LIMITED WARRANTY & LIMITATION OF LIABILITY
SPECIFICATIONS
Each Fluke product is warranted to be free from defects in material and
workmanship under normal use and service. The warranty period is one
year and begins on the date of shipment. Parts, product repairs and
services are warranted for 90 days. This warranty extends only to the
original buyer or end-user customer of a Fluke authorized reseller, and
does not apply to fuses, disposable batteries or to any product which, in
Fluke's opinion, has been misused, altered, neglected or damaged by
accident or abnormal conditions of operation or handling. Fluke warrants
that software will operate substantially in accordance with its functional
specifications for 90 days and that it has been properly recorded on non-
defective media. Fluke does not warrant that software will be error free
or operate without interruption.
Battery Type: Alkaline 9 volt, NEDA, IEC6LR61installed
Battery Life: 20 hour operation
Environmental Specifications:
Meet requirements of:
PAC 33
•
•
MIL-T-28800E, Type III, Class 3
Printer Adapter Cable
EN50081-1, Electromagnetic Compatibility
Generic Emission Standard: EN55022 and
EN60555-2
Serial to Parallel
Instruction Sheet
•
EN50082-1, Electromagnetic Compatibility
Generic Immunity Standard: IEC801-2, -3, -4, -5
Fluke authorized resellers shall extend this warranty on new and unused
products to end-user customers only but have no authority to extend a
greater or different warranty on behalf of Fluke. Warranty support is
available if product is purchased through a Fluke authorized sales outlet or
Buyer has paid the applicable international price. Fluke reserves the right to
invoice Buyer for importation costs of repair/replacement parts when
product purchased in one country is submitted for repair in another country.
Temperature:
Operating: 0 °C to +50 °C (32 °F to +122 °F)
INTRODUCTION
The PAC 33 is a serial to parallel converter / printer
adapter cable designed for Fluke CombiScopes to
allow direct printing to a parallel printer. The PAC 33
will also work with other equipment, as listed below.
Non-operating: -40 °C to +70 °C (-40 °F to +158 °F)
Parallel Output:
Connector: 25-pole, D-shell, female.
Output: 8-bit parallel
Protocol: Centronix
Signal levels: TTL compatible
Fluke's warranty obligation is limited, at Fluke's option, to refund of the
purchase price, free of charge repair, or replacement of a defective product
which is returned to a Fluke authorized service center within the warranty
period.
The instruments to print from must have print capability
(internal printer drivers).
Typically those types of instruments require a serial
printer. The PAC 33 will now allow parallel printers to
be used
To obtain warranty service, contact your nearest Fluke authorized service
center or send the product, with a description of the difficulty, postage and
insurance prepaid (FOB Destination), to the nearest Fluke authorized
service center. Fluke assumes no risk for damage in transit. Following
warranty repair, the product will be returned to Buyer, transportation prepaid
(FOB Destination). If Fluke determines that the failure was caused by
misuse, alteration, accident or abnormal condition of operation or handling,
Fluke will provide an estimate of repair costs and obtain authorization
before commencing the work. Following repair, the product will be returned
to the Buyer transportation prepaid and the Buyer will be billed for the repair
and return transportation charges (FOB Shipping Point).
Fixed Serial Interface Settings:
9600 Baud, 8 data bits, no parity, 1 stop bit
Handshake: XON / XOFF
The PAC 33 will work with:
•
•
•
•
•
•
•
Fluke CombiScopes
PM6304A and PM6306A RCL meters
Fluke 5720A, 5790A and 5500A Calibrators
Hydra (not NetDaq)
Fluke LANMeters
THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND
IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT,
INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES,
INCLUDING LOSS OF DATA, WHETHER ARISING FROM BREACH OF
WARRANTY OR BASED ON CONTRACT, TORT, RELIANCE OR ANY
OTHER THEORY.
DSP-100 LAN Cablemeter
One-Touch (The printer must have graphics
capability)
Fluke 650 and 652 LAN Cablemeter
Fluke 45 Dual Display Multimeter
•
•
Since some countries or states do not allow limitation of the term of an
implied warranty, or exclusion or limitation of incidental or consequential
damages, the limitations and exclusions of this warranty may not apply to
every buyer. If any provision of this Warranty is held invalid or
unenforceable by a court of competent jurisdiction, such holding will not
affect the validity or enforceability of any other provision.
September 1996,
Fluke Corporation
P.O. Box 9090
Everett
WA 98206-9090
USA
Fluke Industrial B.V.
P.O. Box 680
7600 AR Almelo
The Netherlands
Rev. 2, 01/97
© 1996,1997 Fluke
Corporation.
All rights reserved.
Printed in The
Netherlands.
All product names are
trademarks of their respective companies
|