QuickSpecs
StorageWorks NAS B3000 by Compaq
Overview
Models
Mo d e l N900
230050-001
Mo d e l C900
258123-001
Mo d e l N900s
230051-001
Mo d e l C900s
258124-001
Product Highlights
Compaq, the leader in Network Storage, delivers the
StorageWorks™ NAS B3000 by Compaq – the entry-point
into NAS/SAN fusion solutions bringing enterprise-level
availability, scalability and performance in a turnkey
package
•
Entry-point to the fusion of NAS and SAN – Universal
Network Storage – provides the best utilization of
storage investment. Consolidate NAS and SAN into a
single, managed storage infrastructure
•
•
Enterprise level scalability – to 27 TB
Highly available solution – including clustering, RAID
ADG, fully integrated software packages, no-single-
point-of-failure configurations available
•
Turnkey package – configurations include all of the
components to provide high performance block- and
file-serving
Key Benefits
Maximized Return on Storage Investment
•
Multi-protocol file serving – support for Microsoft
Windows (CIFS), UNIX /Linux (NFS), Novell
NetWare (NCP), Apple (AppleTalk), HTTP and FTP
Minimize ongoing operational expenses associated with
file serving
Enable clients and applications to easily access data
over the existing network, while also reducing the cost
of accessing SAN based storage
•
•
•
Save money and resources with centralized storage and
system management
Unlimited Scalability
•
Grow your storage capacity as your business grows-
without downtime and without compromising
performance
•
•
Up to 27 TB capacity scalability, higher capacity can be
reached with external switches
The B3000 supports both 1 Gb/sec and 2 Gb/sec Fibre
channel fabrics to ensure that your investment in
infrastructure is protected.
•
DAS to SAN means file data that is currently stored on
1″ Universal disk drives using newer Compaq Smart
Array controllers, as well as file data on an RA4100 can
easily be migrated to the B3000. Simply remove the
drives from the older systems and insert them into the
B3000. All configuration information and data will be
preserved allowing migration to be completed in
minutes, not hours or days.
Continuous Data Availability
•
Ensure that data is always available enabling business
continuance through:
•
•
•
•
•
•
Cluster Configurations
Advanced Data Guarding
Hardware redundancy
File replication
Backup support
Antivirus support
DA-11339
Canada — Version 7 — September 24, 2002
1
QuickSpecs
StorageWorks NAS B3000 by Compaq
NAS B3000 Base Configurations
Two (2) Intel Pentium III 900-MHz Xeon Processors standard (up to 4
supported)
Processor
NAS B3000
Model N900s
Cache Memory
Memory
2-MB Level 2 writeback cache per processor
2 GB (Standard, 4 x 512-MB ECC SDRAM) to 4 GB (Maximum)
230051-001
Network Controller
Integrated Compaq NC3134 and NC3135 Fast Ethernet NIC 64 PCI
Dual Port 10/100 in a slot
(4 total 10/100 ports standard)
One (1) FCA2101 Host Adapter
Host Bus Adapter
Storage Controller
Integrated Smart Array Controller (Two channel, one channel is SCSI
only for backup)
Hard Drive
Two (2) 36.4-GB Ultra3 10K 1″ for redundant system software
Two (2) Hot pluggable 450 W Power Supplies
24x IDE CD-ROM Drive
Power Supply
Optical Drive
External Storage
One (1) MSA1000 with controller and 4 x 72-GB Ultra3 10K 1″ drives
Embedded Switch
Form Factor
One (1) 6 port embedded 2-Gb switch
Rack 8U
Two (2) Intel Pentium III 900-MHz Xeon Processors standard (up to 4
supported)
Processor
NAS B3000
Model C900s
Cache Memory
Memory
Network Controller
2MB Level 2 write back cache per processor
2GB (Standard, 4x 512MB ECC SDRAM) to 4GB (Maximum)
258124-001
The clustered offerings of the
Integrated Compaq NC3134 and NC3135 Fast Ethernet NIC 64 PCI
Dual Port 10/100 in a slot
(4 total 10/100 ports standard)
StorageWorks NAS B3000 include two (2)
server heads & one (1) MSA1000 SAN.
The specifications shown are
representative of what is included in each
individual server head.
Host Bus Adapter
Storage Controller
Two (2) FCA2101 Host Adapters
Integrated Smart Array Controller (Two channel, one channel is SCSI
only for backup)
Hard Drive
Two (2) 36.4-GB Ultra3 10K 1″ for redundant system software
Two (2) Hot pluggable 450 W Power Supplies
24x IDE CD-ROM Drive
Internal Storage
Power Supply
Optical Drive
Two (2) Intel Pentium III 900-MHz Xeon Processors standard (up to 4
supported)
One (1) MSA1000 with two controllers and 6 x 72-GB Ultra3 10K 1″
drives
External Storage
Embedded Switch
Form Factor
Two (2) 6 port embedded 2 Gb switches
Rack 12U
DA-11339
Canada — Version 7 — September 24, 2002
3
QuickSpecs
Standard Features
Proces s or
StorageWorks NAS B3000 by Compaq
Model N900, C900, N900s, C900s
Two (2) Intel Pentium III Xeon 900-MHz processors (upgradeable to 4)
2-MB level 2 write back cache per processor standard
Cache Memory
Memory
Standard
Maximum
2 GB (512 x 4 PC100MHz ECC SDRAM Memory with Advanced ECC functionality)
4 GB
NOTE: Advanced ECC Memory Technology protects the data even in the event of an entire SDRAM component
failure. Embedded in the chipset design, this feature allows the use of Industry-Standard Registered
DIMMs.
Upgradeable to four processors, upgradeable to 4 GB of ECC SDRAM, upgradeable storage capacity
Upgradability
Integrated Compaq NC3134 Fast Ethernet NIC 64 PCI Dual Base 10/100 in a slot and a Compaq NC3135 Fast
Ethernet NIC 64 PCI dual 10/100 daughter card (total 10/100 ports is 4) (Gigabit options available)
Network Controller
FCA2101 Host Bus Adapter
Hos t Adapters
I/O (6 Total, 2 Available)
PCI Voltage:
Expans ion Slots
Two (2) 64-bit/66-MHz PCI Hot Plug
Two (2) 64-bit/33-MHz PCI Hot Plug
One (1) 64-bit/33-MHz PCI Non-Hot Plug 0 available
One (1) 32-bit/33-MHz PCI Non-Hot Plug 1 available
1 available
0 available
3.3 Volt Only
5 Volt or 3.3 Volt
5 Volt or 3.3 Volt
5 Volt Only
NOTE: One 64-bit/66-MHz PCI Hot Plug slot available and one 32-bit/33-MHz PCI Non-Hot Plug slot available
Integrated Smart Array Controller (Two channel) (supports Internal RAID 0, 1, 0+1, 5 and external tape devices)
Storage Controller
Internal Storage
Diskette Drives
CD-ROM
1.44 MB
24x IDE CD-ROM Drive (slim line)
Hard Drives
Two 1″ 36.4-GB Ultra3 10K rpm hot plug drives (contain operating system in a
RAID 1 configuration)
Maximum Internal Storage
Minimum External Storage
78.2 GB (2 x 36.4-GB Wide Ultra3 1″ drives)
MSA1000 (4 (for non-clustered) to 6 (for clustered) x 72-GB drives depending on
model)
External Storage
Interfaces
Parallel
Serial
Not supported
1
NOTE: You can configure a second serial device to your NAS B3000 server by
installing the auxiliary serial connector that ships with the server. The
auxiliary connector attaches to a serial port B on the peripheral board
and exits the rear of the server through the auxiliary serial knockout
located directly above the dual power feeds.
Pointing Device (Mouse)
Graphics
1
Available through the “Remote Insight Board” only
Hot Plug Keyboard
External Wide Ultra2 SCSI
1
1
DA-11339
Canada — Version 7 — September 24, 2002
4
QuickSpecs
Standard Features
Graphics
StorageWorks NAS B3000 by Compaq
Integrated 1280 x 1024, 16 M colour on PCI local bus, 4-MB video memory
NOTE: The integrated video card is disabled, video is provided by the Integrated Remote Insight Board
Rack (8U = 14 inches), 4U for the Server component and 4U for the storage enclosure. Ships with sliding rails and
cable management arm
Form Factor
SANworks™ Virtual Replicator SANworks Virtual Replicator combines a rich set of innovative capabilities that
Compaq Software
by Compaq
enhance and simplify storage management. Customers can pool physical
storage and create virtual disks of up to a terabyte each. Virtual disk space can
be allocated as needed, allowing customers to respond quickly to changing
storage capacity requirements. Through virtualization, online volume growth,
snapshot and management features, the software complements the standard
capabilities within the operating system. By utilizing industry-standard server,
storage, and network-interconnect components, an organization's current and
future storage investments are protected.
SANworks Secure Path
Secure Path software is included in the base system image. SANworks Secure
Path is a high availability multi-pathing software that provides continuous data
access
NAS Data Copy
NAS Data Copy is a host-based data replication package that allows data to be
replicated over TCP/IP in either a synchronous or asynchronous mode. One-to-
one, one-to-many, many-to-many replication is supported along with failover and
failback capabilities.
NAS B3000 customers who desire to
activate NAS Data Copy after the 30 day
trial will need to order the license part
number 278546-001
Rapid Start
Compaq designed rapid deployment and configuration tool
Compaq Insight Manager XE Compaq Insight Manager XE leverages the power of the Internet to provide web-
based systems management, and plays a key role in Compaq’s strategy to
simplify IT management. Compaq Insight Manager XE reduces systems
management cost, improves operational efficiency and effectiveness, and
minimizes systems downtime.
browser-based access to in-depth instrumentation built into Compaq servers,
workstations, desktops, and portables, and send alerts to Compaq Insight
Manager XE and other management consoles in case of subsystem or
environmental failures. For additional information about the Compaq
Compaq SmartStart™
The server configuration and software integration tool from Compaq.
Minimum SmartStart version supported 5.3
Array Configuration Utility (ACU) Same easy to use yet powerful graphical user interface (GUI) configuration utility
with Smart Array Controllers and easy to navigate wizards for all Smart Array Controllers
Array Configuration Utility (ACU- Compaq Configuration Utility XE (ACU-XE) web-based software for Smart Array
XE) with Smart Array Controllers products and the StorageWorks RAID Array 4x00 systems allows for ease of
configuration and expandability for your disk arrays, remote configuration
capabilities, and multi-platform support.
ACPI 2.0 Compliant
PCI 2.2 Compliant
Indus try Standard
Compliance
PXE Support (Optional when configured with a PXE-enabled slot-based NIC)
WOL Support
Physical Address Extension (PAE) Support
Microsoft Logo certifications
DA-11339
Canada — Version 7 — September 24, 2002
5
QuickSpecs
Standard Features
Intelligent Manageability
StorageWorks NAS B3000 by Compaq
Compaq Remote Insight Lights-Out Edition Included
Automatic Server Recovery-2 (ASR-2)
Compaq Insight Manager
Compaq Insight Manager XE
Integrated Remote Console (IRC)
Integrated Management Log (IML)
Off-Line Backup Processor capability
Dynamic sector repairing and drive parametre tracking (with Smart Array controllers)
Redundant/adaptive load balancing NIC Support
Advanced Data Guarding
Availability
PCI Hot Plug with push button functionality
Continuous cooling provided by 8 Hot Plug Redundant System Fans
Integrated Smart Array Controller for RAID data protection/performance and maximum data bandwidth
Advanced Error Checking and Correcting (ECC) Technology
NOTE: Advanced ECC Memory Technology protects the data even in the event of an entire SDRAM component
failure. Embedded in the chipset design, this feature allows the use of Industry-Standard Registered
DIMMs.
Hot Plug Ultra2/Ultra3 Drive Bays
2 Redundant Hot Plug Power Supplies Standard
Redundant NIC support
Pre-Failure Warranty (covers processors, hard drives, and memory)
Internal Diagnostics Display (IDD) numerically indicates specific DIMM or processor failure.
LED display on front panel indicates power/interlock, fan, and memory/microprocessor health
Spring-loaded memory board release latches prevent unseating incidents
Serviceability
PCI Card Guide locks full length PCI cards in place during transit
Customer driven interior system fan design (all system fans interior to chassis)
Removable, internal centre panel eases access to the power supply and hard drive backplane boards
Optional High Voltage PDU cable exits chassis at a right angle to simplify cable management at rear of chassis
Power-on password
Security
Hot plug keyboard password
Diskette drive control
Diskette boot control
Network Server Mode
Security Provision
Parallel and serial interface control
Administrator’s password
Disk configuration lock
Hot plug access security
450-Watt Hot Plug Power Supply
Server Power Supply
OS Support
NOTE: Two 450-Watt Hot Plug Power Supplies ship standard with the system
Windows Powered OS (OS and all software needed for storage management is pre-configured from the factory)
NOTE: For an up-to-date listing of the latest drivers available for the StorageWorks NAS B3000, please see:
Compaq Services provides a wide range of service offerings, including a three-year, limited warranty that is fully
supported by a worldwide network of resellers and service providers, toll-free 7 x 24 hardware technical phone
support and Pre-Failure Warranty coverage of hard drives, memory and processors.
Service and Support
NOTE: Certain restrictions and exclusions apply. Consult the Compaq Customer Support Centre.
DA-11339
Canada — Version 7 — September 24, 2002
6
QuickSpecs
StorageWorks NAS B3000 by Compaq
B3000 External Storage Components
With the following components, your storage capacity and performance can be scaled to new levels:
Modular SAN Array 1000
The 4U cabinet houses up to fourteen 1″ Compaq Universal hot pluggable Ultra2 and/or Ultra3 drives.
The modular design of the MSA1000 makes it possible to add redundant controllers, redundant single port Fibre Channel I/O Modules or Fabric Switches
and storage expansion enclosures.
MSA1000 Controller
The MSA1000 Controller is an integrated RAID controller with an integrated LCD/LED status display and 128-MB read/write battery-backed cache
(expandable to 256 MB per controller). Redundant MSA1000 controllers are an option.
Key Features
•
•
•
•
•
•
•
•
Redundant controller support
Fabric, Private Loop & Public Loop Support
Auto Negotiated F, FL & L Port Login
RAID 0, 1, 1+0, 5 and ADG
2Gb/1Gb Frequency Agile
Primary & Secondary Inter-Controller Link (ICL)
Host based configuration via ACU
Remote configuration and monitoring via ACU XE (offline and remote) & CIM XE
MSA1000 Controller Management Features
•
Selective Storage Presentation: allows multiple hosts to access a single MSA1000 storage system. Host access can be defined all the way down
to a logical volume level.
•
•
•
•
Online RAID Level Migration: allows for online post-configuration change to RAID level without destroying data or volume information.
Online Capacity Expansion: lets you add storage to an operational MSA1000 — reducing expensive server downtime.
Online Volume Extension: allows for the capacity growth of existing logical volumes.
Global Online Spare: reduces the risk of data loss by facilitating automatic rebuilds after a drive failure.
Fault Tolerance
Several fault tolerant configurations, which keep data available and servers running while drives are being replaced, are supported including:
•
Advanced Data Guarding (RAID ADG): Allocates the equivalence of 2 parity drives across multiple drives and allows simultaneous write
operations.
•
•
Distributed Data Guarding (RAID 5): Allocates parity data across multiple drives and allows simultaneous write operations.
Drive Mirroring (RAID 1, (1+0 Striped Mirroring)): Allocates half of the drive array to data and the other half to mirrored data, providing two copies
of every file.
Fault Recovery
Minimizes downtime, reconstructs data, and facilitates a quick recovery from drive failure
•
On-Line Spares: If a failure occurs, recovery begins with an on-line spare and data is reconstructed automatically. One on-line spare can be
assigned per array and used across multiple arrays. It is also possible to assign different on-line spares across different arrays.
•
Array Accelerator: Onboard, battery-backed cache memory protects data in the event of a power failure. In the unlikely event of a controller failure,
the battery-backed cache will save critical user data for up to three days.
MSA1000 Fibre Channel I/O Module
The Fibre Channel I/O module provides a 2 Gb/s Fibre Channel connection from the host side into the MSA1000. The MSA1000 Fibre Channel I/O
Module includes one 2 Gb/s, Short Wave, Small Form Factor Pluggable Transceiver (SFP). A second MSA1000 Fibre Channel I/O Module can be
installed for redundancy when a redundant controller is used.
MSA Fabric Switch 6
The MSA1000 Fabric Switch 6 is a six port, 2 Gb/s Fibre Channel Fabric Switch. The MSA1000 Fabric Switch 6 replaces the standard single port Fibre
Channel connection provided by the MSA1000 Fibre Channel I/O Module. There are a total of five external fibre channel ports. Four of the external fibre
channel ports are Small Form Factor Fixed (SFF) short wave transceivers and are not removable. The fifth port requires the installation of a Small Form
Factor Pluggable (SFP) transceiver. One port is used internally by the MSA1000 controller.
DA-11339
Canada — Version 7 — September 24, 2002
7
QuickSpecs
StorageWorks NAS B3000 by Compaq
B3000 External Storage Components
MSA Fabric Switch 6 Key Features
•
•
•
•
•
•
•
2 Gb/s 6 Port Fabric Switch integrated into the MSA1000 Chassis
5 ports external, 1 port internal
4 Small Form Factor Fixed Short Wave (SFF) Transceivers, 1 Small Form Factor Short Wave Pluggable (SFP) Transceiver with LC connectors
2 Gb/1 Gb Frequency Agile
Managed Out of Band
Hot Pluggable
Efficient, space saving design
2Gb/sec Small Form Factor Pluggable (SFP) SW Transceiver Kit
2 Gb/s Small Form Factor Pluggable (SFP) SW Transceivers are industry standard connection devices, which hot plug into 2 Gb/s infrastructure
components such as 2 Gb/s Fabric Switches. StorageWorks 2 Gb/s SFP SW Transceivers support distances up to 300 metres at 2 Gb/s and 500 metres
at 1 Gb/s using multi-mode fiber optic cable.
Multi-Mode Fibre Channel Cables
Multi-Mode Fibre Channel cables provide a thin, flexible cabling solution that is immune to electromagnetic interference. Compaq offers cables to connect
the MSA1000 to both 2 Gb and 1 Gb Fibre Channel infrastructures. LC to LC cables are used when connecting the MSA1000 to other 2 Gb Fibre
Channel components because both connections will utilize small form factor transceivers. LC to SC cables are used when connecting the MSA1000 to 1
Gb Fibre Channel components. 1 Gb components use the larger GBIC style transceivers.
DA-11339
Canada — Version 7 — September 24, 2002
8
QuickSpecs
NAS B3000 Options
Processor
StorageWorks NAS B3000 by Compaq
Pentium III Xeon X900 2MB Processor Option Kit
222627-B21
NOTE: This processor option kit (PN 222627-B21) supports the StorageWorks NAS
B3000
NOTE: The increasing power of new high-performance processor technology requires
increased cooling efficiency for rack-mounted servers. The Compaq Rack 9000
series (120663-xx1 (42U), 120664-xx1 (36U), 120665-xx1 (22U)) provides
enhanced airflow for maximum cooling, allowing these racks to be fully loaded
with servers using the latest processors.
When installing a server with Pentium III Xeon processors running at speeds of
550 MHz or greater in Compaq Rack 7000 series racks (165753-xx1 (42U), and
163747-xx1 (22U)), the new processor technology requires the installation of
Compaq’s new High Airflow Rack Door Insert (327281-B21 (42U) or 157847-
B21 (22U)).
189082-B21
Memory (DIMMs)
Communications
2048 MB PC100 Registered ECC SDRAM Memory Kit (4 x 512 MB)
NOTE: Memory must be added in sets of four and be the same size.
338456-B23
338456-B24
338456-B25
Compaq NC6132 Gigabit Module 1000 SX Upgrade Module for NC3134 and NC3131
Compaq NC6133 Gigabit Module 1000 LX Upgrade Module for NC3134 and NC3131
Compaq NC3135Fast Ethernet Module 100 FX Upgrade Module for NC3134 and
NC3131
203539-B21
158575-B21
153453-B21
Compaq NC6136 Gigabit Server Adapter, 64-bit/66-MHz, PCI, 1000 SX
Compaq NC7131 Gigabit Server Adapter, 64-bit/66-MHz PCI, 10/100/1000-T
NC7132 10/100/1000tx Upgrade for NC3134
2000-100007*
2000-100009*
2000-100000*
TCP/Offload NIC
Monitors
Alacritech 1000 x 1 Single Port Gigabit Server and Storage Accelerator Copper wire
Alacritech 1000 x 1 Single Port Gigabit Server and Storage Accelerator Fibre
Alacritech 100 x 4 Quad Port Fast Ethernet Server Accelerator
Flat Panel TFT7020 Colour Monitor Two-Tone (Carbon/Silver)
Flat Panel TFT5015 Colour Monitor (Opal)
Flat Panel TFT5015 Colour Monitor Two-Tone (Carbon/Silver)
Flat Panel TFT5030 Colour Monitor Two-Tone (Carbon/Silver)
P720 CRT Monitor Two-Tone (Carbon/Silver)
V720 CRT Monitor (Opal)
253216-001
234043-001
234044-001
228134-001
244373-xxx
232943-xxx
232944-xxx
228114-xxx
228113-xxx
239286-xxx
239287-xxx
152991-xxx
217248-001
221546-001
V720 CRT Monitor Two-Tone (Carbon/Silver)
V570 CRT Monitor (opal)
V570 CRT Monitor Two-Tone (Carbon/Silver)
S720 CRT Monitor (Opal) (Lite-On)
S720 CRT Monitor Two Tone (Carbon/Silver) (Lite-On)
S710 Colour Monitor
TFT5010R Flat Panel Monitor
TFT 5600- RKM Keyboard/Monitor/Mouse 1U Kit
DA-11339
Canada — Version 7 — September 24, 2002
9
QuickSpecs
NAS B3000 Options
Tape Drives
StorageWorks NAS B3000 by Compaq
External DAT Tape Drives
157770-001
External 20/40-GB DAT DDS-4 Tape Drive
NOTE: Please see the Compaq 20/40-GB DAT Tape Drive QuickSpecs for additional options such as host bus
adapters, controllers, cassettes, and for an up-to-date listing of the latest O/S Support details, please see
External AIT Tape Drives
External AIT 35-GB,LVD Tape Drive
216885-001
NOTE: Please see the Compaq AIT 35-GB, LVD Tape Drive QuickSpecs for additional options such as adapters,
controllers, and cassettes, and for an up-to-date listing of the latest O/S Support details, please see the
following:
157767-001
External AIT 50-GB Tape Drive
NOTE: Please see the Compaq AIT 50-GB Tape Drive QuickSpecs for additional options such as adapters,
controllers, and cassettes, and for an up-to-date listing of the latest O/S Support details, please see the
following:
External DLT / SDLT Tape Drives
340744-B22
External 20/40-GB DLT Drive (opal)
NOTE: Please see the Compaq 20/40-GB DLT Drive QuickSpecs for additional options such as data and cleaning
cartridges, and for an up-to-date listing of the latest O/S Support details, please see the following:
146197-B22
External 40/80-GB DLT Enhanced Drive
NOTE: Please see the Compaq 40/80-GB DLT Drive QuickSpecs for additional options such as host bus
adapters, controllers, cassettes, and for an up-to-date listing of the latest O/S Support details, please see
SDLT 110/220 External
192103-001
NOTE: Please see the Compaq SDLT 110/220-GB Tape Drive QuickSpecs for additional options such as
adapters, controllers, and media, and for an up-to-date listing of the latest O/S Support details, please see
External DAT Autoloader
166505-001
20/40-GB DAT 8 Cassette Autoloader External
NOTE: Please see the Compaq 20/40-GB DAT DDS-4 8 Cassette Autoloader QuickSpecs for additional options
such as adapters, controllers, and cassettes, and for an up-to-date listing of the latest O/S Support details,
DA-11339
Canada — Version 7 — September 24, 2002
10
QuickSpecs
StorageWorks NAS B3000 by Compaq
NAS B3000 Options
NOTE: Compaq Tape Storage Enclosures and Arrays are compatible with Compaq Internal tape drive options.
Please see the QuickSpecs for each Tape Enclosure and Array Model to check for tape drive
compatibility. The URL’s are provided below.
Tape Storage Enclosures and
Arrays
3U RM Storage Enclosure
3U RM Storage Enclosure, Model 0
230603-B21
230604-B21
230605-B21
230606-B21
3U RM Storage Enclosure, Model 2 AIT
3U RM Storage Enclosure, Model 2 DLT
3U RM Storage Enclosure, Model 2 SDLT
NOTE: Please see the Compaq 3U RM Storage Enclosure QuickSpecs for additional options such as adapters,
controllers, and cassettes, and for an up-to-date listing of the latest O/S Support details, please see the
following:
DLT Tape Array III
DLT Tape Array III Model 0
DLT Tape Array III Model 40/80-4
DLT Tape Array III SDLT-4
168047-001
161140-001
229760-001
NOTE: Please see the StorageWorks DLT Tape Array III QuickSpecs for additional information including Tape
Drives, Cartridges, Controllers, and SCSI Cables and additional options needed for a complete solution at:
TA1000 AIT Tape Array
TA1000 AIT Tape Array, Model 5, Rackmount
TA1000 AIT Tape Array, Model 10, Rackmount
195479-001
175005-001
NOTE: Please see the Compaq TA1000 AIT Tape Array QuickSpecs for additional information including Tape
Drives, Cartridges, Controllers, and SCSI Cables and additional options needed for a complete solution at:
Tape Storage Enclosure Cable Kits
LVD Cable Kit, VHDCI/HD68
NOTE: For use with the 3U RM Storage Enclosure and DLT Tape Array III only.
168048-B21
242381-B21
LVD Cable Kit, HD68/HD68
NOTE: For use with the 3U RM Storage Enclosure and DLT Tape Array III only.
Tape Automation
SSL2020 Automated AIT Mini-Library
SSL2020 AIT Mini-Library 1 drive, 20 slot Rackmount
SSL2020 AIT Mini-Library 2 drive, 20 slot Rackmount
SSL2020 AIT Library Pass Thru with Transport
SSL2020 AIT Library Pass Thru Extender
175196-B21
175196-B22
175312-B21
175312-B22
175197-B21
AIT 50 GB Drive Add-On LVD Drive for SSL2020 AIT Library
Required Adapters/Controllers for SSL2020 AIT Mini-Library
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter
SAN Access Module for Smart Array 5302 Controller
Smart Array 5302/FC Controller
129803-B21
216687-B21
216688-B21
NOTE: Please see the SSL2020 Automated AIT Tape Library Solution QuickSpecs for additional information
including Upgrade Kits, Accessories, and SCSI Cable Kits and additional options needed for a complete
solution at:
DA-11339
Canada — Version 7 — September 24, 2002
11
QuickSpecs
NAS B3000 Options
Tape Automation (continued)
StorageWorks NAS B3000 by Compaq
TL891DLX Automated DLT Tape Library
TL891DLX DLT Library, 1 drive Rack, LVD
TL891DLX DLT Library, 2 drive Rack, LVD
157305-B21
157305-B22
157303-B21
157304-B21
Add-On 40/80 GB Drive for TL891DLX, LVD
Add-On 40/80 GB Drive for TL8x1HVD
Required Adapters/Controllers for TL891DLX Automated DLT Tape Library
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter
SAN Access Module for Smart Array 5302 Controller
Smart Array 5302/FC Controller
129803-B21
216687-B21
216688-B21
NOTE: Please see the StorageWorks TL891DLX Automated DLT Tape Library QuickSpecs for additional
information including Upgrade Kits, Accessories, and SCSI Cable Kits and additional options needed for a
complete solution at:
MSL5026 Library
MSL5026DLX Library
MSL5026DLX, 1 40/80-GB DLT, LVD Rackmount
MSL5026DLX, 2 40/80-GB DLT, LVD Rackmount
231891-B21
231891-B22
MSL5026SL Library
MSL5026SL Library, SDLT 110/220, 1 Drive, LVD, Rackmount
MSL5026SL Library, SDLT 110/220, 2 Drives, LVD, Rackmount
MSL5K Field Upgrade SDLT 110/220 Drive, LVD
231892-B21
231892-B22
231823-B22
Required Adapters for MSL5026 Library
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter
129803-B21
NOTE: Please see the StorageWorks MSL5026DLX or MSL5026SL Library QuickSpecs for additional information
including Upgrade Kits, Accessories, and SCSI Cable Kits and additional options needed for a complete
solution at:
TL895 DLT Library
TL895 (96 slot) library unit, 2 drive
TL895 (96 slot) library unit, 3 drive
TL895 (96 slot) library unit, 4 drive
TL895 (96 slot) library unit, 5 drive
TL895 (96 slot) library unit, 6 drive
TL895 (96 slot) library unit, 7 drive
DLT7000 drive upgrade kit
349350-B22
349350-B23
349350-B24
349350-B25
349350-B26
349350-B27
349351-B21
Required Adapters for TL895 DLT Library
StorageWorks Dual Channel Ultra-Wide Differential Library Host Bus Adapter
157299-B21
NOTE: Please see the TL895 Automated DLT Tape Library Solution QuickSpecs for additional information
including Upgrade Kits, Accessories, ProLiant™ Connectivity Kits, Host Bus Adapters, SCSI Cable Kits,
NOTE: This Web site is available in English only.
DA-11339
Canada — Version 7 — September 24, 2002
12
QuickSpecs
NAS B3000 Options
Tape Automation (continued)
StorageWorks NAS B3000 by Compaq
Enterprise 9000 System Library
ESL9198DLX
194993-B21
194993-B22
194993-B24
194993-B28
ESL9198 Enterprise Library LVD, 0 Drives
ESL9198DLX Enterprise Library 2 40/80 Drive
ESL9198DLX Enterprise Library 4 40/80 Drive
ESL9198DLX Enterprise Library 8 40/80 Drive
ESL9000 Add-On 40/80-GB DLT Drive, LVD in Hot Plug Canister (ESL9198DLX only)
221248-B21
Required Adapters for ESL9198DLX
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter
129803-B21
NOTE: 64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter is required to support
the LVD based libraries (ESL9198DLX).
NOTE: Please see the StorageWorks ESL9198DLX Enterprise Library QuickSpecs for additional information
including Tape Drives, Cartridges, Controllers, and SCSI Cables and additional options needed for a
NOTE: This Web site is available in English only.
ESL9198SL
194993-B21
ESL9198 Enterprise Library LVD, 0 Drives
234618-B21
234618-B22
234617-B21
ESL9198SL Enterprise Library, LVD 4 110/220 SDLT Drives
ESL9198SL Enterprise Library, LVD 8 110/220 SDLT Drives
ESL9000 Field Upgrade SDLT 110/220, LVD Drive (ESL9198SL, ESL9326SL only)
NOTE: Please see the StorageWorks ESL9198SL Enterprise Library QuickSpecs for additional information
including Tape Drives, Cartridges, Controllers, and SCSI Cables and additional options needed for a
complete solution at:
ESL9326DX
146205-B21
ESL9326DX, 0 Drive Unit
161265-B23
161265-B24
161265-B28
161267-B21
234617-B22
ESL9326DX Enterprise Library 6 40/80 Drive
ESL9326DX Enterprise Library 8 40/80 Drive
ESL9326DX Enterprise Library 16 40/80 Drive
ESL9000 Add-On 40/80-GB DLT Drive, HVD in Hot Plug Canister (ESL9326DX only)
ESL9000 Field Upgrade SDLT 110/220, HVD Drive (ESL9326D/DX only)
NOTE: Please see the StorageWorks ESL9326DX Enterprise Library QuickSpecs for additional information
including Tape Drives, Cartridges, Controllers, and SCSI Cables and additional options needed for a
NOTE: This Web site is available in English only.
ESL9326SL
234488-B21
ESL9326SL Enterprise Library LVD 0 Drives
234615-B21
234615-B22
234615-B26
234617-B21
ESL9326SL Enterprise Library LVD 6 110/220 DSLT Drives
ESL9326SL Enterprise Library LVD 8 110/220 DSLT Drives
ESL9326SL Enterprise Library LVD 16 110/220 DSLT Drives
ESL9000 Field Upgrade SDLT 110/220, LVD Drive (ESL9198SL, ESL9326SL only)
NOTE: Please see the StorageWorks ESL9326SL Enterprise Library QuickSpecs for additional information
including Tape Drives, Cartridges, Controllers, and SCSI Cables and additional options needed for a
complete solution at:
DA-11339
Canada — Version 7 — September 24, 2002
13
QuickSpecs
StorageWorks NAS B3000 by Compaq
NAS B3000 Options
StorageWorks Options
Fibre Channel SAN Switch/8 with Fabric Operating Software
158222-B21
158223-B21
230616-B21
230617-B21
176219-B21
240602-B21
212776-B21
Fibre Channel SAN Switch/16 with Fabric Operating Software
StorageWorks SAN Switches Integrated/32
StorageWorks SAN Switches Integrated/64
StorageWorks Fibre Channel SAN Switches 8-EL
StorageWorks San Switch 2/16
StorageWorks Fibre Channel SAN Switches 16-EL
Compaq UPS R1500 XR (100 to 127)
Compaq UPS R3000 XR (120V)
Compaq UPS R3000 XR (208V)
Rackmountable UPS R6000 (208V)
Uninterruptible Power Systems –
Rack
204404-001
192186-001
192186-002
347207-001
347224-B21
R6000 Extended Runtime Module
NOTE: Available for the UPS R6000 Models only.
Extended Runtime Module, R3000 XR
NOTE: Available for the UPS R3000 XR Models only.
192188-B21
218971-B21
192185-B21
192189-B21
Extended Runtime Module, R1500 XR
NOTE: Available for the UPS R1500 XR Models only.
Six-Port Card
NOTE: Available for the new UPS “XR” Models only.
SNMP/Serial Port Card
NOTE: Available for the new UPS “XR” Models only.
SNMP-EN Adapter
347225-B21
388643-B21
123508-B21
123509-B21
High to Low Voltage Transformer (250VA)
Multi-Server UPS Card
Scalable UPS Card
Compaq Power Distribution Unit-16A (200 to 240V)
Compaq Power Distribution Unit-24A (200 to 240V)
Compaq Power Distribution Unit-40A (200 to 240V)
Compaq Power Distribution Unit-24A (100 to 127V)
Compaq Dual Input Power Distribution Unit-24A High Voltage
Compaq High Voltage PDU Right Angled Cable Kit (IEC13-IEC14)
Rackmountable PDUs – 1U / 0U
207590-B21
207590-D72
207590-B23
207590-D71
191186-001
142257-004
NOTE: The 10-Amp AC cord, which ships standard with the Compaq ProLiant DL580, utilizes a right angle plug
on the server side (the side that plugs into the server) to avoid interference with the Cable Management
Arm. Compaq High Voltage PDUs ship standard with 15-Amp AC cords that incorporate straight plugs on
the server side. The optional Compaq High Voltage PDU Right Angled Cable Kit (142257-004) provides a
right angle version of the 15-Amp AC cord. When deploying Compaq High Voltage PDUs with the
Compaq ProLiant DL580, you may choose to simplify cable management at the rear of the server chassis
by installing this option kit.
DA-11339
Canada — Version 7 — September 24, 2002
14
QuickSpecs
StorageWorks NAS B3000 by Compaq
NAS B3000 Options
CarePaq™ Services
Remedial Services
Compaq Services will also provide remedial services for ongoing maintenance.
Software Product Services
•
•
•
Stand-alone telephone support
Software Product Subscription
Hardware Product Services
•
•
•
On-site Maintenance (includes warranty support)
Response time upgrades during the warranty period
Post-warranty coverage
Warranty Upgrade Options
•
•
•
Response – Upgrade on-site response from next business day to same day 4-hours
Coverage – Extend hours of coverage from 9 hours x 5 days to 24 hours x 7 days
Duration – Select duration of coverage for a period of 1year to multi-years
B3000 CarePaq Price Band Information
NOTE: This Web site is available in English only.
Fully customized remedial services are also available. Please contact your Customer Services Department for
assistance.
DA-11339
Canada — Version 7 — September 24, 2002
15
QuickSpecs
Storage
StorageWorks NAS B3000 by Compaq
DRIVE SUPPORT
Quantity
Supported
Position
Supported
Controller
Removable Media
1.44MB Diskette Drive
IDE CD-ROM Drive
Up to 1
Up to 1
C
B
Integrated
Integrated IDE
Tape Drives
Internal AIT 50-GB, Hot Plug
Internal AIT 35-GB, LVD, Hot Plug
Internal 20/40-GB DAT, Hot Plug
Up to 1
Up to 2
0 & 1 or 2 & 3
External
Integrated Smart Array Controller
Smart Array 5300 Controller
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter
64-Bit/66-MHz Single Channel Wide Ultra3 SCSI Adapter
Integrated Smart Array Controller
External AIT 50-GB Tape Drive
External AIT 35-GB, LVD Tape Drive
Dual Channel Wide-Ultra SCSI-3 Adapter
Wide-Ultra SCSI-3 Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter
64-Bit/66-MHz Single Channel Wide Ultra3 SCSI Adapter
Dual Channel Wide-Ultra SCSI-3 Adapter
Wide-Ultra SCSI-3 Adapter
64-bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter
64-bit/66-MHz Single Channel Wide Ultra3 SCSI Adapter
Integrated Smart Array Controller
1 to 4
External
External
External
DLT Tape Array III
SDLT 110/220-GB, External
Up to 2
Up to 3
External 40/80-GB DLT Enhanced
External 20/40-GB DLT
Dual Channel Wide-Ultra SCSI-3 Adapter
Wide-Ultra SCSI-3 Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter
64-Bit/66-MHz Single Channel Wide Ultra3 SCSI Adapter
Compaq Wide-Ultra SCSI-3 Adapter
64-Bit Dual Channel Wide Ultra2 SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter
64-Bit Dual Channel Wide Ultra2 SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter
SAN Access Module for Smart Array 5302 Controller
Smart Array 5302/FC Controller
Up to 1
External
TA1000 AIT Tape Array
SSL2020 AIT Mini-Library
2 drives per SCSI External
channel
2 drives per SCSI External
channel
64-Bit Dual Channel Wide Ultra2 SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter
MSL5026DLX (40/80-GB DLT based)
and MSL5026SL (SDLT-based)
Library
2 drives per SCSI External
channel
Compaq Wide-Ultra SCSI Adapter
64-Bit Dual Channel Wide Ultra2 SCSI Adapter
TL895 (96 slot) DLT Library (2 - 7
Drives)
2 drives per SCSI External
channel
64-Bit Dual Channel Wide Ultra2 SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter
SAN Access Module for Smart Array 5302 Controller
Smart Array 5302/FC Controller
TL891DLX DLT Library
DA-11339
Canada — Version 7 — September 24, 2002
16
QuickSpecs
StorageWorks NAS B3000 by Compaq
Technical Specifications
Server Unit Rack Dimensions
*Dimensions (H x W x D)
6.94 x 19 x 28.3 in/ 17.6 x 48.3 x 71.9 cm
*Each StorageWorks NAS B3000 consists
of a differing amount of Servers and
Storage based on model choice. These
dimensions represent one (1) server.
Chassis Footprint (H x W x D) 6.94 x 19 x 25 in/17.6 x 48.3 x 63.5 cm
Weight
66 lb/29.9 kg
No hard drives installed,
one power supply
Input Requirements (per power Rated Input Voltage
90 to 120 VAC/200 to 240 VAC
50 to 60 Hz
supply)
Rated Input Frequency
Input Power
600W @ 110 VAC/600 W @ 220 VAC
7A (90 VAC), 5A (120 VAC), 3A (210 VAC)
Rated Input Current
BTU Rating
2291 BTU
SCSI Connector
One 68-pin connector
supporting Wide Ultra2 SCSI
Power Supply Output Power Rated Steady-State Power
(per power supply)
450W/450W (lowline/highline)
480W/480W (lowline/highline)
50° to 95° F/10° to 35° C
-20° to 140° F/-29° to 60° C
-22° to 122° F/-30° to 50° C
20% to 80%
Temperature Range
Operating
Non-operating
Shipping
Relative Humidity
Operating
(non-condensing)
Non-operating
101.7° F/38.7° C
5% to 90%
Maximum Wet Bulb
Temperature
Acoustic Noise
Idle
(Fixed Disk Drives Spinning)
Storage Component Dimensions
*Dimensions (H x W x D)
6.94 x 19.0 x 19.5 in
66 lb/29.9 kg
*Each StorageWorks NAS B3000 consists
of a differing amount of Servers and
Storage based on model choice. These
dimensions represent one (1) MSA1000
Storage Component.
Weight
DA-11339
Canada — Version 7 — September 24, 2002
17
QuickSpecs
StorageWorks NAS B3000 by Compaq
Technical Specifications
1.44MB Diskette Drive
Diskette Size
3.5 in
LED Indicators (front panel)
Green
Read/Write Capacity per
1.44 MB/720 KB
Diskette (high/low density)
Drive Supported
Drive Height
One
One-third
300 rpm
Drive Rotation
Transfer Rate (high/low)
Bytes/Sector
500/250 Kb/s
512
Sectors/Track (high/low)
Tracks/Side (high/low)
Access Times
18/9
80/80
Track-to-Track (high/low)
Average (high/low)
Settling Time
Latency Average
80/80
3/6 ms
94/169 ms
15 ms
100 ms
Cylinders (high/low)
Read/Write Heads
Two
Hard Drives
Wide Ultra3 SCSI Hard Drives 1-inch
72.8-GB 10,000 rpm
36.4-GB 10,000 rpm
18.2-GB 10,000 rpm
36.4-GB 15,000 rpm
18.2-GB 15,000 rpm
DA-11339
Canada — Version 7 — September 24, 2002
18
QuickSpecs
StorageWorks NAS B3000 by Compaq
Technical Specifications
24X Max (or higher) IDE
CD-ROM Drive Slim Line
Disk
Applicable Disk
CD-ROM (Mode 1 and 2)
CD-DA, CD-XA (Mode 2, Form 1 and 2)
Photo CD (Single and Multi-session)
Mixed Mode (Audio and Data combined)
540 MB (Mode 1, 12 cm)
650 MB (Mode 2, 12 cm)
4.7 in, 3.15 in/12 cm, 8 cm
4200 rpm maximum
0.6 in/15 mm diametre
1.2 mm
Capacity
Diametre
Rotational Speed
Centre Hole
Thickness
Track Pitch
Mode 1
1.6 µm
Block Size
2,048
Mode 2
2,340, 2,336, 1,024 bytes
2,352 bytes
CD-DA
CD-XA
2,328 bytes
Interface
IDE (ATAPI)
Random
Access Times (typical)
100 ms
Full-Stroke
Line-Out
2000 ms
Audio Output Level
Data Transfer Rate
0.7 VRMS at 47 kOhms
0.6 VRMS at 32 kOhms (maximum volume)
150 KB/s (single)
Headphone
Sustained
Burst
2100 to 3600 KB/s
Cache Buffer
128 KB
Start-up Time (typical)
Stop Time
< 7 seconds
< 4 seconds
Type
Laser Parametres
Semiconductor Laser GaA1As
780 ± 25 nm
Wave Length
Divergence Angle
Output Power
Temperature
Humidity
53.5° ± 1.5°
0.14 mW
Operating Conditions
Dimensions
41° to 113° F/5° to 45° C
10% to 80%
(H x W x D, maximum)
Weight
1.69 x 5.75 x 8.19 in/4.29 x 15 x 20.8 cm
2.66 lb/1.2 kg
DA-11339
Canada — Version 7 — September 24, 2002
19
QuickSpecs
StorageWorks NAS B3000 by Compaq
Technical Specifications
Integrated Smart Array Controller
Data Compatible with all Smart Array Controllers Yes
Instant Upgrades to other Smart Array Controllers Yes
Consistent Software Manageability Tools
PCI Bus
Yes
32-bit, 33 MHz (integrated on peripheral board)
PCI Peak Data Transfer Rate
SCSI Protocols Supported
SCSI Peak Data Transfer Rate
133 MB/s
Ultra2, Wide-Ultra
80 MB/s
NOTE: For ProLiant servers having TWO internal drive bays on separate SCSI ports: SCSI Peak Data Transfer
Rate is 160 MB/s total; 80 MB/s per channel and Channels is 2.
Channels
2
NOTE: For ProLiant servers having two internal drive bays on separate SCSI ports: SCSI Peak Data Transfer
Rate is 160 MB/s total; 80 MB/s per channel and Channels is 2. The second channel on the DL580 is for
external tape support only.
SCSI Ports (external/internal)
1/1
NOTE: For ProLiant servers having two internal drive bays on separate SCSI ports: SCSI Peak Data Transfer
Rate is 160 MB/s total; 80 MB/s per channel and Channels is 2. The DL580 has a SCSI port at the back
of the server for external tape support only.
Drives Supported (maximum)
Maximum = total number of drives
NOTE: Maximum is the total number of internal drives on each specific ProLiant server.
Cache
8-MB read only
RAID Support
0, 1, 1+0, 5
32
Logical Drives (maximum)
Online Configuration
Online Capacity Expansion
Logical Drive Capacity Extension
Online Stripe Size Migration
Online RAID Level Migration
Online Spare Support
Automatic Data Recovery
Drive Roaming
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Redundant Controllers
No
DA-11339
Canada — Version 7 — September 24, 2002
20
QuickSpecs
StorageWorks NAS B3000 by Compaq
Technical Specifications
Compaq NC3134 Fast Ethernet
NIC 64 PCI Dual Base 10/100
Network Interface
Compatibility
10Base-T/100Base-TX
PCI v2.2, IEEE 802.3/802.3u compliant
64-bit/66-MHz bus-master PCI
Data Transfer Method
Network Transfer Rate
10Base-T (Half-Duplex),
10Base-2
10 Mb/s
10Base-T (Full-Duplex)
100Base-TX (Half-Duplex)
100Base-TX (Full-Duplex)
Dual RJ-45
20 Mb/s
100 Mb/s
200 Mb/s
Connector
I/O Address and Interrupt
Cable Support
Automatic Configuration
10Base-T / 100Base-TX
Categories 3, 4 or 5 UTP (2 or 4 pair); up to 328
feet (100 metres)
Category 5 UTP (2 pair); up to 328 feet (100
metres)
© 2002 Compaq Canada Corporation. All rights reserved. Printed in Canada.
Compaq, the Compaq logo, CarePaq, Compaq Insight Manger, ProLiant, SANworks, SmartStart, and StorageWorks are registered trademarks or trademarks
of Compaq Information Technologies Group, L.P. in the U.S. and/or other countries. Microsoft and Windows are registered trademarks or trademarks of
Microsoft Corporation in the U.S. and/or other countries. Intel, Pentium, Xeon and the Intel Inside Logo are registered trademarks or trademarks of Intel
Corporation in the U.S. and/or other countries. Linux is a registered trademark or trademark of Linus Torvalds in the U.S. and/or other countries. UNIX is a
registered trademark or trademark of The Open Group in the U.S. and/or other countries. NetWare and Novell are registered trademarks or trademarks of
Novell Inc., in the U.S. and/or other countries. All other product names mentioned herein may be trademarks of their respective companies.
Compaq shall not be liable for technical or editorial errors or omissions contained herein. The information is provided “as is” without warranty of any kind and
is subject to change without notice. The warranties for Compaq products are set forth in the express limited warranty statements accompanying such
products. Nothing herein should be construed as constituting an additional warranty.
DA-11339
Canada — Version 7 — September 24, 2002
21
|