GE Monogram Refrigerator ZISS480DMSS User Manual

Monogram.  
ZISS480DMSS - GE Monogram 48" Built-In Stainless Steel Refrigerator with  
Dispenser and Water Filter  
THE INSTALLATION SPACE  
48" Models 20"  
* Shipping height.  
The refrigerator  
47"  
47-1/2  
Case Width  
can be adjusted to  
fit into a cutout that  
is 83-1/2min. to  
84-1/2max. height  
Note that the top  
case trim at the  
front is 1/2higher  
and will overlap  
upper cabinetry or  
soffit. Use leveling  
legs and wheels for  
height adjustment.  
7"  
*84" From  
Floor to  
Top Frame  
Electrical  
Area  
84 1/2" max  
83 1/2" min  
Finished  
*83-1/2"  
at  
Rear  
5"  
74" From Floor  
to Bottom  
of Electrical  
Opening  
24"  
5"  
48"  
Frame to Frame  
5"  
Water Supply  
3 1/2"  
3 1/2"  
Product Clearances  
Water And Electrical Locations  
These refrigerators are equipped with a 2 position door  
stop. The factory set 130° door swing can be adjusted  
to 90° if clearance to adjacent cabinets or walls  
is restricted.  
The opening must be prepared with the electrical and water  
supply located as shown.  
The cutout depth must be 24".  
Designed for industry standard flush installation. The  
refrigerator will project forward, slightly beyond adjacent  
cabinetry, depending on your installation.  
90° Door Swing  
130° Door Swing  
20"  
15"  
23-7/8"  
Behind  
Frame  
The cutout depth beneath a soffit:  
When installed beneath a soffit, the soffit cannot exceed the  
24installation depth shown. The top case trim overlaps the  
bottom of the soffit.  
28-5/8"  
Frameless cabinets:  
The case trim overlaps cabinets at the top and sides.  
Therefore, frameless cabinets may require filler strips to  
prevent interference with cabinet door swing. The opening  
must allow for filler strips.  
Allow minimum clearances for freezer door and  
fresh food door for a full 130° door swing and to  
allow for pan removal.  
Additional Specifications  
A 115 volt 60Hz., 15 or 20 amp power supply is required. An  
individual properly grounded branch circuit or circuit breaker  
is recommended. Install a properly grounded 3-prong electrical  
receptacle recessed into the back wall. Electrical must be  
located on rear wall as shown.  
4" minimum clearance is required when door  
swing is adjusted to 90°. If the 90° door stop  
position is used, pan access is maintained, but  
pan removal is restricted.  
Note: GFI (ground fault interrupter) is not recommended.  
Water line can enter the opening through the floor or back  
wall. The water line should be 1/4" O.D. copper tubing between  
the cold water line and  
water connection location, long enough to extend  
to the front of the refrigerator. Installation of an easily  
accessible shut off valve in the water line is recommended.  
®
For answers to your Monogram, GE Profile or  
GE appliance questions, visit our website at  
GEAppliances.com or call  
®
GE Answer Center service, 800.626.2000.  
Specification Revised 2/02  
Listed by  
Underwriters  
Laboratories  
R
 

Eclipse Fujitsu Ten GPS Receiver AVN 6000 User Manual
Eizo Computer Monitor FlexScan T550 User Manual
Exido Hair Clippers 235 027 User Manual
Extron electronic Universal Remote IR 301 User Manual
Fagor America Cookware Cast Aluminum Cookware User Manual
Fisher Paykel Washer GWL11 User Manual
Fujitsu Server BX960 S1 User Manual
Fusion Car Speaker EN FR4020 User Manual
GE Computer Monitor LTC MAP User Manual
GE Oven JTP20 User Manual