Fujitsu Server R450 User Manual

PRIMERGY R450  
System configurator and order-information guide  
November 2003  
Contents  
Instructions  
Configuration diagram  
Configurator  
0
I
System software  
Basic unit  
II Processor  
III Memory  
IV Graphics  
V
Accessible drives  
VI Hard disk drives  
VII SCSI controller  
VIII Disk array  
IX Communication/Network  
X
System Management Products  
XI Miscellaneous  
XII National accessories packs  
Change report  
PRIMERGY Server  
 
System configurator and order-informtion guide  
PRIMERGY R450 Status 2003-10-24  
Configuration diagram PRIMERGY R450  
TOP VIEW  
FRONT VIEW  
System unit ( I )  
Extension slots  
Peripheral Bay ( V )  
Graphics ( IV )  
SCSI controller ( VII )  
3.5"x0.5"  
floppy disk  
5.25"x0.5"  
IDE-drive  
LCD  
Disk array ( VIII )  
Communication/Network ( IX )  
Hard Disk Drives ( VI )  
2 channels  
Channel 1  
3.5"x1"  
SCSI-ID 0  
Channel 0  
3.5"x1"  
SCSI-ID 1  
3.5"x1"  
SCSI-ID 2  
1
1
2
3
4
5
6
6
8
7
6
5
4
3
2
1
PCI-X long 64 Bit / 100 MHz hot-plug  
PCI-X long 64 Bit / 100 MHz hot-plug  
PCI long 64 Bit / 66 MHz hot-plug  
PCI-X long 64 Bit / 100 MHz hot-plug  
PCI-X long 64 Bit / 100 MHz hot-plug  
3.5"x1"  
SCSI-ID 0  
3.5"x1"  
SCSI-ID 1  
3.5"x1"  
SCSI-ID 2  
Hot-plug power supply 500W ( I )  
3. PS  
2. PS  
1.PS  
Interface: WIDE SCA (80 pins)  
PCI-X long 64 Bit / 100 MHz hot-plug  
PCI long 32 Bit / 33 MHz  
PCI long 32 Bit / 33 MHz  
Memory ( III )  
The highest assembled bank  
is the hot-spare bank,  
if the feature is enabled  
Processor ( II )  
Processors must be plugged  
in order according the picture  
Xeon MP 3  
Xeon MP 2  
Xeon MP 4  
Xeon MP 1  
Fujitsu Siemens Computers  
3 of 12  
Enterprise Products - PRIMERGY Server  
 
System configurator and order-informtion guide  
Start "PRIMERGY R450"  
PRIMERGY R450  
Status 2003-10-24  
SW Configurator  
with OEM-Software  
without OEM-Software  
for PRIMERGY Server  
for PRIMERGY Server  
Later use of OEM operating system  
software is not allowed,  
Microsoft does not allowe  
the use of OEM-software  
under ESX.  
Vmware-Software  
apart from OEM software by  
VMware and F5  
- ESX Server 1.5 (OEM)  
- ESX Server 2.0 (OEM)(planned)  
Distributions-/ retailware is  
- Virtual SMP for ESX 2.0 (OEM)  
allowed.  
For all SW products listed below please refer to the corresponding software configurator accessible via the  
Extranet under "PC Configurations, Configurator for PRIMERGY SW", URL see below  
MS - Software: W **)  
Novell - Software: ***)  
- NetWare 5.1  
PRIMECLUSTER *)  
- Clustering  
- NT 4.0 Server  
- NT 4.0 Server Enterprise Edition  
- NT 4.0 Server Terminal Server Edition  
- NetWare 6  
- NetWare 6.5 (planned)  
- Load Balancing  
- Windows 2000 Server  
- Windows 2000 Advanced Server  
- Windows Server 2003,  
Standard Edition  
- NetWare Cluster Services 1.6 and  
- NetWare Cluster Services 1.7  
(planned) with FibreCAT  
Linux - Software: **)  
- SuSE Linux Enterprise Server: S  
- SuSE Professional Linux  
- Red Hat Enterprise Linux  
- Red Hat Professional Linux  
CX200, CX400, CX600  
Enterprise Edition  
SCO - Software: **)  
CITRIX-Software für NT: W1  
- Multiuser SW MetaFrame  
LoadBalancing  
- UnixWare 7  
additional User Lizenzen  
MultiPath, Duplex Data  
Manager for NT; W2K; Linux  
easy Mirror for Linux  
NT 4, WIN 2000  
*) Pay attention to release information on datasheet under  
FSC System Management  
Software: V  
- RemoteView Software  
- RemoteView Service Board  
- RemoteView Diagnosis  
**) Pay attention to release and order information in PRINCE -> Operating System  
Backup-Software: U  
***) Supply over distribution or procurement from FSC VP BC Software  
- ARCserve für NT  
You'll find single software configurators and release lists (OS-matrix / system management / security) under following addresses:  
for partners:  
Continue with PRIMERGY  
HW configurator  
Fujitsu Siemens Computers  
4 of 12  
Enterprise Products - PRIMERGY Server  
 
System configurator and order-information guide  
Start PRIMERGY R450  
PRIMERGY R450  
Status 2003-10-24  
Section  
Basic unit  
I
Rack basic unit 4U including  
1 x Xeon MP CPU  
2 channel  
The PRIMERGY R450 basic unit comes with:  
- 3 power supply module, hot-plug redundant  
- 2 channel HD PBay with 3 HD bays each  
- 1 floppy disk drive 1,44MB  
S26361-K845-V200  
S26361-K845-V201  
S26361-K845-V202  
1,5GHz 1 MB TLC  
1,9GHz 1 MB TLC  
2 GHz 2 MB TLC  
- 2 hot-replace and redundant fans  
- a CPU Board for up to 4x Xeon CPUs  
- a Memory Board for 16 memory slots  
- I/O section with  
- System Management Processor  
- Dual LVD/U3W-SCSI controller (Adaptec 7899)  
- VGA graphics 8 MB ATI  
- LAN 10/100 Mbit with RJ45 connector (Intel 82559)  
- 5 64bit / 100 MHz PCI-x slots, 1 64bit / 66 MHz slot, all hot-plug  
- 2 32bit / 33 MHz long PCI slots  
- ServerStart packet incl. ServerBooks CD,  
ServerSupport CD and ServerView  
Mounting kit for PRIMERGY R450  
- 1 pair of telescopic rails (730-810mm)  
- 1 pair of carrier rails  
- 1 bracket PC-Rack  
- 1 cable management PC-racks  
Mounting kit for mounting of servers in FSC 19" PRIMECENTER- racks  
and all server racks conforming to EIA standard EIA-310-D for 19" racks.  
Therefore the mounting kit is variable in deepth from 730-810mm  
PRIMERGY PRIMECENTER- Rack  
External Interfaces  
2 x RS-232-C (serial, 9 pin)  
1x Centronics (parallel, 25 pin,  
EPP/ECP compatible)  
1 x keyboard (PS/2)  
1 x mouse (PS/2)  
External Interfaces for ServerManagement  
SNP:SY-F1647E301-P  
Installation ex works for one  
server or subsystem.  
1 x RS-232-C (serial, 9 pin)  
1 x RJ45 LAN  
1 x Power Jack  
Hereby the rack will be delivered  
completely pre-mounted and  
all wired connections are tested.  
With racks 12U, 24U, 38U:  
Systems and components  
will be delivered installed in the rack  
With racks 46U:  
1 x VGA (15 pin)  
1 x USB Frontside  
2 x USB Backside  
1 x RJ45 LAN  
Systems and components  
will be delivered separately  
To be ordered only together with  
a PRIMERGY-  
"Rack-mounting ex factory"  
This service is to be ordered once  
per installable server/storage  
subsystem, in order to get the  
server/storage subsystem  
PRIMECENTER rack  
e.g.:  
S26361-K826-V10x  
mounted into the PRIMERGY racks.  
In case of the 46 U PRIMERGY Rack,  
this service has to be ordered,  
to get the mounting kits and the  
cables installed  
refer configurator PC-Rack  
max. 1x per System  
PRIMERGY 42/23U Rack  
This kit can be ordered,  
if it is planned to mount the rack  
version in an already available  
FSC 42/23U rack  
important notice !  
the mounting kit for PRIMERGY R450  
is included the basic version and  
will be delivered with every R450  
S26361-F1331-L141  
Mounting kit for 42/23U rack  
- 1 pair of carrier rails  
- 1 pair of telescopic rails  
- 1 cable carrier  
max. 1x per system  
A
Fujitsu Siemens Computers  
Enterprise Products - PRIMERGY Server  
5 of 12  
 
System configurator and order-information guide  
PRIMERGY R450 Status 2003-10-24  
A
There are 3 bays for hot-plug power supplies, each with 500W  
Each basic unit contains 3 modules and provides redundancy  
for a fully equipped system  
Section  
Processor  
II  
A mix of processors with different clock frequency and different On-Chip cache cannot be used  
The multi-processor system premises a multi-processor operating system  
Terminators are not necessary  
S26361-F2817-E151  
S26361-F2817-E191  
S26361-F2817-E202  
XEON MP 2GHz  
XEON MP 1,5GHz  
XEON MP 1,9GHz  
with 1 MB TLC on Chip,  
heat sink and "Easy retention"  
with 1 MB TLC on Chip,  
heat sink and "Easy retention"  
with 2MB TLC on Chip,  
heat sink and "Easy retention"  
up to  
3x  
occupies slot for one CPU  
max. 3x per system  
occupies slot for one CPU  
max. 3x per system  
occupies slot for one CPU  
max. 3x per system  
Section  
Memory  
III  
There are 16 memory slots available (4 banks, 4 modules each)  
They can optionally be equipped with 128 MB, 256 MB, 512 MB or 1GB registered DDR-RAM modules (PC1600)  
The maximal extension is 16 GB with today available 1GB modules!  
Any mix of modules within one memory bank is not allowed  
ECC with memory scrubbing and chipkill is standard  
Optional hot-spare memory functionality can be configured in the BIOS (redundant memory bank 3 + 1)  
S26361-F2550-E542  
S26361-F2550-E543  
S26361-F2550-E544  
S26361-F2550-E545  
Main memory 512MB  
Main memory 1024MB  
PC1600 registered DDR RAM  
Main memory 2048MB  
PC1600 registered DDR RAM  
Main memory 4096MB  
PC1600 registered DDR RAM  
PC1600 registered DDR RAM  
4x  
consisting of 4 modules  
occupies one bank  
consisting of 4 modules  
occupies one bank  
consisting of 4 modules  
occupies one bank  
consisting of 4 modules  
occupies one bank  
max. 4x per system  
max. 4x per system  
max. 4x per system  
max. 4x per system  
Section  
Graphics  
IV  
B
Fujitsu Siemens Computers  
Enterprise Products - PRIMERGY Server  
6 of 12  
 
System configurator and order-information guide  
B
PRIMERGY R450  
Status 2003-10-24  
Section  
Accessible drives  
V
SNP:SY-F2313E1-P  
CD-ROM 0,5" 24xATAPI  
1x Connector: LD50  
SNP:SY-F2312E1-P  
DVD drive 0,5"  
A CD-ROM or DVD-ROM drive is required for  
installing the system with "Sever Start"  
supplied with the system unit!  
Note: There is no  
8/24x or faster  
incl. description (Ger/US)  
0.5" * 5.25", anthracite bezel  
max. 1x per system  
anthracite bezel  
occupies one drive bay  
max. 1x per system  
CD-ROM in the  
basic unit!  
Section  
Hard Disk Drives  
VI  
while stocks last  
SNP:SY-F2336E118-P  
SNP:SY-F2336E136-P  
Hard disk 18GB  
Hard disk 36GB  
10000rpm, <7ms, min. 4MB Cache  
U160 SCSI (160 MB/sec)  
Interface: WIDE SCA (80 pins)  
hot pluggable drive  
10000rpm, <7ms, min. 4MB Cache  
U160 SCSI (160 MB/sec)  
Interface: WIDE SCA (80 pins)  
hot pluggable drive  
occupies 1" bay  
occupies 1" bay  
max. 6x per system  
max. 6x per system  
S26361-F2336-E173  
S26361-F2336-E114  
Hard disk 73GB  
Hard disk 146GB  
10000rpm, <7ms, min 8MB Cache  
U160 SCSI (160 MB/sec)  
Interface: WIDE SCA (80 pins)  
hot pluggable drive  
10000rpm,<5,5ms,min. 8MB Cache  
Ultra 160 SCSI (160MB/s)  
Interface: Wide SCA (80-pins)  
hot pluggable drive  
occupies 1" bay  
occupies 1" bay  
max. 6x per system  
max. 6x per system  
S26361-F2336-E518  
Hard disk 18GB  
S26361-F2336-E536  
S26361-F2336-E573  
Hard disk 36GB  
Hard disk 73GB  
15000rpm, <4ms, min. 8MB Cache  
Ultra 160 SCSI (160MB/s)  
Interface: Wide SCA (80-pins)  
hot pluggable drive  
15000rpm, <4ms, min. 8MB Cache  
Ultra 160 SCSI (160MB/s)  
Interface: Wide SCA (80-pins)  
hot pluggable drive  
15000rpm, <4ms, min. 8MB Cache  
Ultra 160 SCSI (160 MB/sec)  
Interface: Wide SCA (80-pins)  
hot pluggable drive  
max. 6  
occupies 1" bay  
occupies 1" bay  
occupies 1" bay  
max. 6x per system  
max. 6x per system  
max. 6x per system  
S26361-F2764-E136  
S26361-F2764-E173  
S26361-F2764-E114  
Hard disk 36GB  
Hard disk 73GB  
Hard disk 146GB  
10000rpm,<5,5ms, 8MB Cache  
Ultra 320 SCSI (320MB/s)  
Interface: Wide SCA (80-pins)  
hot plug/hot replace tray  
occupies 1" bay  
10000rpm,<5,5ms, 8MB Cache  
Ultra 320 SCSI (320MB/s)  
Interface: Wide SCA (80-pins)  
hot plug/hot replace tray  
occupies 1" bay  
10000rpm,<5,5ms, 8MB Cache  
Ultra 320 SCSI (320MB/s)  
Interface: Wide SCA (80-pins)  
hot plug/hot replace tray  
occupies 1" bay  
SCSI/RAID controller necessary  
max. 6x per system  
SCSI/RAID controller necessary  
max. 6x per system  
SCSI/RAID controller necessary  
max. 6x per system  
S26361-F2764-E518  
S26361-F2764-E536  
S26361-F2764-E573  
Hard disk 18GB  
Hard disk 36GB  
Hard disk 73GB  
15.000rpm,<4ms, 8MB Cache  
Ultra 320 SCSI (320MB/s)  
Interface: Wide SCA (80-pins)  
hot plug/hot replace tray  
occupies 1" bay  
15.000rpm,<4ms, 8MB Cache  
Ultra 320 SCSI (320MB/s)  
Interface: Wide SCA (80-pins)  
hot plug/hot replace tray  
occupies 1" bay  
15.000rpm,<4ms, 8MB Cache  
Ultra 320 SCSI (320MB/s)  
Interface: Wide SCA (80-pins)  
hot plug/hot replace tray  
occupies 1" bay  
SCSI/ RAID controller necessary  
max. 6x per system  
SCSI/ RAID controller necessary  
max. 6x per system  
SCSI/ RAID controller necessary  
max. 6x per system  
C
Fujitsu Siemens Computers  
7 of 12  
Enterprise Products - PRIMERGY Server  
 
System configurator and order-information guide  
PRIMERGY R450 Status 2003-10-24  
C
Section  
SCSI-/Fibre-channel controller  
VII  
A. on-board SCSI Controller for internal hard disks  
2-channel U160-SCSI controller on-board; included as standard  
The following cabling is standard, if no Disk Array Controller is used  
1. Channel A of the U160 controller is connected to the 1st backplane for 3 HDs  
2. Channel B of the U160 controller is connected to the 2nd backplane for 3 HDs  
S26361-F2287-E15  
This interface is only configurable if a RAID Controller  
besides the 0-channel RAID Controller is used  
See section Disk Array Controlller  
External on-board SCSI Interface  
Cable and external  
connector interface  
max. 2x per system for external  
B. SCSI - controller for external hard disk extensions and external peripheral devices.  
while stocks last  
SNP:SY-F1722E1-P  
S26361-F2399-E1  
Controller for the connection of a EMC  
SCSI Controller UW, DE  
Adaptec 2944UW (HBA)  
1 channel differential-ended  
max. 40MB/s; without cable  
32/33 PCI, min. 170mm  
int: LD50 + HD68, ext: HD68(S)  
SW:  
SCSI U160 Controller  
Symmetrix (only available as option)  
Supported only in Microsoft Windows  
NT and Windows 2000 operating  
systems  
Adaptec SCSI card 29160  
1 channel: LVD+Fast/Ultra (decoup.)  
LVD con. for HD, withoud cable  
Fast/Ultra con. access. drives  
64/66 (32/33) PCI, min. 180mm  
int: Fast 50-pin or Ultra HD68  
+ LVD HD68; ext: HD68(LVD)  
SW:  
4x  
max. 2x per system  
max. 2x per system  
5x  
C. Fibre Channel controller for subsystems and SAN  
while stocks last  
while stocks last  
SNP:SY-F2244E2-P  
1GBit/s FC Controller  
SNP:SY-F2244E1-P  
1GBit/s FC Controller  
Qlogic  
Qlogic  
QLA 2200  
QLA 2200F, full height braket  
1 Channel 1GBit/sec FC Controller  
MMF(Multimode Fibre) Interface  
incl. SW and description (Ger/US)  
PCI 64Bit / 66MHz, 175mm  
3.3V and 5V tolerant signaling  
max. 4x per system  
1 Channel 1GBit/sec FC Controller  
CU (copper) Interface  
incl. SW and description (Ger/US)  
PCI 64Bit / 66MHz, 175mm  
3.3V and 5V tolerant signaling  
max. 4x per system  
4x  
while stocks last  
S26361-F2843-E1  
2GBit/s FC Controller  
Emulex  
S26361-F2624-E1  
2GBit/s FC Controller  
Emulex  
suitable for  
64Bit/66MHz  
PCI-Slot  
LP9802  
LP9002L  
1 Cannel 2GBit/sec FC Controller  
1 Channel 2GBit/sec FC Controller  
LC Interface for 50um Fibre  
Attention  
LC Interface for 50um Fiber  
PCI 64Bit / 133MHz, 170mm  
3.3V and 5V tolerant signaling  
max. 4x per system  
2GBit/s FC Controller  
require other interface  
connectors for the  
PCI 64Bit / 66MHz, 170mm  
3.3V and 5V tolerant signaling  
max. 4x per system  
optical cables than  
1GBit/s fibre channel.  
freigegeben  
SNP:SY-F1826L1-P  
Supported only in Microsoft  
FC Ctrl for EMC2 Attachment  
Emulex LP8000  
Windows NT and  
Windows 2000 operating  
systems.  
There are other components  
such as switches, GBICs  
or cables which can be  
1 channel 100MB/s  
MMF (Multimode Fibre) Interface  
Connector: Duplex SC  
Controller for the connection  
of a EMC Symmetrix, FibreCAT  
(only available as option)  
ordered for fibre channel SAN  
attachments. (see price list)  
without cable, order seperately  
incl. SW a. description (Ger/US)  
PCI 64Bit/33MHz controller  
max. 4x per system  
All controllers for the connection of external storage systems are delivered without cables  
For the configuration of external cabling see the configurator for external storage systems  
to be continued  
on next page  
D
Fujitsu Siemens Computers  
8 of 12  
Enterprise Products - PRIMERGY Server  
 
System configurator and order-information guide  
PRIMERGY R450 Status 2003-10-24  
D
Section  
Disk Array  
VIII  
D. 0-channel Ultra RAID Controller  
The following cabling is standard, if any Disk Array Controller is used  
1. Channel A of the RAID Controller is connected to the 1st backplane for 3 HDs  
2. Channel B of the RAID Controller is connected to the 2nd backplane for 3 HDs  
S26361-F2728-E48  
Zero-channel RAID Controller  
Adaptec  
zero-channel RAID Controller Adaptec 2000S  
is always to be installed in slot 6  
2000 S  
48MB SDRAM ECC Cache  
in combination with on-board  
U160 SCSI Controller  
without cable  
S26361-F2569-E64  
incl. SW and description (Ger/US)  
64/66 PCI Controller  
3.3V signaling  
2-channel RAID Controller U160  
Mylex / LSI  
AcceleRAID 352 (Leopard)  
64MB SDRAM ECC Cache  
BBU optional  
max. 1x per system  
Connector: internal 2x HD68;  
external: 2x VHDCI  
S26361-F2385-E32  
2-channel RAID Controller U160  
Adaptec  
The cables for the connection of the  
RAID Controller to the disks in the system  
are included within the basic unit.  
without cable  
incl. SW and description (Ger/US)  
64/33 PCI Controller, 330mm  
3.3V and 5V tolerant signaling  
max. 4x per system  
3200 S  
32MB SDRAM ECC Cache  
BBU optional  
The cables of the connection from the  
subsystems (SX30 / S60) to the RAID  
Controllers, see configurator SX30 / S60  
connector: int. 2x HD68;  
ext. 2x VHDCI  
without cable  
S26361-F2569-E10  
incl. SW and description (Ger/US)  
64/33 PCI Controller, 330mm  
3.3V and 5V tolerant signaling  
RAID Ctrl, Battery Backup Unit  
max. 1x per Controller  
4x  
max. 4x per system  
S26361-F2386-E32  
S26361-F2190-E128  
RAID Ctrl, Cache Upgrade 32MB  
32 MB SDRAM ECC Cache  
max. 1x per Controller  
4-channel RAID Controller U160  
Mylex / LSI  
eXtremeRAID 2000 (Big Apple)  
128MB SDRAM ECC Cache  
BBU  
S26361-F2386-E10  
connector: internal: 2x HD 68;  
external: 4x VHDCI  
RAID Ctrl, Battery Backup Unit  
max. 1x per Controller  
incl. SW and description (G/USA)  
64/33 PCI Controller, 330 mm  
3.3V and 5V tolerant signaling  
max. 4x per system  
4x  
as soon as available  
S26361-F2752-E128  
2-channel RAID Controller U320  
Adaptec  
2200S  
128MB SDRAM ECC Cache  
BBU optional  
plug: internal 2x HD68;  
external: 2x VHDCI  
without cable  
incl. SW and description (Ger/US)  
64/66 PCI controller, 180mm  
3.3V and 5V tolerant signaling  
max. 4x per system  
Max. 8 controllers  
in basic unit  
to be continued  
S26361-F2752-E10  
on previous page  
Cache Battery Backup Unit  
max. 1x per controller  
The fitting connection cables can be found in the  
configurator "external storage systems"  
E
Fujitsu Siemens Computers  
9 of 12  
Enterprise Products - PRIMERGY Server  
 
System configurator and order-information guide  
E
PRIMERGY R450  
Status 2003-10-24  
Section  
Communication / Network  
IX  
on-board LAN Controller  
Fast Ethernet Contr. on-board  
Intel Ethernet Express Pro100+  
Server Adapter, Intel  
The Intel LAN controllers 10/100TX, 1000SX, 1000TX  
can be used with the on-board controller in Teaming Mode.  
ext: for RJ 45-connector  
SW: AFT, VLAN, Fast Channel  
A) Adapters with Teaming capability 10-1000TX/SX  
S26361-F2643-E1  
S26361-F2839-E1  
Gigabit Ethernet Contr. 1000TX  
Fast Ether. Contr. 10/100TX  
Intel 100S Server Adapter  
AFT unter NT, W2k, NW also  
with on-board LAN, WOL, load bal.  
32/33 PCI , min 120 mm, hp  
ext: for RJ45-connector  
Intel Pro/1000 MT Adapter  
PCI 32 (33/66MHz), min 122 mm  
ext: for RJ45-plug, Cat 5  
connection with Cat 5 cabling  
SW: VLAN, Fast Etherchannel  
max. 4x per System  
SW: VLAN, Fast Etherchannel  
max. 4x per system  
S26361-F2732-E1  
S26361-F2730-E2  
Gigabit Ethernet Contr. 1000SX  
Intel Pro/1000 XF Server Adapter  
Adapter Teaming Support  
Gigabit Ethernet Contr.1000TX-G2  
Intel Pro/1000 XT Server Adapter  
Adapter Teaming Support  
4x  
PCI-X (all PCI slots), min 163 mm  
ext: for Duplex SC-connector  
PCI-X (all PCI slots), min 163 mm  
ext: for RJ45-Connector, Cat 5  
Connection with Cat 5 cabling  
SW: VLAN, Fast Etherchannel  
max. 4x per system  
SW: VLAN, Fast Etherchannel  
max. 4x per system  
freigegeben.  
B) Dual Port Adapter 100TX  
IPsec with 3DES (156 bit key) has export  
S26361-F2606-E1  
restriction for several countries.  
No restriction to countries of the EU and:  
- Australia,  
Fast Ethernet dual 10/100TX IPsec  
Intel Pro 100S Dual Port Server  
Controller with IPsec 3DES  
AFT under NT, W2k, NW also  
with on-board LAN, WOL, load bal.  
64/66 bit PCI, min 120 mm, hp  
ext: for 2 x RJ45-connector  
SW: VLAN, Fast Etherchannel  
max. 2x per system  
- Canada,  
- Czech Republic,  
- Hungary  
- Japan,  
- New Zealand,  
- Norway,  
- Poland,  
- Switzerland,  
- United States  
C) Token Ring Adapter  
while stocks last  
S26361-F2117-E502  
Token Ring Controller  
Smart Ringnode MK4  
100/16/4 Mbit, Madge  
AFT (NT4, W2K) with 2 Contr.,  
2 redundant rings with 4 contr.  
32/33 PCI, min. 164 mm  
ext: for RJ45 or SUB-D9-plug  
SW:  
2x  
max. 2x per system  
F
Fujitsu Siemens Computers  
10 of 12  
Enterprise Products - PRIMERGY Server  
 
System configurator and order-information guide  
PRIMERGY R450 Status 2003-10-24  
F
Section  
System Management Products (RemoteView)  
X
S26361-F1790-E219  
without graphical  
RemoteView Software V3.10  
console redirection  
remote maintenance software, manual  
S26361-F2116-E8  
RemoteView external Power Supply  
S26361-F2425-L300  
RemoteView Diagnosis  
IDE Chipdisk  
incl. power cord (with cold device- and Euro plug)  
at the on-board IDE-Controller  
occupies 1* IDE slot  
max. 1x pro System  
S26361-F2425-E220  
RemoteView Battery Backup Unit  
for on-board  
System Management Processor  
max. 1x per system  
Section  
Miscellaneous  
XI  
S26361-F1652-L4  
In connection with rack configurations  
the install variant of the modem  
(S26361-F1652-E4) has to be ordered  
(see rack configurator)  
Modem external 56kbps (V.90)  
MultiTech  
MT5643ZBA-Global  
international approval  
incl. 2m Telephon cord RJ11/RJ11  
Adapter Plug RJ11/TAE  
Serial Interface cable DB25m / DB9f  
AC-Adapter w. German Power Cord  
occupies one COM port  
max. 1x per system  
needed for RemoteView  
Section  
National accessories packs  
XII  
Options and other peripherals  
For other options, refer to separate "Product specific options"  
These options are supplied lose with the shipment  
For suitable peripherals for this product, please refer to the section "Peripherals/communication"  
Country specific power cords are not required for rack versions, except for USA&Canada.  
Power cords are shipped in a rack version with inlet connector for non-heating apparatus.  
Description in englisch. Both included in basic unit.  
(1x with Standard PSU, 3x with hot plug upgrade)  
T26139-Y1742-L10  
USA, Canada  
For shipments to USA&Canada, you have to order  
one power cord (1,8m, grey) per power supply.  
End PRIMERGY R450  
Fujitsu Siemens Computers  
11 of 12  
Enterprise Products - PRIMERGY Server  
 
System configurator and order-information guide  
PRIMERGY R450 Status 2003-10-24  
Change report  
Date  
Order number  
Change  
2003-08-13  
2003-08-13  
2003-08-13  
2003-08-13  
2003-08-13  
2003-08-13  
2003-08-13  
2003-08-13  
2003-07-22  
2003-07-22  
2003-06-24  
2003-05-22  
2003-04-25  
2003-03-19  
S26361-F2764-E573  
S26361-F2764-E536  
S26361-F2764-E518  
S26361-F2764-E114  
S26361-F2764-E173  
S26361-F2764-E136  
S26361-F2752-E10  
S26361-F2752-E128  
S26361-F2730-E2  
S26361-F2730-E1  
S26361-F2843-E1  
T26139-Y1742-L10  
S26361-F2336-E573  
S26361-F2839-E1  
S26361-F2606-E1  
Hard disk 73GB 15.000rpm Ultra 320 SCSI - now available  
Hard disk 36GB 15.000rpm Ultra 320 SCSI - now available  
Hard disk 18GB 15.000rpm Ultra 320 SCSI - now available  
Hard disk 146GB 10.000rpm Ultra 320 SCSI - now available  
Hard disk 73GB 10.000rpm Ultra 320 SCSI - now available  
Hard disk 36GB 10.000rpm Ultra 320 SCSI - now available  
Cache Battery Backup Unit - now available  
2-channel RAID controller U320 Adaptec 2200S - now available  
Gigabit Ethernet Controller 1000TX-G2 - now available  
Gigabit Ethernet Controller 1000TX - no longer available  
2GBit/s FC Controller Emulex LP9802 - now available  
Power cord for direct deliverys to USA, Can - now available  
Hard disk 73 GB 15000rpm, U160 SCSI - now available  
Gigabit Ethernet Contr. 1000TX Intel Pro/1000 MT Adapter - now available  
Dual Fast Ethernet 10/100TX Ipsec - max. 2x per system possible  
Section Communication / Network: Number of Ethernet Controllers changed  
Hard disk 146GB 10000rpm - now available  
3 Xeon Processors - 1,6GHz 1MB TLC - Special action - no longer available  
3 Xeon Processors - 1,5GHz 512KB TLC - Special action - no longer available  
Xeon Processor MP 1,6GHz 1MB TLC - no longer available  
Xeon Processor MP 1,5GHz 512KB TLC - no longer available  
Xeon Processor MP 1,4GHz 512KB TLC - no longer available  
Basic Unit 1,6GHz 1MB TLC - no longer available  
2003-02-12  
2003-01-24  
2003-01-22  
2002-12-12  
2002-12-12  
2002-12-12  
2002-12-12  
2002-12-12  
2002-12-12  
2002-12-12  
2002-12-12  
2002-10-23  
2002-10-23  
2002-10-15  
S26361-F2336-E114  
S26361-F2636-E361  
S26361-F2636-E350  
S26361-F2636-E161  
S26361-F2636-E150  
S26361-F2636-E140  
S26361-K845-V102  
S26361-K845-V101  
S26361-K845-V100  
Basic Unit 1,5GHz 512KB TLC - no longer available  
Basic Unit 1,4GHz 512KB TLC - no longer available  
3 Xeon processors - 1,6GHz/1Mb - special action - now available  
3 Xeon processors - 1,5GHz/512Kb - special action - now available  
S26361-F2636-E361  
S26361-F2636-E350  
S26361-F2817-E151  
S26361-F2817-E191  
S26361-F2817-E202  
S26361-K845-V200  
S26361-K845-V201  
S26361-K845-V202  
S26361-F2636-E350  
S26361-F2425-L300  
new processors: 1,5GHz 1 MB iL3  
1,9GHz 1 MB iL3  
- now available  
2
GHz 2 MB iL3  
2002-10-15  
new basic units: 1,5GHz 1 MB iL3  
1,9GHz 1 MB iL3  
- now available  
2
GHz 2 MB iL3  
3x XEON 1,5GHz/512 - no longer available  
RemoteView external Power Supply inclusive power cable G and power cable rack - now available  
power cable UK/US removed  
2002-08-21  
2002-08-20  
S26361-F1652-L4  
SNP:SY-F1652L3-A  
Section VII  
2002-08-19  
2002-08-19  
2002-07-23  
2002-06-24  
2002-06-24  
2002-06-14  
2002-04-18  
2002-04-18  
2002-03-14  
Modem extern 56kbps (V.90); Multitech - now available  
Modem extern 56kbps (V.90); Microlink - no longer available  
B. SCSI - controller for external hard disk extensions ... - now 4x available  
FC Controller 66MHz, MMF Interface - available further on  
FC Controller 66MHz, Cu Interface - available further on  
Rack mounting: universal installation kit - now available  
Special action 3 Xeon processors 1,6GHz - now available  
Special action 3 Xeon processors 1,5GHz - now available  
First release  
SNP:SY-F2244E2-P  
SNP:SY-F2244E1-P  
S26361-F2636-E361  
S26361-F2636-E350  
Fujitsu Siemens Computers  
12 of 12  
Enterprise Products - PRIMERGY Server  
 

Echo Chainsaw X52000020 User Manual
Edelbrock Automobile Parts 1768 User Manual
Estate Range W10173754A User Manual
Fellowes Paper Shredder MS7CS User Manual
Fujitsu Laptop S6240 User Manual
Furuno Marine RADAR FR 2110 User Manual
Gateway Laptop EC58 User Manual
Gateway Personal Computer FX542X User Manual
Gitzo Camcorder Accessories G1327 User Manual
Global Machinery Company Nail Gun ACALN User Manual