Model 100-SSE
Special Needs Extended Length Changing Station
Installation Instructions
Thank you for purchasing a quality Foundations® product. Our goal is 100% consumer satisfaction!
If, for any reason you are not satisfied or if you have questions regarding your product or installation,
please contact our customer service team at 1-877-716-2757. Please DO NOT contact your distributor
or reseller as we are better prepared to assist you.
WARNING
•
•
Failure to follow these warnings and the installation instructions could result in serious injury
or death.
Read all instructions before installing the extended length changing station. Keep these
instructions. DO NOT discard.
SI257F
INSTALLATION - RECESSED
NOTE: If installing a surface-mount changing station,
63 1/4"
see “Installation - Surface-Mount” section.
1"
(1607 mm)
(25.4 mm)
TOP
VIEW
3 7/8"
(98.4 mm)
Recommended Blocking:
Wood double stud blocking is necessary. Contact an architect and
building official to make sure the blocking is adequate and complies
with building codes (Fig. b).
63 1/4" (1607 mm)
Rough-in
Double Stud
For A. D. A. compliance, top of lower double stud MUST be 27“
FRONT
VIEW
21 3/4"
(552 mm)
Rough-in
(68.5 cm) from the floor.
19.4"
(492 mm)
1. Slide changer into blocking area and mark mounting hole location
on blocking studs.
HINT: This may require 2 additional people to help hold changer
For A. D. A.
Double Stud
in position while you are marking the locations.
Compliance
27”
(68.5 cm)
2. Shim changer for a snug fit.
A. F. F
Fig. b
3. Align holes in changer with marked holes and secure using the
appropriate fasteners (Fig. c).
Recess
Recess
Mounting
Holes
Mounting
Holes
NOTE: It is installers responsibility to provide correct fastereners
for other substrates.
4. Ensure all seven (7) fasteners are tight.
Recess
Mounting
Holes
Fig. c
INSTALLATION - SURFACE-MOUNT
Recommended Blocking:
Top
If the walls do not have studs on center, then additional blocking is
necessary (Fig. d).
Contact an architect or building contractor to make sure the
14 3/4
blocking is adequate and complies with building codes.
(374.7 mm)
For A. D. A.
Compliance
48 1/2”
(123 cm)
For A. D. A. compliance, measure up 48 1/2” (123 cm) from the
floor and mark the wall. This locates the position for the top left
attachment hole.
48"
(1219 mm)
on center
A. F. F
Fig. d
NOTE:
- Changer MUST be mounted to studs (Fig. e).
- This unit incorporates a finishing collar that seats behind
the changer’s outside flange. Center the collar as the unit
is being tightened against the wall (Fig. f).
Surface-Mount
Holes
Surface-Mount
Holes
Collar
Wall
Unit
Fig. e
Fig. f
2
|