OPE R ATING MANUAL
OPERATING MANUAL
AIR CONDITIONER
CAS S ETTE TYPE
Indoor Unit
AUU18RC
AUU24RC
AUU36RC
AUU42RC
Outdoor Unit
AOU18RC
AOU24RC
AOU36RC
AOU42RC
KEEP THIS OPERATION MANUAL
FOR FUTURE REFERENCE.
P/N9368987022
FUJ ITS U GE NE R AL LIMITE D
NAME OF PARTS
Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).
Fig. 1
Fig. 2
Electrical Breaker
Fig. 3
1
2
3
This breaker is installed during
the electrical installation.
M
Fig. 4
I
J
K
N
O
P
Q
R
AM
CLOCK
NON STOP
AUTO
°F
AMPM CLOCK
NON STOP
OFFON
TIMER
WEEKLY
AUTO
AUTO
TIMER
MODE
SET TIME
TEMP./DAY
FAN
CONTROL
OFF
ON
L
H
COOL
°F
MASTER
CONTROL
AMPM TIMER
NEXT DAY
DAY
DAY OFF
DEFROST TEST
FAN
HEAT
ON
OFF
CLOCK ADJUST
G
1
2
ZONE
SET
ENERGY SAVE
DAY OFF
START/STOP
S T
Fig. 5 Display
F
D
B 8 6
0
C A 9 7
● For explanatory purposes, the figure showing the remote
controller display shows all possible displays. The actual
display shows only that area that is being adjusted or used.
E
Fig. 4 Remote Controller
Fig. 1 Indoor Unit
1 Air Filter
6 START/STOP Button
7 Operation Lamp
K FAN CONTROL Button
2 Air Intake Grille
L MASTER CONTROL Button
3 Air Flow Direction
8 ENERGY SAVE Button
9 DAY OFF Button
M Remote Controller Display
Flaps
(Fig. 5)
0 ENERGY SAVE Lamp
A ZONE Control Button
B SET Button
N Timer Mode Display
Fig. 2 Outdoor Unit
O Clock Display (CLOCK/TIMER)
P Set Temperature Display
4 Air intake
5 Air outlet
C ZONE Control Lamp
(TEMP.)
D AIR FLOW DIRECTION SWING
Q Fan Speed Display
R Operation Mode Display
S DEFROST Display
T TEST Display
Button
E AIR FLOW DIRECTION SWING
Lamp
F AIR FLOW DIRECTION SET Button
G CLOCK ADJUST Button
H TIMER MODE Button
I SET TIME Button
J TEMP./DAY Button
En-2
PREPARATION
Set the Current Time and Day
Press the CLOCK ADJUST button for more than three
seconds.
AM
CLOCK
1
DAY
Press the TEMP./DAY button and set the day.
TIMER
MODE
SET TIME
TEMP./DAY
FAN
CONTROL
2
MASTER
▲: Use to advance the day forward.
CONTROL
▼: Use to turn the day back.
The day is indicated by a code number from 1 to 7, as shown in the table
below. Set to the number that corresponds to the current day.
CLOCK ADJT
NE
AVE
START/STOP
F
2
3
1
DAY CODE
1
2
3
4
5
6
7
DAY OF THE WEEK MON TUE WED THU
FRI
SAT SUN
Press the SET TIME button and set the time.
▲: Use to advance the time forward.
▼: Use to turn the time back.
(Press once to move the time 1 minute; hold down and the time will move
10 minutes at a time.)
3
4
Press the CLOCK ADJUST button again.
This registers the new day and time values. The day display goes off, and
the time display stops flashing.
AM
CLOCK
Example: Set the time to 9:31.
OPERATION
Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).
To Select Mode Operation
AM
CLOCK
NON STOP
AUTO
°F
Press the START/STOP button.
The unit will start and the remote controller’s operation lamp (green) will
light up.
1
2
TIMER
MODE
SET TIME
TEMP./DAY
FAN
CONTROL
MASTER
CONTRO
Press the MASTER CONTROL button to select the de-
sired mode.
CLOCK ADJUST
2
ZONE
SET
ENERGY SAVE
DAY OFF
START/STOP
s
AUTO
s
*HEAT
t
t
FAN
COOL
1
Example: When set to AUTO
To Set the Thermostat
Press the TEMP./DAY button to the desired temperature.
▲ : Press to raise the thermostat setting.
AM
CLOCK
NON STOP
AUTO
°F
▼ : Press to lower the thermostat setting.
TIMER
MODE
SET TIME
TEMP./DAY
FAN
CONTROL
●Thermostat setting range:
MASTER
CONTROL
AUTO ......................................64 to 88 °F
* Heating ...................................60 to 88 °F
CLOCK ADJUST
Cooling/Dry ............................64 to 88 °F
The thermostat cannot be used to set room temperature during the FAN mode
(the temperature will not appear on the remote controller’s display).
ZONE
SET
DAOFF
START/STOP
Example: When set to 84 °F
The thermostat setting should be considered a standard value, and may
differ somewhat from the actual room temperature.
En-3
OPERATION
Instructions relating to heating(*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).
To Set the Fan Speed
Press the FAN CONTROL button to select the fan speed.
AM
CLOCK
NON STOP
AUTO
°F
sAUTO
sHIGH
sMED
sLOW
TIMER
MODE
SET TIME
TEMP./DAY
FAN
CONTROL
When set to AUTO:
MASTER
CONTROL
* Heating : Fan operates so as to optimally circulate warmed air.
However, the fan will operate at very low speed when the tem-
perature of the air issued from the indoor unit is low.
Cooling : As the room temperature approaches that of the thermostat set-
ting, the fan speed becomes slower.
CLOCK ADJUST
ZONE
SET
ENERGY SAV
DAY OFF
TOP
Fan
: The fan alternately turns on and off; when on, the fan runs at the
Example: When set to HIGH
low fan speed.
The fan will operate at a very low setting during Monitor operation.
: HIGH
: MED
: LOW
To Stop Operation
Press the START/STOP button.
The remote controller’s operation lamp (green) will go out.
The display contents disappear and only the current time is displayed.
About Mode Operation
AUTO:
COOLING MODEL
Cooling Operation
Dry Operation
● When the room temperature is 4 °F higher than the set temperature, the mode
will switch between Cooling and Drying.
Thermostat control
● During the Drying mode operation, the FAN setting should be switched to LOW
for a gently cooling effect during which the fan may temporarily stop rotating.
● If the mode automatically selected by the unit is not satisfactory, see page 3 for
4 °F
instructions on changing the mode setting (COOL, FAN).
Setting temperature
AUTO (* AUTO CHANGEOVER):
HEAT & COOL MODEL (Reverse cycle)
● When AUTO CHANGEOVER is selected, the air conditioner selects the appropriate operation mode (Cooling or Heating)
according to your room’s present temperature.
● When AUTO CHANGEOVER is first selected, the fan will operate at very low speed for about one minute while the unit
determines the current conditions of the room and accordingly selects the proper operation mode.
● When the air conditioner has adjusted your room’s temperature to near the thermostat setting, it will begin monitor opera-
tion. In the monitor operation mode, the fan will operate at low speed. If the room temperature subsequently changes, the
air conditioner will once again select the appropriate operation (Heating, Cooling) to adjust the temperature to the value set
in the thermostat. (The monitor operation range is 4 °F relative to the thermostat setting.)
● If the mode automatically selected by the unit is not satisfactory, see page 3 for instructions on changing the mode setting
(HEAT, COOL, FAN).
* Heating:
● Use to warm your room.
● When Heating mode is selected, the air conditioner will operate at very low fan
* During Heating mode:
Set the thermostat to a temperature set-
ting that is higher than the current room
speed for about 3 to 5 minutes, after which it will switch to the selected fan set-
temperature. The Heating mode will not
ting. This period of time is provided to allow the indoor unit to warm up before
operate if the thermostat is set lower than
begin full operation.
the actual room temperature.
● When the room temperature is very low, frost may form on the outside unit, and
During Cooling mode:
Set the thermostat to a temperature set-
ting that is lower than the current room
temperature. The Cooling mode will not
operate if the thermostat is set higher than
the actual room temperature (in Cooling
mode, the fan alone will operate).
its performance may be reduced. In order to remove such frost, the unit will
automatically enter the defrost cycle from time to time. During defrosting (see
page 15), the heating mode will be temporarily interrupted. DEFROST will be
shown on the remote controller display.
Cooling:
● Use to cool your room.
Fan:
● Use to circulate the air throughout your room.
En-4
TIMER OPERATION (OFF TIMER/ON TIMER)
Before using the timer function, be sure that the remote controller is set to the correct current time and Day.
Press the START/STOP button; after the unit starts operation perform the following procedure:
OFF Timer / ON Timer
Press the TIMER MODE button and display either OFF
Timer or ON Timer.
The timer will start operating. (If you set the ON timer, the air conditioner
will stop operating).
AM
AM
CLOCK
TIMER
1
COOL
OFF
°F
TIMER
OFF
TIMER
MODE
SET TIME
TEMP./DAY
FAN
CONTROL
MASTER
CONTROL
Each time the button is pressed the timer function changes in the follow-
ing order:
CLOCK ADJ
ENERGY SAVE
DAY OFF
START/STOP
1
2
s
s
NON STOP (RESET)
OFF
sON
s WEEKLY
Press the SET TIME button and set the timer time.
▲ : Use to advance the time forward.
▼ : Use to turn the time back.
(Press once to move the time 1 minute; hold down and the time will move
10 minutes at a time.)
AM
CLOCK
2
COOL
OFF
°F
TIMER
PM TIMER
OFF
Example: Setting the OFF TIMER
to 11:35 p.m.
To Cancel theTimer Mode
During Timer Operation
To confirm or Change Settings
Before Starting Operation
To Change the Timer Setting
During Operation
Press the TIMER MODE button and set
the display to “NON STOP” (the unit will
switch to non-stop operation).
Operate as noted in step 2.
● To confirm settings
Press the TIMER MODE button once.
(The timer setting information will be
displayed for 15 seconds after the
TIMER MODE button is pressed.)
● To change settings
To Stop Operation During
Use of Timer Mode
To Change the Timer Mode
During Operation
Confirm the settings as noted above,
then press the SET TIME button and
TIMER MODE button as necessary to
change the desired timer setting.
(The timer settings will be displayed
for 15 seconds after the button is
pressed.)
Press the START/STOP button.
Press the TIMER MODE button and set
the unit to the desired mode.
● After confirming or changing the set-
tings, press the START/STOP button
to start operation.
En-5
TIMER OPERATION (WEEKLY TIMER)
Use the weekly timer to set operating times for each day of the week.
Weekly Timer Features
● Set different operating times for each day of the week.
● Set one or two operating spans (one or two ON times and one or two OFF times) per day.
● Set time to a resolution of 5 minutes.
● OFF time can be carried over to the subsequent day.
● Use the “DAY OFF” setting to cancel operation for any day of the coming week (one-time cancellation).
Setting Up the Weekly Timer Operation
Press the START/STOP button to stop the air conditioner, and then proceed as fol-
lows.
Press the TIMER MODE button so that “WEEKLY” ap-
1
COOL
ON
pears on the display.
The display now shows the current day (by DAY CODE), the first ON and
OFF times for the day (the “WEEKLY 1” times), the fan speed, and the
operating mode.
The top time value gives the ON time, and the bottom value gives the
OFF time.
TIMER
DAY
WEEKLY
1
OFF
TIMER
MODE
SET TIME
TEMP./DAY
FAN
CONTROL
MASTER
CONTROL
CLOCK ADJUS
If either time is not set, the corresponding time display is blank “
”.
ZONE
SET
START/STOP
1
2
DAF
Press the TEMP./DAY button to select the day that you
2
want to set up.
▲ : Use to advance the day forward.
▼ : Use to turn the day back.
3
DAY CODE
1
2
3
4
5
6
7
DAY OF THE WEEK MON TUE WED THU
FRI
SAT SUN
Hold the SET button down for 3 seconds.
3
4
The “WEEKLY 1” ON time starts flashing, and the fan speed and operat-
ing mode displays go off.
Press the SET TIME button to set the day’s first ON
time.
▲ : Use to advance the time forward.
▼ : Use to turn the time back.
AM
ON
TIMER
DAY
WEEKLY
1
OFF
TIMER
MODE
SET TIME
TEMP./DAY
FAN
CONTROL
(Press once to move the time 5 minute; hold down and the time will move
10 minutes at a time.)
MASTER
CONTROL
CLOCK ADJUST
4
Press the SET button.
This registers the first ON time setting for the selected day.
The ON time display stops flashing, and the “WEEKLY 1” OFF time starts
flashing.
ZON
ENERGY SAVE
DAY OFF
START/STOP
5
SET
5
En-6
TIMER OPERATION (WEEKLY TIMER)
Press the SET TIME button to set the day’s first OFF
AM
6
ON
time.
PM TIMER
DAY
WEEKLY
1
OFF
The earliest OFF time you can set is 5 minutes after the ON time. The
latest OFF time is 11:55 p.m. on the subsequent day.
TIMER
MODE
SET TIME
TEMP./DAY
FAN
CONTROL
MASTER
CONTROL
Press the SET button.
CLOCK ADJUST
7
This registers the first OFF time for the day, completing the “WEEKLY 1”
6
settings for that day.
The display switches to “WEEKLY 2”, and the day’s second ON time be-
gins flashing.
ZON
ENERGY SAVE
DAY OFF
START/STOP
SET
7
Repeat the operations described in Steps 4 to 7 to set
the second ON and OFF times for the day (the “WEEKLY
2” times).
When you press the SET button after setting the “WEEKLY 2” OFF time,
the system registers the “WEEKLY 2” settings for the day and returns you
to the “WEEKLY 1” ON time setup process. (The first ON setting reap-
pears and begins flashing.)
8
If the timer is not set, press the SET but-
ton with the time display blank “
and perform next operation.
”,
You can review your settings by pressing the SET button. Each press
moves you to the next setting, as follows.
s
s
s
WEEKLY 1
ON
WEEKLY 1
OFF
WEEKLY 2
ON
s WEEKLY 2
OFF
Press the TEMP./DAY button to select another day for
setup. The repeat steps 4 to 8 above to set the ON and
OFF times for that day.
9
When you have finished setting all of the times, hold
10down the SET button for 3 seconds.
AM
CLOCK
The WEEKLY display flashes for 3 seconds while the new WEEKLY TIMER
settings are registered, and then the clock display reappears.
MODE
CONTROL
NOTES:
(1) If no time values are flashing, the clock display will automatically reappear after 15 seconds if no buttons are pressed.
(2) A flashing time value indicates that the system is in time-setting mode. To return to the clock display you must hold
down the SET button for 3 seconds.
(3) You do not need to set values for both WEEKLY 1 and WEEKLY 2. If you wish, you can set values only for WEEKLY 1
or only for WEEKLY 2.
(4) The allowable range for the day’s time settings is shown below.
Cannot set
5 min.
OFF
Available range
5 min.
ON
Cannot set
ON
OFF
Next day’s WEEKLY
settings
Previous day’s WEEKLY
settings
12:00 a.m.
12:00 a.m.
(5) If you set the OFF time to occur on the day following the ON time, the NEXT DAY caption appears on the display.
PM
ON
PM TIMER
DAY
WEEKLY
OFF
2
NEXT DAY
En-7
Starting Weekly Timer Operation
Press the TIMER MODE button so that “WEEKLY” ap-
pears on the display.
AM
CLOCK
COOL
1
°F
PM TIMER
WEEKLY
1
OFF
Press the START/STOP button to start operation.
TIMER
MODE
SET TIME
TEMP./DAY
FAN
CONTROL
2
(This step is not necessary if the air conditioner is already running.)
MASTER
CONTROL
CLOCK ADJUS
Weekly timer operation starts, and the operation lamp comes on.
(If the current time is between the first or second ON and OFF time set-
tings for the current day, the air conditioner will start. Otherwise the air
conditioner will remain off.)
ZONE
SET
ENERGY SAVE
DAY OFF
START/STOP
1
2
The day display is replaced by the temperature display.
The upper time display now shows the current time, and the lower time
display shows the next scheduled ON or OFF time.
To Stop Weekly Timer Operation
Reviewing the Time Settings
● To stop weekly timer while leaving the air conditioner run-
Press the START/STOP button to stop the air conditioner, and
then proceed as follows.
ning:
Press the TIMER MODE button to select NONSTOP, OFF
TIMER, or ON TIMER.
1 Press the TIMER MODE button so that “WEEKLY” appears
on the display.
● To stop weekly timer operation and the air conditioner also:
2 Press the TEMP./DAY button to select the day that you want
to check.
Press the START/STOP button.
3 Press the SET TIME button (▲ or ▼) to switch between the
“WEEKLY 1” or “WEEKLY 2” time displays.
Cancelling Selected Time Settings
Press the START/STOP button to stop the air conditioner, and then proceed as fol-
lows.
Carry out steps 1 to 3 of the “Setting Up the Weekly
Timer Operation” procedure to select the day you want
to edit.
1
ON
PM TIMER
DAY
WEEKLY
1
OFF
TIMER
MODE
SET TIME
TEMP./DAY
FAN
CONTROL
MASTER
CONTROL
Press the SET button to select the ON time that you
want to cancel.
2
CLOCK ADJUST
ZONE
SET
ENERGY SAVE
DAY OFF
START/STOP
Be sure to select an ON time (the upper time display).
3
Hold down the ▼ side of the SET TIME button until the
3
2
time display becomes blank “
”.
Example: Clearing the “WEEKLY 1” ON/
OFF times for day 4 (Thurs-
day)
Press the SET button.
The first OFF time setting (“WEEKLY 1” OFF time) is deleted and replaced
by a flashing blank pattern “ ”.
4
5
6
ON
TIMER
DAY
WEEKLY
1
Press the SET button again.
This completes deletion of the “WEEKLY 1” ON/OFF settings.
The second ON time setting (“WEEKLY 2” ON time) appears and flashes.
If you wish to delete other time settings, repeat steps 2 through 5.
OFF
PM
ON
PM TIMER
DAY
WEEKLY
Once the setting has been canceled, hold down the
SET button for 3 seconds.
The WEEKLY display flashes briefly, and then the clock display appears.
OFF
2
En-8
TIMER OPERATION (WEEKLY TIMER)
To Change Selected Time Settings
Press the START/STOP button to stop the air conditioner, and then proceed as fol-
lows.
Carry out steps 1 to 3 of the “Setting Up the Weekly
Timer Operation” procedure to select the day you want
to edit.
PM
1
ON
PM TIMER
DAY
WEEKLY
OFF
2
TIMER
MODE
SET TIME
TEMP./DAY
FAN
CONTROL
MASTER
CONTROL
Press the SET button to select the time that you want
2
CLOCK ADJUST
to change.
The selected setting flashes on the display. Each press moves you to the
next setting for the selected day, as follows.
ZONE
SET
ENERGY SAVE
DAY OFF
START/STOP
s
s
s
s
WEEKLY 1
ON
WEEKLY 1
OFF
WEEKLY 2
ON
WEEKLY 2
OFF
2
Example: Changing the “WEEKLY 2”
ON setting for day 5 (Friday)
from 2:00p.m. to 3:30p.m.
Press the SET TIME button to change the time setting.
PM
AUTO
AUTO
3
4
5
ON
PM TIMER
DAY
WEEKLY
Press the SET button.
The new setting overwrites the previous setting.
OFF
DEFROST TEST
1
2
TIMER
MODE
SET TIME
TEMP./DAY
FAN
CONTROL
MASTER
CONTROL
Once the setting has been canceled, hold down the SET
button for 3 seconds.
The WEEKLY display flashes briefly, and then the clock display appears.
CLOCK ADJUST
ZONE
SET
ENERGY SAVE
DAY OFF
START/STOP
3
4
NOTES:
In the following cases, cancel the set time prior to making the required amendments.
(1) If you want to change the ON time to a time that is later than the currently set OFF time.
ON OFF
WEEKLY 1
Time
ON
OFF
Change
WEEKLY 1
Time
(2) If the change would cause a temporary overlap between the first and second ON/OFF time spans.
ON OFF ON OFF
WEEKLY 2
WEEKLY 1
Time
Time
Temporary overlap
ON
ON
Change
OFF
OFF
WEEKLY 1
WEEKLY 2
En-9
About the DAY OFF
● Use the DAY OFF setting to switch off timed operation for a selected day in the coming week.
● This is a temporary, one-time setting. The DAY OFF setting is automatically cleared as soon as the specified day passes.
Using the DAY OFF Setting
Press the START/STOP button to stop the air conditioner, and then proceed as fol-
lows.
COOL
ON
PM
PM TIMER
DAY
WEEKLY
1
DAY OFF
OFF
Carry out steps 1 to 2 of the “Setting Up the Weekly
Timer Operation” procedure to select the day that you
want to set as the DAY OFF.
1
2
TIMER
MODE
SET TIME
TEMP./DAY
FAN
CONTROL
MASTER
CONTROL
CLOCK ADJUST
ZONE
SET
ENERGY SAVE
DAY OFF
START/STOP
Press the DAY OFF button.
The DAY OFF setting is registered, and the DAY OFF caption appears on
the display.
2
● To cancel the DAY OFF setting:
You can cancel the setting by pressing the DAY OFF button again.
Example: To switch off timed operation
for day 2 (Tuesday)
NOTES:
(1) The DAY OFF setting is only available for days for which weekly time settings already exist.
(2) You can make this setting for any of the next seven days (counting from the current day).
(3) The DAY OFF setting is effective over the range illustrated below. The Weekly setting for which an ON time has been
set is eligible for the day in which the DAY OFF has been set.
Effective range of DAY OFF setting
ON
OFF
ON
OFF
WEEKLY setting for preceding
day
WEEKLY setting
Preceding day
DAY OFF day
Next day
12:00 a.m.
12:00 a.m.
(4) The display on the clock’s lower line will usually be “
” for the DAY OFF set day during Weekly operations.
AM
CLOCK
TIMER
COOL
°F
WEEKLY
DAY OFF
Precautions during setup
Setup is not possible in the following cases, so amend the time.
● If you set an ON time while leaving the OFF time setting blank:
Nothing will happen when you press the SET button.
To proceed, press the SET TIME button and enter an appropriate setting.
● When an attempt is made to set only the OFF time.
Nothing will happen when you press the SET TIME button.
Press the SET button and amend the entry for the ON time.
● ON and OFF times cannot be set to the same value.
● The OFF time cannot be set earlier than the ON time.
● The WEEKLY 2 settings cannot be set earlier than the WEEKLY 1 settings.
● The WEEKLY 1 and WEEKLY 2 time spans cannot overlap.
En-10
ENERGY SAVE OPERATION
Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).
To Use the ENERGY SAVE
Press the ENERGY SAVE button.
The unit will run in the ENERGY SAVE mode.
AM
CLOCK
NON STOP
AUTO
°F
The ENERGY SAVE lamp (green) will light.
TIMER
MODE
SET TIME
TEMP./DAY
FAN
CONTROL
MASTER
CONTROL
To Stop the ENERGY SAVE
CLOCK ADJUST
ZONE
SET
ENERGY SAVE
DAY OF
START/STOP
Press the ENERGY SAVE button one more time.
The ENERGY SAVE mode will be turned off.
The ENERGY SAVE lamp goes off, and the unit will return to the former operat-
ing conditions.
About the ENERGY SAVE
● The energy conservation mode (ENERGY SAVE) raises the set temperature slightly in the cooling mode and lowers the set
temperature in the heating mode, using a computer program to economically control the operation of the unit.
● If you press the ENERGY SAVE button while the air conditioner is on, it will change to the conservation mode. If you press
the ENERGY SAVE button while the unit is in the timer mode (ON timer, WEEKLY timer), the unit will go into the conserva-
tion mode when the unit starts with the timer.
● If you turn off the air conditioner while in the conservation mode, the mode will be shut off.
● The temperature set on the remote controller will not change if the energy save mode is used.
■ * When Heating
■ When Cooling
After the ENERGY SAVE button is pressed, the set tempera-
ture will be lowered about 2 °F every 30 minutes. When it
has lowered a total of 4 °F, then it will hold that temperature.
After the ENERGY SAVE button is pressed, the set tempera-
ture will be raised about 1 °F every 30 minutes. When it has
gone up a total of 2 °F, then it will hold that temperature.
2 °F
4 °F
▼ Set to the ENERGY SAVE mode.
30 min.
30 min.
2 °F
1 °F
▲ Set to the ENERGY SAVE mode.
En-11
ADJUSTING THE DIRECTION OF AIR CIRCULATION
Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).
Begin air conditioner operation before performing this procedure.
Vertical Air Flow Direction Adjustment
DEFROST TEST
Press the AIR FLOW DIRECTION SET button.
Each time the button is pressed, the air flow direction range will change as fol-
lows:
TIMER
MODE
SET TIME
TEMP./DAY
FAN
CONTROL
MASTER
CONTROL
CLOCK ADJUST
Fig. 6
ZONE
SET
ENERGY SAVE
DAY OFF
START/STOP
1
2
3
4
1
2
3
4
● Always use the remote controller’s AIR
FLOW DIRECTION SET button to ad-
just the UP/DOWN air flow direction
flaps. Attempting to move them manu-
ally could result in improper operation;
in this case, stop operation and restart.
The flaps should begin to operate
properly again.
The remote controller’s display does not change.
● Use the air flow direction adjustments within the ranges shown above.
● The air flow direction is set automatically as shown, in accordance with the
type of operation selected.
During Cooling mode
: Horizontal flow 1
: Downward flow 4
* During Heating mode
● When used in a room with infants, chil-
dren, elderly or sick persons, the air
flow direction and room temperature
should be considered carefully when
making settings.
● During AUTO mode operation, for the first minute after beginning operation,
air flow will be horizontal 1; the air flow direction cannot be adjusted during
this period.
SWING OPERATION
Begin air conditioner operation before performing this procedure.
To Select SWING Operation
1
2
Press the AIR FLOW DIRECTION SWING button.
The AIR FLOW DIRECTION SWING lamp (orange) will light.
In this mode, the UP/DOWN air flow direction flaps will swing automatically to
direct the air flow both up and down.
TIMER
MODE
SET TIME
TEMP./DAY
FAN
CONTROL
MASTER
CONTROL
CLOCK ADJUST
ZONE
SET
ENERGY SAVE
DAY OFF
START/STOP
To Stop SWING Operation
Press the AIR FLOW DIRECTION SWING button once again.
The AIR FLOW DIRECTION SWING lamp will go out.
Air flow direction will return to the setting before swing was begun.
About Swing Operation
● The range of swing is relative to the currently set air flow
● If the swing range is not as desired, use the remote con-
troller’s AIR FLOW DIRECTION SET button to change the
range of swing.
direction.
Air flow direction set
Range of swing
1 to 3
● The SWING operation may stop temporarily when the air
conditioner’s fan is not operating, or when operating at
very low speeds.
1
2, 3
4
2 to 4
1 to 4 (All range)
Air flow direction range (see Fig. 6)
En-12
CLEANING AND CARE
● Before cleaning the unit, be sure to stop the unit and disconnect the power supply.
CAUTION!
● Turn off the electrical breaker.
● A fan operates at high speed inside the unit, and personal injury could result.
Cleaning the Air Filter
● When reinstalling the filter, be sure that the hooks at A
1. Push the intake grille pushbuttons (two
places).
and B engage correctly into place.
B
2. Open the intake grille.
4. Clean the air filters.
Remove the dust from the air filters by vacuuming or
washing them. After washing, allow the air filters to dry
thoroughly in an area protected from sunlight.
OPEN
PUSH
3. Hold down the hook at A and pull the fil-
ter out.
● Dust can be cleaned from the air filter either with a vacuum
cleaner, or by washing the filter in a solution of mild de-
tergent and warm water. If you wash the filter, be sure to
allow it to dry thoroughly in a shady place before rein-
stalling.
● If dirt is allowed to accumulate on the air filter, air flow
will be reduced, lowering operating efficiency and increas-
ing noise.
● During periods of normal use, the air filters should be
A
cleaned every two months.
Filter
B
A
Intake grille
● When used for extended periods, the unit may accumulate dirt inside, reducing its performance. We recommend that the
unit be inspected regularly, in addition to your own cleaning and care. For more information, consult authorized service
personnel.
● When cleaning the unit’s body, do not use water hotter than 100 °F, harsh abrasive cleansers, or volatile agents like
benzene or thinner.
● Do not expose the unit body to liquid insecticides or hairsprays.
● If the unit will not be operated for a period of one month or more, be sure to allow the inner parts of the unit to dry
thoroughly, in advance, by operating the unit in fan mode for half a day.
En-13
ERRORS AND SELF DIAGNOSIS
Error Code
Error Code
Error contents
Communication error
t
s
(indoor unit
remote controller)
Communication error
t
s
(indoor unit
outdoor unit)
TIMER
MODE
SET TIME
TEMP./DAY
FAN
CONTROL
Room temperature sensor open
MASTER
CONTROL
CLOCK ADJUST
Room temperature sensor shortcircuited
ONE
ENERGY SAVE
DAY OFF
START/STOP
Indoor heat exchanger temperature
sensor open
Indoor heat exchanger temperature
sensor shortcircuited
If there is a problem with the air conditioner, it will stop run-
ning and “E: EE” will be displayed instead of the clock.
Outdoor heat exchanger temperature
sensor open
Outdoor heat exchanger temperature
sensor shortcircuited
(1) If the operation lamp is on then press the START/
STOP button to turn it off.
(2) Press the SET TIME (▼) and the TEMP./DAY (▼)
buttons at the same time for more than three seconds
to start the self diagnosis check.
An error code will be displayed in the clock display area.
(3) Press the SET TIME (▼) and the TEMP./DAY (▼) buttons
again for more than three seconds to end the self diag-
nosis check.
Power source connection error
Float switch operated
Outdoor temperature sensor open
Outdoor temperature sensor
shortcircuited
Discharge pipe temperature sensor open
Discharge pipe temperature sensor
shortcircuited
Outdoor high pressure abnormal
Discharge pipe temperature abnormal
Model abnormal
Indoor fan abnormal
Outdoor signal abnormal
Outdoor EEPROM abnormal
En-14
OPERATION DETAILS
Instructions relating to heating(*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).
Please read and understand the following details regarding this air conditioner.
Operation and Performance
* Heating Performance
*
Microcomputer-controlled Automatic Defrosting
● This air conditioner uses a heat pump which absorbs heat
from outside air and brings it indoors. As a result, its heat-
ing performance is reduced as the temperature of out-
side air drops. If you find that insufficient room heat is
produced, we recommend that you use the air conditioner
together with other heating appliances.
When the outside temperature is low and the humidity high,
frost will collect on the outside unit, reducing heater effi-
ciency. When this happens, the computer will automatically
start the defrost cycle. During the defrost cycle, the indoor
fan will shutdown and DEFROST will be displayed on the
remote controller. It will take anywhere from 4 to 15 min-
utes before the air conditioner starts up again.
● Heat-pump type air conditioners use warm-air
recirculation to warm your entire room. As a result, some
time will be required after starting operation until your
entire room becomes warm.
Low Ambient Cooling
When the outdoor temperature drops, the outdoor unit’s fans
may switch to Low Speed, or one of the fans may stop inter-
mittently.
*
When Indoor and Outdoor Temperatures are High
When both indoor and outdoor temperatures are high dur-
ing use of the heating mode, the outdoor unit’s fan may stop
at times.
AUTO Restart
In Event of Power Interruption
● Should the power supply to the air conditioner be inter-
rupted by a power failure, the air conditioner will restart
automatically in the previously selected mode once the
power is restored.
● Use of other electrical appliances (electric shaver, etc.) or
nearby use of a wireless radio transmitter may cause the
air conditioner to malfunction. In this event, temporarily
turn off the circuit breaker turn it on again and then use
the remote controller to resume operation.
Temperature and Humidity Range
*Heating Mode
Cooling/Dry Mode
Outdoor temperature
COOLING MODEL
About 32 to 115 °F
—
AUU18RC
HEAT &
About 32 to 75 °F
AUU24RC
COOL MODEL
About 32 to 115 °F
About 65 to 90 °F
AUU36RC
AUU42RC
(Reverse Cycle)
About 17 to 75 °F
About 86 °F or less
Indoor temperature
Indoor humidity
About 80 % or less
If the unit is used for long pe-
riods under high-humidity
conditions, condensation
may form on the surface of
the indoor unit, and drip onto
the floor or other objects un-
derneath.
—
● If the air conditioner is used under higher temperature conditioner than those listed, the built-in protection circuit may
operate to prevent internal circuit damage. Also, during Cooling and Dry modes, if the unit is used under conditions of
lower temperature than those listed above, the heat-exchanger may freeze, leading to water leakage and other damage.
● Do not use this unit for any purposes other than the Cooling, (*)Heating, Dehumidifying, and air-circulation of rooms in
ordinary dwellings.
En-15
SYSTEM OPERATION
<Control Several Units with just one Remote Controller>
One remote controller can control up to 16 air conditioners.
All the air conditioners can be operated with the same set-
ting.
Outdoor
unit
Indoor unit
Remote
controller
Unit No.1
Unit No.2
Unit No.16
To Use the ZONE CONTROL
When the ZONE control button is pressed while multiple air conditioners
are being centralized controlled, only the preset air conditioners stop.
AM
CLOCK
NON STOP
AUTO
°F
Press the ZONE control button.
Preset units will stop.
TIMER
MODE
SET TIME
TEMP./DAY
FAN
CONTROL
MASTER
CONTROL
The ZONE lamp (green) will light.
CLOCK ADJUST
ZONE
SET
ENERGY SAVE
DAY OFF
START/STOP
To Stop the ZONE CONTROL
Press the ZONE control button one more time.
Those units that were stopped will start again.
The ZONE lamp will go out.
En-16
TROUBLESHOOTING
Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).
In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the elec-
trical breaker, and consult authorized service personnel.
Merely turning off the unit’s power switch will not completely disconnect the unit from the power
source. Always be sure to turn off the electrical breaker to ensure that power is completely off.
WARNING!
Before requesting service, perform the following checks:
Symptom
See Page
Problem
NORMAL
FUNCTION
Doesn’t operate immedi-
ately:
● If the unit is stopped and then immediately started again, the com-
pressor will not operate for about 3 minutes, in order to prevent
fuse blowouts.
—
● Whenever the electrical breaker is turned off then on again, the
protection circuit will operate for about 3 minutes, preventing unit
operation during that period.
Noise is heard:
● During operation and immediately after stopping the unit, the
sound of water flowing in the air conditioner’s piping may be
heard. Also, noise may be particularly noticeable for about 2 to 3
minutes after starting operation (sound of coolant flowing).
—
● During operation, a slight squeaking sound may be heard. This is
the result of minute expansion and contraction of the panel due
to temperature changes.
*● During Heating operation, a sizzling sound may be heard occa-
sional. This sound is produced by the Automatic Defrosting op-
eration.
15
—
—
Smells:
● Some smell may be emitted from the indoor unit. This smell is
the result of room smells (furniture, tobacco, etc.) which have
been taken into the air conditioner.
Mist or steam are
emitted:
● During Cooling, a thin mist may be seen emitted from the indoor
unit. This results from the sudden Cooling of room air by the air
emitted from the air conditioner, resulting in condensation and
misting.
*● During Heating operation, the outdoor unit’s fan may stop, and
steam may be seen rising from the unit. This is due to Automatic
Defrosting operation.
15
—
Air flow is weak or stops:
*● When Heating operation is started, fan speed is temporarily very
low, to allow internal parts to warm up.
*● During Heating operation, if the room temperature rises above
the thermostat setting, the outdoor unit will stop, and the indoor
unit will operate at very low fan speed. If you wish to warm the
room further, set the thermostat for a higher setting.
*● During Heating operation, the unit will temporarily stop opera-
tion (between 2 and 16 minutes) as the Automatic Defrosting mode
operates. During Automatic Defrosting operation, DEFROST will
be shown on the remote controller display.
15
● The fan may operate at very low speed when the unit is monitor-
4
4
ing the room’s temperature.
● In the monitor AUTO operation, the fan will operate at very low
speed.
Water is produced from
the outdoor unit:
*● During Heating operation, water may be produced from the out-
15
door unit due to Automatic Defrosting operation.
En-17
Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).
Items to check
● Has there been a power failure?
Symptom
See Page
CHECK ONCE Doesn’t operate at all:
MORE
—
● Has a fuse blown out, or a circuit breaker been tripped?
● Is the timer operating?
5
● Is the air filter dirty?
Poor Cooling (or *Heating)
performance:
● Are the air conditioner’s intake grille or outlet port blocked?
● Did you adjust the room temperature settings (thermostat) cor-
rectly?
● Is there a window or door open?
—
● In the case of Cooling operation, is a window allowing bright sun-
light to enter? (Close the curtains.)
● In the case of Cooling operation, are there heating apparatus and
computers inside the room, or are there too many people in the
room?
If the problem persists after performing these checks, or if you notice burning smells, stop operation immediately, turn off the
electrical breaker, and consult with authorized service personnel.
En-18
|