Cooper Lighting Indoor Furnishings 124T5HO User Manual

®
COOPER LIGHTING - METALUX  
DESCRIPTION  
Type  
The Ovation Series is a complete family of recessed direct/indirect  
Catalog #  
luminaires featuring pleasant modern architectural styling, computer-  
designed optics and the latest energy efficient lamp and ballast technology.  
The luminaire combines a matte white indirect reflector and a perforated  
direct lamp shield providing optimum brightness control. Components are  
dropped below the ceiling plane for an aggressive architectural appearance  
in the finished space. Carefully balanced design elements combine to  
provide an efficient and exciting, high performance alternative to traditional  
general lighting. Ovation is an excellent choice for a wide variety of  
commercial applications.  
Project  
Date  
Comments  
Prepared by  
SPECIFICATION FEATURES  
lampholders ensure postive lamp  
retention. UL/CUL listed. Suitable  
Nominal 3" deep housing is die  
A ... Construction  
E ... Reflectors  
Indirect reflector has high  
for damp locations.  
formed of code gauge, prime cold  
rolled steel. Heavy gauge end  
C ... Ballast Access  
reflectance baked matte white  
enamel finish for luminous  
plates are securely attached with  
screws for strength and rigidity  
uniformity. Positively retained  
direct lamp shield is constructed of  
heavy gauge perforated steel.  
Shields are combined with a high  
reflectance painted after fabrica-  
tion finish and milky white overlay  
diffuser for visual comfort. All  
reflectors are precision formed in a  
computer-controlled operation.  
Ballast can be accessed from  
below.  
and the elimination of gaps. Four  
auxiliary fixture end suspension  
D ... Finish  
points are provided. KOs for  
continuous row wiring. Large  
access plate for supply connection.  
Durable cold rolled steel with  
multistage, iron phosphate  
pretreatment and white enamel  
finish to ensure maximum bonding  
and rust inhibition.  
B ... Electrical*  
Ballasts are Class "P" and are  
positively secured. Rotor-lock  
2RDI  
114T5  
214T5  
314T5  
124T5HO  
224T5HO  
324T5HO  
A
B
C
E
E
D
3"  
[77mm]  
T5 OR T5HO LAMPS  
2' X 2' Recessed  
Direct/Indirect  
Center-Mount  
Drop Basket  
23-3/4"  
[603 mm]  
MOUNTING DATA  
LAMP CONFIGURATIONS  
3" [77mm]  
3" [77mm]  
3-5/8"  
[93mm]  
3-5/8"  
[93mm]  
T5  
8-1/4"  
3-1/4"  
[83mm]  
[210mm]  
23-3/4" [603mm]  
8-1/4"  
[210mm]  
23-11/16"  
[602mm]  
23-3/4" [603mm]  
Wiring  
Access Plate  
7/8"  
[22mm]  
1-1/2"  
3" [77mm]  
2-1/2"  
K.O. (2)  
[38mm]  
[64mm]  
3-5/8"  
[93mm]  
3-1/4"  
[88mm]  
1-5/8"  
[41mm]  
23-3/4"  
[603mm]  
8-1/4"  
[210mm]  
23-3/4" [603mm]  
T5 MODEL  
6-9/16"  
[168mm]  
23-7/16" [596mm]  
CEILING COMPATIBILTY  
G
T
F
Ceiling  
Type**  
Exposed Grid  
Concealed T  
Slot Grid  
Trim  
Type  
G
G or T  
G or T  
***  
Grid/Lay-in  
Standard  
Slot Grid  
Drywall Frame  
Kit  
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING  
Flange  
TO LOCAL, STATE OR FEDERAL LAWS  
Safe and convenient means of  
disconnecting power  
Specifications and Dimensions subject to change without notice.  
ADF032747  
08/02/2008 3:16:54 PM  
Consult your representative for additional options and finishes.  
 
2RDI  
PHOTOMETRICS  
Candela  
Candela  
2RDI-224T5RPD  
2RDI-324T5RPD  
Electronic Ballast  
Electronic Ballast  
o
o
Angle  
0
5
Along II  
45  
Across  
631  
629  
625  
616  
604  
589  
570  
549  
524  
496  
466  
433  
398  
360  
318  
280  
242  
197  
0
Angle  
0
5
Along II  
45  
Across  
(2) F24T5HO/830  
lamps  
1750 lumens  
(2) F24T5HO/830  
Lamps  
1750 Lumens  
631  
630  
622  
608  
588  
563  
533  
497  
457  
412  
364  
312  
257  
202  
150  
105  
65  
631  
630  
623  
612  
596  
576  
553  
525  
494  
460  
424  
385  
344  
302  
259  
215  
175  
134  
0
1001  
1002  
989  
967  
935  
894  
847  
789  
724  
652  
575  
491  
403  
314  
230  
159  
97  
1001  
998  
988  
969  
943  
910  
871  
825  
774  
717  
658  
596  
531  
463  
394  
325  
257  
197  
0
1001  
996  
988  
974  
953  
926  
894  
858  
816  
770  
722  
669  
611  
549  
482  
417  
354  
291  
0
10  
15  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
10  
15  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
Spacing criterion:  
(II) 1.3 x mounting  
height, () 1.3 x  
mounting height  
Spacing criterion:  
(II) 1.3 x mounting  
height, () 1.3 x  
mounting height  
||  
||  
Efficiency 63.9%  
Efficiency 61.7%  
Test Report:  
2RDI324T5RPD.IES  
Test Report:  
2RDI224T5RPD.IES  
LER = FL42  
LER = FL39  
Yearly Cost of 1000  
lumens, 3000 hrs at  
.08 KWH = $5.72  
Yearly Cost of 1000 75  
lumens, 3000 hrs at  
.08 KWH = $6.11  
80  
85  
90  
32  
0
48  
0
Coefficients of Utilization  
Coefficients of Utilization  
Effective floor cavity reflectance  
Effective floor cavity reflectance  
20%  
20%  
rc  
rw  
RCR  
0
1
2
3
4
5
6
80%  
70 50 30 10  
70%  
70 50 30 10  
50%  
50 30 10  
30%  
50 30 10  
10%  
50 30 10  
0%  
0
rc  
rw  
RCR  
0
1
2
3
4
5
6
80%  
70 50 30 10  
70%  
70 50 30 10  
50%  
50 30 10  
30%  
50 30 10  
10%  
50 30 10  
0%  
0
76 76 76 76  
68 64 61 58  
61 55 50 46  
56 48 42 38  
51 42 36 32  
47 38 32 27  
43 34 28 24  
40 31 25 21  
37 28 22 18  
34 26 20 16  
32 24 18 15  
74 74 74 74  
66 63 60 57  
60 54 50 46  
54 47 42 38  
49 42 36 31  
45 37 31 27  
42 33 28 23  
39 30 25 21  
36 27 22 18  
34 25 20 16  
31 23 18 15  
71 71 71  
60 58 55  
52 48 45  
45 41 37  
40 35 31  
36 31 27  
32 27 23  
29 24 20  
27 22 18  
24 20 16  
23 18 15  
68 68 68  
58 55 54  
50 46 44  
43 39 36  
38 34 31  
34 30 26  
31 26 23  
28 24 20  
26 21 18  
24 19 16  
22 18 15  
65 65 65  
55 54 52  
48 45 43  
42 38 35  
37 33 30  
33 29 26  
30 26 23  
27 23 20  
25 21 18  
23 19 16  
21 17 15  
64  
51  
41  
34  
29  
25  
21  
19  
17  
15  
13  
74 74 74 74  
66 62 59 56  
59 53 48 44  
54 46 41 36  
49 41 35 30  
45 36 30 26  
41 33 27 22  
38 29 24 20  
36 27 21 18  
33 25 19 16  
31 23 18 14  
72 72 72 72  
64 61 58 55  
57 52 48 44  
52 45 40 36  
47 40 34 30  
43 36 30 26  
40 32 26 22  
37 29 23 20  
35 26 21 17  
32 24 19 16  
30 22 17 14  
69 69 69  
58 55 53  
50 46 43  
43 39 35  
38 33 30  
34 29 25  
31 26 22  
28 23 19  
26 21 17  
23 19 16  
22 17 14  
66 66 66  
55 53 52  
48 45 42  
42 38 35  
37 33 29  
33 29 25  
30 25 22  
27 23 19  
25 20 17  
23 19 15  
21 17 14  
63 63 63  
53 52 50  
46 43 41  
40 37 34  
35 32 29  
32 28 25  
29 25 22  
26 22 19  
24 20 17  
22 18 15  
21 17 14  
62  
49  
39  
33  
27  
23  
20  
18  
16  
14  
13  
7
8
9
10  
7
8
9
10  
Zonal Lumen Summary  
Typical VCP Percentages  
Height Along  
Zonal Lumen Summary  
Typical VCP Percentages  
Height Along  
Height Across  
Height Across  
Zone  
0-30  
0-40  
0-60  
0-90  
0-180  
Lumens %Lamp  
%Fixture  
23.1  
38.3  
70.3  
100.0  
100.0  
Room Size (Ft.)  
20 x 20  
30 x 30  
30 x 60  
60 x 30  
8.5'  
67  
61  
57  
61  
55  
10.0'  
75  
66  
60  
65  
8.5'  
60  
52  
41  
56  
44  
10.0'  
69  
58  
46  
62  
Zone  
0-30  
0-40  
0-60  
0-90  
0-180  
Lumens %Lamp  
%Fixture  
23.5  
38.9  
71.1  
100.0  
100.0  
Room Size (Ft.)  
20 x 20  
30 x 30  
30 x 60  
60 x 30  
8.5'  
59  
52  
47  
52  
46  
10.0'  
66  
56  
50  
56  
49  
8.5'  
51  
43  
33  
47  
35  
10.0'  
61  
49  
37  
43  
39  
789  
15.0  
24.9  
45.4  
63.9  
63.9  
499  
827  
14.3  
23.6  
43.4  
61.7  
61.7  
1306  
2385  
3353  
3353  
1519  
2160  
2160  
58  
48  
60 x 60  
60 x 60  
ORDERING INFORMATION  
SAMPLE NUMBE R: 2RDI-214T5RPD-120V-EBT1-U  
Number  
Lamp Shield  
RPD=RoundPerforated  
Steel Below Ceiling Lamp  
Shield  
RPD/TBW=Round  
Perforated Below Ceiling  
Lamp Shield withThin  
BladeWhite Baffle  
Packaging  
U=Unit Pack  
PALC=Job Pack,  
Options  
RIF1=Radio Interference  
Suppressor  
2 = 2' Width  
BallastType(2)  
EBT =T5 Linear Electronic Program Rapid  
StartTotal Harmonic Distortion < 10%  
No. of Ballast  
of Lamps  
(Not included)  
1=1 Lamp  
2=2 Lamp  
3=3 Lamp  
Ovation Series  
RDI=Recessed  
Direct/Indirect  
EQ-Clip-U=T-Bar EQ Clip  
in carton  
(Order Individually as Accessory.  
Use Four Per Fixture.)  
1,2 or 3  
DLS=Digital Lighting System Dimming  
DF-22-W  
=Drywall Frame Kit  
(Order Individually as Accessory.)  
REP=Riveted Endplates, for use in  
NewYork City.  
Trim Type  
Leave Blank=Grid/Lay-in  
(Standard)  
Voltage(2)  
120V=120 Volt  
277V=277 Volt  
UNV=Universal  
Voltage 120-277  
ST=Semi-SpecularTannenbaum  
Main Reflector  
LSC=Lamp Shield Cable  
Leave Blank=Center mounted  
Lamps (standard)  
Wattage (Length)  
14T5=14WT5 (24")(1)  
NOTES:  
(1)  
Options  
24T5=24WT5HO (24")(1)  
2' x 2' and 2' x 4' Center Lamp Shield models only.  
(2) Products also available in non-US voltages and  
frequencies for international markets.  
GL=Single Element Fuse  
GM=Double Element Fuse  
Lamps=Lamps installed  
Flex=Flex installed  
ACCESSORIES  
EQ = T-BAR Safety Earthquake Clips  
(Use Four Per Fixture)  
DF-22-W = Drywall Frame Kit  
SHIPPING INFORMATION  
Catalog No.  
Wt.  
2RDI-114T5RPD  
2RDI-214T5RPD  
2RDI-314T5RPD  
17 lbs.  
17 lbs.  
17 lbs.  
Specifications and Dimensions subject to change without notice.  
Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801  
ADF032747  
08/02/2008 3:16:54 PM  
 

Conair Electric Shaver LWD1P User Manual
Conair Hair Clippers HC221 User Manual
Cornelius Ice Maker Series 200 User Manual
Craftsman Trimmer 31679614 User Manual
Delta Electronics Power Supply S48SP User Manual
EverFocus Security Camera EFD300 User Manual
Everpure Water System CWS 10 User Manual
Frigidaire Washer Dryer FWS545RF User Manual
GE Air Cleaner 169018 User Manual
Genicom Printer cL160 User Manual