Amana Clothes Dryer NGD4500V User Manual

®
29" (73.7 cm) Gas Dryer  
PRODUCT MODEL NUMBERS  
PRODUCT DIMENSIONS  
NGD5100T  
NGD5200T  
NGD5240T  
NGD5400T  
NGD5500T  
NGD5800T  
NGD4500V  
NGD4800V  
Gas supply: Dryer is equipped for use with  
Natural gas. Dryer can be converted to L.P. gas.  
When rigid pipe is used it should be 1/2" IPS.  
When acceptable to the gas supplier and local  
codes, 3/8" approved aluminum or copper tubing  
may be used for lengths under 20 ft (6.1 m). For  
lengths more than 20 ft (6.1 m), larger tubing and  
a different size adapter fitting should be used.  
Pipe-joint compounds resistant to the action of  
A
B
A. Small Opening  
Side-Swing Door  
B. Large Opening  
Side-Swing Door  
L.P. gas must be used. Do not use TEFLON® tape.  
If local codes permit, it is recommended that new  
flexible metal tubing, design-certified by CSA, be  
used for connecting the appliance to the rigid gas  
supply line. (The gas pipe which extends through  
the lower rear of the appliance has 3/8" male pipe  
thread.) An individual manual shutoff valve must  
be installed within 6 ft (1.8 m) of the dryer in  
accordance with the National Fuel Gas Code ANSI  
Z223.1.  
C
D
C. Wide Opening  
Side-Swing Door  
Electrical: A 120-volt, 60-Hz, AC-only, 15- or  
20-amp, fused electrical supply is required. A  
time-delay fuse or circuit breaker is recommended.  
It is recommended that a separate circuit serving  
only this dryer be provided.  
Exhaust venting: Exhaust your dryer to the  
outside. 4" (10.2 cm) vent is required. Rigid or  
flexible metal exhaust vent must be used. Do Not  
use plastic or metal foil vent. Exhaust outlet hood  
must be at least 12" (30.5 cm) from the ground or  
any object that may be in the path of the exhaust.  
D. Wide Opening  
Hamper Door  
RECESSED AREA AND CLOSET INSTALLATION  
3"*  
(7.6 cm)  
For closet installation  
with a door, minimum  
14" max.*  
(35.6cm)  
48 in. 2  
*
(310 cm2 )  
ventilation openings in  
18"*  
(45.7 cm)  
the top and bottom of  
the door are required.  
Louvered doors with  
equivalent ventilation  
openings are acceptable.  
†®TEFLON is a registered trademark of E.I. Du Pont De  
Nemours and Company.  
2
*
24 in.  
3"*  
(7.6 cm)  
(155 cm2 )  
1"  
(2.5 cm)  
27¾"  
(70.5 cm) (12.7 cm)  
5"*  
29"  
(73.66 cm)  
1"  
(2.5 cm)  
1"*  
(2.5 cm)  
EXHAUST VENTING  
B
C
A
4"  
(10.2 cm)  
A. Recessed area  
B. Side view - closet or confined area  
C. Closet door with vents  
*Required spacing  
Box hood style  
4"  
2.5"  
(10.2 cm)  
(6.4 cm)  
4"  
Angled hood style  
(10.2 cm)  
1. Select the route that will provide the straightest and most direct path outdoors. Plan  
the installation to use the fewest number of elbows and turns. When using elbows or  
making turns, allow as much room as possible. Bend vent gradually to avoid kinking.  
Avoid 90° turns.  
NOTE: Side and bottom exhaust installations have a  
90º turn inside the dryer. To determine maximum  
exhaust length, add one 90º turn to the chart.  
Vent Length Chart  
2. Determine vent length.  
Number of  
90° turns  
or elbows  
Type of  
vent  
Box or  
Louvered  
hoods  
Angled  
hoods  
The maximum length of the exhaust system depends upon:  
• The type of vent (rigid metal or flexible metal).  
• The number of elbows used.  
• Type of hood.  
See the exhaust vent length chart that matches your hood type for the maximum vent  
lengths you can use.  
3. Determine the number of elbows you will need.  
IMPORTANT: Do not use vent runs longer than specified in the Vent Length Chart.  
0
1
2
3
4
Rigid metal  
Flexible metal 36 ft (11 m)  
64 ft (20 m)  
58 ft (17.7 m)  
28 ft (8.5 m)  
Rigid metal  
Flexible metal  
54 ft (16.5 m)  
31 ft (9.4 m)  
48 ft (14.6 m)  
23 ft (7 m)  
Rigid metal  
Flexible metal 27 ft (8.2 m)  
44 ft (13.4 m) 38 ft (11.6 m)  
19 ft (5.8 m)  
Rigid metal  
Flexible metal 25 ft (7.6 m)  
35 ft (10.7 m) 29 ft (8.8 m)  
17 ft (5.2 m)  
In the column listing the type of metal vent you are using (rigid metal or flexible metal),  
find the maximum length of metal vent on the same line as the number of elbows.  
Rigid metal  
Flexible metal 23 ft (7 m)  
27 ft (8.2 m)  
21 ft (6.4 m)  
15 ft (4.6 m)  
Because Whirlpool Corporation policy includes a continuous commitment to improve  
our products, we reserve the right to change materials and specifications without notice.  
Dimensions are for planning purposes only. For complete details, see Installation  
Instructions packed with product. Specifications subject to change without notice.  
Ref. W10150630B  
09-11-08  
 

Actron Switch Starter Switch User Manual
Adaptec Switch For Notebooks User Manual
AEG Washer 1003 803 User Manual
Agilent Technologies Welding System 660MHz User Manual
Aiwa Speaker TS W60 User Manual
Alloy Computer Products Switch ES4625 User Manual
American Standard Outdoor Shower 1660100 Series User Manual
Asus Computer Accessories P4SDX User Manual
Banner American Products Laminator PL135 4 User Manual
BB Electronics Surge Protector 232SP9 User Manual