ZICP360NX
GE Monogram® 36" Professional Built-In Bottom Freezer Refrigerator
Dimensions and Installation Information (in Inches)
The Installation Space
Door Swing Clearances
The finished cutout width must be 35-1/2".
The installation must allow for clearances to adjacent walls
or cabinets. These refrigerators are equipped with a 2-
position door stop. The factory-set 130° door swing can be
adjusted to 90° if clearance to adjacent cabinets or walls is
restricted.
35-1/2"
Finished Width
Wall View
2-5/16"
6"
25"
Min. to
Wall
23-7/8"
Behind
Frame
90° Door Swing
130° Door Swing
10"
Electrical
Area
75" From
Floor to Bottom
of Electrical
Area
84-1/2" max
83-1/2" min
Finished
24" Cutout Depth
Cold Water
36-3/4"
Opening
90°
5"
5"
130°
Supply
Note: Icemaker
water connectio
is at the front.
5" Min.
to Wall
3 1/2"
3 1/2"
The cutout depth must be 24"
Allow 25" minimum clearances for a full 130° door swing.
Allow 15" for pan removal.
The refrigerator will project forward, slightly beyond adjacent
cabinetry, depending on your installation.
• 5" minimum clearance is required when the door swing is
adjusted to 90°. If the 90° door stop position is used, pan
access is maintained, but pan removal is restricted.
The cutout depth beneath a soffit
When installed beneath a soffit, the soffit cannot exceed the
24" installation depth shown. The top case trim overlaps the
bottom of the soffit.
35" Case Width
Electrical
Product Dimensions
25-3/4" Case Depth
A 115V, 60Hz., 15 or 20 amp power supply is required. An
individual properly grounded branch circuit or circuit breaker
is recommended. Install a properly grounded 3-prong
electrical receptacle recessed into the back wall. Electrical
must be located on rear wall as shown.
*Shipping Height:
The refrigerator
can be adjusted
to fit into a cutout
that is 83-1/2" min.
to 84-1/2" max.
height. The top case
trim at the front
is 1/2" higher and
will overlap upper
cabinetry or soffit.
Use leveling legs
and wheels for a
maximum 1" height
adjustment.
Note: GFI (ground fault interrupter) is not recommended.
84"* from
floor to
top frame
*Sh
re
to
Water Line
83-1/2"*
at Rear
The water line can enter the opening through the floor
or back wall. Route GE SmartConnect™ Kit or 1/4" O.D.
copper tubing between the cold water line and the water
connection location at the front of the refrigerator. The
tubing must be long enough to extend to the front of the
refrigerator. The installation of an easily accessible shut-off
valve in the water line is required.
83
he
tri
an
or
an
1"
36" Frame to
Frame Width
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
ge.com or call GE Answer Center® service,
800.626.2000.
28-11/16" Depth Including Handles
Listed by
Underwriters
Laboratories
Specification Created 6/08
110113
|