Goldstar Dehumidifier DH30E DH40E DH50E DH50EL DH65E DH65EL DH70EL User Manual |
DEHUMIDIFIER
OWNER'S MANUAL
Please read the operating instructions and safety precautions
carefully and thoroughly before operating your dehumidifier.
As an ENERGY STAR® Partner,
LG Electronics Inc. has Determined
that this product meets the ENERGY STAR®
guidelines for energy efficiency.
You can refer to the Energy Star program in detail
at "www.energystar.gov"
(Except DH30E)
MODEL: DH30E
DH40E
DH50E, DH50EL
DH65E, DH65EL
DH70EL
Safety Precautions
Read all instruction before using.
■ To prevent injury to the user or other people and property damage, the following instructions must be followed.
■ Incorrect operation due to ignoring instructions will cause harm or damage; the seriousness is classified by the
following indications.
WARNING
CAUTION
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to properties only.
■ Meanings of symbols used in this manual are as shown below.
Be sure not to do.
Be sure to follow the instruction.
WARNING
WARNING
Complete all grounding and
installation requirements as
described on page 5.
Disconnect power cord from
receptacle before servicing or
cleaning.
Do not use flammable fluids, solvents,
abrasive cleaners, or strong detergents
to clean the dehumidifier.
• Otherwise, it could cause
• It could cause electrical shock
• It could cause fire or product
electrical shock or fire.
or fire.
damage hazard.
N
E
R
S
C
O
A
U
G
R
I
N
L
B
e
G
R E
R
n
z
en
e
Do not plug the dehumidifier
in until the outside of unit is
completely dry.
Do not use the water collected
in the bucket for drinking
purposes.
Do not clean the dehumidifier
while it is plugged in,
especially if it is wet.
• It could cause electrical shock
and personal injury hazard.
• It is not sanitary and could
cause illness or personal injury
hazard.
• It may cause electrical shock.
3
CAUTION
CAUTION
Be sure to block the wheels to
prevent unit from falling when
installed on a table or shelf.
Be sure to replace bucket
properly after emptying to
prevent water from collecting
on the floor.
Make sure the dehumidifier is
the correct size for the area
you want to dehumidify.
• It may damage the dehumidifier
or cause other damage or
injury.
Do not operate switches with
wet hands.
Install the dehumidifier properly on
a floor, table, or shelf that is level
and strong enough to support it
with a full bucket of water.
Do not install dehumidifier in
an area where temperatures
will fall below 65°F (18°C.)
• It may cause electrical shock.
• It should withstand around
90 lbs (40kg) weight.
• Low temperatures could cause
coils to frost and unit may not
start.
Close all doors, windows and
other outside openings to the
room.
When the unit is to be cleaned,
switch it off.
Do not put a pet or house plant
where it will be exposed to
direct air flow.
• The dehumidifier must be
operated in an enclosed area to
be most effective.
• It will cause electrical shock or
fire.
• This may injure the pet or plant.
4
Operating Instructions
Features
This section contains captioned illustrations of your appliance. Use the drawings to become familiar with
all parts and features and what they look like.
1
1. Control panel
2. Case front
4
3. Power cord
4. Top cover
5. Air filter
5
2
6. Water bucket
7. Cabinet
3
6
7
Electrical requirements
OBSERVE ALL LOCAL CODES AND ORDINANCES.
DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE
THE POWER SUPPLY CORD GROUND PRONG.
3-prong
grounding
type wall
receptacle
Electrical ground is required on this appliance.
3-prong
grounding
plug
A 115-volt 60 Hz, AC only, 15A fused and properly
grounded electrical supply is required. A time delay
fuse or time delay circuit breaker is recommended.
Use a dedicated circuit, serving only this appliance.
Do not use an extension cord.
Ground
prong
Power
supply
cord
Recommended grounding method
For your personal safety, this appliance must be grounded. This appliance has a power supply cord
with a 3-prong grounding plug. To minimize possible shock hazard, the cord must be plugged into a
mating grounding type wall receptacle, grounded in accordance with the National Electrical Code
(ANSI/NFPA 70) latest edition and all local codes and ordinances. If a mating wall receptacle is not
available, it is the personal responsibility and obligation of the customer to have a properly grounded
3-prong wall receptacle installed by a qualified electrician.
5
Operating your dehumidifier
Continuous On.
BUCKET
FULL
HUMIDITY
CONTROL
4Hr. On/Off
2Hr. On/Off
High
Low
FAN
SPEED
TIMER
POWER
CONTROL PANEL
The dehumidifier control panel contains: Bucket Full Indicator, Humidity Indicator, Power Control, Humidity Control, Fan
Speed and Timer Control.
Bucket Full indicator ---This light glows when the water bucket is full and needs to be emptied.
Power --- Operation starts when this button is pressed and stops when the button is pressed again.
Humidity Control --- This button controls the humidity in the room.
•
: To raise the humidity setting
•
: To lower the humidity setting
• The humidity setting can be set to a permanent "On" setting or to a specific humidity setting between 35% and 70%
in 5% increments.
"On" setting - dehumidifier runs continuously regardless of humidity condition.
35% - 70% setting - dehumidifier shuts on and off according to surrounding humidity conditions.
Fan Speed --- This controls the speed of the airflow.
• High: Fan speed is set to high.
• Low: Fan speed is set to low.
• When Fan Speed button is pressed, the fan speed mode is changed.
Energy Timer --- Press this button to select type of operation.
• Select Constantly On for uninterrupted operation.
• Select either 2 or 4 Hr. On/Off for cycled operation:
The unit will operate for 2 or 4 hours, and then shut off completely for 2 or 4 hours.
The cycle repeats until you change the setting.
• When Energy Timer button is pressed, the Timer indicator lights shift as follows:
Continuous On ■ 2 Hr. On/Off ■ 4 Hr. On/Off ■ Continuous On.
Auto Restart --- Once power is restored after a power failure, the unit returns to its previous operation setting. The fan
turns on immediately but, humidity control starts after a 2 minute delay.
TO OPERATE THE DEHUMIDIFIER:
1. Plug the power cord into an electrical outlet. Press the power button.
2. Set the humidity Control to "On" or to a specific humidity level between "35% RH(Relative Humidity) and
70%RH(Relative Humidity)" for normal operation.
If you need drier air, press the
If you need less moister air, press the
Humidity Control button.
Humidity Control button.
3. Press the Power button to stop the unit manually.
4. Press the Timer button to set the amount of time you want the unit to run.
At the end of that time, the unit will shut off.
The Timer can be set for : Continuous On, 4 hours or 2 hours.
5. If you want to control the speed of airflow, press Fan Speed button. Each time that the Fan Speed button is pressed,
the fan speed mode is shifted: High ■ Low ■ High
Note: Be careful not to lose the water bucket.
This dehumidifier doesn't run if the water bucket is not installed properly.
6
Automatic shut off
The dehumidifier will turn off automatically when the bucket is
full, or when the bucket is removed or not replaced in the
proper position.
The bucket must be replaced in the proper position for the
dehumidifier to work. The light will be on and the dehumidifier
will not run if the bucket is not in the proper position.
Water level
control switch
Disposing of collected water
1. Empty the bucket manually.
2. Attach a length of garden hose to the threaded bucket drain hose
connection to carry water to the drain.
When being attached to the bucket
drain hose connection, be sure the
hose doesn’t kink or bend. It should
lie flat from the dehumidifier to the
drain.
The bucket has a threaded hose
connection which can be left open.
Drill a 1/4" (6.4 mm) hole in the
center of the hose connection.
Once opened, the hose connection
will continually drain water from the
bucket.
When the bucket is full, pull out and
empty it into a large sink or tub and
then replace it properly.
NOTE: Do not overtighten the
hose when connecting it to the
bucket. Use a rubber washer and
tighten by hand firmly without
stripping the plastic threads.
NOTE: The hose attachment will
accept a standard garden hose
filling. You can attach a screw-on
cap to use the bucket without a
hose.
NOTE: The nozzle cannot be fixed
after puncture. Use an ordinary
garden hose cap to reclose if
necessary.
NOTE:Be careful while taking out
the bucket as it can cause
damage.
NOTE:When inserting the bucket
into the unit. lifting up the bottom
tip of the bucket lightly makes
insertion easily.
NOTE:Please do not shake
strongly when you carry the
bucket. It can cause to breakage
of the handle or bucket cover.
It is advisable to carry the bucket
by supporting it from the bottom.
Drill
7
Installation Instructions
Choosing the proper location for your dehumidifier
• Use the dehumidifier in a
basement to help prevent
moisture damage.
• Use the dehumidifier in
laundry drying, bathing, and
dishwashing areas which have
excessive moisture.
• Use the dehumidifier to
prevent moisture damage
anywhere books are stored.
Installing the dehumidifier properly
1. Allow at least 12 inches of space on all sides of the unit for good
air circulation.
2. Install your dehumidifier on a floor, table, or shelf. When installing
the dehumidifier on a table or shelf, make sure the table or shelf is
strong enough to support the weight of the dehumidifier with a full
bucket. Do not sit or stand on the dehumidifier.
NOTE: The height of a table or shelf might provide a better position
from which to handle the bucket and help prevent icing of the
coils due to colder air near the floor (such as in a basement.)
12"
12"
3. Lift the bucket and place it in the dehumidifier, making sure the
slots on the bottom side of the bucket are positioned correctly.
4. Rollers let you move the dehumidifier easily.
The cleaning of bucket
1. Pull out the bucket cover.
2. Brush off the filth in the
3. Close the cover.
bucket.
NOTE: Please push the leftside
of the cover after the two
NOTE: Clean the bucket by
wiping with brush and cloth
Upsides are upward completely
when closing the cover.
dampened in a mild detergent
solution.
Upside
Upside
Brush etc.
8
Care and Maintenance
Your dehumidifier is designed to serve you year-
round. It needs practically no attention. However,
you should check your dehumidifier and inspect the
coils annually.
Electrical Shock Hazard
• Disconnect power supply cord from receptacle before
performing any maintenance.
You may want an Authorized Service Center to
perform this annual checkup. (Cost of the inspection
is the owner’s responsibility.)
• Be careful when cleaning the coils.
Fins are sharp.
OR
Failure to follow the above precautions could result in
electrical shock or personal injury.
If you are familiar with electrical appliances and their
functions, listed below are instructions which would
allow you to perform the inspection and
maintenance for yourself.
Cleaning the front case bucket and
cabinet
Clean the front case and the cabinet with a soft
cloth, warm water, and a mild detergent.
Do not use bleach or abrasives.
Cleaning the air filter
1-1. First pull out the air filter by pressing the filter
hooks lightly.
Then release two tabs at the bottom side of
the filter.
1-2. Wash air filter with warm water and a mild
detergent. Rinse and dry it.
Replace it in place.
Cleaning the coil
2-1. Remove air filter from the cabinet regarding to
the above.
2-2. Brush the coil gently like arrow in the figure,
if necessary, with warm water and a mild
detergent. Rinse and dry them thoroughly.
Be careful not to spray the coil with a
water hose.
Be careful! Sharp edges!
9
Troubleshooting Tips
Before you call for service, review this list. It may save time and money.
The list includes common occurrences that are not the result of defective workmanship or materials in this
appliance.
Problem
Possible Causes
What To Do
Dehumidifier
does not start
The dehumidifier power
cord is unplugged
• Make sure the dehumidifier plug is pushed
completely into the outlet.
The fuse is blown or circuit
breaker is tripped.
• Check the house fuse or circuit breaker box
and replace the fuse or reset the breaker.
Water bucket is full
• The dehumidifier automatically turns off
when this occurs. Empty the bucket.
Bucket is not installed.
Operation Delay
• Make sure the bucket is in the right place.
• When unit is first plugged in or after a power
outage, there will be a 2 minute delay before
operation begins.
Operation resumes at previous settings.
Dehumidifier
does not dry the
air as it should
Did not allow enough time
to remove the moisture.
• When first installed, allow at least 3 or 4
days to maintain the desired dryness.
Airflow is restricted.
• Make sure there are no curtains, blinds or
furniture blocking the front or back of the
dehumidifier.
The Humidity Control may
not be set low Humidity.
• Press the Humidity Control button to
lower the humidity.
Doors and windows may
not be closed tightly.
• Check that all doors, windows and other
openings are securely closed.
Clothes dryer may be blowing
moisture-laden air into the room.
• Install the dehumidifier away from the dryer.
The dryer should be vented to the outside.
Room temperature is too
low.
• The unit will not operate satisfactorily if the
room temperature is below 65°F. (18 °C.).
Area to be dehumidified is
too large.
• Check with your dealer to see if the capacity
is adequate.
Dehumidifier runs
too much
Doors and windows are open.
• Close all doors and windows to the outside.
Dehumidifier has been
recently turned on or room
temperature is below 65°F.
(18°C.).
• This is normal. Frost will usually disappear
within 60 minutes.
Frost appears on
the coils
Air is moving through the
dehumidifier.
• This is normal.
Fan noise
Bucket drain hose
• Check the hose if one is attached.
connection may be loose.
Water on floor
Water bucket is not all the
way in.
• See Removing and Emptying The Water
Bucket.
10
GOLDSTAR DEHUMIDIFIER LIMITED WARRANTY – USA
LG Ele c tro n ic s In c . w ill re p a ir o r re p la c e yo u r p ro d u c t, a t LG ’s o p tio n , if it p ro ve s to b e d e fe c tive in m a te ria l o r
w o rkm a n sh ip u n d e r n o rm a l u se , d u rin g th e w a rra n ty p e rio d se t fo rth b e lo w , e ffe c tive fro m th e d a te o f o rig in a l
c o nsum e r p urc ha se o f the p ro d uc t. This lim ite d wa rra nty is g o o d o nly to the o rig ina l p urc ha se r o f the p ro d uc t a nd
e ffe c tive o nly whe n use d in the Unite d Sta te s, inc lud ing U.S. Te rrito rie s.
WARRANTY PERIOD:
HOW SERVICE IS HANDLED:
C a ll 1-800-243-0000 a nd c ho o se the a p p ro p ria te p ro m p t. Ple a se
ha ve p ro d uc t typ e (De hum id ifie r) a nd ZIP c o d e re a d y.
La b or: 1 Ye a r fro m the Da te o f Purc ha se .
Pa rts: 1 Ye a r fro m the Da te o f Purc ha se .
De hum id ifie rs re c e ive c a rry-in se rvic e .
Com p re ssor: 5 Ye a rs fro m the Da te o f
Purc ha se .
THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, ANY
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TO THE EXTENT ANY IMPLIED WARRANTY IS
REQUIRED BY LAW, IT IS LIMITED IN DURATION TO THE EXPRESS WARRANTY PERIOD ABOVE. LG WILL NOT BE LIABLE FOR
ANY CONSEQUENTIAL, INDIRECT, OR INCIDENTAL DAMAGES OF ANY KIND, INCLUDING LOST REVENUES OR PROFITS, IN
CONNECTION WITH THE PRODUCT. SOME STATES DO NOT ALLOW LIMITATION ON HOW LONG AN IMPLIED WARRANTY
LASTS OR THE EXCLUSION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATIONS OR EXCLUSIONS
MAY NOT APPLY TO YOU.
THIS LIMITED WARRANTY DOES NOT APPLY TO:
1. Se rvic e trip s to yo ur ho m e to d e live r, p ic k up , a nd / o r insta ll the p ro d uc t, instruc t, o r re p la c e ho use fuse s o r
c o rre c t wiring , o r c o rre c tio n o f una utho rize d re p a irs; a nd
2. Da m a g e s o r o p e ra tin g p ro b le m s th a t re su lt fro m m isu se , a b u se , o p e ra tio n o u tsid e e n viro n m e n ta l
sp e c ific a tio ns o r c o ntra ry to the re q uire m e nts o r p re c a utio ns in the O p e ra ting G uid e , a c c id e nt, ve rm in,
fire , flo o d , im p ro p e r insta lla tio n, a c ts o f G o d , una utho rize d m o d ific a tio n o r a lte ra tio n, inc o rre c t e le c tric a l
c urre nt o r vo lta g e , o r c o m m e rc ia l use , o r use fo r o the r tha n inte nd e d p urp o se .
3. The re fore , the c ost of re p a ir or re p la c e m e nt of suc h a d e fe c tive p rod uc t sha ll b e b orne b y the c onsum e r.
CUSTOMER INTER-ACTIVE CENTER NUMBERS:
Re ta in yo ur Sa le s Re c e ip t to p ro ve d a te o f p urc ha se .
A c o p y o f yo u r Sa le s Re c e ip t m u st b e su b m itte d a t
the tim e wa rra nty se rvic e is p ro vid e d .
To Prove Wa rra nty Cove ra g e
Ca ll 1-800-243-0000 (Mo nd a y ~ Frid a y, 7 AM ~ 8 PM C T;
a n d Sa t u rd a y ,
a p p ro p ria te p ro m p t fro m the m e nu; o r visit o ur we b site a t
8
A M
~
5
P M C T) a n d c h o o se t h e
To Ob ta in Ne a re st Authorize d Se rvic e Ce nte r or Sa le s
De a le r, or to Ob ta in Prod uc t, Custom e r, or Se rvic e
Assista nc e
P/No.: 3828A20315D