Installation
Instructions
T005.5XX
COPELAND
PRESSURE BALANCING BATH
AND SHOWER TRIM KITS
Thank you for selecting American-Standard...the benchmark
of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please
read these instructions carefully before you begin.
Certified to comply with ANSI A112.18.1
M968636 Rev 1.1
Recommended Tools
Phillips Screwdriver
Adjustable Wrench
Channel Locks
Plumbers' Putty or Caulking
Teflon Tape
Flat Blade Screwdriver
ROUGHING-IN DIMENSIONS (For reference only)
To assure proper positioning in relation to wall, note roughing-in dimensions.
INLETS
1/2" NOM.
COPPER
SWEAT
1-5/8" TO 3"
1/2" NPT
INLETS
4-1/16"
SHR. 1/2" NOM.
COPPER SWEAT
FINISHED WALL
SWEAT
INLETS
2"
4-1/4" REF.
4-1/16"
TUB 1/2" NOM.
COPPER SWEAT
OPTIONAL TO FINISHED
FLOOR USUALLY
BETWEEN 65'' AND 78'
6" REF.
SWEAT
INLETS (STOPS)
5-7/8"
SHR. 1/2" NOM.
COPPER SWEAT
4-1/16"
"SEE ILLUSTRATION "
TUB 1/2" NOM.
COPPER SWEAT
74" FOR HEAD
CLEARANCE
INLETS
1/2" NOM.
COPPER
SWEAT
7-1/2"
OUTLETS
1/2" NPT
INLETS 1/2" NPT
3-3/8"
5-7/8"
INLETS
1/2" NPT
18" OPTIONAL
1-1/2"
3-3/8"
3-3/8"
OUTLETS
1/2" COPPER
FOR SLIP-ON
SPOUT
1/2" NPT
4"
4-7/8" REF.
TOP OF TUB RIM
BOTTOM OF TUB
THREADED INLETS
THREADED INLETS (STOPS)
ADJUST HOT LIMIT STOP
3
HOT LIMIT SAFETY STOP ADJUSTMENT
By restricting handle rotation and limiting the amount
of hot water allowed to mix with the cold, the HOT LIMIT
SAFETY STOP reduces risk of accidental scalding. To set
the maximum hot water temperature of your faucets, all
you need to do is adjust the setting on the HOT LIMIT
SAFETY STOP.
"RED RING"- HOT
LIMIT SAFETY STOP
1
"A"
Use a flat blade screwdriver or your fingers to pull
up and rotate red HOT LIMIT SAFETY STOP (1).
Follow Step "A" or "B" to adjust min./max. discharge
temperature. "0" being the hottest to "7" the coldest
temperature setting. Factory set at "0".
"A"
"B"
ADJUSTMENT WHEN
WATER IS TOO HOT
"B"
ADJUSTMENT WHEN
WATER IS TOO COLD
PRY RED RING
FORWARD AND ROTATE
COUNTER-CLOCKWISE
ONE CLICK
TEMPERATURE
SETTING
NUMBERS
PRY RED RING
FORWARD AND
ROTATE CLOCKWISE
HANDLE INSTALLATION
4
5
6
Install HANDLE (1) by pushing it onto CARTRIDGE STEM (2)
and tightening SET SCREW (3) from below with 2.5mm
Hex Wrench supplied.
2
3
1
2.5MM HEX
WRENCH
SERVICE
If faucet drips, operate handle several times from "off"
to "on". Do not apply excessive force.
1
Clogged CARTRIDGE (4) inlets may cause reduced flow in "full
on" hot or cold. To clean inlets, first turn off water supply, then:
2
4
Remove HANDLE (1), CAP (2) and CARTRIDGE (4). Clean inlets
and MANIFOLD (5).
Reassemble CARTRIDGE (4), alternately tightening SCREWS (3).
Replace CAP (2) and HANDLE (1). Check flow.
3
5
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
M968636 Rev 1.1
COPELAND
PRESSURE BALANCE
BATH/SHOWER
MODEL NUMBER
T005.5XX
M962606-YYY0A
SHOWER ARM
AND FLANGE
M953579-YYY0A
SHOWER HEAD
M962427-0070A
ESCUTCHEON HOLDER
M907050-YYY0A
CAP
M962605-YYY0A
ESCUTCHEON AND SEAL
Replace the "YYY" with
appropriate finish code
M962607-YYY0A
HANDLE
CHROME
SATIN NICKEL 295
002
BLACKENED BRONZE 068
M950234-YYY0A
DIVERTER SPOUT (SLIP-ON)
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1 (800) 442-1902
Weekdays 8:00 a.m. to 6:00 p.m. EST
IN MEXICO 01-800-839-12-00
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
Product names listed herein are trademarks of American Standard Inc.
© American Standard Inc. 2007
M968636 Rev 1.1
|