Specifications
Cranking Rating: 10 sec.
Cranking Rating: 1 min.
2,000 Amperes DC
1,000 Amperes DC
Marine Electrical Products
Intermittent Rating: 5 min. (UL 1107) 600 Amperes DC
Continuous Rating: (UL 1107)
Terminal Stud, Tin-Plated Copper
Torque
Cable Size to Meet Ratings*
Maximum Voltage Rating
Ignition Protected
350 Amperes DC
3/8"-16 (M10)
140 in-lb (15.82 N·m)
4/0 AWG (120 mm²)
32 Volts DC
e-Series Selector Battery Switch
PN 9001e
marked
Agency Specifications
• Meets all American Boat and Yacht Council (ABYC) requirements for
battery switches
• UL Listed - UL 1107 for electric power switches
• Meets UL 1500 and SAE J1171 external ignition protection requirements
Features
• Selects battery bank 1 or battery bank 2, or 1+2 for charging or
emergency starting
Guarantee
Any Blue Sea Systems product with which a customer is not satisfied may be
returned for a refund or replacement at any time.
• For switching battery banks in applications requiring high power output,
reliability, and low heat generation
Tin-plated copper studs:
• 3/8"-16 (M10) provide maximum conductivity and corrosion resistance
• One-piece to reduce risk of overheating
For information about Blue Sea Systems Engine Starting Standard, go to
• 7/8" (22.22mm) length to accept multiple cable terminals
* Reducing cable sizes will reduce current ratings
Case design:
• Allows surface mounting or rear panel mounting
• Accepts up to 4/0 AWG (120 mm²) battery cables
Blue Sea Systems Inc.
425 Sequoia Drive
Phone (360) 738-8230
Fax (360) 734-4195
Bellingham, WA 98226 USA
E-mail [email protected]
Caution
• Disconnect positive battery terminal before installing.
• Débranchez la cosse positive de la batterie avant de l’installer.
• Desconecte el terminal positivo de la batería antes de la instalación.
• Prima di eseguire l’installazione, disconnettere il terminale positivo della batteria.
• Consult marine electrical professional for proper wiring application.
• Consultez un professionnel de l’électricité marine pour installer le câblage correctement.
• Consulte a un electricista marino profesional para la aplicación de alambrado apropiada.
• Per assicurarsi che i cavi siano correttamente collegati, rivolgersi ad un elettricista specializzato in motori marini.
Installation
• Mount in an easily accessible location close to the batteries.
• Montez-le dans un endroit facilement accessible près des batteries.
• Monte en una ubicación fácilmente accesible cerca de la batería.
• Montare in un punto facilmente accessibile e vicino alle batterie.
• Attach one 4/0 AWG cable per terminal to meet ratings.
• Raccordez un câble 95mm² par cosse pour respecter les spécifications.
• Sujete un cable 95mm² por terminal de acuerdo a la clasificación.
• Attaccare un cavo 95mm² per conformarsi alle tarature.
• Refer to the latest edition of NFPA 302 and/or ABYC E11 Standard for installation information.
• Battery cable terminals must be attached under nut and lock washer. Torque 140 in-lb (15.82 N·m).
• Les cosses des câbles de batterie doivent être fixées sous la rondelle de sûreté et l’écrou – couple de serrage de 15,82 N·m (140 lb-po).
• Los terminales de los cables de batería deberán ser sujetados debajo de la tuerca y la arandela. Apriételos a una torsión de 15,82 N·m (140 lbs-pul).
• I terminali del cavo della batteria vanno attaccati con un dado e una rondella elastica: coppia di 15,82 N·m (140 lbs-in).
Operation
• Turn all appliances off before turning the battery switch to OFF.
• Éteignez tous les appareils électriques avant de mettre l’interrupteur de batterie sur ARRÊT.
• Apague todos los artefactos antes de girar el interruptor de batería a APAGADO (OFF).
• Spegnere tutte le apparecchiature prima di muovere l’interruttore della batteria su OFF (spento).
• Do not switch to OFF while engine is running.
• Ne le mettez pas sur ARRÊT alors que le moteur tourne.
• No coloque el interruptor en APAGADO (OFF) mientras que el motor esté funcionando.
• Non muovere l’interruttore su OFF (spento) quando il motore è in moto.
|