American Standard Thermostat 605XTMV User Manual

SELECTRONIC™  
Thermostatic Mixing Valve  
605XTMV  
Specifications  
1
2
3
3
4
Installation  
Adjust Temperature  
Service  
Replacement Parts  
Certified to comply with ASME A112.18.1M  
© 2005 American Standard  
M968808  
NOTE TO INSTALLER: Please give this manual to the customer after installation.  
To learn more about American Standard Faucets visit our website at: www.us.amstd.com or U.S.  
customer's e-mail us at: [email protected]  
For Parts, Service, Warranty or other Assistance,  
please call 1-800-442-1902 (In Canada: 1-800-387-0369)  
(In Toronto Area only: 1-905-3061093)  
 
Fig. 3  
INSTALLATION  
LAVATORY RIM OR  
MOUNTING SURFACE  
MOUNT ENCLOSURE; Fig. 3  
1
1. Remove the bottom SUPPLY HOSE (1) from the  
SELECTRONIC ENCLOSURE (2). Fig. 3  
Fig. 3a  
SUPPLIES  
2
2. Remove BOTTOM PLUG (3) from SELECTRONIC  
ENCLOSURE (2). Fig. 3  
1
3
3. Remove 4 screws from MIXER ENCLOSURE  
COVER (2) and pull off COVER (2). Fig. 3b  
WASTE  
4-1/4"  
(108mm)  
ENCLOSURE  
MOUNTING  
HOLES  
4. Remove MIXING VALVE (7) from ENCLOSURE (3).  
Fig. 3b  
MOUNTING HOLES  
5. Install MIXER ENCLOSURE (4) under SELECTRONIC  
ENCLOSURE (2) as shown in Fig. (3a). Hold the MIXER  
ENCLOSURE (4) in that location and mark the four  
mounting hole locations as shown. Fig. (3a)  
1-3/16"  
(46mm)  
NOTE: MIXER ENCLOSURE SUPPLY HOSES are  
20" long. Distance between wall valves and MIXER  
ENCLOSURE (4) must be taken into consideration.  
6
4
4
2
7
5
5. The ENCLOSURE (4) works best if secured to a wall  
stud or cross brace within the wall, using the SCREWS  
(5) supplied. If the MIXER ENCLOSURE (4) is to be  
installed on a tile or plaster wall the ANCHORS (6) and  
SCREWS (5) should be used.  
ILLUSTRATION SHOWN  
LESS MIXING VALVE  
6. For installations on drywall or tiled walls; use  
ANCHORS (6) and SCREWS (5) for securing MIXER  
ENCLOSURE (4) to finished wall. Drill four 1/4" dia.  
holes a minimum of 1-3/4" deep. Insert the four  
ANCHORS (6) flush with face of the finished wall.  
Align the MIXER ENCLOSURE (4) and Install the  
MOUNTING SCREWS (5). Tighten to secure MIXER  
ENCLOSURE (4) to mounting surface.  
ADJUSTABLE  
WRENCH  
Fig. 4  
2
Fig. 4a  
2
4
3
CONNECT MIXING VALVE; Fig. 4  
2
1. Install MIXING VALVE (1) back into ENCLOSURE.  
2. Install FIBER SEAL WASHER (4) on MIXING  
VALVE NIPPLE (3). Hold MIXING VALVE (1) in place  
with one hand and with your other hand thread  
SWIVEL NUT (2) onto MIXING VALVE NIPPLE (3).  
Fig. 4. Use an adjustable wrench to tighten SWIVEL  
NUT (2). Fig. 4a  
1
3. Replace ENCLOSURE COVER and tighten securely.  
CONNECT MIXING VALVE TO  
3
Fig. 5  
WATER SUPPLIES; Fig. 5  
1. Turn off hot and cold water supplies before  
beginning.  
2. Connect FLEXIBLE SUPPLIES (1, 2) directly to wall  
supplies. Connection on MIXER supplies are 3/8"  
compression. Connect left supply to Hot and right  
supply to Cold wall supply. Use adjustable wrench to  
tighten connections. Do not over tighten. FIG. 5  
WALL SUPPLIES  
HOT  
COLD  
2
3. Faucet supplies measure 20" from the bottom of the  
ENCLOSURE (3) base.  
1
3
Note: If additional supply length is required, installer  
must purchase parts separately.  
Important: If SUPPLY HOSES (1, 2) are too long, loop  
as to avoid kinking.  
2
 
Fig. 6  
ADJUST TEMPERATURE  
TO DECREASE  
TEMPERATURE  
TO ADJUST TEMPERATURE;  
4
4mm HEX  
WRENCH  
Fig. 6  
1. Adjust temperature by inserting a 4mm Hex Wrench  
into hex opening in the side of enclosure. Fig. 6.  
TO INCREASE  
TEMPERATURE  
2. To decrease temperature, rotate up. (clock-wise)  
3. To increase temperature, rotate down. (counter-  
clockwise)  
Fig. 7  
Fig. 7a  
2
SERVICE  
6, 4  
TO SERVICE CARTRIDGE; Fig; 7  
5
1. Turn off water supply.  
1
5
3
2. Remove MIXING VALVE ENCLOSURE COVER.  
1
3. Disconnect MIXING VALVE (1) from SELECTRONIC  
ENCLOSURE (2). Fig. 7.  
4. Pull MIXING VALVE (1) out from ENCLOSURE (5).  
If SUPPLY HOSES (3) are not long enough to gain  
access to TEMPERATURE CALIBRATION UNIT (6)  
&THERMOSTATIC CARTRIDGE (4) disconnect  
SUPPLY HOSES (3) from wall valves. Fig. 7a.  
Fig. 7b  
Fig. 7c  
6
5. Rotate the BLACK CLAMP (7) with your finger and  
pull off the TEMPERATURE CALIBRATION UNIT (6).  
Fig 7b, 7c.  
6. Use a adjustable wrench to unthread  
THERMOSTATIC CARTRIDGE (4) from housing. Fig. 7d.  
7
7. Remove THERMOSTATIC CARTRIDGE (4). Fig. 7e.  
Fig. 7d  
Fig. 7e  
8. Rinse clean any debris from SCREENS (8) and  
inspect O-RINGS (9) for damage. Replace O-RINGS (9)  
if any damage is found. Fig. 7f.  
4
9. Reverse above steps and reassemble MIXING  
VALVE (1). Assemble MIXING VALVE (1) to  
SELECTRONIC ENCLOSURE (2).  
4
10. Assembly ENCLOSURE COVER and tighten  
securley.  
8
Fig. 7f  
4
9
3
 
SELECTRONIC™  
THERMOSTATIC  
MIXING VALVE  
REPLACEMENT PARTS  
PRODUCT NUMBER  
605XTMV  
A922255-0070A  
ENCLOSURE  
A922256-0070A  
ENCLOSURE COVER  
M962387-0070A  
MOUNTING SCREW &  
ANCHOR KIT  
A954820-0070A  
THERMOSTATIC  
CARTRIDGE  
A918549-0070A  
ENCLOSURE SCREWS  
953957-0070A  
TEMPERATURE  
CALIBRATION UNIT  
A924163-0070A  
SUPPLY HOSES  
HOT LINE FOR HELP  
For toll-free information and answers to your questions, call:  
1 (800) 442-1902  
Weekdays 8:00 a.m. to 8:00 p.m. EST  
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)  
Weekdays 8:00 a.m. to 7:00 p.m. EST  
Product names listed herein are trademarks of American Standard Inc.  
© American Standard Inc. 2005  
M968808  
4
 
M968808  
 

AB Soft Switch N8406 026 User Manual
Acer Personal Computer easyStore H340 User Manual
Agilent Technologies Stereo System 8731A User Manual
Agilent Technologies Weather Radio A1800 User Manual
Agri Fab Spreader 45 03295 User Manual
Air King Fan 2EKZ7 User Manual
Alesis Drums USB Studio Drum Kit User Manual
Allied Telesis Network Card 613 50550 00 User Manual
Alpine Network Card KCA 620M User Manual
Alto Shaam Refrigerator QC 100 User Manual