ZISP420DXSS
GE Monogram® 42" Built-In Professional Side-by-Side Refrigerator
with Dispenser and Water Filter
The Installation Space
Dimensions and Installation Information (in inches)
36" Models 12"
42" Models 18"
48" Models 20"
41"
* Shipping height.
Case Width
25-3/4" Case Depth
The refrigerator
can be adjusted to
*Finished Width
fit into a cutout that
is 83-1/2" min. to
84-1/2” max. height.
Note that the top
case trim at the
front is 1/2" higher
and will overlap
upper cabinetry or
soffit. Use leveling
legs and wheels
for a maximum 1"
height adjustment.
*
*84" from
Floor to
Top Frame
6"
Electrical
Area
*83-1/2"
at
Rear
84-1/2" max
83-1/2" min
Finished
5"
75" From Floor
to Bottom
of Electrical
Area
Opening
24"
42" Frame to
Frame Width
5"
5"
Water Supply
3-1/2"
28-11/16" Depth Including Handles
Product Clearances
3-1/2"
Water and electrical locations
These refrigerators are equipped with a 2 position door stop.
The factory set 130° door swing can be adjusted to 90° if
clearance to adjacent cabinets or walls is restricted.
The opening must be prepared with the electrical and water
supply located as shown.
90° Door Swing
130° Door Swing
The cutout depth must be 24".
The refrigerator will project forward, slightly beyond
adjacent cabinetry, depending on your installation.
13"
19"
23-7/8"
Behind
Frame
The cutout depth beneath a soffit:
When installed beneath a soffit, the soffit cannot exceed the
24" installation depth shown. The top case trim overlaps the
bottom of the soffit.
26-5/8"
Frameless cabinets:
The case trim overlaps cabinets at the top and sides.
Therefore, frameless cabinets may require filler strips to
prevent interference with cabinet door swing. The opening
must allow for filler strips.
5" Min.
to Wall
Allow minimum clearances for freezer door and fresh food
door for a full 130° door swing and to allow for pan removal.
5" minimum clearance is required when door swing is
adjusted to 90°. If the 90° door stop position is used, pan
access is maintained, but pan removal is restricted.
Additional Specifications
• A 115 volt 60Hz., 15 or 20 amp power supply is required.
An individual properly grounded branch circuit or circuit
breaker is recommended. Install a properly grounded 3-
prong electrical receptacle recessed into the back wall.
Electrical must be located on rear wall as shown.
Installation Information: Before installing, consult
installation instructions packed with product, or online
at Monogram.com, for current dimensional data.
Note: GFI (ground fault interrupter) is not recommended.
• Water line can enter the opening through the floor or back
wall. The water line should be 1/4" O.D. copper tubing or
GE SmartConnect™ kit between the cold water line and
water connection location, long enough to extend to the
front of the refrigerator. Installation of an easily accessible
shut off valve in the water line is recommended.
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
ge.com or call GE Answer Center® service,
800.626.2000.
As an EnErgy StAr®
partner, gE has determined
that this product meets the
Laboratories
Listed by
Underwriters
EnErgy StAr guidelines
for energy efficiency.
Specification Created 3/08
110199
|