FieldServer Computer Drive FS 8700 39 User Manual

Driver Manual  
(Supplement to the FieldServer Instruction Manual)  
FS-8700-39 EST3 ECP  
APPLICABILITY & EFFECTIVITY  
Effective for all systems manufactured after September 2008  
Driver Version:  
Document Revision:  
1.08  
5
 
FS-8700-39 EST3 Driver Manual  
Page 3 of 21  
1.  
EST3 Description  
The EST3 External Communications Protocol (ECP) driver allows the FieldServer to transfer data to  
and from EST devices over RS-232 or RS-485 (with converter) serial ports using the EST3 ECP  
protocol. In the EST application the FieldServer always emulates a Client.  
The FieldServer makes use of the following ECP Services:  
Read Operations:  
Report Service  
Delta Service  
Write Operations:  
Command Service  
All read points are continually updated using the Report Service; response times are enhanced using  
Delta Service broadcasts by the EST3 panel.  
The information that follows describes how to expand upon the factory defaults provided in the  
configuration files included with the FieldServer.  
2.  
Driver Scope of Supply  
2.1. Supplied By FieldServer Technologies for this Driver  
FIELDSERVER  
TECHNOLOGIES PART #  
DESCRIPTION  
FS-8915-10  
7’ Patch Cable  
FS-8917-03  
FS-8917-10  
RJ45 to DB9M Connector adapter  
DB9F to terminal Adapter  
FS-8700-39  
EST3 ECP Driver Manual  
2.2.  
Provided By the Supplier of 3rd Party Equipment  
Hardware  
2.2.1.  
PART #  
DESCRIPTION  
EST3 Gateway  
VERSION  
2.2.2.  
Required 3rd Party Configuration  
The EST3 panel has to be set into the “Gateway Mode” using the EST3 Configuration tool (3-  
SDU)  
Possible Protocols  
ECP Type II  
Supported  
ECP Type II with Text  
ECP Type III  
Not Supported  
Supported  
Not Supported  
ECP Type III with Text  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com  
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: [email protected]  
 
FS-8700-39 EST3 Driver Manual  
Page 4 of 21  
3.  
Hardware Connections  
EST3 ECP  
TB2  
FS-8915-10  
Model 8051  
Function  
FROM DB9F/M  
EST3 ECP  
TB2  
RX  
TX  
GND  
Pin 2  
Pin 3  
Pin 5  
TX 2  
RX 2  
COM 2  
8917-03  
8917-03  
FS-8915-10  
Connect to one of the RS-232  
Ports on the FieldServer  
8
1
FieldServer  
P1  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com  
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: [email protected]  
 
FS-8700-39 EST3 Driver Manual  
Page 5 of 21  
4.  
Configuring the FieldServer as a EST3 Client  
For a detailed discussion on FieldServer configuration, please refer to the FieldServer Configuration  
Manual. The information that follows describes how to expand upon the factory defaults provided in the  
configuration files included with the FieldServer (See “.csv” sample files provided with the FieldServer).  
This section documents and describes the parameters necessary for configuring the FieldServer to  
communicate with an EST3 Server.  
4.1.  
Data Arrays  
The configuration file tells the FieldServer about its interfaces, and the routing of data required. In  
order to enable the FieldServer for EST3 communications, the driver independent FieldServer buffers  
need to be declared in the “Data Arrays” section, the destination device addresses need to be  
declared in the “Client Side Nodes” section, and the data required from the servers needs to be  
mapped in the “Client Side Map Descriptors” section. Details on how to do this can be found below.  
Note that in the tables, * indicates an optional parameter, with the bold legal value being the default  
Section Title  
Data_Arrays  
Column Title  
Data_Array_Name  
Data_Format  
Function  
Provide name for Data Array  
Provides data format  
Legal Values  
Up to 15 alphanumeric characters  
UINT16  
Data_Array_Length  
Number of Data Objects  
1 - 10000  
Example  
 
// Data Arrays  
Data_Arrays  
Data_Array_Name  
DA_AI_01  
DA_AO_01  
DA_DI_01  
,Data_Format  
,Float  
,Float  
,Bit  
,Bit  
,Data_Array_Length  
,200  
,200  
,200  
,200  
DA_DO_01  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com  
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: [email protected]  
 
FS-8700-39 EST3 Driver Manual  
Page 6 of 21  
4.2.  
Client Side Connection Descriptors  
Section Title  
Connections  
Column Title  
Function  
Specify which port the device is connected to the  
FieldServer  
Legal Values  
P1-P8, R1-R21  
9600, 192002  
Port  
Baud  
Specify baud rate  
Parity*  
Data_Bits*  
Protocol  
Specify parity  
Specify data bits  
Specify protocol to be used by this port  
None  
8
EST3  
Example  
 
// Client Side Connections  
Connections  
Port  
P8  
,Baud  
,19200  
,Parity  
,None  
,Data_Bits  
,8  
,Protocol  
,EST3  
4.3.  
Client Side Node Descriptors  
Section Title  
Nodes  
Column Title  
Function  
Provide name for Node  
Legal Values  
Up to 32 alphanumeric  
characters  
Node_Name  
Node_ID  
Protocol  
MAC ID of FieldServer  
Specify protocol used  
1 – 24 (normally 1)  
EST3  
Specify which port the device is connected to  
the FieldServer  
Port  
P1-P8, R1-R21  
Specify time allowed between poll and  
response  
Timeout  
≥10 seconds  
Example  
 
// Client Side Nodes  
Nodes  
Node_Name  
EST_1  
,Node_ID  
,1  
,Protocol  
,EST3  
,Port  
,P8  
,Timeout  
,10s  
1 Not all ports shown are necessarily supported by the hardware. Consult the appropriate Instruction  
manual for details of the ports available on specific hardware.  
2 Edwards Recommends 19200-baud minimum in order to prevent buffer overruns in the EST3 panel  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com  
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: [email protected]  
 
FS-8700-39 EST3 Driver Manual  
Page 7 of 21  
4.4.  
4.4.1.  
Client Side Map Descriptors  
FieldServer Related Map Descriptor Parameters  
Column Title  
Function  
Legal Values  
Up to 32 alphanumeric  
characters  
Map_Descriptor_Name Name of this Map Descriptor  
Name of Data Array where data  
Data_Array_Name  
One of the Data Array names  
from “Data Array” section above  
0 to maximum specified in “Data  
Array” section above  
is to be stored in the FieldServer  
Data_Array_Offset  
Function  
Starting location in Data Array  
Function of Client Map Descriptor RDBC, WRBC3, WRBX  
4.4.2.  
Driver Related Map Descriptor Parameters  
Column Title  
Function  
Legal Values  
One of the node names  
Node_Name  
Name of Node to fetch data from specified in “Client Node  
Descriptor” above  
EST_Panel  
EST_Card  
Address  
Panel  
Card  
0 - 63  
0 - 255  
0 - 1023  
Starting address of read block  
For Reads: 1 to 34 For Writes:  
1
Length  
Length of Map Descriptor  
Relay, Led, ServGroup,  
GuardPtrl, ChkInGrp,  
AltMessage, Reset, PanelSil,  
AlarmSil, Drill, GAInhibit,  
Reboot, Evacuate, AltSensitiv,  
Partition, CmdList, Input, Zone,  
Card, AndGroup, Matrix,  
TimeCtrl, InstructionText,  
AmpPower, AudMsg, CmdList,  
MCmsg, SetDate, SetTime  
0 - 65535  
EST_Object_Type  
Object type parameter  
EST_Index  
Index parameter  
EST_Route  
Route parameter  
0 - 255  
EST_Priority  
EST_Chan  
Pri parameter  
Chan parameter  
0 - 4 (see note below)  
0 - 255  
EST_Msg_Index  
EST_Account  
MsgIndex parameter  
Account parameter  
0 - 65535  
0 - 255  
EST_ConfCL  
ConfCL parameter  
0 - 65535  
EST_Panel_Mask_1  
EST_Panel_Mask_2  
EST_Panel_Mask_3  
EST_Panel_Mask_4  
EST_Panel_Mask_5  
EST_Panel_Mask_6  
EST_Panel_Mask_7  
EST_Panel_Mask_8  
PanelMask(1) parameter (LSB)  
PanelMask(2) parameter  
PanelMask(3) parameter  
PanelMask(4) parameter  
PanelMask(5) parameter  
PanelMask(6) parameter  
PanelMask(7) parameter  
PanelMask(8) parameter (MSB)  
0 - 255  
0 - 255  
0 - 255  
0 - 255  
0 - 255  
0 - 255  
0 - 255  
0 - 255  
Data_Array_Low_Scale* Scaling zero in Data Array  
-32767 to 32767, 0  
Data_Array_High_Scale* Scaling max in Data Array  
-32767 to 32767, 100  
Node_Low_Scale*  
Node_High_Scale*  
Scaling zero in Connected Node  
Scaling max in Connected Node  
-32767 to 32767, 0  
-32767 to 32767, 100  
3 WRBC is not recommended, as startup values may be invalid  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com  
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: [email protected]  
 
FS-8700-39 EST3 Driver Manual  
Page 8 of 21  
Column Title  
EST_Alarm_DA*  
Function  
Data Array to store Alarm state4  
Data Array to store Trouble  
state4  
Legal Values  
EST_Trouble_DA*  
Data Array to store Supervisory  
EST_Supervisory_DA*  
EST_Monitor_DA*  
state4  
Data Array to store Monitor state4  
Data Array to store state other  
than Alarm, Trouble, Supervisory  
or Monitor4  
Data Array to store the raw value  
of the active bit.  
EST_Others_DA*  
EST_Active_DA  
One of the Data Array Names  
declared in Data Arrays section  
Relay confirmation state. Refer  
to Appendix A.5 for more  
information.  
EST_Relay_Conf_DA  
Data Array to hold Types  
category. Refer to Appendix  
A.5.2  
EST_Types_DA  
Update the default Types list or  
refer to new list. Requires  
'EST_Types_DA' parameter to  
be defined. Refer to Appendix  
A.5.3  
EST_Types_Update  
-, yes, new list  
Acknowledge State. Refer to  
Appendix A.5.4  
Store information from particular  
Report  
One of the Data Array Names  
declared in Data Arrays section  
-, Point I/O Status, Sensitivity,  
Date Time  
DA_Bit_Name  
EST_Report_Type  
4 Refer to Appendix A.4 and Section 4.4.4  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com  
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: [email protected]  
 
 
FS-8700-39 EST3 Driver Manual  
Appendix A. Driver Notes  
Page 10 of 21  
Appendix A.1.  
PanelMasks:  
The 8 PanelMask parameters combine to form a 64-bit field in which each bit denotes an EST panel  
in the network. Commands that use the PanelMasks are executed by each panel for which the  
corresponding bit is set. The Map Descriptor need only define non-zero bytes in the PanelMask.  
Typically this will be EST_Panel_Mask_1 with a value of 1.  
Appendix A.2.  
Setting up Multiple Parameters  
The multiple parameters required by a command must be stored in consecutive locations in the Data  
Array specified by the Map Descriptor, starting at the specified Data_Array_Offset. All parameters  
must be set up before the EST command is executed. This is done using a Block Write (if supported  
by the protocol originating the data) – all parameters are set up in a single write operation, and the  
EST command is triggered with all values in place.  
Appendix A.3.  
Priority:  
The write priority has the possible values of Set, Latch, Low, Medium, and High. These are encoded  
as 00h, 01h, 02h, 03h and 04h respectively.  
Appendix A.4.  
Report and Delta Service:  
The EST ECP3 Report and Delta services report point status slightly differently. The FieldServer  
EST3 driver deals with these differences as follows:  
Report Service (regular polling):  
The full 16-bit point status is stored to the Read Map Descriptor’s Data Array. If optional Data  
Arrays are configured, then the point status is also interpreted according to its Alarm, Trouble,  
Supervisory or Monitor status and the corresponding Data Array is updated. See Appendix A.5  
for detail.  
Delta Service (unsolicited messages):  
Delta Service messages do not provide the same 16-bit status value as supplied by the Report  
Service. For this reason, ONLY the optional Data Arrays will be updated when a Delta message  
is received. Delta messages will therefore only have an effect when optional Data Arrays have  
been configured. See 0 for detail.  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com  
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: [email protected]  
 
 
FS-8700-39 EST3 Driver Manual  
Page 12 of 21  
Appendix A.5.  
Optional Data Arrays  
When optional parameters (EST_Alarm_DA, EST_Trouble_DA, EST_Supervisory_DA, or  
EST_Monitor_DA) are used, the driver automatically separates the Alarm Trouble, Supervisory, and  
Monitor bit from the incoming EST message and places the bit(s) in these Data Arrays at the same  
offset as the incoming message. Other types can be stored in EST_Others_DA Data Array. Only  
one Data type will be reported as active at a particular time; i.e. if Alarm is reported Driver will set  
Alarm bit and reset corresponding bits from Trouble, Supervisory and Monitor Data Arrays. The Driver  
does not correlate Other types with Alarm, Trouble, Supervisory or Monitor types. For different point  
types the active bit has a different meaning. If the user is interested in the meaning, the  
EST_Supervisory_DA Data Array should be configured. If the user is interested in the raw value of  
the Active bit, the data array EST_Active_DA should be configured.  
Appendix A.5.1.  
Relay Confirmation State  
The driver can store the relay confirmation state of a point in a Data Array under the parameter  
EST_Relay_Conf_DA parameter.  
0 - Relay state is not confirmed;  
1 – Relay state confirmed.  
Appendix A.5.2.  
EST_Types_DA  
If it is necessary to override the default Types and Category list (Appendix C.1) the  
EST_Types_DA parameter should be used.  
Example:  
To put HEAT type into the “Monitor” category where all other defaults remain the same, preload  
the data array as follows:  
Preloads  
Data_Array_Name  
DA_Types  
,Preload_Data_Index  
,2  
,Preload_Data_Value  
,4  
,Length  
,1  
Preload_Data_Index is the type of device and Preload_Data_Value holds the category for the  
specified device type. The legal values for Preload_Data_Value are listed below  
Alarm  
1
2
3
4
5
Supervisory  
Trouble  
Monitor  
Others  
Appendix A.5.3.  
EST_Types_Update  
If this parameter is not defined or is “yes”, the driver will update its internal driver list according  
to the parameters preloaded under EST_Types_DA. If the parameter is set to “New List”, the  
driver will use ONLY the parameters defined under EST_Types_DA and will not reference or  
update the default list at all. The driver will therefore not store any data for types that do not  
have preloaded categories.  
Appendix A.5.4.  
DA_Bit_Name  
The ”Acknowledge5” state of a point is stored under this Data Array if configured.  
0 – Acknowledged or Acknowledge not required.  
1 – Point is not Acknowledged yet. To Acknowledge the point change the value to “0”.  
5 The EST3 panel is only able to send/accept Acknowledgement when the panel is in Proprietary Mode.  
Contact EST (Edwards Systems Technology) for information on configuring the panel.  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com  
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: [email protected]  
 
 
FS-8700-39 EST3 Driver Manual  
Page 14 of 21  
Appendix A.6.  
Object Types and Required Parameters  
The tables below list the fields required for the Map Descriptor implementing each object type.  
Object Type  
Relay  
Required Parameters  
Activate and Restore Commands (01h and 11h)  
EST_Panel, EST_Card, Address, EST_Priority  
EST_Panel, EST_Card, Address, EST_Priority  
EST_Index  
Led  
ServGroup  
GuardPtrl  
ChkInGrp  
AltMessage  
AmpPower  
AudMsg  
Reset  
PanelSil  
AlarmSil  
Drill  
GAInhibit  
Reboot  
Evacuate  
AltSensitiv  
MCmsg  
EST_Index, EST_Route  
EST_Index  
EST_Panel_Mask(1..8) Refer to Appendix A.1  
EST_Panel, EST_Card, EST_Priority, EST_Chan  
EST_Panel, EST_Card, EST_Msg_Index, EST_Priority, EST_Chan  
EST_Panel_Mask(1..8) Refer to Appendix A.1  
EST_Panel_Mask(1..8) Refer to Appendix A.1  
EST_Panel_Mask(1..8) Refer to Appendix A.1  
EST_Panel_Mask(1..8) Refer to Appendix A.1  
EST_Panel_Mask(1..8) Refer to Appendix A.1  
EST_Panel_Mask(1..8) Refer to Appendix A.1  
EST_Panel_Mask(1..8) Refer to Appendix A.1  
EST_Panel_Mask(1..8) Refer to Appendix A.1  
EST_Panel, EST_Card, EST_Priority, EST_Account, EST_ConfCL  
EST_Index  
Partition  
Cmd List  
AndGroup  
SetDate  
SetTime  
EST_Index  
EST_Index  
EST_Object_Type. Refer to Appendix A.7  
EST_Object_Type. Refer to Appendix A.7  
Enable and Disable Commands (02h and 12h)  
EST_Panel, EST_Card, Address  
EST_Panel, EST_Card, Address  
EST_Panel, EST_Card, Address  
EST_Index  
Relay  
Led  
Input  
Zone  
Card  
EST_Panel, EST_Card  
ServGroup  
AndGroup  
Matrix  
EST_Index  
EST_Index  
EST_Index  
TimeCtrl  
GuardPtrl  
ChkInGrp  
AmpPower  
Partition  
Instruction Text  
EST_Index  
EST_Index, EST_Route  
EST_Index  
EST_Panel, EST_Card  
EST_Panel, EST_Card, Address  
EST_Panel, EST_Card, Address  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com  
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: [email protected]  
 
FS-8700-39 EST3 Driver Manual  
Page 15 of 21  
Appendix A.7.  
Set Date and Time To Panel  
The following Map Descriptors are required to set the Date and Time of the EST Panel  
// First poke month(1-12) ,day(0-31) and year(yyyy) at offset 1 ,2 and 3 then poke 1 at offset 0 to  
issue SetDate command  
// First poke hour(0-23) ,min(0-59) and sec (0-59) at offset 1 ,2 and 3 then poke 1 at offset 0 to issue  
SetTime command  
Map_Descriptors  
Map_Descriptor_Name ,Data_Array_Name ,Data_Array_Offset ,Function ,Node_Name ,EST_Object_Type ,Length  
MD_Set_Date  
MD_Set_Time  
,DA_Set_Date  
,DA_Set_Time  
,0  
,0  
,Wrbx  
,Wrbx  
,EST_1  
,EST_1  
,SetDate  
,SetTime  
,1  
,1  
The following Map Descriptor will enable the FieldServer to synchronize its clock with the EST panel  
clock  
Map_Descriptors  
Map_Descriptor_Name ,Data_Array_Name ,Data_Array_Offset ,Function ,Node_Name ,EST_Report_Type ,Length  
MD_SLV_TIME  
,DA_TIME  
,0  
,Passive  
,EST_1  
,Date Time  
,6  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com  
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: [email protected]  
 
FS-8700-39 EST3 Driver Manual  
Page 16 of 21  
Appendix B. Troubleshooting Tips  
Appendix B.1.  
Multiple Com Errors  
To solve multiple com errors, try adding an IC_Timeout parameter to the Client Side connections and  
set it to 0.5s.  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com  
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: [email protected]  
 
FS-8700-39 EST3 Driver Manual  
Page 17 of 21  
Appendix C. EST3 Data Format:  
Appendix C.1.  
Input data format  
Each input device is associated with a 16-bit value. The contents of the 16 bits are used to generate  
status types as shown in the table below. Each incoming event is allocated to a status type  
depending on its device type as shown in the table. It is possible to override this default status type  
allocation. Refer to Appendix A.5 for more information.  
Type  
Encode  
Value  
0
Alarm Trouble Supervisory Monitor Others  
Smoke  
Pull  
Heat  
Waterflow  
Stageone  
Zone  
AlarmVerify  
PreAlarm  
Security  
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
1
2
3
4
5
6
7
8
Station  
9
Emergency  
Supervisory  
Valve  
GateValve  
Tamper  
Temperature  
Power  
Signal  
TroubleOpen  
TroubleShort  
LocalTrouble  
MaintAlert  
DirtyHead  
DeviceComm  
GroundFault  
InternalTrouble  
BadType  
BadPersonality  
UnexpectedDevice  
CommonTrouble  
RelayConfirmation  
Monitor  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
LocalMonitor  
Damper  
Fan  
Door  
Switch  
FirePhone  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com  
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: [email protected]  
 
FS-8700-39 EST3 Driver Manual  
Type  
Page 18 of 21  
Encode  
Value  
38  
Alarm Trouble Supervisory Monitor Others  
TestEvent  
Y
DeviceCompatabilityFault  
LogicAnd  
LogicMatrix  
ServiceGroup  
TimeControl  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
50  
64  
65  
66  
67  
68  
69  
70  
71  
72  
73  
74  
75  
127  
128  
129  
130  
131  
132  
133  
134  
135  
136  
137  
138  
139  
140  
141  
142  
143  
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
GuardPatrol  
CheckInGroup  
Internal use only  
Disabled  
Internal use only  
Instruction Text  
Object Running  
Audible  
Visual  
SupervisedOutput  
NonSupervisedOutput  
CommonAlarmPutput  
CommonTroubleOutput  
CommonSupervisoryOutPut  
CommonMonitorOutput  
LEDOutput  
AnalogOutput  
AudioMessage  
Amplifier  
Card  
SecurityAlarm  
SecurityTrouble  
SecurityTamper  
SecurityMaintenance  
SecurityCommunicationFault  
SecurityDisarmed  
SecurityExitTimer  
SecurityEntryTimer  
SecurityBypassed  
SecurityStay  
SecurityAway  
SecurityStayFail  
SecurityAwayFail  
SecurityClosingTrouble  
SecurityNoClose  
SecurityPartitionUpdate  
Complete  
Spare  
AccessACFail  
AccessLowBattery  
AccessStrikeFault  
144  
145  
146  
147  
Y
Y
Y
Y
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com  
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: [email protected]  
 
FS-8700-39 EST3 Driver Manual  
Type  
Page 19 of 21  
Encode  
Value  
148  
149  
150  
151  
Alarm Trouble Supervisory Monitor Others  
AccessReaderFault  
AccessInternalFault  
AccessCommunicationFault  
CmdList  
Y
Y
Y
Y
Appendix C.2.  
Output data format  
Each output device is associated with a 16-bit value. This value consists of two byte fields, the  
device type (LSB) and the device state (MSB).  
FieldServer Data Array Object (16-bit)  
Attribute (8-bit)  
Command (8-bit)  
These values are provided by the EST panel and are described in the EST3 ECP protocol  
specification as follows. These values will be put in the Command field.  
Command  
Encode Value  
Activate / Away  
Enable  
Restore / Disarm  
Disable  
01h  
02h  
11h  
12h  
The attribute byte must be set for writes to Relay and LED outputs. For Relays, the attribute values  
are:  
Attribute (Relay)  
Encode Value  
Enable  
Activate  
Restore  
Disable  
2h  
101h  
11h  
12h  
For LED’s, the attribute values are:  
Attribute (LED)  
Encode Value  
On  
101h  
201h  
301h  
12h  
2h  
Slow Flash  
Fast Flash  
Disable  
Enable  
Off  
1h  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com  
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: [email protected]  
 
FS-8700-39 EST3 Driver Manual  
Page 20 of 21  
Appendix D. EST3 ECP Connection Statistics:  
The EST3 ECP protocol has two distinct levels:  
A poll-response connection is maintained by the EST panel acting as the master. The bytes  
transferred in this process are displayed on the FieldServer as SCADA bytes transmitted and  
received.  
The FieldServer acts as a client by inserting requests into its response messages; the EST panel  
then inserts the requested data into its subsequent polling messages. The bytes transferred in this  
process are displayed on the FieldServer as PLC bytes transmitted and received.  
The following statistics are available on the Driver Aspects screen when viewing Connection Details  
(select the EST Connection in Connection Overview, and press space repeatedly to page to this  
screen):  
Statistic Name  
DLL Rx Char  
DLL Rx Msg  
DLL Tx Char  
DLL Tx Msg  
DLL Timeouts  
DLL IC Timeouts  
DLL Streaming  
DLL Bad Replies  
DLL Link Control  
Gateway Type  
Data Rx Char  
Data Rx Msg  
Data Tx Char  
Data Tx Msg  
Description  
Data Link Layer Bytes Received  
Data Link Layer Messages Received  
Data Link Layer Bytes Transmitted  
Data Link Layer Messages Transmitted  
Data Link Layer Timeouts  
Data Link Layer Inter-Character Timeouts  
Data Link Layer Streaming Errors  
Data Link Layer Bad Replies  
Data Link Layer Link Control Events  
ECP Gateway Type I/II/III  
Data Bytes Received  
Data Messages Received  
Data Bytes Transmitted  
Data Messages Transmitted  
Conn Rx Char  
Conn Rx Msg  
Conn Tx Char  
Conn Tx Msg  
Delta Rx Char  
Delta Rx Msg  
Total Bytes Received on Connection  
Total Messages Received on Connection  
Total Bytes Transmitted on Connection  
Total Messages Transmitted on Connection  
Delta Message Bytes Received  
Delta Messages Received  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com  
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: [email protected]  
 
FS-8700-39 EST3 Driver Manual  
Page 21 of 21  
Appendix E. Driver Error Messages  
Error Message  
Description and Action Required  
This message will be displayed once if any Map Descriptor in a configuration  
file has an odd length. Old EST3 Panels (before 2002) simply do not  
communicate if length is odd.  
This message can be ignored if it is new EST3 panel. But if it is old or  
unknown, try making Map Descriptor having even length before contacting  
technical support.  
EST3:#01 FYI. For an  
Old EST3 Panel, Read  
MD length must be even.  
EST3:#02 Err. Read MD  
length must > 0 and <=  
%d  
Numbers of addresses to be read per request are limited.  
Edit configuration file to set Map Descriptor length within specified range.6  
EST3:#03 Err. Write MD  
must have length = 1  
EST3: #04 Unknown  
Escape Sequence 1B  
%02X considered as  
%02X  
One Map Descriptor can write only 1 value. Change length to 16.  
This message is printed if the FieldServer receives sequences that are not  
specified. Specified sequences are 1B 82, 1B 8D and 1B 9B. This message  
is for information only and can be ignored unless the data stored by the  
FieldServer is invalid in which case, call Tech support.  
6 Download the configuration file, make the necessary changes, upload to the FieldServer and cycle  
power to the FieldServer for the changes to take effect.  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com  
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: [email protected]  
 

Electro Voice Portable Speaker PIM 152 User Manual
Extron electronic Network Cables IN1124 User Manual
Fisher Price Baby Monitor C7051 User Manual
Fisher Price Baby Swing V3394V3394 User Manual
Freestyle Watch 814 User Manual
Frigidaire Freezer 297068500 User Manual
Fujitsu Network Card BX600 User Manual
Fundex Games Board Games On the Bubble User Manual
GE Air Conditioner 49218 User Manual
GE Washer EWA4600 User Manual