188
(weight of trigger gun)
Sound pressure level at a
distance of 1 m from
the machine DIN 45635
Oil fill capacity
kg
5
5
5
5
dB(A)
79,9
82,6
0,35
83,5
0,35
84,4
0,35
83,5
0,35
83,5
0,35
47
l
N
0,35
Recoil forces
41
47
54
47
28
28(UK)
Please observe the technical data on
INSTRUCTIONS FOR DISPOSAL
GUARANTEE
At the end of the machine's
service life:
Our general terms and conditions
apply to the guarantee and
warranty.
Changes in line with technical
innovation reserved.
ð Remove the mains lead plug.
ð Cut through the mains lead.
ð Take the machine and the
mains lead to your local
electrical appliance recycling
collection point.
13
|