GE Monogram Refrigerator ZISS480DRSS User Manual

ZISS480DRSS – GE Monogram 48" Built-In Stainless Steel Side-by-Side  
Refrigerator with Dispenser and Water Filter  
The Installation Space  
47"  
Case Width  
36" Models 12"  
42" Models 18"  
48" Models 20"  
* Shipping height.  
The refrigerator  
25-3/4"  
can be adjusted to  
fit into a cutout that  
is 83-1/2" min. to  
84-1/2” max. height.  
Note that the top  
case trim at the  
*Finished Width  
*84" From  
Floor to  
Top Frame  
6"  
*83-1/2"  
at  
Rear  
Electrical  
Area  
84-1/2" max  
83-1/2" min  
Finished  
front is 1/2" higher  
and will overlap  
5"  
upper cabinetry or  
soffit. Use leveling  
legs and wheels for  
a maximum 1" height  
adjustment.  
75" From Floor  
to Bottom  
of Electrical  
Area  
Opening  
24"  
48"  
27-3/4"  
including  
handle  
Frame to Frame  
5"  
5"  
Water Supply  
3-1/2"  
Product Clearances  
3-1/2"  
Water And Electrical Locations  
These refrigerators are equipped with a 2 position door stop.  
The factory set 130° door swing can be adjusted to 90° if  
clearance to adjacent cabinets or walls is restricted.  
The opening must be prepared with the electrical and water  
supply located as shown.  
90° Door Swing  
130° Door Swing  
15"  
20"  
The cutout depth must be 24".  
The refrigerator will project forward, slightly beyond adjacent  
cabinetry, depending on your installation.  
23-7/8"  
Behind  
Frame  
The cutout depth beneath a soffit:  
When installed beneath a soffit, the soffit cannot exceed the  
24" installation depth shown. The top case trim overlaps the  
bottom of the soffit.  
28-5/8"  
Frameless cabinets:  
4" Min.  
to Wall  
The case trim overlaps cabinets at the top and sides.  
Therefore, frameless cabinets may require filler strips to  
prevent interference with cabinet door swing. The opening  
must allow for filler strips.  
Allow minimum clearances for freezer door and fresh food  
door for a full 130° door swing and to allow for pan removal.  
4" minimum clearance is required when door swing is adjusted  
to 90°. If the 90° door stop position is used, pan access is  
maintained, but pan removal is restricted.  
Additional Specifications  
• A 115 volt 60Hz., 15 or 20 amp power supply is required.  
An individual properly grounded branch circuit or circuit  
breaker is recommended. Install a properly grounded 3-prong Installation Information: Before installing, consult  
electrical receptacle recessed into the back wall. Electrical  
must be located on rear wall as shown.  
installation instructions packed with product, or online  
at Monogram.com, for current dimensional data.  
As an EnErgy StAr®  
Note: GFI (ground fault interrupter) is not recommended.  
partner, gE has determined  
that this product meets the  
EnErgy StAr guidelines  
for energy efficiency.  
Listed by  
Underwriters  
Laboratories  
• Water line can enter the opening through the floor or back  
wall. The water line should be 1/4" O.D. copper tubing or  
GE SmartConnectkit between the cold water line and  
water connection location, long enough to extend to the  
front of the refrigerator. Installation of an easily accessible  
shut off valve in the water line is recommended.  
For answers to your Monogram, gE Profileor  
gE® appliance questions, visit our website at  
gEAppliances.com or call  
®
gE Answer Center® service, 800.626.2000.  
Specification Revised 3/08  
110189  
 

EdgeStar Air Conditioner AP12005ECO User Manual
Fagor America Electric Pressure Cooker Express User Manual
Fisher Paykel Range RA610 User Manual
Fisher Price Two Way Radio N5962 User Manual
Fisher Security Camera VCC 4324 User Manual
Fisher VCR FVH E439 User Manual
Frymaster Fryer 17BC User Manual
Furuno Radar Detector CI 68 User Manual
Garland Griddle E22 36 User Manual
GE Cordless Telephone 29735 User Manual