Using your Extractor  
For best performance, you should switch on the extractor 15 minutes before starting  
to cook and leave it to run for approximately 15 minutes after the end of cooking.  
To switch on the extractor and set the speed level  
A
Touch key A. The appliance will switch on at the first speed level.  
To increase the speed level touch key B. The speed cycles through first, second  
and third speed levels, and the relevant number indicator will show on the  
centre of the display.  
B
C
To switch the extractor off, touch key A.  
The extractor lights  
To switch the lights on touch key D. The extractor lights will cycle through  
three light settings (high, medium, low, off) with each touch of the key. The  
light indicator will show on the centre of the display when the lights are on.  
D
The intensive function  
The extractor is equipped with an intensive function which runs for ten  
minutes before returning to the previous selected speed level.  
To activate the intensive function, touch and hold key B at any speed level for  
approximately five seconds. The 3 indicator on the centre of the display will  
flash whilst the intensive function is on.  
E
To cancel the intensive function, touch the speed level key and the extractor  
will return to the previous speed level.  
The timer  
The extractor is equipped with a timer that allows the extractor to run for 15  
minutes before switching off automatically.  
To activate the timer, touch key E. The timer indicator will show on the centre  
of the display when the timer is on.  
Control Panel  
A – Power key  
B – Speed level key  
C – Light indicator  
D - Light key  
Please note  
The timer cannot be activated when the intensive function is on.  
E – Timer key  
The clean air function  
The extractor is equipped with a clean air function that switches on the motor  
for ten minutes every hour at speed level one.  
Fig. 1  
To activate the clean air function, touch key A for five seconds when the  
appliance is off. When the motor is running, the light indicator will flash and  
the first speed indicator will light up. For the remaining 50 minutes, the light  
indicator will flash.  
To cancel the clean air function, touch any key except the light key.  
The ambient light function  
The extractor is equipped with an ambient light function that switches on the  
LED lights on the side of the extractor.  
To switch the ambient light function on or off, touch and hold the timer  
button for approximately five seconds  
2
 
Using your Remote Control  
Synchronising your remote with the extractor  
1. Whilst the appliance is off, touch the light key on the extractor for  
approximately five seconds until the indicator light begins to flash, as  
shown in figure 2.  
2. Turn the top section of the remote control until the indicator light on  
the extractor stops flashing.  
Fig. 2  
In the event of any problems, repeat the steps above.  
To set the motor speed  
Turn the top section of the remote control so the indicator is at the required  
speed level, as shown in figure 3.  
Fig. 3  
To select the intensive speed level, press the remote control in for two  
seconds at positions one, two or three, as shown in figure 4.  
To turn on the light  
Press the remote control in to switch on the light to the highest level, as  
shown in figure 5.  
2 sec.  
To cycle through the light settings (high, medium, low, off) press the remote  
control in repeatedly.  
Fig. 4  
To change the battery  
The battery will last for approximately 12 months, depending on usage.  
To change the battery, remove the lid from the remote control, as shown in  
figure 6.  
Then remove the battery by applying pressure to the edge, as shown in  
figure 7.  
Replace with a 3 Volt 5004LC / CR 2032 battery.  
Fig. 5  
Please note:  
The remote control will work up to five metres away from the extractor.  
The base of the remote control is magnetic so can be attached to ferrous surfaces.  
Fig. 6  
Fig. 7  
3
 
Care and Maintenance  
IMPORTANT : DO NOT PERFORM MAINTENANCE OR CLEANING OF THE  
EXTRACTOR WITHOUT FIRST SWITCHING OFF THE ELECTRICITY SUPPLY.  
Cleaning  
You should use a nonabrasive cleaner. Any abrasive cleaner (including Cif) will  
scratch the surface and could erase the control panel markings.  
2
1
You can clean your extractor effectively by simply using a dilute solution of water  
and mild detergent and drying to a shine with a clean cloth.  
3
Cleaning the grease filter  
The grease filter should be kept clean to minimise the risk of fire.  
Fig. 8  
After 30 hours of use, the filters indicator light will switch on to indicate that the  
grease filters must be washed. you should remove and clean the grease filter with  
hot soapy water. You can also wash the grease filter in a dishwasher, ensuring that  
you place it in an upright position to prevent damage from other items in the  
dishwasher. After rinsing and drying, replace the filter. After the grease filter has  
been replaced, the electronic memory must be reset by touching the speed level  
key for approximately five seconds, until the filters indicator light switches off.  
1
To remove the grease filter follow the steps below:  
Pull open the handle on the grease filter as shown in fig. 8. It will release at  
the handle side. Then lower the grease filter to remove it completely.  
2
Y
To replace the grease filter, repeat the steps in reverse.  
Fig. 9  
Please note:  
Cleaning the grease filter in the dishwasher may lead to discolouration. This is  
normal and does not constitute a fault with the appliance.  
Changing the charcoal filter  
After 120 hours of use, the filters indicator light will flash to indicate that the  
charcoal filters must be replaced. After the charcoal filter has been replaced,  
the electronic memory must be reset by touching kthe speed level key for  
approximately five seconds, until the filters indicator light switches off.  
To replace the charcoal filter, rst open the base of the extractor and remove the  
grease filter as shown in figures 8 and 9. To remove the charcoal filter as shown in  
figure 9 and replace it with a new charcoal filter. Finally, replace the grease filter and  
then close the extractor base.  
4
 
Replacing the main halogen  
down lights:  
1. Lower the lamp panel (G) and unscrew the 4 lamp  
housing fixing screws (F) to access the bulb covers.  
4
2. Carefully prise off the bulb covers using a small  
screwdriver and refit the new bulb taking care not  
to touch the glass of the bulb (Fingerprints will lead to  
premature failure of the bulb)  
B
C
F
F
G
G
F
F
Fig. 10  
Replacing the ambient lighting  
side lamps  
In normal use, the LED ambient lighting should not require  
replacement and is intended to last the lifetime of the product.  
In the event that these lights fail to operate, please contact our  
service department for repair.  
5
 
Installation  
IMPORTANT:  
The extractor is intended to be mounted to the ceiling  
using fixings appropriate for the ceiling. Ensure that  
there is adequate ceiling strength and supports at the  
fixing points; if in doubt, consult a joiner or electrician.  
INSTALLATION:  
The extractor is intended to be operated as a re-circulation  
device suspended from the ceiling, as shown in Fig 11.  
When installing this appliance over a CDA hob, the clearance  
between the extractor and the hob must be equal to or exceed  
650mm. This instruction overrides the instructions supplied  
with the CDA hob. (The height should be measured from the  
top of the hotplates or burners)  
Where the extractor is to be installed above a non-CDA hob,  
the instructions supplied with the hob may dictate that the  
height required above the hob is greater than 650mm.  
650mm  
IN THE ABSENCE OF ANY INSTRUCTIONS SUPPLIED  
WITH THE HOB, THE MINIMUM DISTANCE BETWEEN  
THE HOB AND EXTRACTOR MUST BE AT LEAST 760mm  
Fig. 11  
Mounting The Extractor  
1. Using the supplied template, mark the positions of the 3  
main fixing holes (E) and the 2 additional fixing holes (X)  
on the ceiling.  
min 3mm  
2. Drill and plug the holes, as required. If screwing  
directly to the ceiling joists, plugs may not be required  
(See Important note above)  
3. Insert 3 screws (E) into the main fixings, leaving  
approximately 3mm protruding, as shown in Fig 12.  
E
E
E
E
Fig. 12  
6
 
Mounting The Extractor  
4. Fit the ceiling support plate into position on the 3 screws  
and rotate it into position, as shown in Fig 13. Ensure  
that the mains supply cable is located in position and is  
not trapped or damaged.  
E
B
X
X
E
X
E
5. When in position, tighten the 3 main screws and fit 2  
additional screws to fix the support plate in position.  
E
6. When used with a CDA hob, the extractor is required  
to be 650mm above the hotplates. Measure the height of  
the ceiling and then the hotplate height from the floor.  
The length of the wire supports should be calculated  
as follows: -  
X
Fig. 13  
Length of cable = Ceiling height – (350 + 650 + Hotplate  
height)  
X = C - (350+650+B)  
X
Adjust the cables to the approximate required length (X in Fig  
15). These can be adjusted after install, if required. Ensure that  
the cable is looped back through the second safety fixing (Y in  
Fig 15) to ensure there is no risk of the cables slipping.  
350  
650  
C
B
Fig. 14  
A
X
A
Y
Fig. 15  
7
 
Mounting The Extractor  
2/3mm  
B
G
1
2
3
F
G
H
F
H
C
Fig. 16  
7. Loosen the body fixing screws (G in Fig 16) by  
approximately 3mm and hook the cable fixing bracket into  
place. Lift the bracket into position and tighten the screw to  
lock the bracket in position, then insert an additional screw  
(H) for security.  
8. Make any adjustments to the cable length, ensuring that the  
extractor is level. Using 2 x 8mm spanners, the extractor can  
be levelled using the adjustment system Fig. 17  
2
R
9. Mount the mains connection box (S) to the ceiling support  
plate using the 2 supplied screws (D) and proceed to  
connect the appliance to the mains supply, as shown below.  
Once complete, secure the connection box lid with the  
2 screws. If you are in doubt as to how to connect the  
appliance to the mains supply consult a qualified electrician.  
D
1
Fig. 17  
2
3
S
D
1
4
E
1
4
D
Fig. 18  
8
 
Installation  
11. Fit the fixing support cover panel (C) and secure with the  
two supplied screws (A), as shown in Fig 19.  
A
B
12. Fit the extractor top panel, as shown in Fig 20, using the  
8 supplied screws (G). Again, ensure that the mains  
supply cable is not trapped.  
C
A
12. Fit the 2 decorative curved panels (M1 and M2) to the  
body of the extractor as shown; note these can be  
installed offset as shown, or at the same level, as  
preferred. Insert the screws (X) into the body leaving  
approximately 3mm protruding. Hang the panels onto  
the body as shown, finally tightening the screws to secure  
the chimney, using a stubby screwdriver or spanner.  
Fig. 19  
A
M
1
M
M
2
1
X
X
2/3 mm  
X
G
2
1
2
3
X
2
Fig. 20  
6
X
Fig. 21  
9
 
Mains Electricity Connection  
THIS APPLIANCE MUST BE CONNECTED TO THE MAINS SUPPLY BY A COMPETENT PERSON, USING FIXED  
WIRING VIA A DOUBLE POLE SWITCHED FUSE SPUR OUTLET AND PROTECTED BY A 3A FUSE.  
We recommend that the appliance is connected by a qualified electrician, who is a member of the N.I.C.E.I.C. and who will  
comply with the I.E.E. and local regulations.  
The wires in the mains lead of this appliance are coloured in accordance with the following code:  
Green & Yellow = Earth, Blue = Neutral, Brown = Live.  
As the colours of the wires in the mains lead for the appliance may not correspond  
DOUBLE POLE SWITCHED  
FUSE SPUR OUTLET  
with the coloured markings identifying the terminals connecting to the fuse spur,  
proceed as follows:  
The wire which is coloured green and yellow must be connected to the  
terminal marked E (Earth) or coloured green.  
The wire which is coloured blue must be connected to the terminal marked  
N (Neutral), or coloured black.  
The wire which is coloured brown must be connected to the terminal marked  
L (Live), or coloured red.  
USE A 3 AMP FUSE  
Note: Use a 3A Fuse  
Assembly and electrical connection should be carried out by specialised personnel.  
When installing this product we recommend you seek the help of another individual.  
Electrical Information  
Mains electrical voltage: 230 – 240Vac, 50Hz  
Total rated power consumption:  
290W  
Troubleshooting  
If your extractor is not working:  
1.  
Check that the mains supply has not been switched off.  
2. Check that the fuse in the spur has not blown.  
10  
 
To contact our Customer Care Department, or for Service,  
please contact us on the details below.  
Customer Care Department • The  
Group Ltd. • Harby Road • Langar • Nottinghamshire • NG13 9HY  
T : 01949 862 012 F : 01949 862 003 E : [email protected] W : www.cda.eu  
 

Bissell Vacuum Cleaner 12U9 User Manual
Bosch Appliances GPS Receiver TTO215 User Manual
Briggs Stratton Power Supply 071013 User Manual
Brinkmann Charcoal Grill Dual Zone Charcoal Grill User Manual
Brother Sewing Machine NV4750D User Manual
Canon Photo Scanner 350II User Manual
Casio Electronic Keyboard CTK 630 User Manual
Casio Electronic Keyboard LK300AR1A User Manual
Casio Musical Toy Instrument CTK 2080 User Manual
Chief Manufacturing Indoor Furnishings PNR User Manual