Black Box Network Card MDS932AE 10BT User Manual

STANDALONE  
STANDALONE  
STANDALONE  
STANDALONE  
RACK-CARD  
RACK-CARD  
USER MANUAL  
Version  
1.2  
Revision  
26 January 2004  
MDS933AE-v1.2.doc  
Document name  
 
Version: 1.2  
Page. 3 of 25  
 
1.0  
1.1  
31.12.2001 Initial version of the manual corresponding to version 1.2 of  
the device micro program  
23.10.2003 New function description corresponding to software release  
V1.6  
Corrected Connecter description 9.1  
Changed DSL cable to twisted type 10.2  
1.2  
26.1.2004  
Manual corresponding to software version 1.7  
Implementation of rack card models  
Version: 1.2  
Page. 5 of 25  
 
 
High-speed symmetrical data transmission over one physical copper  
twisted pair with the 135 Ohm impedance according to ETSI TS 101 135.  
ITU-T G.991.2 (G.shdsl) line encoding.  
Line rate in the range from 72 Kbit/s to 2320 Kbit/s in 2 wire mode  
Line rate in the range from 144 Kbit/s to 4624 Kbit/s in 4 wire mode  
Manual or automatic mode of line-speed adjustment.  
Ethernet 10/100Base-T interface, Full/Half duplex.  
Transmition of VLAN packet (IEEE-802.1Q).  
Dynamic table formation of MAC addresses.  
Accumulation of up to 1024 MAC addresses.  
Granting of 95% of the digital channel band to the user.  
In-built functions of diagnostics and self-testing.  
Low power consumption, easy-to-use applications.  
Console port for the local management.  
Telnet port for the local / remote management  
220 Vac power  
For MDS932AE-FXO/FXS  
up to 2 voice cannel.  
Version: 1.2  
Page. 6 of 25  
 
 
Modem AccessDSL Discovery, G.shdsl, 10/100Base-T Bridge,  
VLAN, Adapter 220 Vac  
MDS932AE-10BT  
MDS933AE-10BT  
MDS932AE-FXS  
Modem AccessDSL Discovery, G.shdsl, 1 or 2 pairs, up to  
4.6Mbps, 10/100Base-T Bridge, VLAN, Adapter 220 Vac  
Modem AccessDSL Discovery, G.shdsl, 10/100Base-T Bridge,  
VLAN, Adapter 220 Vac, with FXS interfaces  
Modem AccessDSL Discovery, G.shdsl, 10/100Base-T Bridge,  
VLAN, Adapter 220 Vac, with FXO interfaces  
MDS932AE-FXO  
Version: 1.2  
Page. 7 of 25  
 
 
The front panel of the device has 3 LEDs:  
LOCAL  
informs the user about the status of the local device. The following four statuses are  
possible  
«blinking red»  
informs the user about malfunctioning of the modem’s hardware  
and software. In this case, the modem is out of order and should be  
submitted to the service center for being repaired.  
«red»  
informs the user about an urgent alarm. An abruption of the  
connection, the correspondence of the signal-to-noise ratio which  
does not allow to transmit information and a great number of  
errored blocks can cause an urgent alarm. See the “Command  
menu” chapter for detail.  
«amber»  
«green»  
informs the user about non-urgent alarms. An abruption of  
connection over the user’s interface can cause non-urgent alarms.  
absence of alarms. Normal functioning of the device.  
REMOTE  
informs the user about the status of the remote device. At the time being the remote  
configuring of modems is not provided.  
LINK/ACT The LED is lit upon an incorrect connection to the LAN. The LED is blink upon the  
detection of packets in the segment of the current LAN.  
Version: 1.2  
Page. 8 of 25  
 
 
The back panel of the MDS932AE-10BT and MDS933AE-10BT modem has:  
The grounding bolt of the modem (option);  
The “AC12V” power connector. The connection of the modem to the 220 V power supply  
is implemented using an external power supply unit;  
the “Monitor” connector to control the modem and store statistics;  
“PC” and “HUB” connectors to connect the modem to the LAN using a straight Patch  
Cord (to the PC or HUB, respectively);  
the “DSL” connector to connect the modem to the leased physical line.  
The back panel of the MDS932AE -FXO/FXS modem has additionally:  
The “LINE1” and “”LINE2” connector to connect to PABX (FXO model) or to telephone  
(FXS model).  
Version: 1.2  
Page. 9 of 25  
 
 
Status(L)  
informs the user about the status of the local device. The following four statuses are  
possible  
«blinking red»  
informs the user about malfunctioning of the modem’s hardware and  
software. In this case, the modem is out of order and should be  
submitted to the service center for being repaired.  
«red»  
informs the user about an urgent alarm. An abruption of the  
connection, the correspondence of the signal-to-noise ratio which  
does not allow to transmit information and a great number of errored  
blocks can cause an urgent alarm.  
«amber»  
«green»  
informs the user about non-urgent alarms. An abruption of  
connection over the user’s interface can cause non-urgent alarms.  
absence of alarms. Normal functioning of the device.  
Status(R)  
Ethernet  
informs the user about the status of the remote device. At the time being the remote  
configuring of modems is not provided.  
The LED is lit upon an incorrect connection to the LAN. The LED is blink upon the  
detection of packets in the segment of the current LAN.  
Version: 1.2  
Page. 11 of 25  
 
The delivery set includes:  
the subscriber access device (a modem)  
the power supply source (an AC adapter)  
the cables for the line connections  
The delivery set includes:  
the subscriber access device (a modul)  
the cables for the line connections  
During the connection of the modem stick to the following rules:  
connect the modem using the “straight” Patch Cord cable to the hub  
through the HUB connector or to the PC through the PC connector. Only one device can  
be connected to modem jack at same time.  
connect the modem, if necessary, to the serial port of the PC through  
the “MONITOR” connector using the “straight” modem cable;  
connect the modem to the line using the “DSL” connector;  
connect the power supply unit to the AC power system;  
connect the modem to the power adapter using the “AC 12V” connector; it’s necessary to  
use 13.5V adapter for FXS models  
launch the hyper-terminal operation program on the PC.  
It is necessary to set the following parameters to monitor the modem:  
transmission rate – 9600;  
data bits – 8;  
parity – none;  
number of stop bits – 1;  
flow control – None  
Version: 1.2  
Page. 12 of 25  
 
 
To update the information on the screen use the “Enter” key. The following menu will appear  
on the screen.  
Input Password:  
Please enter your programmed password. The unit will be delivered with the default  
password “admin”  
After entering the password the following menu will appear.  
Discovery G.SHDSL  
Ethernet Monitor V1.7  
+-----------------------+  
+
Main Menu  
+
+-----------------------+  
1. Performance management (PM)  
3. Configuration management (CM)  
4. Security management (SM)  
5. Exit Console  
Select item number or ESC to Upper level menu>>  
The modem is ready to be configured.  
Version: 1.2  
Page. 13 of 25  
 
After the command is typed, press <enter>.  
The <Backspace> key is used to edit commands.  
It is necessary to input item number, for choising menu item,  
You can use “PageUP”, “PageDown” and “Space” keys, for scrolling list of available value of  
parameters,  
The “Esc” key is using for channeling of new value of parameters or returning to up menu  
screen.  
The main menu is the following:  
Discovery G.SHDSL  
Ethernet Monitor V1.7  
+-----------------------+  
+
Main Menu  
+
+-----------------------+  
1. Performance management (PM)  
3. Configuration management (CM)  
4. Security management (SM)  
5. Exit Console  
Select item number or ESC to Upper level menu>>  
The menu consists of five submenus. To choose the needed submenu, it is necessary to  
type its number and press “Enter”. The main menu also contains information about the  
current version of the firmware. It is important that you inform the service center about it  
when being consulted.  
Version: 1.2  
Page. 14 of 25  
 
 
Upon activation of the performance management submenu the following message will be  
displayed.  
Performance Management  
1.Loop Status...  
4.EtherNet Status...  
Select item number or ESC to Upper level menu>>  
Upon activation of the performance management submenu the following message will be  
displayed.  
Performance Management->Loop Status  
System Up Time: 0 Day 00:16:31  
= Loop 1 =  
Loop Up Time: 0 Day 00:15:07  
Operation State:Data  
Line Speed:  
Rx Gain:  
Tx Power:  
S/N Ratio:  
2312K  
5.43 dB  
14.50 dBm  
37.74 dB  
Framer Status: In sync.  
Loop Atten.: -0.19 dB  
Operation Mode: Slave  
Auto/Fixed: Fixed  
Clock Source: Follow Loop  
Annex:  
Fixed Speed:  
A/B  
2312K(36N)  
1.Disconnect  
Select item number or ESC to Upper level menu>>  
Version: 1.2  
Page. 15 of 25  
 
 
Upon activation of the performance management submenu the following message will be  
displayed.  
Performance Management->EtherNet Status  
Link:Link down  
Used Entries:0  
Fwd Packets:0  
Link Speed:----  
Tx Packets:0  
Drop Packets:0  
Link Duplex:----  
Rx Packets:0  
Speed:Auto  
Duplex:Auto  
MAC Address:00-00-00-00-00-00  
1.Clear Counters  
Select item number or ESC to Upper level menu>>  
Upon activation of the configuration management submenu the following message will be  
displayed.  
Configuration Management  
1.DSL Setup...  
4.EtherNet Setup...  
6.Profile...  
Select item number or ESC to Upper level menu>>  
Version: 1.2  
Page. 16 of 25  
 
 
In this menu you can setup the DSL link. When you have selected that menu, the following  
will appear:  
Configuration Management->DSL Setup  
1.[Loop 1 Operation Mode]:Slave  
2.[Loop 1 Auto/Fixed]:Fixed  
5.[Loop 1 Fixed Connection Speed]:2312K(36N)  
6.[Loop 1 Annex]:A/B  
7.[Loop 1 Tx Level Adjustment]:0 dB  
18.[2W/4W]:2W  
Select item number or ESC to Upper level menu>>  
In this menu you can setup the unit to one of the following states:  
Master, Slave  
In this Menu you can setup the unit to one of the following states:  
Auto, Fixed  
If Auto is selected, the unit works in the adaptive mode.  
If Fixed is selected, the unit works with fixed line rates.  
In the Min. Max Connection Speed menu, you can specify your desired Adaptive mode  
speed limit borders in the range of 72 kbps to 2312 kbps for 2wire units and 144 kbps to  
4624 kbps for 4wire models  
Version: 1.2  
Page. 17 of 25  
 
 
In the Fixed Connection Speed menu, you can specify your desired speed in the range of  
72 kbps to 2312 kbps for 2wire units and 144 kbps to 4624 kbps for 4wire models  
With the Appendix menu you can choose between A, B, A / B. If you don’t know what  
Annex you have to setup, and then use the A / B configuration.  
In the Tx Level Adjustments menu you can setup you desired TX output level in the range  
from +2dB to –13dB.  
Please note: changing the default value of 0 to another value may cause serious  
malfunction of the DSL line. It should be changed only by qualified personal.  
In the 2W / 4W (2wire / 4wire) Adjustments menu you can setup you desired number and  
mode of the DSL line. The following modes are possible:  
2W: 1 DSL line, normal mode  
4W: 2 DSL lines, dual pair mode (4W models only)  
2CH: 2 DSL lines, multipoint mode (4W models only)  
Version: 1.2  
Page. 18 of 25  
 
Configuration Management->EtherNet Setup  
1.[Speed]:Auto  
2.[Duplex Mode]:Auto  
3.[Disable Mac Filter]:No  
4.IP Address>>192.168.5.105  
5.Subnet Mask>>255.255.255.0  
6.Gateway Address>>192.168.5.1  
Select item number or ESC to Upper level menu>>  
In the Speed menu, you can setup the Ethernet speed to the following states:  
10M, 100M or Auto  
In the Duplex Mode menu you can setup the Ethernet ports to the following states:  
Half, Full or Auto  
In the IP Address, Subnet Mask and Gateway Address menu you, can setup the desired  
Ip settings  
Users can save and load up to 4 profiles for different tasks. The Profile 0 is the default profile  
during power on. Users have to save all new value of parameters before power off.  
The security management is using for setting the desired password for the console access.  
Version: 1.2  
Page. 19 of 25  
 
 
The main technical specifications of modems of the Black Box family are presented below in  
the table.  
Line interface.  
Standard  
ETSI 101 135  
1
Number of pairs  
Line rate  
2 wire models  
4 wire models  
72 – 2312 Kbit/s  
144 – 4624 Kbit/s  
0.4 mm:  
Communication range for cables with  
the wire diameter of  
0.9 mm:  
aprox:  
approx:  
144 Kbit/s  
8.2 km  
31 km  
2320 Kbit/s  
3.6 km  
13.7 km  
(values are depending on noise  
environment and line quality)  
Line code  
G.shdsl (TC-PAM)  
135 Ohm  
Input impedance of the physical line  
Output signal level  
0.5dBm – 15.5 dBm  
from 0…450 kHz  
User’s interface  
IEEE-802.3  
Transmission spectrum  
Standard:  
IEEE-802.1Q  
Interface type:  
Connector:  
Ethernet 10/100Base-T, Full/Half Duplex  
RJ-45  
Management  
VT100 and TELNET  
Monitoring / Configuration  
Power supply  
Supply voltage:  
~220 Vac ± 10%; 50 Hz  
No more than 5 W  
Power consumption:  
Grounding resistance  
Protection  
No more than 10 Ohm  
Conforms to the requirements of the GOST (State  
Standard) 12.2007.0-85, GOST 7153-85,  
GOST .50033-92 and Norm 9-93  
Climatic conditions  
Temperature range  
-5  
….+45  
Relative humidity of air  
5%…85%  
Version: 1.2  
Page. 20 of 25  
 
 
The equipment of the Black Box family while being packed should withstand all means of  
transport at a temperature in the range form -50 to +50 and the relative humidity of air  
up to 100% at 25 . The equipment can also withstand air-transport at a low air pressure of  
12 kPa (90 Torr) at -50  
.
The packed equipment of the Black Box family can be stored within 12 months (from the date  
of transshipment including transporting time) in storage rooms without heating  
at -50  
at 20 ; short-term increases of air humidity up to 98% (no more than a month a year) at a  
temperature not exceeding 25 without moisture condensation is admissible.  
- +50  
and the mean monthly value of the air humidity of 80%  
The equipment should be stored in storage buildings, which protect the devices from  
atmospheric precipitations. The equipment should be kept on shelves or in factory packages  
in the absence of vapors of acids, alkali and other atmospheric impurities.  
Version: 1.2  
Page. 21 of 25  
 
 
The equipment of the Black Box family should be packed and transported by:  
motor transport with an enclosed truck body;  
enclosed railroad cars;  
unpressurized airplanes and helicopters (up to 10000 m at an air pressure of  
170 Torr);  
river transport (in holds).  
The equipment of the Black Box family should withstand transportation when being packed  
under the following conditions:  
temperature from -50  
to +50  
;
relative air humidity up to 100% at 25  
(within 10 days).  
The equipment of the Black Box family should be packed and withstand transportation by:  
motor transport with the number of transshipments no more than four:  
along the asphalt-concrete and cement-concrete roads at  
of 200 – 1000 km;  
a
distance  
earth roads at a distance of 50 – 250 km at a speed of 40 km/hour;  
different means of transport (airplanes, railway transport in combination with motor  
transport along the asphalt-concrete and cement-concrete roads at a distance of 200 km)  
with the number of transshipments from three to four;  
water transport (excluding sea transport) in combination with motor transport along the  
asphalt-concrete and cement-concrete roads at a distance of 200 km with the number of  
transshipments no more than four.  
During transportation the packages with the equipment should be fixed so that to exclude  
their moving, collision and collision against the transport bodies.  
Version: 1.2  
Page. 22 of 25  
 
 
Type: RJ-45, 8 pin  
Number  
Signal  
Assignment  
1,2  
NC  
-
1
8
RJ-45  
3
LB,a  
LA,a  
LA,b  
LB,b  
NC  
Ttp (4W model only)  
4
tip  
5
ring  
6
ring (4W model only)  
-
7,8  
Type: Sub-D9, female  
Number  
Signal  
NC  
Assignment  
1
2
3
4
5
6
7
8
9
-
1
6
TXD  
RXD  
DTR  
SGND  
NC  
Transmit data  
DB9  
Receive data  
Data terminal ready  
9
Signal ground  
5
-
-
-
-
female  
NC  
NC  
NC  
Version: 1.2  
Page. 23 of 25  
 
 
Type: RJ-45  
Number  
PC assignment  
HUB assignment  
1
2
3
4
5
6
7
8
Tx+  
Tx-  
Rx+  
NC  
NC  
Rx-  
NC  
NC  
Rx+  
Rx-  
Tx+  
NC  
NC  
Tx-  
NC  
NC  
1
8
RJ-45  
Type: RJ-11, 4 pin  
Number  
Signal  
Assignment  
1
NC  
-
1
4
RJ-11  
2
3
4
LA,a  
LA,b  
NC  
tip  
ring  
-
Version: 1.2  
Page. 24 of 25  
 
 
Side  
1
Color of wire  
white/green  
green/white  
white/orange  
blue/white  
Side B  
1
2
3
4
5
6
7
8
2
3
4
5
white/blue  
6
orange/white  
white/brown.  
brown/white  
7
8
Side  
1
Color of wire  
white/green  
green/white  
white/orange  
blue/white  
Side B  
1
2
3
4
5
6
7
8
2
3
4
5
white/blue  
6
orange/white  
white/brown.  
brown/white  
7
8
Version: 1.2  
Page. 25 of 25  
 
 

Billy Goat Lawn Mower AE551, AE551H User Manual
Black Decker Blender BL10451G AR CL User Manual
Black Decker Stud Sensor SF100 User Manual
Briggs Stratton Air Cleaner 543200 User Manual
Broilmaster Gas Grill BP48 1 User Manual
Casio Clock MA1205 EA User Manual
Casio Digital Camera EX Z300 User Manual
Casio Network Router ISA550WBUN3K9 User Manual
C Crane Portable Radio CCRadio plus User Manual
CDA Oven 6Q5 User Manual