Axis Communications Security Camera Q6042 E User Manual

AXIS Q60 Series  
AXIS Q6042-E PTZ Dome Network Camera  
AXIS Q6044-E PTZ Dome Network Camera  
AXIS Q6045-E PTZ Dome Network Camera  
Installation Guide  
 
Australia/New Zealand  
Tel: +46 46 272 18 00  
Fax: +46 46 13 61 30  
This digital equipment fulfills the requirements for RF  
emission according to the Class A limit of AS/NZS CISPR 22.  
The product shall be connected using a shielded network  
cable (STP) that is properly grounded. Notice! This is a  
Class A product. In a domestic environment this product  
may cause RF interference, in which case the user may be  
required to take adequate measures.  
Support  
Should you require any technical assistance, please contact  
your Axis reseller. If your questions cannot be answered  
immediately, your reseller will forward your queries through  
the appropriate channels to ensure a rapid response. If you  
are connected to the Internet, you can:  
Japan  
この装置は、クラスA 情  
報技術装置です。この装  
置を家庭環境で使用すると電波妨害 を引き起こす  
ことがあります。この場合には使用者が適切な対  
download user documentation and software updates  
find answers to resolved problems in the FAQ database.  
を講ずるよう要  
求され ることがあります。 本  
Search by product, category, or phrase  
製品  
は、シールドネットワークケーブル(STP)を  
report problems to Axis support staff by logging in to  
使用して接  
続してください。また適切に接  
地し  
your private support area  
てください。  
chat with Axis support staff (selected countries only)  
visit Axis Support at www.axis.com/techsup/  
Korea  
이 기기는 업무용(A급) 전자파적합기기로서 판매  
자 또는 사용자는 이 점을 주의하시기 바라며, 가  
정외의 지역에서 사용하는 것을 목적으로 합니다.  
적절히 접지된 STP (shielded twisted pair) 케이블  
을 사용하여 제품을 연결 하십시오.  
Learn More!  
Visit Axis learning center www.axis.com/academy/ for  
useful trainings, webinars, tutorials and guides.  
Safety  
This product complies with IEC/EN/UL 60950-1 and  
IEC/EN/UL 60950-22, Safety of Information Technology  
Equipment. The product shall be grounded either through a  
shielded network cable (STP) or other appropriate method.  
The power supply used with this product shall fulfill  
the requirements for Safety Extra Low Voltage  
(SELV) and Limited Power Source (LPS) according to  
IEC/EN/UL 60950-1.  
Disposal and Recycling  
When this product has reached the end of its useful life,  
dispose of it according to local laws and regulations. For  
information about your nearest designated collection point,  
contact your local authority responsible for waste disposal.  
In accordance with local legislation, penalties may be  
applicable for incorrect disposal of this waste.  
Europe  
This symbol means that the product shall not be  
disposed of together with household or commercial waste.  
Directive 2012/19/EU on waste electrical and electronic  
equipment (WEEE) is applicable in the European Union  
member states. To prevent potential harm to human health  
and the environment, the product must be disposed of in  
an approved and environmentally safe recycling process.  
For information about your nearest designated collection  
point, contact your local authority responsible for waste  
disposal. Businesses should contact the product supplier for  
information about how to dispose of this product correctly.  
This product complies with the requirements of  
Directive 2011/65/EU on the restriction of the use of  
certain hazardous substances in electrical and electronic  
equipment (RoHS).  
China  
This product complies with the requirements of the  
legislative act Administration on the Control of Pollution  
Caused by Electronic Information Products (ACPEIP).  
Contact Information  
Axis Communications AB  
Emdalavägen 14  
223 69 Lund  
Sweden  
 
     
 
AXIS Q60 Series  
Safety Information  
Read through this Installation Guide carefully before installing the product. Keep the Installation  
Guide for future reference.  
Hazard Levels  
DANGER  
WARNING  
CAUTION  
NOTICE  
Indicates a hazardous situation which, if not avoided, will result in  
death or serious injury.  
Indicates a hazardous situation which, if not avoided, could result  
in death or serious injury.  
Indicates a hazardous situation which, if not avoided, could result  
in minor or moderate injury.  
Indicates a situation which, if not avoided, could result in damage  
to property.  
Other Message Levels  
Important  
Indicates significant information which is essential for the product  
to function correctly.  
Note  
Indicates useful information which helps in getting the most out  
of the product.  
 
5
AXIS Q60 Series  
Safety Instructions  
WARNING  
• The Axis product shall be installed by a trained professional.  
NOTICE  
• The Axis product shall be used in compliance with local laws and regulations.  
• Store the Axis product in a dry and ventilated environment.  
• Avoid exposing the Axis product to shocks or heavy pressure.  
• Do not install the product on unstable brackets, surfaces or walls.  
• Use only applicable tools when installing the Axis product. Excessive force could cause  
damage to the product.  
• Do not use chemicals, caustic agents, or aerosol cleaners. Use a clean cloth dampened  
with pure water for cleaning.  
• Use only accessories that comply with technical specification of the product. These can be  
provided by Axis or a third party.  
• Use only spare parts provided by or recommended by Axis.  
• Do not attempt to repair the product by yourself. Contact Axis support or your Axis  
reseller for service matters.  
Transportation  
NOTICE  
• When transporting the Axis product, use the original packaging or equivalent to prevent  
damage to the product.  
Battery  
The Axis product uses a 3.0 V BR/CR2032 lithium battery as the power supply for its internal  
real-time clock (RTC). Under normal conditions this battery will last for a minimum of five years.  
Low battery power affects the operation of the RTC, causing it to reset at every power-up. When  
the battery needs replacing, a log message will appear in the product’s server report. For more  
information about the server report, see the product´s setup pages or contact Axis support.  
The battery should not be replaced unless required, but if the battery does need replacing, contact  
Axis support at www.axis.com/techsup for assistance.  
 
6
AXIS Q60 Series  
WARNING  
• Risk of explosion if the battery is incorrectly replaced.  
• Replace only with an identical battery or a battery which is recommended by Axis.  
• Dispose of used batteries according to local regulations or the battery manufacturer's  
instructions.  
Dome Cover  
NOTICE  
• Be careful not to scratch, damage or leave fingerprints on the dome cover because this  
could decrease image quality. If possible, keep the protective plastic on the dome cover  
until the installation is complete.  
• Do not clean a dome cover that looks clean to the eye and never polish the surface.  
Excessive cleaning could damage the surface.  
• For general cleaning of the dome cover it is recommended to use a non-abrasive,  
solvent-free neutral soap or detergent mixed with pure water and a soft, clean cloth. Rinse  
well with pure lukewarm water. Dry with a soft, clean cloth to prevent water spotting.  
• Never use harsh detergents, gasoline, benzene or acetone etc. and avoid cleaning the  
dome cover in direct sunlight or at elevated temperatures.  
 
7
 
8
AXIS Q60 Series  
Installation Guide  
This Installation Guide provides instructions for installing AXIS Q6042-E/Q6044-E/Q6045-E PTZ  
Dome Network Camera on your network. For other aspects of using the product, see the User  
Manual available at www.axis.com  
Installation Steps  
1. Make sure the package contents, tools and other materials necessary for the installation  
are in order. See page 9 .  
2. Study the hardware overview. See page 10.  
3. Study the specifications. See page 13.  
4. Install the hardware. See page 14.  
5. Access the product. See page 18.  
Package Contents  
AXIS Q6042-E/Q6044-E/Q6045-E PTZ Dome Network Camera  
Clear dome cover (premounted)  
Sunshield, including screws T20 (3x)  
RJ45 Push-pull Connector (IP66)  
AXIS T8124 High PoE Midspan 1-port (LPS)  
Installation and Management Software CD  
Printed materials  
-
-
-
Installation Guide (this document)  
Extra serial number label (2x)  
AVHS Authentication key  
Recommended Tools  
Torx screwdriver T20  
Torx screwdriver T30  
Phillips screwdriver PH2 – if replacing the dome cover  
Cable shoe pliers  
Diagonal pliers  
 
9
 
AXIS Q60 Series  
Optional Accessories  
AXIS T91A Mounting Accessories  
Smoked dome cover  
RJ45 IP66-rated Cable with Premounted Connector (CAT6) 5 m  
AXIS T8310 Video Surveillance Control Board  
AXIS T90A Illuminators  
Installation Display  
Midspan  
For information about available accessories, see www.axis.com  
Hardware Overview  
1
2
3
4
Hook for safety wire  
Network connector (High PoE)  
Ground screw  
Unit holder (3x)  
 
10  
 
AXIS Q60 Series  
5
6
7
8
9
10  
Part number (P/N) & Serial number (S/N)  
Power button  
Heater  
Control button  
Status LED indicator  
SD card slot (SDHC)  
Dome Cover  
1
2
3
4
5
6
Dome bracket screw PH2 (4x)  
Dome bracket  
Rubber gasket  
Dome ring  
Dome ring screw T30 (4x)  
Dome cover  
 
11  
AXIS Q60 Series  
Sunshield  
1
2
Screw holes  
Holes for unit holders  
LED Indicators  
LED  
Color  
Indication  
Status  
Unlit  
Connection and normal operation  
Steady during startup. Flashes during firmware upgrade.  
Amber  
Amber/red  
Flashes amber/red if network connection is unavailable  
or lost.  
Red  
Flashes red for firmware upgrade failure.  
Green  
Shows steady green for 10 seconds for normal operation  
after restart.  
Midspan LED Indicators  
LED  
Color  
Indication  
Unlit  
No camera connected.  
Port  
Green  
Steady when camera connected, normal operation.  
Green, flashing  
Slow flash when overcurrent or short circuit condition  
on the port.  
 
12  
 
AXIS Q60 Series  
Green, flashing  
Green  
Fast flash when input voltage is out of range or other  
internal error.  
AC  
Steady when AC power input connected.  
Connectors and Buttons  
For specifications and operating conditions, see page 13.  
Specifications  
Operating Conditions  
The Axis product is intended for outdoor use.  
Product  
Classification  
Temperature  
Humidity  
AXIS Q6042-E  
AXIS Q6044-E  
AXIS Q6045-E  
IEC 60721-4-3  
Class 3K3, 3M3  
IEC 60529 IP66  
-50 °C to 50 °C  
(-58 °F to 122 °F)*  
10–100% RH (condensing)  
10–100% RH (condensing)  
10–100% RH (condensing)  
* Arctic Temperature Control enables camera start-up at temperatures as low as -50 °C (-58 °F)  
Power Consumption  
NOTICE  
Use a Safety Extra Low Voltage (SELV) compliant limited power source (LPS) with either  
a rated output power limited to 100 W or a rated output current limited to 5 A. Axis  
recommends using the supplied midspan.  
Product  
High PoE  
High PoE Midspan (supplied)  
AXIS Q6042-E  
AXIS Q6044-E  
AXIS Q6045-E  
Max. 60 W  
100–240 V AC, max. 60 W  
 
13  
 
AXIS Q60 Series  
Install the Hardware  
NOTICE  
• The AXIS product shall be connected using a shielded network cable (STP). All cables  
connecting the product to the midspan shall be shielded (STP) and intended for their  
specific use. Make sure that the midspan is properly grounded. For information about  
regulatory requirements, see Regulatory Information on page 2 .  
• Mount the product with the dome cover facing downward.  
• Be careful not to scratch, damage or leave fingerprints on the dome cover because this  
could decrease image quality. If possible, keep the protective plastic on the dome cover  
until the installation is complete.  
The Axis product can be installed with the cables routed through or along the wall or roof.  
Read all the instructions before installing the product. Some installation steps would benefit from  
being completed together because they require removal of the dome cover.  
A hardware installation can include the following:  
The product is supplied with a clear dome cover (premounted). A smoked dome cover is  
available as an accessory. To replace the dome cover, see page 14.  
A standard or high capacity SD card (not included) can be used to store recordings locally  
in the product. To install an SD card, see page 15.  
To install the product using a compatible bracket from AXIS T91A Mounting Accessories  
(sold separately), see page 15.  
To install the supplied midspan, see page 17.  
Attach the Sunshield  
Attaching the sunshield is optional. The sunshield protects the camera against UV light and helps  
keep the temperature inside the camera down.  
1. Slide the sunshield over the unit holders on the camera unit.  
2. Secure the sunshield using the supplied screws (T20).  
Replace the Dome Cover  
Replacing the dome cover is only necessary if you want to use a smoked dome cover or if the  
dome cover is scratched or damaged. Smoked dome covers and spare clear dome covers can be  
purchased from your Axis reseller.  
1. Loosen the dome ring screws and remove the dome cover.  
2. Remove the dome bracket screws and remove the dome bracket and the dome cover  
from the dome ring.  
 
14  
   
AXIS Q60 Series  
3. Make sure the rubber gasket is fitted correctly on the dome cover.  
4. Align the bulge on the dome cover with one of the logotypes on the dome ring.  
5. Attach the dome bracket and the dome cover to the dome ring and tighten the screws  
(torque 1.2 Nm).  
6. To install an SD card (not included), see Install an SD Card on page 15.  
7. To attach the dome cover to the top cover, align the bulge on the dome cover with the  
heater on the camera unit and tighten the screws (torque 1.5 Nm).  
Install an SD Card  
It is optional to install a standard or high capacity SD card (not included), which can be used for  
local recording with removable storage.  
1. Loosen the dome ring screws and remove the dome cover.  
2. Insert an SD card (not included) into the SD card slot.  
3. To attach the dome cover to the top cover, align the bulge on the dome cover with the  
heater on the camera unit and tighten the screws (torque 1.5 Nm).  
NOTICE  
To prevent corruption of recordings, the SD card should be unmounted before it is ejected.  
To unmount, go to Setup > System Options > Storage > SD Card and click Unmount.  
Bracket Mount (sold separately)  
NOTICE  
• The product shall be grounded using a grounding wire. Make sure both ends of the  
grounding wire are in contact with their respective grounding surfaces.  
• To comply with the IP66-rated design of the camera and maintain the IP66 protection,  
the supplied RJ45 Push-pull Connector (IP66) shall be used. Alternatively, use the RJ45  
IP66-rated cable with premounted connector which is available from your Axis reseller.  
Do not remove the plastic network connector shield from the camera.  
1. Install the selected bracket according to the instructions supplied with the bracket. If  
drilling is required, make sure to use drill bits, screws and plugs that are appropriate for  
the material.  
2. Secure the camera using the supplied safety wire.  
3. Route the network cable and a grounding wire through the holes in the mounting bracket.  
4. Loosen the grounding screw and remove the washer and cable shoe.  
 
15  
   
AXIS Q60 Series  
1
2
3
4
5
Network connector – RJ45 Push-pull Connector (IP66)  
Network connector and network connector shield  
Ground screw T20  
Washer  
Cable shoe  
5. Attach the grounding wire to the cable shoe using cable shoe pliers.  
6. Put the cable shoe and washer back in their original positions and tighten the screw  
(torque 0.5 Nm). Make sure the cable shoe is in contact with the grounding surface.  
7. Connect supplied RJ45 Push-pull Connector (IP66) to the network cable according to the  
instructions supplied with the connector.  
8. Connect the network cable to the camera.  
NOTICE  
Be careful not to damage the network cable when connecting it.  
9. Slide the unit holders on the network camera into the slots in the mounting bracket and  
rotate the camera unit.  
10. Secure the network camera to the mounting bracket by tightening the screws.  
 
16  
AXIS Q60 Series  
1
2
3
4
Screw T30 (3x)  
Slot for unit holder (3x)  
Safety wire  
Wall bracket (mounting example)  
11. Install the supplied midspan. See page 17.  
Install the Midspan  
The supplied midspan enables Axis network video products with high power consumption to receive  
data and power over the same network cable.  
1. Connect the midspan (data in) to the network switch using a network cable.  
2. Connect the midspan (data and power out) to the camera using the network cable that  
has been connected to the camera.  
3. Connect the midspan to a grounded (earthed) mains power outlet (100–240 V AC) using  
the supplied power cable.  
 
17  
 
AXIS Q60 Series  
1
2
3
4
Data and power out (connect to Axis product)  
Data in (connect to network)  
AC input LED indicator  
Port LED indicator  
4. Make sure that the LEDs on the midspan indicate the correct conditions. See Midspan  
LED Indicators on page 12.  
Access the Product  
Use the tools provided on the Installation and Management Software CD to assign an IP address,  
set the password and access the video stream. This information is also available from the support  
Reset to Factory Default Settings  
Important  
Reset to factory default should be used with caution. A reset to factory default will reset  
all settings, including the IP address, to the factory default values.  
Note  
The installation and management software tools are available on the CD supplied with the  
product and from the support pages on www.axis.com/techsup  
To reset the product to the factory default settings:  
1. Press and hold the control button and the power button for about 15–30 seconds until  
the status LED indicator flashes amber. See Hardware Overview on page 10.  
2. Release the control button but continue to hold down the power button until the status  
LED indicator turns green.  
3. Release the power button and assemble the product.  
 
18  
 
AXIS Q60 Series  
4. The process is now complete. The product has been reset to the factory default settings.  
If no DHCP server is available on the network, the default IP address is 192.168.0.90  
5. Using the installation and management software tools, assign an IP address, set the  
password and access the video stream.  
It is also possible to reset parameters to factory default via the web interface. Go to Setup  
> System Options > Maintenance.  
Further Information  
The User Manual is available at www.axis.com  
Visit www.axis.com/techsup to check if there is updated firmware available for your network  
product. To see the currently installed firmware version, go to Setup > About.  
Visit Axis learning center www.axis.com/academy for useful trainings, webinars, tutorials and  
guides.  
Scan the QR code to view a video on how to assemble the supplied RJ45 Push-pull Connector (IP66).  
Warranty Information  
For information about Axis’ product warranty and thereto related information, see  
 
19  
 
Errata  
Valid for AXIS Q6044-E/Q6045-E  
About this document  
This document is a correction of AXIS Q60-E Series Installation Guide AXIS Q6042-E/Q6044-E/Q6045-E.  
page 2  
Regulatory Information  
USA  
This equipment has been tested using an unshielded network cable (UTP) and  
found to comply with the limits for a Class A digital device, pursuant to part  
15 of the FCC rules. This equipment has also been tested using a shielded  
network cable (STP) and found to comply with the limits for a Class A digital  
device, pursuant to part 15 of the FCC rules. These limits are designed to  
provide reasonable protection against harmful interference when the  
equipment is operated in a commercial environment. This equipment  
generates, uses, and can radiate radio frequency energy and, if not installed  
and used in accordance with the instruction manual, may cause harmful  
interference to radio communications. Operation of this equipment in a  
residential area is likely to cause harmful interference in which case the user  
will be required to correct the interference at his own expense.  
page 13  
Network Connector  
Due to local regulations or the environmental and electrical conditions in which  
the product is to be used, a shielded network cable (STP) may be appropriate or  
required. All cables connecting the product to the network and that are routed  
outdoors or in demanding electrical environments shall be intended for their  
specific use. Make sure that the network devices are installed in accordance  
with the manufacturer’s instructions. For information about regulatory  
requirements, see Regulatory Information.  
page 14  
Install the Hardware  
Due to local regulations or the environmental and electrical conditions in which  
the product is to be used, a shielded network cable (STP) may be appropriate or  
required. All cables connecting the product to the network and that are routed  
outdoors or in demanding electrical environments shall be intended for their  
specific use. Make sure that the network devices are installed in accordance  
with the manufacturer’s instructions. For information about  
regulatory requirements, see Regulatory Information.  
Errata, Installation Guide  
AXIS Q60-E Series  
© Axis Communications AB,  
2014  
Date: October 2014  
Part No: 60298  
Part No (original document):  
58978  
 
 
 
Installation Guide  
AXIS Q60 Series  
© Axis Communications AB, 2014  
Ver. M2.7  
Date: July 2014  
Part No. 58978  
 

AEG Washer 70730 User Manual
Agilent Technologies Blood Glucose Meter AN 372 2 User Manual
Agilent Technologies Video Games 60502B User Manual
Agilent Technologies Welding System 08131 90001 User Manual
Aluratek Camera Lens ADMPF210 User Manual
American DJ Indoor Furnishings Multi Star User Manual
American Standard Indoor Furnishings T373700 User Manual
AMX Stereo Receiver UDM RX02 User Manual
Bags and Gloves Network Card E 9220T User Manual
Barco Projector Accessories R9840170 User Manual