BAP725/750CN04M1.qxd 2/26/05 1:36 PM Page 1
Carbon Filter Indicator – When the carbon filter indicator
17.NEVER use detergents, gasoline, glass cleaner, furniture pol-
ish, paint thinner, or other household solvents to clean any
part of the appliance.
AIR PURIFIER SAFETY
light turns yellow, it is time to change the carbon filter.
ENERGY STAR® – This product earned the ENERGY STAR®
by meeting strict energy efficient guidelines set by the US
EPA. The energy efficiency of this ENERGY STAR qualified
model is measured based on a ratio between the model’s
CADR for dust and the electrical energy it consumes, or
CADR/ Watt.
Timer –The timer allows you to run your air purifier at your
convenience, for up to 16 hours. To operate using the timer
mode, at the control panel on the air purifier, turn the unit on
and select a speed. Note: Timer cannot be controlled with
the remote control.
18.Always turn the appliance off before unplugging it.
PLEASE READ AND SAVE
THESE IMPORTANT
SAFEGUARDS
99.97% HEPA
PLEASE READ AND SAVE
THESE INSTRUCTIONS
CONSUMER SAFETY INFORMATION
THIS PRODUCT IS EQUIPPED WITH A POLARIZED AC (Alternating
Current) PLUG (a plug having one blade
wider than the other). This plug will fit into
the power outlet only one way. If the plug
does not fit fully into the outlet, reverse the
plug. If it still does not fit, contact qualified
personnel to install the proper outlet.
Air Purifier
MODEL BAP725
IMPORTANT INSTRUCTIONS
BAP750
When using electrical appliances, basic safety precautions should
always be followed to reduce the risk of fire, electric shock, and injury
to persons, including the following:
1. Read all instructions before using appliance.
2. To avoid fire and shock hazard, plug the appliance directly
into a 120V AC electrical outlet.
3. If the filter is covered by a bag when shipped: remove plastic
bag over filter before use.
4. Keep the cord out of heavy traffic areas. To avoid fire hazard
NEVER put the cord under rugs, near heat registers, radiators,
stoves or heaters.
5. To protect against electrical hazards DO NOT immerse in
water or other liquids. Do not use near water.
6. Close supervision is necessary when any appliance is used
by, or near children or by disabled persons.
To activate the timer, press the "+" and "-" speed buttons at
the same time for approximately 3 seconds.
The numbers in the display will begin flashing and the light will
appear to indicate timer function is on. Push “+” or “-” button
to cycle through the timer options (1- 16). When you have
reached desired hours that you want your air purifier to run,
release finger from the button and the numbers will stop
flashing and timer will be on. The air purifier will then operate
for that period of time and shut off automatically. Speeds can
be changed once the timer is activated by pushing the “+” or
“-“ buttons. To view the time left to run once timer has been
set, push the “+” and “-“ at the same time for 3 seconds. You
can manually turn the air purifier off by pressing the ON/OFF
DO NOT DEFEAT THE SAFETY PURPOSE OF THIS
POLARIZED PLUG IN ANY WAY
The length of the cord used on this product was selected to reduce
the hazards of becoming tangled in, or tripping over a longer cord.
If a longer cord is necessary an approved extension cord may be
used. The electrical rating of the extension cord must be equal to or
greater than the rating of the air purifier. Care must be taken to
arrange the extension cord where it cannot be pulled on by children
or accidentally tripped over.
(
) button once.
BACKGROUND
7. Always unplug the air purifier before moving it, opening the grill,
changing the filters or whenever the air purifier is not in use. Be
sure to pull by the plug and not the cord.
First, thank you for choosing a Bionaire® Air Purifier. The Air Purifier
was created because consumers, like you, provided a lot of feed-
back about what you wanted in an air purifier. With the features con-
sumers want in mind, we worked with sound experts and engineers
to make the unit quieter and smaller, with more advanced technolo-
gies. We designed a patented modular filter system for easier filter
replacement. The result is an air purifier that is in harmony with your
environment--it cleans your air and fits your life.
PRE-OPERATING INSTRUCTIONS
NOTE: The front grill should not be removed when the unit is
on its side.
8. NEVER drop or insert any object into any openings.
1. After removing the unit from the box, take the plastic cov-
ering off the unit and properly dispose of it.
2. Lay the air purifier flat on its back with the front / air intake
grill pointing up.
3. Open the door of the air purifier by carefully placing fingers
in indentation on the right side of the door and gently pull
forward.
4. The carbon filters, which are packed in a plastic bag in the
box, should be removed from plastic bag and then placed on
each of the HEPA filters. The plastic tabs on the HEPA filter will
hold the carbon in place (see Figure 1).
9. Do not operate any appliance with a damaged cord or plug, if
motor fan fails to rotate, after the appliance malfunctions, or if it
has been dropped or damaged in any manner. Return appliance
to manufacturer for examination, electrical or mechanical adjust-
ment or repair.
10.Use appliance only for the intended household use as
described in this manual. Any other use not recommended
by the manufacturer may cause fire, electric shock or injury
to persons. The use of attachments not recommended or
sold by the Holmes Group may cause hazards.
FEATURES
Dual Position- The air purifier can stand upright or lie on its side. Also
designed to fit with its back flush against the wall. When positioning
the unit, please be sure the air inlet grill, filters and air outlet are not
blocked to ensure maximum airflow.
Equipped with
motor – For quieter
11.Do not use outdoors.
performance and the added durability nec-
essary for continuous use.
12.Never block the air openings, or place on soft surface, such
as bed or sofa, as this could cause the unit to tip over thus
blocking the air intake opening.
5. Replace the front grill by aligning tab on left hand side and
swinging down. Gently press until front grill is firmly in place.
Filter Window – On the front grill, there
is a small opening that will enable you
to see your carbon filter at a glance. As
it picks up dust and debris, the window
will turn to gray indicating the air purifi-
Read instructions before operating.
Retain for future reference.
OPERATING INSTRUCTIONS
1. Select location where air intake grill and filtered air outlet
are not obstructed.
13.Keep unit away from heated surfaces and open flames.
14.DO NOT attempt to repair or adjust any electrical or mechan-
ical functions on this unit. Doing so will void your warranty.
The inside of the unit contains no user serviceable parts. All
servicing should be performed by qualified personnel only.
15.WARNING: To reduce the risk of fire or electrical shock, DO NOT
use this air purifier with any solid-state speed control device.
BAP725 shown
Instruction Leaflet
2. Plug into a 120V AC electrical outlet.
er is working and you may need to change
the carbon filters.
3. The air purifier is now ready for use. Turn the unit on by press-
IN FO-LIN E
☎
ing the (
) button. Set the air purifier to the desired speed
If after having read this leaflet, you have any
HEPA Filter Indicator – When the HEPA fil-
ter is approaching the end of its useful life,
the indicator light will turn red. When the red indicator light starts
flashing, it is time to change the HEPA filter.
setting; High (4), Medium (3), Low (2) or Sleep (1) by pushing
the "+" or "-" buttons on the control panel. (ON will automat-
ically cycle to the highest setting.)
questions or com m ents on your Air Purifier,
call 1-8 0 0 -2 5 3 -2 7 6 4 in North Am erica.
16.DO NOT place anything on top of the unit.
For continuous use, it’s recommended to operate the air purifier at
the MEDIUM setting. For quieter operation or use in a bedroom,
select the LOW or Sleep setting. When high levels of air pollution
are present, select the HIGH setting to quickly circulate and filter
the room air.
WARRANTY
Figure 2
Figure 1
B
The manufacturer warrants to the original retail purchaser for TWO
(2) YEARS from the date of original purchase, either to repair or
replace at its option, without charge (parts and labor), any supplied
or manufactured part of this air purifier which, upon inspection by
an authorized service center, proves to have failed in normal use
due to defects in material or workmanship, or, at its option, to
replace the unit.
FILTER REPLACEMENT INSTRUCTIONS
C
A
1. On average, HEPA filters need to be replaced every 12-18
months. Carbon filters need to be replaced every 3-6
months. Filter life will vary depending on air quality and
usage.
2. Turn off and unplug the air purifier before attempting to
replace the filters.
3. Remove each of the filters from the unit by pulling gently
towards you.
4. To replace the carbon filter, simply remove the old carbon
filter and insert a new carbon filter in its place after first
removing the plastic bag. Using the plastic tabs as a guid-
line (see figure 1).
A. HEPA FILTER
B. CARBON FILTER
C. HANG TABS
D. AIR INTAKE GRILL
E. FILTERED AIR
OUTLET
F. SPEED CONTROL
G. FILTER LIFE
INDICATOR
Figure 3
E
F
G
Operation under conditions other than those recommended or at
voltages other than the voltage indicated on the unit, or any
attempts by unauthorized personnel to service the unit or modify
it, will render the guarantee void.
D
The manufacturer shall not be liable for any personal injury,
property damage or any incidental or consequential damages of
any kind, resulting from defects, malfunctions, misuse, improper
installation or alteration of the product.
TROUBLESHOOTING
PROBLEM
THE MANUFACTURER EXPRESSLY DISCLAIMS ALL
RESPONSIBILITY FOR CONSEQUENTIAL
DAMAGES OR INCIDENTAL LOSSES CAUSED
BY USE OF THIS PRODUCT.
5. To replace the HEPA filter, discard the old HEPA filters. DO NOT
attempt to clean. Put the carbon filter back on the new HEPA
filter. Insert the new A1230H HEPA filter into the unit, by sliding
it onto the hang tabs (see figure 2).
SOLUTION
Unit will not operate
• Check to make sure unit is properly plugged in.
• Check to make sure the unit is on by pressing the ON/OFF button.
• If the front grill is not on properly, the unit will not operate. Make sure the
filters are properly installed and make sure front grill is seated correctly.
• If the HEPA Filter Life Indicator is red, the HEPA filters need to be changed.
• If the filters have not been changed in a year or more, change the HEPA
filters.
• Check to ensure nothing is blocking air inlet and filtered air outlet.
• Be sure the plastic bag has been removed from the carbon filter.
• If the carbon filter life indicator is yellow, the carbon filters need
to be changed.
6. After replacing the filters, RESET the Filter Life Indicator by
inserting a small object (such as a paper clip) into
the hole below the filter change light marked
RESET. The red LED is the HEPA filter light and
the yellow LED is the carbon filter light.
The provisions of this warranty are in addition to, and not a
modification of, or subtraction from the statutory warranties and
other rights and remedies contained in any applicable legislation and
to the extent that any such provision purports to disclaim, exclude
or limit any such statutory warranties or other rights or remedies,
such provisions shall be deemed to be amended to the extent
necessary to comply therewith.
Decreased air flow
REPLACEMENT FILTERS ARE AS FOLLOWS:
A1230HM HEPA Filter
A1230H HEPA Filter (2 pack)
A1260 Carbon Filter
These filters can be purchased at a retailer near you or by call-
ing 1-800-253-2764.
FOR WARRANTY SERVICE, PLEASE CALL 1-800-253-2764
IN NORTH AMERICA.
A Bionaire® consumer service representative will help determine
which is the best procedure in order for your air purifier to be
repaired.
• Ensure carbon filters are changed every 3-6 months.
AIR PURIFIER SERVICE INSTRUCTIONS
NOTE: Carbon and HEPA Filters are not washable and should
be replaced at the recommended intervals.
1. DO NOT attempt to repair or adjust any electrical or mechan-
ical functions on this unit. Doing so will void the warranty. The
inside of the unit contains no user serviceable parts. All serv-
icing should be performed by qualified personnel only.
2. If you need to exchange the unit, please return it in its origi-
nal carton, with a sales receipt, to the store where you pur-
chased it. If you are returning the unit more than 30 days after
the date of purchase, please see the enclosed warranty.
CLEANING/MAINTENANCE INSTRUCTIONS
1. Turn the air purifier off and unplug it before cleaning.
2. The outside of the air purifier can be cleaned with a soft, clean
damp cloth.
3. The filtered air outlet / top air vent can be cleaned of dust with
a small, soft brush.
4. DO NOT wash filters.
5. If you wish to clean the inside of the air purifier, please remove
filters and only use a dry, soft cloth to wipe it down.
WARNING: Do not allow moisture to come in contact with the
main housing of the air purifier.
KEEP THIS NUMBER FOR FUTURE REFERENCE
3. Should your Air Purifier require service, please call
1-800-253-2764 in North America for further assistance. A
return authorization will be given when you call.
4. If you have any other questions or comments, feel free to
Bionaire® and the Bionaire logo® are trademarks of The Holmes Group, Inc. or
its subsidiary.
write to us: Visit our website at www.bionaire.com
MD
GE® is a registered trademark of The General Electric Company, and is used
under the license to The Holmes Group, Inc.
Consumer Service Department
32B Spur Drive
El Paso, TX 79906
Printed in China
|