COOLMOISTURE
hum id ifie r
MODEL BCM1855
Read instructions before operating. Retain for future reference.
Instruction Leaflet
IN FO-LIN E
☎
If after having read this leaflet, you have any questions
or com m ents on your hum idifier,
call 1-8 0 0 -7 8 8 -5 3 5 0 in North Am erica.
428-0161
HUMIDIFIER SAFETY
PLEASE READ AND SAVE
THESE IMPORTANT SAFETY
INSTRUCTIONS.
IMPORTANT SAFEGUARDS
When using electrical appliances, basic safety precautions should
always be followed to reduce the risk of fire, electric shock, and injury
to persons, including the following:
1. Read all instructions before using the appliance.
2. To avoid fire or shock hazard, plug the appliance
directly into a 120 V AC electrical outlet.
3. Keep the cord out of heavy traffic areas. To avoid
fire hazard, NEVER put the cord under rugs, near
heat registers, radiator, stoves, or heaters.
4. DO NOT place humidifier near heat sources such as stoves,
radiators, and heaters. Do locate your humidifier on an inside
wall near an electrical outlet. The humidifier should be at least
4" away from the wall for best results.
5. NEVER place humidifier in an area where it is accessible to children.
NEVER use humidifier in a closed room, particularly where a child
may be sleeping, resting, or playing (a closed room may result in
excessive humidity).
6. WARNING: Do not attempt to refill humidifier without first
unplugging the unit from it’s electrical outlet. Failure to
heed this warning may cause personal injury. Be sure
to pull the plug and not the cord.
7. Never place anything over moisture outlet when
the unit is running.
8. NEVER drop or insert any object into any openings.
9. DO NOT operate any appliance with a damaged cord or plug,
after the appliance malfunctions, or if it has been dropped
or damaged in any manner. Return appliance to manufacturer
for examination, electrical or mechanical adjustment, or repair.
10. Use appliance only for intended household use as described in
this manual. Any other use not recommended by the manufacturer
may cause fire, electric shock, or injury to persons. The use
®
of attachments not recommended or sold by Bionaire or
The Holmes Group, Inc. may cause hazards.
11. DO NOT use outdoors.
12. Always place humidifier on a firm, flat, level surface.
A waterproof mat or pad is recommended for under
the humidifier. NEVER place it on a rug or carpet,
or on a finished floor that may be damaged by
exposure to water or moisture.
13. DO NOT allow the Moisture Outlet to directly face
the wall. Moisture could cause damage, particularly
to wallpaper.
14. Humidifier should be unplugged when not in use.
2
15. NEVER tilt, move, or attempt to empty unit while it is operating.
Shut off and unplug before removing the water tank and moving
the unit.
16. This humidifier requires daily and weekly maintenance
to operate appropriately. Refer to daily and weekly cleaning
procedures.
17. NEVER use detergents, gasoline, glass cleaner, furniture polish,
paint thinner, or other household solvents to clean any part of
the humidifier.
18. Excessive humidity in a room can cause water condensation
on windows and some furniture. If this happens, turn the
humidifier OFF.
19. Do not use humidifier in an area where humidity level
is in excess of 50%. Use a hygrometer, such as Bionaire’s
BT400 or BT254, to measure the humidity.
20. DO NOT attempt to repair or adjust any electrical or mechanical
functions on this unit. Doing so will void your warranty. The inside
of the unit contains no user serviceable parts. All servicing should
be performed by qualified personnel only.
21. Never place housing under water flow or immerse in liquids.
22. Do not plug in the cord with wet hands: electric shock could result.
23. Do not pour water in any openings other than the water tank.
24. To prevent damage to surfaces, do not place humidifier under
overhanging surfaces.
PLEASE SAVE THESE
INSTRUCTIONS.
CONSUMER SAFETY INFORMATION
Note: This is an electrical appliance and requires attention when in use.
Note: If moisture forms on the walls or windows of the room, turn off
the humidifier. The room already has plenty of humidity and additional
moisture may cause damage. Do not block air inlet or outlet.
CORD AND PLUG INSTALLATION SAFETY
INSTRUCTIONS
The length of cord used on this appliance was selected to reduce
the hazards of becoming tangled
in, or tripping over a longer cord.
If a longer cord is necessary an
approved extension cord may be
used. The electrical rating of the
extension cord must be equal to
or greater than the rating of
the humidifier. Care must be taken to arrange the extension cord so
that it will not drape over the countertop or tabletop where it can be
pulled on by children or accidentally tripped over.
HOW COOL MIST WORKS
®
Your Bionaire Cool Mist humidifier draws dry air through the rear
3
air intake grill area. This air is then passed through a moisture-laden
wick filter, which retains the minerals and deposits in the water. The
resulting moist air is directed back into the room from the top air grill.
Tip: This humidification system provides a cool, invisible moisture
☎☎
output. It is normal not to see the mist.
Tip: A humidity level below 20% can be unhealthy and
☎☎
uncomfortable. The recommended humidity level is
between 40%-50%.
Figure 1
A
G
B
H
C
D
E
A. Humidifier Tank
B. Carry Handle
C. Humidifier Housing
D. AccuSet™ Controls
E. Humidifier Base
F
F. Filter Support
G. AccuSet™ Digital Display
H. Filter Check™ Indicator
PRE-OPERATING INSTRUCTIONS
1.Be sure the humidifier is OFF and disconnected from the
electrical outlet.
2.Select a location for your humidifier, on a flat surface, about
4" away from the wall. Do not place your humidifier on furniture;
a floor location that will not be damaged by moisture is best.
3.Remove the water tank by holding the tank handle and lifting
straight upward (see Figure 1).
4.Remove the main housing by lifting straight upward. Check
to see that the wick filter is properly in place. Replace the
humidifier housing.
FILLING THE WATER TANK
NOTE: This humidifier holds about 2.25 gallons of water in the tank
and humidifier base. The humidifier will produce up to 4 gallons of
moisture over a 24-Hour period, depending on the room humidity
and temperature.
1.Be sure the humidifier is OFF and disconnected from
the electrical outlet.
4
2.Remove the tank from the base by holding the handle
and lifting straight up (see Figure 1).
3. Twist off the tank cap located on the bottom of the tank by turning
counter clockwise and fill the water tank with cool, fresh water.
Do not fill with warm water as this may cause leaking.
4. After filling the tank, replace the tank cap by firmly turning
clockwise and then replace the water tank on the base.
The tank will immediately begin to empty into the base.
5. Plug the power cord into a 120V AC electrical outlet.
OPERATING INSTRUCTIONS
1. The unit display will turn on when you plug the power cord
into the electrical outlet.
2. Once the unit is plugged in the digital display will show the current
room humidity (on the left of the display) and the last set humidity
level (on the right of the display).
3. To turn the humidifier on press the power button once. To adjust
the humidifier speed, press the MODE button. The humidifier will
start at HI then go to MEDIUM, LO and then the AUTO speeds (HI,
MEDIUM, LO). The humidifier will start in the last set speed unless
the humidifier has been unplugged.
Note: If condensation forms on your windows or walls, or your
humidity % on your display reads above 50% then turn the unit off.
When the tank runs out of water push the POWER button OFF and
unplug. Remove and refill the water tank as instructed, being sure
to follow the Daily maintenance instructions. Replace the tank into
the base.
NOTE: If moisture forms on the walls or windows, turn off
the humidifier.
SETTING THE ACCUSET, PROGRAMMABLE
HUMIDISTAT:
Follow the Pre-Operating instructions.
The programmable humidistat is designed to operate between
30% and 65% relative humidity range. The recommended setting
is between 40% and 50%.
1. To program a pre-set humidity level, press the MODE button
until the AUTO speeds are displayed, beginning with AUTO HIGH.
Choose your desired Auto speed setting.
2. Once you have chosen your Auto speed, choose your humidity
setting by pressing the HUMIDITY SET button. The HUMIDITY
SET button works in multiples of 5, beginning with lowest
setting, 30% and ending with highest setting, 65%.
5
Choose the appropriate setting and your AccuSet™ humidistat
is now programmed.
NOTE: When the humidity level in the room is less than the humidity
level you have programmed, the humidifier will continue to produce
moisture. Once the room pre-set humidity level is met, the humidifier
will stop producing moisture
REPLACING THE WICK FILTER
Figure 2
Through normal use, waterborne minerals and
sediment become trapped in the wick filter.
The harder your water, the greater the amount
of minerals in the water, and the more often
you will need to change your filter.
You will be able to monitor the life of the filter in your humidifier
by checking the Filter Check™ Indicator. When the unit is off,
the Filter Check™ Indicator will read in the OFF position. After 60
minutes of use, Filter Check™ Indicator (refer to Figure 2 for close-up
of indicator) will move from the OFF position and indicate your filter
condition. A brand new filter will register in the section reading GOOD
filter. After frequent use of your humidifier, the Filter Check™ Indicator
will let you know when the filter needs to be changed.
When the needle is in the CHANGE section, this means the
proper amount of moisture is not getting into your air due to the
excessive minerals and sediment that have become trapped on
your filter. At this point, you should replace your filter. It is important
to change your filter as indicated to obtain stated performance level.
To replace the filter, follow the steps below.
1. Be sure the humidifier is switched OFF and disconnected
from the electrical outlet.
2. Remove the tank and main housing to access the base tray.
3. Discard the old filter and follow weekly cleaning instructions.
4. Insert a new filter into the filter support in the base.
5. Replace the main housing and then the tank.
6. Repeat Operating Instruction steps.
It will take about 30 minutes for the humidifier to reach maximum
output. You can obtain a new filter by calling 1-800-788-5350 in
the USA or Canada or by visiting your nearest retailer or authorized
service center. This humidifier takes model BWF65 replacement filter.
Figure 3
A. Circular Filter Supports
B. Circular Extended Life Filter
C. Humidifier Base
B
A
C
6
STORAGE INSTRUCTIONS
If your humidifier will not be in use for two days or more, or at the
end of the season follow these instructions.
1. Clean and dry the humidifier thoroughly as per the Weekly
Maintenance instructions above.
2. Let the humidifier dry completely before storing.
Do not store with water inside the base.
3. Do not store with the reservoir cap in place.
4. Throw away the wicking filter. Do not store with wick filter in place.
5. Store in a cool dry location.
CLEANING AND MAINTENANCE INSTRUCTIONS
Humidifiers provide comfort by adding moisture to dry indoor air.
To get the most of the benefit from the humidifier and avoid product
failure, follow all maintenance instructions carefully. If the recommended
care and maintenance guidelines are not followed, micro-organisms
may be able to grow in the water within the humidifier.
Daily Maintenance
1. Before cleaning, turn the power to OFF and unplug the unit from the
electrical outlet.
2. Lift off the tank and the housing of the humidifier.
3. Carry the base and the tank to the sink, remove the wick filter, place
in sink, then drain and rinse the base and tank thoroughly to remove
any sediment and dirt. Wipe clean and dry with a clean soft cloth
or paper towel (DO NOT use metal cleaning utensils or abrasive
cleaners).
4. Put the filter back in the filter supports, relace the housing, then refill
the tank with cool tap water as instructed in filling the water tank
instructions.
Weekly Maintenance
Remove scale:
1. Repeat steps 1-3 above.
2. Clean the base by partially filling the base with one 8-oz cup
of undiluted white vinegar, or by using Clean-Away® solution.
Let solution stand 20 minutes, clean all interior surfaces with
a soft brush.
3. Dampen a cloth with undiluted white vinegar and wipe out
entire base to remove scale.
4. Rinse with clean warm water to remove scale and the
white vinegar solution before beginning to disinfect the tank.
Disinfect tank:
1. Fill tank with 1/2 teaspoon of chlorine bleach and 1/2 gallon
of water.
2. Let the solution stand for 20 minutes, swishing every few
minutes. Wet all surfaces.
7
3. Empty the tank after 20 minutes, and rinse well with water until
the bleach smell is gone. Dry with a clean cloth or paper towel.
4. Refill the water tank with cool water; replace the housing
and the water tank. Repeat ALL Operating Instructions.
Troubleshooting for your Cool Mist Humidifier
Probable Cause
☎ Unit not plugged in.
☎ Power failure.
Trouble
• Power light not illuminated.
Solution
☎ Plug in unit.
☎ Check circuit breaker or
outlet.
☎ Filter has not
absorbed water.
• Mist output minimal to
none.
☎☎ Wait 15 minutes before
starting humidifier.
☎ Mineral buildup in base.
☎ Regular cleaning of tray
after each use will help
keep the unit functioning
properly.
☎ Humidistat is set too low.
☎ Set the humidistat to
high.
☎ Wick Filter needs
to be replaced.
☎☎ Replace your wick filter
(BWF65) by calling
1-800-788-5350 or visit
☎ Mist is invisible.
☎ Normal operation.
☎ Check to see if inlet or
outlet grills are blocked
☎ Rubber tank ring is
missing or improperly
placed.
☎ Cap not
tight enough.
• Water leaks from tank
• Filter turns brown.
☎☎ Remove tank
cap then replace
or reposition ring.
☎ Tighten the cap.
☎☎ Replace your wick filter
(BWF65) by calling
☎ Your filter needs
to be changed.
1-800-788-5350 or visit
☎ In areas with particular
hard water your wick
filter will need to be
☎ Short filter life.
☎ Mineral deposits cause
changed frequently.
film on tank to build up.
• Film on tank.
• Water cloudy.
☎ Use Clean-Away
Solution (DMS216),
to order call
1-800-788-5350 or
☎ Mineral deposits cause
film on tank to buildup.
☎ Replace your wick filter
(BWF65) by calling
☎ Filter needs to be
changed.
1-800-788-5350 or visit
☎ Using warm water to refill
☎ Refill using cool water.
tank.
• Humidistat cycles on/off.
• Very tight reservoir cap.
☎ Set the humidistat to a
higher or lower setting.
☎ Humidifier is reacting
to room humidity level.
☎ Add liquid soap or
pertroeum jelly to cap
gasket to ease opening.
☎ Over tightened.
8
SERVICE INSTRUCTIONS
1. Do NOT attempt to repair or adjust any mechanical functions on
this unit. Doing so will void the warranty. The inside of the unit
contains no user serviceable parts. All servicing should be
performed by qualified personnel only.
2. If you need to exchange the unit, please return it in its original car-
ton, with a sales receipt, to the store where you purchased it. If you
are returning the unit more than 30 days after the date of purchase,
please see the enclosed warranty.
3. Should your humidifier require service, please call
1-800-788-5350 in North America for further assistance.
4.
If you have any other questions or comments, feel free to write
*
to us or visit our website www.bionaire.com
PO Box 400
Milford, MA 01757
USA
Canada
6385 Shawson Drive
Mississaugua, Ontario
Canada, L5T 1S7
9
SIX (6) YEAR LIMITED WARRANTY
WARRANTY
The quality controls used in the manufacture of this Bionaire® product are to
ensure your satisfaction. This Warranty applies only to the original purchaser
of this product. This Warranty applies ONLY to repair or replacement of any
supplied or manufactured parts of this product that, upon inspection by Bionaire®
authorized personnel, proves to have failed in normal use due to defects in
material or workmanship. Bionaire® will determine whether to repair or replace
the unit. This Warranty does not apply to installation expenses. Operating this
unit under conditions other than those recommended or at voltages other than
the voltage indicated on the unit, or attempting to service or modify the unit,
will render this WARRANTY VOID. Unless otherwise proscribed by law,
Bionaire® shall not be liable for any personal injury, property or any incidental
or consequential damages of any kind (including water damage) resulting from
malfunctions, defects, misuse, improper installation or alteration of this product.
All parts of this Bionaire® product are guaranteed for a period of 6 years as
follows:
1. Within the first 30 days from date of purchase, the store from which you
purchased your Bionaire® product should replace this product if it is defective
in material or workmanship (provided the store has in-stock replacement).
2. Within the first seventy two months from date of purchase, subject to the
conditions in paragraph H, Bionaire® will repair or replace the product if it is
defective in material or workmanship providing it is returned to Bionaire®, freight
prepaid, with PROOF OF PURCHASE date, together with $8.00 for handling
and return packing/shipping charges. If you have any problem with this product,
please write our Consumer Service Dept., or call, 1-800-788-5350.
IMPORTANT RETURN INSTRUCTIONS: Your warranty depends on your following
these instructions if you are returning the unit more than 30 days after the date of
purchase:
1. Carefully pack the item in its original carton or other suitable box to avoid
damage in shipping.
2. Before packing your unit for return; be sure to enclose:
a) Your name, full address with zip code and telephone number,
b) A dated sales receipt or PROOF OF PURCHASE,
c) Your $8.00 check for return packaging, and
d) The model number of the unit and the problem you are having. (Enclose
in an envelope and tape directly to the unit before the box is sealed).
3. Bionaire® recommends you insure the package (as damage in shipment is not
covered by your warranty).
4. All shipping charges must be prepaid by you (as noted in paragraph F).
SHIPPING AND HANDLING CHARGES:
$8.00
This warranty gives you specific legal rights, and you may have other rights
which vary from state to state. The provisions of this warranty are in addition to,
and not a modification of, or subtraction from, the statutory warranties and other
rights and remedies contained in any applicable legislation. To the extent that any
provision of this warranty is inconsistent with any applicable law, such provision
shall be deemed voided or amended, as necessary, to comply with such law.
10
|