Type ADH and ADHT
Air Duct Heaters
Specifications — Table A
No. Mtg.
Holes
9/32”
Dia.
Approx.
Net. Wt.
(Lbs.)
Approx.
Net. Wt.
(Lbs.)
Dimensions (In.)
No.
No.
Circuits
Model
Model
Volts
Phase kW Elements
A
B
C
D
E
H
K
L
M
ADH-005
ADH-010
ADH-015
8
15
25
ADHT-005
ADHT-010
ADHT-015
10
20
30
480
480
480
3
3
3
5
10
15
3
6
9
10
10
12
1
1
1
5-5/8 20-3/8 28-1/8
7-5/8 20-3/8 28-1/8
9-5/8 20-3/8 28-1/8
4
6
8
1/4 2-1/2 3-1/2 11-1/8 9-1/2
1/4 3-1/2 3-1/2 11-1/8 9-1/2
1/4
3
3-1/2 11-1/8 9-1/2
ADH-020
ADH-025
ADH-030
35
40
55
ADHT-020
ADHT-025
ADHT-030
40
50
65
480
480
480
3
3
3
20
25
30
12
15
18
14
14
14
1
1
1
11-5/8 20-3/8 28-1/8 10
13-5/8 20-3/8 28-1/8 12
15-5/8 20-3/8 28-1/4 14
1/4 2-3/4 3-1/2 11-1/8 9-1/2
1/4 3-1/4 3-1/2 11-1/8 9-1/2
3/8 3-3/4 3-1/2 11-1/8 9-1/2
ADH-035
ADH-040
ADH-045
65
70
80
ADHT-035
ADHT-040
ADHT-045
80
90
100
480
480
480
3
3
3
35
40
45
21
24
27
14
14
14
1
2
2
17-5/8 20-3/8 28-1/4 16
19-5/8 20-3/8 28-1/4 18
21-5/8 20-3/8 28-1/4 20
3/8 4-1/4 3-1/2 11-1/8 9-1/2
3/8 4-3/4 3-1/2 11-1/8 9-1/2
3/8 5-1/4 3-1/2 11-1/8 9-1/2
ADH-050
ADH-060
ADH-080
90
105
140
ADHT-050
ADHT-060
ADHT-080
110
130
175
480
480
480
3
3
3
50
60
80
30
36
48
14
18
22
2
2
4
23-5/8 20-3/8 28-1/4 22
27-5/8 20-3/8 28-1/4 26
35-5/8 20-3/8 28-1/4 34
3/8 5-3/4 3-1/2 11-1/8 9-1/2
3/8 4-1/2 3-1/2 11-1/8 9-1/2
3/8 4-3/8 3-1/2 11-1/8 9-1/2
ADH-090
ADH-100
—
160
175
—
ADHT-090
ADHT-100
ADHT-120
200
220
205
480
480
480
3
3
3
90
100
120
54
60
36
22
22
18
5
5
4
39-5/8 20-3/8 28-1/4 38
43-5/8 20-3/8 28-1/4 42
27-5/8 35 42-7/8 26
3/8 4-7/8 3-1/2 11-1/8 9-1/2
3/8 5-3/8 3-1/2 11-1/8 9-1/2
3/8 4-1/2 3-1/2 11-1/8 9-1/2
ADH-144
—
ADH-162
165
—
185
—
ADHT-160
—
—
270
—
480
480
480
3
3
3
144
160
162
48
48
54
22
22
22
4
8
6
35-5/8 35 42-7/8 34
35-5/8 35 42-7/8 34
39-5/8 35 42-7/8 38
3/8 4-3/8 3-1/2 11-1/8 9-1/2
3/8 4-3/8 3-1/2 11-1/8 9-1/2
3/8 4-7/8 3-1/2 11-1/8 9-1/2
—
ADH-216F
—
—
240
—
ADHT-180
—
ADHT-240F
305
—
400
480
480
480
3
3
3
180
216
240
54
72
72
22
22
22
6
6
8
39-5/8 35 42-7/8 38
27-5/8 35 42-7/8 26
27-5/8 35 42-7/8 26
3/8 4-7/8 3-1/2 11-1/8 9-1/2
3/8 4-1/2 3-7/8
3/8 4-1/2 3-7/8
20 18-3/8
20 18-3/8
ADH-270F
—
300
—
—
—
500
480
480
3
3
270
300
90
90
22
22
8
10
33-5/8 35 42-7/8 32
33-5/8 35 42-7/8 32
3/8 5-1/2 3-7/8
3/8 5-1/2 3-7/8
20 18-3/8
20 18-3/8
ADHT-300F
Type ADH
Type ADHT
Airflow
Direction
Airflow
Direction
Figure 1 — Dimensions
Figure 2 — Dimensions
© 2004 Chromalox, Inc.
INSTALLATION (cont’d.)
6. In high ambient temperature operations, least corrosive action
and least oxidation to the terminals will occur if the heaters are
mounted with the terminals in the coolest possible ambient,
usually on the bottom or side of the duct.
HAZARD OF FIRE. Since these heaters are capable of
developing high temperatures, extreme care should
be taken to:
A. Minimum duct size is “A” or “L” dimension +3/8” and “B”
A. Avoid installing heaters in an atmosphere containing com-
dimension +1-5/8”.
bustible gases and vapors.
B. Avoid contact between heater and combustible material.
C. Keep combustible materials far enough away to be free of
the effects of high temperatures.
ADHT High temperature duct heaters — are generally mounted on field fabricated stand
off supports from the ductwork to position the heater such that the 3” insulation housing
is in the same plane as the duct insulation.
ADH Low temperature duct heaters — can be fastened directly to the sheet metal duct
work with bolts or sheet metal screws.
Duct
Duct
Air
Air
Standoff Collar
Air
Air
Insulation
(3" max.)
Figure 6
Figure 7
Temperature Control Instructions
3. For heater protection, the indicated maximum temperature of
the control unit should be 50°F less than the actual maximum
air temperature that will be permitted, to allow for overshoot.
4. Single circuit heater elements may be wired into two circuits to
allow for partial heating and control. It is important to have
thermal control wired into all electric power circuits, so that all
elements may be protected from overheat.
1. A Chromalox thermal cutout or thermostat is recommended for
overheat protection and control of heater and process. Consult
local Chromalox representative.
2. In general, place thermostat sensing element close to the heat-
ing elements, near top of duct, at right angles to the direction of
air flow, and on the downstream side of the heater. Thermostat,
provided with a manual reset button, is separately mounted.
WIRING
devices with their electric heating equipment. Selection of con-
trols, thermostat, SCR units, contactors and etc. depends on the
degree of accuracy required, reliability, electrical rating of
heater and economic considerations.
ELECTRIC SHOCK HAZARD. Any installation involv-
ing electric heaters must be performed by a quali-
fied person and must be effectively grounded in
accordance with the National Electrical Code to
eliminate shock hazard.
5. Below is an example of a standard ADH-015, 480V 3 Ø 15 kW,
wired with recommended back-up controls. (Figure 8)
6. Individual terminal blocks with 1/4-20 threaded stud type terminals
are provided for each circuit to permit quick positive attachment of
circuit wiring conductors (one terminal block per circuit). (Figure 9)
1. All wiring should be done in accordance with National Electrical
Code and with local codes by a qualified person.
2. Connect air heaters to same line voltage, phase, and frequency
as on heater nameplate.
3. Teflon insulated nickel plated copper wire or bus bar is recom-
mended for power connections to heater terminals and for
wiring runs in heated zones. When ambient temperature in
heated zone exceeds that for which insulated wire is recom-
mended use bare nickel-plated copper with porcelain beads,
tubing or bus bar. Consult local Chromalox representative.
4. Users should install adequate back-up controls and safety
Terminal block
(303-027852-001)
✸
X Circuit label indicated here.
Figure 9
ADH-015, 15 kW 480V 3ø, 1 Circuit
(9) - 480V, 1667 Watt Elements
Magnetic
Contactor
Fused
Switch
Terminal
Block
L1
L1
L
2
L
2
3
L
L
3
ADH-015
Control
Voltage
120 or 240V
Customer Supplied Wiring
Factory Supplied Wiring
Thermostat
Figure 8
Control Switch
3
OPERATION
Do not operate heater at voltages in excess of that stamped on
the heater since excess voltage will shorten heater life.
MAINTENANCE
1. Periodically clean terminals and terminal covers of dust and corro-
sion to maintain good electrical connections and to permit rapid
heat dissipation. Use airblast, and be careful to avoid damage to
mica insulation.
ELECTRIC SHOCK HAZARD. Disconnect all power
before installing or servicing heater. Failure to do
so could result in personal injury or property dam-
age. Heater must be installed by a qualified person
in accordance with the National Electrical Code,
NFPA 70.
2. Check for loose terminal connections. Tighten as necessary.
WIRING DIAGRAMS
ADH-005, ADHT-005, ADH-010, ADHT-010,
ADHT-120, ADH-144, ADHT-160, ADH-162,
ADHT-180, ADH-216F, ADHT-240F, ADH-270F,
ADH-300F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
ADH-015, ADHT-015, ADH-020, ADHT-020,
ADH-025, ADHT-025, ADH-030, ADHT-030,
ADH-035, ADHT-035 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
ADH-040, ADHT-040, ADH-045, ADHT-045,
ADH-050, ADHT-050, ADH-060, ADHT-060,
ADH-080, ADHT-080, ADH-090, ADHT-090,
ADH-100, ADHT-100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
ADH-005, ADHT-005
ADH-010, ADHT-010
1 Circuit, 6 Elements per Heater
ADH-015, ADHT-015
1 Circuit, 9 Elements per Heater
AL1
1 Circuit, 3 Elements per Heater
AL1
AL1
AL2
AL3
AL2
AL2
AL3
AL3
Circuit A
Circuit A
Circuit A
Circuit A
Circuit A
ADH-020, ADHT-020
ADH-025, ADHT-025
1 Circuit, 15 Elements per Heater
AL1
1 Circuit, 12 Elements per Heater
AL1
AL2
AL3
AL2
AL3
Circuit A
ADH-030, ADHT-030
ADH-035, ADHT-035
1 Circuit, 21 Elements per Heater
1 Circuit, 18 Elements per Heater
AL1
AL2
AL3
AL1
AL2
AL3
Circuit A
4
WIRING DIAGRAMS
ADH-040, ADHT-040
2 Circuits per Heater, Circuit A, B, 12 Elements per Circuit,
24 Elements per Heater
ADH-045, ADHT-045
2 Circuits per Heater, Circuit A, 15 Elements,
Circuit B, 12 Elements, 27 Elements per Heater
AL1
AL2
AL3
BL1
BL2
AL1, BL1
AL2, BL2
AL3, BL3
BL3
Typical Circuit
Circuit A
ADH-050, ADHT-050
Circuit B
2 Circuits per Heater, Circuit A 18 Elements, Circuit B 12 Elements, 30 Elements per Heater
AL1
BL1
BL2
BL3
AL2
AL3
Circuit A
Circuit B
ADH-080, ADHT-080
4 Circuits per Heater, Circuit A, B, C, D,
12 Elements per Circuit, 48 Elements per Heater
ADH-060, ADHT-060
2 Circuits per Heater, Circuit A, B,
18 Elements per Circuit, 36 Elements per Heater
AL1, BL1
AL1, BL1, CL1, DL1
AL2, BL2, CL2, DL2
AL2, BL2
AL3, BL3
AL3, BL3, CL3, DL3
Typical Circuit
Typical Circuit
ADH-090, ADHT-090
ADH-100, ADHT-100
5 Circuits per Heater, Circuit A, B, C, D, 12 Elements per Circuit,
Circuit E, 6 Elements, 54 Elements per Heater
5 Circuits per Heater, Circuit A, B, C, D, E,
12 Elements per Circuit, 60 Elements per Heater
AL1, BL1, CL1, DL1
EL1
AL1, BL1, CL1, DL1, EL1
AL2, BL2, CL2, DL2
EL2
AL2, BL2, CL2, DL2, EL2
AL3, BL3, CL3, DL3
AL3, BL3, CL3, DL3, EL3
EL3
Circuit A, B, C, D
Circuit E
Typical Circuit
5
WIRING DIAGRAMS
ADHT-120
ADH-144
4 Circuits per Heater, Circuit A, B, C, D,
9 Elements per Circuit, 36 Elements per Heater
4 Circuits per Heater, Circuit A, B, C, D,
12 Elements per Circuit, 48 Elements per Heater
AL1, BL1, CL1, DL1
AL1, BL1, CL1, DL1
AL2, BL2, CL2, DL2
AL2, BL2, CL2, DL2
AL3, BL3, CL3, DL3
AL3, BL3, CL3, DL3
Typical Circuit
Typical Circuit
ADH-160
8 Circuits, Circuit A, B, C, D, E, F, G, H,
6 Elements per Circuit, 48 Elements per Heater
ADH-162, ADHT-180
6 Circuits, Circuit A, B, C, D, E, F,
9 Elements per Circuit, 54 Elements per Heater
AL1, BL1, CL1, DL1, EL1, FL1, GL1, HL1
AL2, BL2, CL2, DL2, EL2, FL2, GL2, HL2
AL3, BL3, CL3, DL3, EL3, FL3, GL3, HL3
AL1, BL1, CL1, DL1, EL1, FL1
AL2, BL2, CL2, DL2, EL2, FL2
AL3, BL3, CL3, DL3, EL3, FL3
Typical Circuit
Typical Circuit
ADH-216F
ADHT-240F
ADH-270F
ADH-300F
10 Circuits,
8 Circuits,
6 Circuits,
8 Circuits,
Circuit A, B, C, D, E, F, G, H, I, J,
9 Elements per Circuit,
Circuits A, B, C, D, E, F, G,
Circuit A, B, C, D, E, F,
12 Elements per Circuit, 72
Elements per Heater
Circuit A, B, C, D, E, F, G, H,
9 Elements per Circuit, 72
Elements per Heater
12 Elements per Circuit, Circuit H,
6 Elements, 90 Elements per Heater
90 Elements per Heater
AL1, BL1,
HL1
AL1, BL1, CL1,
DL1, EL1, FL1
CL1, DL1,
EL1, FL1, GL1
AL1, BL1,
CL1, DL1,
AL2, BL2,
EL1, FL1,
AL1, BL1,
L2, BL2,
CL2, DL2,
GL1, HL1,
CL1, DL1,
EL1, FL1,
GL1, HL1
L2, DL2,
L2, FL2,
L2, HL2
EL2, FL2,
IL1, JL1
GL2, HL2,
IL2, JL2
AL3, BL3,
CL3, DL3,
EL3, FL3,
GL3, HL3,
IL3, JL3
AL3, BL3,
CL3, DL3,
EL3, FL3,
GL3, HL3
AL2, BL2,
AL2, BL2, CL2,
DL2, EL2, FL2
HL2
CL2, DL2,
EL2, FL2, GL2
AL3, BL3,
HL3
AL3, BL3, CL3,
DL3, EL3, FL3
CL3, DL3,
EL3, FL3, GL3
Typical Circuit
Typical Circuit
Circuit A - G
Circuit H
Typical Circuit
6
RENEWAL PARTS IDENTIFICATION — TYPE ADH
❶
❷
❸ *
Element
Retaining Clip
❹
❺
❻
Individual
Replacement
Element
Element
Spacer Plate
Support Rod
Spacers
Terminal Block
Assembly
Flange
Model
ADH-005
ADH-010
ADH-015
ADH-020
ADH-025
ADH-030
ADH-035
ADH-040
ADH-045
ADH-050
ADH-060
ADH-080
ADH-090
ADH-100
ADH-144
ADH-162
393-055440-007 (3)
393-055440-006 (6)
393-055440-007 (9)
393-055440-006 (12)
393-055440-007 (15)
393-055440-006 (18)
393-055440-007 (21)
393-055440-006 (24)
393-055440-007 (27)
393-055440-006 (30)
393-055440-006 (36)
393-055440-006 (48)
393-055440-006 (54)
393-055440-006 (60)
393-055440-009 (48)
393-055440-009 (54)
121-055367-001
121-055367-002
121-055367-003
121-055367-004
121-055367-005
121-055367-006
121-055367-007
121-055367-008
121-055367-009
121-055367-010
121-055367-011
121-055367-013
121-055367-014
121-055367-015
121-055367-013
121-055367-014
272-511327-001 (6)
272-511327-001 (12)
272-511327-001 (18)
272-511327-001 (24)
272-511327-001 (30)
272-511327-001 (36)
272-511327-001 (42)
272-511327-001 (48)
272-511327-001 (54)
272-511327-001 (60)
272-511327-001 (72)
272-511327-001 (96)
272-511327-001 (108)
272-511327-001 (120)
272-511327-001 (96)
272-511327-001 (108)
271-055370-001
271-055370-002
271-055370-003
271-055370-004
271-055370-005
271-055370-006
271-055370-007
271-055370-008
271-055370-009
271-055370-010
271-055370-011
271-055370-013
271-055370-014
271-055370-015
271-055370-013 (2)
271-055370-014 (2)
242-055376-001 (4)
242-055376-001 (4)
242-055376-001 (4)
242-055376-001 (4)
242-055376-001 (4)
242-055376-001 (4)
242-055376-001 (4)
242-055376-001 (4)
242-055376-001 (4)
242-055376-001 (4)
242-055376-001 (4)
242-055376-001 (5)
242-055376-001 (6)
242-055376-001 (6)
242-055376-001 (10)
242-055376-001 (12)
303-027852-001
303-027852-001
303-027852-001
303-027852-001
303-027852-001
303-027852-001
303-027852-001
303-027852-001 (2)
303-027852-001 (2)
303-027852-001 (2)
303-027852-001 (2)
303-027852-001 (4)
303-027852-001 (5)
303-027852-001 (5)
303-027852-001 (4)
303-027852-001 (6)
ADH-216F
ADH-270F
393-055440-171 (72)
393-055440-171 (90)
121-055367-032
121-055367-033
271-055370-866 (2)
271-055370-867 (2)
242-055376-001 (12)
242-055376-001 (12)
303-027852-001 (6)
303-027852-001 (8)
NOTE: Number in parentheses ( ) indicates the quantity of that part required.
* Older heaters may have retaining channels instead of clips. Contact Factory for
part number and quantity.
ADH Replacement Element Rating
Volts
Part No.
Watts
393-055440-171 (w/ftgs)
393-055440-006
393-055440-007
480
240
480
480
3000
1667
1667
3000
393-055440-009
Upper
Terminal Box
Lower
Terminal Box
Knockouts for
Line Connections
Other Parts Common to all Heaters
❷
❶
❹
❺
❸
❻
(except ADH-216F
and ADH-270F)
7
RENEWAL PARTS IDENTIFICATION — TYPE ADHT
❶
❷
❸
❹ *
❺
Element
Spacer Plate
❻
❼
❽
Individual
Replacement
Element
Element
Support Rod
Spacers
Terminal Block
Assembly
Thermocouple
Terminal Block
Thermocouples
Flange
Model
Retaining Clip
ADHT-005 393-055441-007 (3) 309-122380-003 121-055367-001
ADHT-010 393-055441-006 (6) 309-122380-003 121-055367-002
ADHT-015 393-055441-007 (9) 309-122380-003 121-055367-003
ADHT-020 393-055441-006 (12) 309-122380-003 121-055367-004
ADHT-025 393-055441-007 (15) 309-122380-003 121-055367-005
ADHT-030 393-055441-006 (18) 309-122380-003 121-055367-006
ADHT-035 393-055441-007 (21) 309-122380-003 121-055367-007
ADHT-040 393-055441-006 (24) 309-122380-003 121-055367-008
ADHT-045 393-055441-007 (27) 309-122380-003 121-055367-009
ADHT-050 393-055441-006 (30) 309-122380-003 121-055367-010
ADHT-060 393-055441-006 (36) 309-122380-003 121-055367-011
ADHT-080 393-055441-006 (48) 309-122380-003 121-055367-013
272-511327-001 (6)
272-511327-001 (12)
272-511327-001 (18)
272-511327-001 (24)
272-511327-001 (30)
272-511327-001 (36)
272-511327-001 (42)
272-511327-001 (48)
272-511327-001 (54)
272-511327-001 (60)
272-511327-001 (72)
272-511327-001 (96)
271-055370-016
271-055370-017
271-055370-018
271-055370-019
271-055370-020
271-055370-021
271-055370-022
271-055370-023
271-055370-024
271-055370-025
271-055370-026
271-055370-028
271-055370-029
271-055370-030
242-055376-002 (4)
242-055376-002 (4)
242-055376-002 (4)
242-055376-002 (4)
242-055376-002 (4)
242-055376-002 (4)
242-055376-002 (4)
303-027852-001
303-027852-001
303-027852-001
303-027852-001
303-027852-001
303-027852-001
303-027852-001
303-122014-002
303-122014-002
303-122014-002
303-122014-002
303-122014-002
303-122014-002
303-122014-002
242-055376-002 (4) 303-027852-001 (2) 303-122014-002
242-055376-002 (4) 303-027852-001 (2) 303-122014-002
242-055376-002 (4) 303-027852-001 (2) 303-122014-002
242-055376-002 (4) 303-027852-001 (2) 303-122014-002
242-055376-002 (5) 303-027852-001 (4) 303-122014-002
242-055376-002 (6) 303-027852-001 (5) 303-122014-002
242-055376-002 (6) 303-027852-001 (5) 303-122014-002
242-055376-002 (8) 303-027852-001 (4) 303-122014-002
ADHT-090 393-055441-006 (54) 309-122380-003 121-055367-014 272-511327-001 (108)
ADHT-100 393-055441-006 (60) 309-122380-003 121-055367-015 272-511327-001 (120)
ADHT-120 393-055441-009 (36) 309-122380-003 121-055367-011
ADHT-160 393-055441-009 (48) 309-122380-003 121-055367-013
272-511327-001 (72) 271-055370-026 (2)
272-511327-001 (96) 271-055370-028 (2) 242-055376-002 (10) 303-027852-001 (8) 303-122014-002
ADHT-180 393-055441-009 (54) 309-122380-003 121-055367-014 272-511327-001 (108) 271-055370-029 (2) 242-055376-002 (12) 303-027852-001 (6) 303-122014-002
ADHT-240F 393-055441-159 (72) 309-122380-003 121-055367-032
271-055370-833 (2) 242-055376-002 (12) 303-027852-001 (8) 303-122014-002
ADHT-300F 393-055441-159 (90) 309-122380-003 121-055367-033
271-055370-834 (2) 242-055376-002 (12) 303-027852-001 (10) 303-122014-002
NOTE: Number in Parentheses ( ) indicates the quantity of that part required.
* Older heaters may have retaining channels instead of clips. Contact Factory for part
number and quantity.
ADHT Replacement Element Rating
Volts
Part No.
Watts
393-055441-159 (w/ftgs)
393-055441-006
393-055441-007
480
240
480
480
3333
1667
1667
3333
Upper
Terminal Box
Lower
Terminal Box
393-055441-009
Other Parts Common to all Heaters
Knockouts for
Line Connections
❸
Thermocouple
Terminal Box
Insulation
Housing
❹
(except ADHT-240F
and ADHT-300F)
Max. Temp 800˚F
❶
❷
❼
❻
❽
❺
WARRANTY AND LIMITATION OF REMEDY AND LIABILITY
Chromalox warrants only that the Products and parts manufactured by Chromalox, when shipped, and the work performed by and expenses therefor, including but not limited to attorney's fees, and indemnifies Chromalox against any liability to Chromalox's
Chromalox when performed, will meet all applicable specification and other specific product and work requirements (including vendors arising out of such litigation.
those of performance), if any, and will be free from defects in material and workmanship under normal conditions of use. All
claims for defective or nonconforming (both hereinafter called defective) Products, parts or work under this warranty must be replace its Products, parts or work at the original f.o.b. point of delivery or (ii) refund an equitable portion of the purchase price.
made in writing immediately upon discovery, and in any event, within one (1) year from delivery, provided, however all claims for THE FOREGOING IS CHROMALOX'S ONLY OBLIGATION AND BUYER'S EXCLUSIVE REMEDY FOR BREACH OF WARRANTY,
Upon Buyer's submission of a claim as provided above and its substantiation, Chromalox shall at its option either (i) repair or
defective Products and parts must be made in writing no later than eighteen (18) months after shipment by Chromalox. Defective AND IS BUYER'S EXCLUSIVE REMEDY AGAINST CHROMALOX FOR ALL CLAIMS ARISING HEREUNDER OR RELATING HERE-
and nonconforming items must be held for Chromalox's inspections and returned to the original f.o.b. point upon request. THE TO WHETHER SUCH CLAIMS ARE BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILI-
FOREGOING IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES WHATSOEVER, EXPRESS, IMPLIED AND STATUTORY, TY) OR OTHER THEORIES, BUYER'S FAILURE TO SUBMIT A CLAIM AS PROVIDED ABOVE SHALL SPECIFICALLY WAIVE ALL
INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR CLAIMS FOR DAMAGES OR OTHER RELIEF, INCLUDING BUT NOT LIMITED TO CLAIMS BASED ON LATENT DEFECTS. IN NO
PURPOSE.
EVENT SHALL BUYER BE ENTITLED TO INCIDENTAL OR CONSEQUENTIAL DAMAGES AND BUYER SHALL HOLD CHROMALOX
Notwithstanding the provisions of this WARRANTY AND LIMITATION Clause, it is specifically understood that Products and HARMLESS THEREFROM. ANY ACTION BY BUYER ARISING HEREUNDER OR RELATING HERETO, WHETHER BASED ON
parts not manufactured and work not performed by Chromalox are warranted only to the extent and in the manner that the same BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORIES, MUST BE COM-
are warranted to Chromalox by Chromalox's vendors, and then only to the extent that Chromalox is reasonably able to enforce MENCED WITHIN ONE (1) YEAR AFTER THE DATE OF SHIPMENT OR IT SHALL BE BARRED.
such warranty, it being understood Chromalox shall have no obligation to initiate litigation unless Buyer undertakes to pay all cost
W2008M
2150 N. RULON WHITE BLVD., OGDEN, UT 84404
TA - W4 - EF.
Litho in U.S.A.
|