I N S T A L L A T I O N I N S T R U C T I O N S
Instrucciones de instalación
Installationsanleitung
Istruzioni di installazione
Installatie-instructies
Instruções de Instalação
Instructions d´installation
PAC520
(Pre-Drywall)
PAC515
(Pre-Drywall)
PAC510
(Post-Drywall)
IN WALL ACCESSORY BOX
Spanish Product Description
German Product Description
Portuguese Product Description
Italian Product Description
Dutch Product Description
French Product Description
PAC 510, 515, 520
Installation Instructions
PAC 510, 515, 520
LEGEND
Tighten Fastener
Pencil Mark
Apretar elemento de fijación
Befestigungsteil festziehen
Apertar fixador
Marcar con lápiz
Stiftmarkierung
Marcar com lápis
Segno a matita
Serrare il fissaggio
Bevestiging vastdraaien
Serrez les fixations
Potloodmerkteken
Marquage au crayon
Loosen Fastener
Drill Hole
Aflojar elemento de fijación
Befestigungsteil lösen
Desapertar fixador
Perforar
Bohrloch
Fazer furo
Praticare un foro
Gat boren
Allentare il fissaggio
Bevestiging losdraaien
Desserrez les fixations
Percez un trou
Phillips Screwdriver
Adjust
Destornillador Phillips
Ajustar
Kreuzschlitzschraubendreher
Chave de fendas Phillips
Cacciavite a stella
Einstellen
Ajustar
Regolare
Afstellen
Ajuster
Kruiskopschroevendraaier
Tournevis à pointe cruciforme
Open-Ended Wrench
Llave de boca
Remove
Quitar
Gabelschlüssel
Chave de bocas
Chiave a punte aperte
Steeksleutel
Entfernen
Remover
Rimuovere
Verwijderen
Retirez
Clé à fourche
By Hand
Optional
Opcional
Optional
Opcional
Opzionale
Optie
A mano
Von Hand
Com a mão
A mano
Met de hand
À la main
En option
Hex-Head Wrench
Security Wrench
Llave de cabeza hexagonal
Sechskantschlüssel
Chave de cabeça sextavada
Chiave esagonale
Llave de seguridad
Sicherheitsschlüssel
Chave de segurança
Chiave di sicurezza
Veiligheidssleutel
Clé de sécurité
Zeskantsleutel
Clé à tête hexagonale
3
PAC 510, 515, 520
Installation Instructions
TOOLS REQUIRED FOR INSTALLATION
3/16"
PARTS
Grounding screw and washer installed at factory
(See figure 4 on page 7)
J (2) (A1, A2, A3)
#10
H (2) (A1, A2, A3)
10-32 x 3/8"
Earthing symbol IEC 60418 No. 5019
affixed adjacent to grounding terminal.
A1 (1)
PAC-510
A3 (1)
PAC-520
A2 (1)
PAC-515
1
2
1
1
2
2
B (4) (A1, A2, A3)
1/4"
C (4) (A1, A2, A3)
1/4" x 2"
F (6) (A1, A2, A3)
D (6) (A1, A2, A3)
M4 x 40mm
E (8) (A1, A2)
1/8-18 x 3/4"
(G) M4 Allen Head Drill Bit (included but not shown)
4
Installation Instructions
PAC 510, 515, 520
mounting surfaces is free of electrical wires and cables
before cutting, drilling, or installing fasteners.
INSTALLATION
The PAC-510 is intended for use in installations where an
existing finshed (drywalled) wall is present, and includes
flanged edges to cover the cutout in wall. The PAC-515 and
PAC-520 are intended for use in installations where the wall
surface has not been finished and the structure (studs) is
exposed. The PAC-515, and PAC-520 require the wall be
finished around the opening of the box after the box has been
installed.
WARNING: EXPLOSION AND FIRE HAZARD!
CUTTING OR DRILLING INTO GAS PLUMBING CAN
CAUSE DEATH OR SERIOUS PERSONAL INJURY!
ALWAYS make certain area behind mounting surfaces
is free of gas, water, waste, or any other plumbing
before cutting, drilling, or installing fasteners.
2. Using a stud sensor, locate and mark studs.
WARNING: IMPROPER INSTALLATION CAN RESULT
DEATH OR SERIOUS PERSONAL INJURY! This accessory
should be installed by qualified personnel.
3. Center and level housing between marked studs.
4. Using housing as a template, draw pencil line completely
around housing.
PAC-510 Site Preparation
NOTE: Housing is designed to fit between and directly against
Locate and Prepare Mounting Site
1. Identify a suitable wall location for the accessory.
two adjacent wall studs.
5. Using a measuring tool, measure the marked area
and compare to the dimensions shown in figure1
below. If measurements match continue to step 6 if
not adjust markings to match dimensions in figure 1
below.
IMPORTANT ! : The PAC-510, 515, AND 520 are
designed for in-wall installation between two wood or
steel studs, 16" on center. Inadequate space will remain
on each side between studs for electrical wires/cables,
plumbing, ductwork, or insulation. Locate accordingly!
6. Cut drywall on outside edge of line and remove.
WARNING: ELECTRICAL SHOCK HAZARD! CUTTING
OR DRILLING INTO ELECTRICAL WIRES OR
CABLES CAN CAUSE DEATH OR SERIOUS
PERSONAL INJURY! ALWAYS make certain area behind
Figure 1
5
PAC 510, 515, 520
Installation Instructions
Accessory Box Installation
1. Insert accessory box into opening, if installing PAC510 or
PAC515, or position PAC520 in desired mounting location.
WARNING: ELECTRICAL SHOCK HAZARD! CUTTING
OR DRILLING INTO ELECTRICAL WIRES OR
CABLES CAN CAUSE DEATH OR SERIOUS
PERSONAL INJURY! ALWAYS make certain area behind
mounting surfaces is free of electrical wires and cables
before cutting, drilling, or installing fasteners.
2. Secure accessory box to studs by:
WOOD STUD:
1. drill four 3/16" dia. pilot holes in studs at mounting
holes.
2. install four M4 x 40mm Allen head connector screws
into pilot holes using an M4 Allen head drill bit
(provided).
STEEL STUD:
1. drill four 3/16" dia. pilot holes in studs at mounting
holes.
2. install four 1/4" countersunk finishing washers and
four 1/4" x 2" Phillips flat head self drilling screws
into pilot holes.
NOTE: When installing PAC520 in configuration B the quantity
of hardware changes to three for both wood and steel
stud installations.
Figure 2
x3
(3/16" dia. Pilot)
(Steel Stud Only)
x4
(3/16" dia. Pilot)
(Steel Stud Only)
(C) x4
(C) x4
(C) x4
(B) x4
(Steel Stud Only)
(C) x4
(C) x4
(Steel Stud Only)
(C) x4
(Steel Stud Only)
(B) x4
(Steel Stud Only)
(Steel Stud Only)
(B) x4
(Steel Stud Only)
PAC510 and PAC515
PAC520
Figure 3
6
Installation Instructions
PAC 510, 515, 520
DANGER: IMPROPER WIRING CAN LEAD TO DEATH
OR SEVERE PERSONAL INJURY! Grounding must be
installed by qualified personnel using a UL Recognized No.
12AWG Green and Yellow grounding wire connected to
grounding lug on mount.
1
2
PAC-510
Installing Accessories
Accessories can be mountied directly to the PAC510, PAC515,
and PAC520 by using the mounting screws provided and the
mounting holes intergrated into the box.
To mount an accessory:
1. Identify area within accessory box that accessory is to be
mounted.
Typical
1
2
2. Align the mounting holes in accessory with mounting holes
in box.
PAC-515
3. Secure accessory to box using Phillips screwdriver and as
many 1/8-18 x 3/4" mounting screws (8 provided) as
required.
NOTE: The top and bottom slots in the side flanges of PAC510
are designed to hall at the center of the studs on 16"
centers. When installing a mount over the top of
PAC510, align mounting holes in mount with top and
bottom slots in side flanges and secure using hardware
specified in the Installation Instructions provided with
the mount.
1
2
PAC-520
Grounding lug location
Figure 4
(E) (8 provided)
Figure 5
7
PAC 510, 515, 520
Installation Instructions
USA/International
Europe
A
P
F
A
P
F
8401 Eagle Creek Parkway, Savage, MN 55378
800.582.6480 / 952.894.6280
877.894.6918 / 952.894.6918
Fellenoord 130 5611 ZB EINDHOVEN, The Netherlands
31 (0)20 5708923
31 (0)20 5708989
Asia Pacific
A
Room 30I, Block D, Lily YinDu International Building
LuoGang, BuJi Town, Shenzhen, CHINA. Post Code: 518112
8807-000054 RevA
¤2007 Chief Manufacturing
04/07
P
F
+86-755-8996 9226 ; 8996 9236 ; 8996 9220
+86-755-8996 9217
|